Bridge Statistics for Harriman, Tennessee (TN)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 39Number of bridges
  • 489ft / 149mTotal length
  • $32,215,000Total costs
  • 305,989Total average daily traffic
  • 55,755Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Harriman
  • No street view available for this location

New bridges in Harriman, TN - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11920-1929
  • 11930-1939
  • 31940-1949
  • 101950-1959
  • 91960-1969
  • 31970-1979
  • 21980-1989
  • 51990-1999
  • 22000-2009
  • 22010-2019
Reconstructed bridges in Harriman, TN - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Harriman, TN
Average Bridge Truck Traffic in Harriman, TN
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 33.3%Very good
  • 16.7%Good
  • 33.3%Satisfactory
  • 11.1%Fair
  • 5.6%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 38.9%Very good
  • 22.2%Good
  • 11.1%Satisfactory
  • 27.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 33.3%Very good
  • 27.8%Good
  • 22.2%Satisfactory
  • 11.1%Fair
  • 5.6%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 9.5%Very good
  • 61.9%Good
  • 23.8%Satisfactory
  • 4.8%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 9.1%Very good
  • 9.1%Good
  • 45.5%Satisfactory
  • 36.4%Fair
Find on map >>   Show street view

Structure Number: 650A0130001,  Location: S OFF SR299-3 M W OF 328 (Lat: 35.971150,  Lng: -84.607500),  Route carried "on" structure: County highway 13,  Year Built: 1970,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 120 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 192 (year 2041),  Design Load: H 15,  Features Intersected: WHITEOAK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 58.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 73012280001,  Location: N OF KINGSTON STEAM PLANT (Lat: 35.917167,  Lng: -84.512400),  Route carried "on" structure: County highway 1228,  Year Built: 2010,  Status: Open,  Structure Length: 2.05m (6.73ft),  Average Daily Traffic: 262 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 419 (year 2041),  Design Load: HL 93,  Features Intersected: TVA HAUL ROAD (PRIVATE)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.805,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 73036890001,  Location: IN OAK RIDGE (Lat: 35.937300,  Lng: -84.552875),  Route carried "on" structure: City street 3689,  Year Built: 2018,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 2,139 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,422 (year 2041),  Design Load: HL 93,  Features Intersected: NORF/SOU RAILWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.724,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.5m (47.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 730A0180001,  Location: ON CO LINE-AT EMORY RIVER (Lat: 35.950233,  Lng: -84.576950),  Route carried "on" structure: County highway 18,  Year Built: 1993,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 690 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,104 (year 2041),  Design Load: HS 20,  Features Intersected: CLIFTY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.409,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 84.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 730A1610001,  Location: W OF SR29-BTWN I40& US 27 (Lat: 35.912100,  Lng: -84.564650),  Route carried "on" structure: City street 481,  Year Built: 1996,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 650 (year 2022),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,040 (year 2041),  Design Load: HS 20,  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.858,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 730A2420001,  Location: IN HARRIMAN - W OF US 27 (Lat: 35.941050,  Lng: -84.542633),  Route carried "on" structure: City street 452,  Year Built: 1987,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 950 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,520 (year 2041),  Features Intersected: NORFOLK-SOUTHERN RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.026,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 730A4610001,  Location: N OF SR61 JUST NE OF I40 (Lat: 35.915033,  Lng: -84.580433),  Route carried "on" structure: City street 461,  Year Built: 1955,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 20 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 32 (year 2042),  Design Load: H 20,  Features Intersected: BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.589,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 730A4610003,  Location: NW OF SR61-N OF I40 (Lat: 35.913783,  Lng: -84.582833),  Route carried "on" structure: City street 461,  Year Built: 1955,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 20 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 32 (year 2042),  Design Load: H 20,  Features Intersected: BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.848,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 730A9980001,  Location: 1.5 M SE OF US70-SR326 JC (Lat: 35.902667,  Lng: -84.604900),  Route carried "on" structure: County highway 998,  Year Built: 2003,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 80 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 128 (year 2041),  Features Intersected: BUCK CREEK,  Facility Carried by Structure: NFA A404
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.209,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 3.7m (12.1ft),  Out-to-Out Width: 4.1m (13.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73I00400003,  Location: JUST W OF US 27 EXIT (Lat: 35.912267,  Lng: -84.595167),  Route carried "on" structure: City street 448,  Year Built: 1969,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 220 (year 2022),  Truck Traffic: 2%,  Average Future Daily Traffic: 352 (year 2040),  Design Load: H 15,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.928,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 35.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 22.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 73I00400005,  Location: IN HARRIMAN (Lat: 35.910033,  Lng: -84.589350),  Route carried "on" structure: Interstate 40,  Year Built: 1969,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 18.29m (60.01ft),  Average Daily Traffic: 30,245 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 51,152 (year 2040),  Design Load: HS 20,  Features Intersected: SR 61 SOU RWY & BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.523,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 29.9m (98.1ft),  Out-to-Out Width: 30.7m (100.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 22.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73I00400041,  Location: AT I40-SR61 HARRIMAN EXCH (Lat: 35.909050,  Lng: -84.588683),  Route carried "on" structure: Ramp Interstate 40,  Year Built: 1958,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 30,245 (year 2020),  Truck Traffic: 32%,  Average Future Daily Traffic: 1,680 (year 2040),  Design Load: HS 20,  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.603,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 73I00400043,  Location: RAMP FROM I40 (Lat: 35.910683,  Lng: -84.584217),  Route carried "on" structure: Ramp Interstate 40,  Year Built: 1960,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 33,219 (year 2020),  Truck Traffic: 29%,  Average Future Daily Traffic: 7,376 (year 2040),  Design Load: HS 20,  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.652,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 31 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 54.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.04m (3.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $166,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $250,000 ( Estimate for 2020)
Find on map >>   Show street view

Structure Number: 73M36940001,  Location: .3 M NE JCT SR29&SR61 (Lat: 35.923350,  Lng: -84.562467),  Route carried "on" structure: City street 3694,  Year Built: 1997,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 314 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 448 (year 2041),  Design Load: HS 20,  Features Intersected: SOUTHERN RAILWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.704,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 73S24010001,  Location: IN HARRIMAN - E OF US 27 (Lat: 35.928633,  Lng: -84.551150),  Route carried "on" structure: City street 1226,  Year Built: 1992,  Status: Open,  Structure Length: 24.08m (79.00ft),  Average Daily Traffic: 6,590 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,544 (year 2041),  Design Load: HS 20,  Features Intersected: EMORY RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Navigation Control: Yes ( Vertical Clearance: 10.3m (33.8ft), Horizontal Clearance: 35.9m (117.8ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Serious,  Channel: Fair,  Operating Rating: 49.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 24.08m (79.00ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: June 2021,  Bridge Improvement Cost: $945,000,  Roadway Improvement Cost: $95,000,  Total Project Cost: $1,418,000 ( Estimate for 2014),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 73S25360001,  Location: 1.8 M SE OF US27-SR61 JCT (Lat: 35.910117,  Lng: -84.534317),  Route carried "on" structure: County highway 2372,  Year Built: 2003,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 493 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 789 (year 2041),  Design Load: HS 20,  Features Intersected: BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.808,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0290003,  Location: .6 M NE JCT SR29&SR61 (Lat: 35.928867,  Lng: -84.556967),  Route carried "on" structure: US 27,  Year Built: 1957,  Status: Posted for load,  Structure Length: 32.80m (107.61ft),  Average Daily Traffic: 15,358 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 24,573 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: EMORY RIVER,  Facility Carried by Structure: FAP 29 846733H
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.038,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 10.6m (34.8ft), Horizontal Clearance: 45.1m (148.0ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 22,  Length of Maximum Span: 45.7m (149.9ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 37.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 32.80m (107.61ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Underwater Inspection Date: June 2017,  Bridge Improvement Cost: $14,514,000,  Roadway Improvement Cost: $1,452,000,  Total Project Cost: $21,772,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 73SR0290005,  Location: IN HARRIMAN (Lat: 35.941250,  Lng: -84.541867),  Route carried "on" structure: US 27,  Year Built: 1967,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 10,556 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 16,890 (year 2041),  Design Load: HS 20,  Features Intersected: SOUTHERN RAILWAY,  Facility Carried by Structure: FAP 29 731087L
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.001,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 45.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.02m (26.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $2,692,000,  Roadway Improvement Cost: $270,000,  Total Project Cost: $4,039,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0290007,  Location: IN HARRIMAN (Lat: 35.942650,  Lng: -84.539867),  Route carried "on" structure: US 27,  Year Built: 1968,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 10,556 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 16,890 (year 2041),  Design Load: HS 20,  Features Intersected: BARNETT BRANCH,  Facility Carried by Structure: FAP 29
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.227,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0290009,  Location: 1.69 EAST OF HARRIMAN (Lat: 35.970617,  Lng: -84.498283),  Route carried "on" structure: US 27,  Year Built: 1963,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 6,345 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 10,152 (year 2041),  Design Load: HS 20,  Features Intersected: SR-29 / SR-61,  Facility Carried by Structure: FAP 29
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.473,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.02m (19.75ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $1,709,000,  Roadway Improvement Cost: $171,000,  Total Project Cost: $2,564,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0292001,  Location: IN HARRIMAN CITY LIMITS (Lat: 35.939200,  Lng: -84.545800),  Route carried "on" structure: Alternate State highway 328,  Year Built: 1985,  Status: Open,  Structure Length: 4.15m (13.62ft),  Average Daily Traffic: 2,549 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,078 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SOUTHERN RAILWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 16.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 13.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.15m (13.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $293,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $440,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 73SR0610001,  Location: 2.86 MI.W.OF HARRIMAN (Lat: 35.892767,  Lng: -84.623333),  Route carried "on" structure: US 27,  Year Built: 1947,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 12,621 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 20,194 (year 2041),  Design Load: HS 20,  Features Intersected: CARDIFF CREEK,  Facility Carried by Structure: FAP 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.925,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 26.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $436,000,  Roadway Improvement Cost: $44,000,  Total Project Cost: $655,000 ( Estimate for 2021)
Find on map >>   Show street view

Structure Number: 73SR0610003,  Location: .30 MI.W.OF HARRIMAN (Lat: 35.897050,  Lng: -84.607683),  Route carried "on" structure: US 27,  Year Built: 1936,  Year Reconstructed: 1965,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 12,815 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 20,504 (year 2041),  Design Load: H 15,  Features Intersected: CANEY CREEK,  Facility Carried by Structure: FAP 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.397,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 49.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.74m (8.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $347,000,  Roadway Improvement Cost: $35,000,  Total Project Cost: $521,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0610004,  Location: .6 M NE JCT SR61&SR382 (Lat: 35.897133,  Lng: -84.607717),  Route carried "on" structure: US 27,  Year Built: 1965,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 12,815 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 20,504 (year 2041),  Design Load: HS 20,  Features Intersected: CANEY CREEK,  Facility Carried by Structure: FAP 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.397,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 49.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.62m (8.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $108,000,  Roadway Improvement Cost: $11,000,  Total Project Cost: $163,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR0610005,  Location: IN HARRIMAN (Lat: 35.909850,  Lng: -84.586083),  Route carried "on" structure: US 27,  Year Built: 1950,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 10,437 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 16,699 (year 2041),  Design Load: HS 20,  Features Intersected: CANEY CREEK,  Facility Carried by Structure: FAP 61 RT LN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.851,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 73SR0610007,  Location: IN HARRIMAN (Lat: 35.911417,  Lng: -84.583817),  Route carried "on" structure: US 27,  Year Built: 1947,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 10,437 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 16,699 (year 2041),  Design Load: HS 20,  Features Intersected: BRANCH,  Facility Carried by Structure: FAP 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.133,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 13 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.79m (2.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $260,000,  Roadway Improvement Cost: $27,000,  Total Project Cost: $391,000 ( Estimate for 2021)
Find on map >>   Show street view

Structure Number: 73SR0610017,  Location: IN HARRIMAN (Lat: 35.907750,  Lng: -84.591783),  Route carried "on" structure: US 27,  Year Built: 1947,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 12,815 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 20,504 (year 2042),  Design Load: HS 20,  Features Intersected: CANEY CREEK,  Facility Carried by Structure: FAP 61
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.320,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.5m (31.2ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.77m (9.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $2,000 ( Estimate for 2022),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73SR3820001,  Location: S OFF US 29-N OF ROCKWOOD (Lat: 35.888617,  Lng: -84.617233),  Route carried "on" structure: State highway 382,  Year Built: 1970,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 3,468 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,549 (year 2041),  Design Load: HS 20,  Features Intersected: CARDIFF CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.336,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 730B2000001,  Location: KINGSTON FOSSIL PLANT (Lat: 35.923333,  Lng: -84.518333),  Route carried "on" structure: ServiceFederal lands road ,  Year Built: 1975,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 200 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2041),  Design Load: HS 20,  Features Intersected: ASH SLUICE PIPES,  Facility Carried by Structure: ACCESS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Tennessee Valley Authority,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 46.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 73023700001,  Location: S AT EMORY R - W OF US 27 (Lat: 35.939733,  Lng: -84.564250),  Route carried "under" structure: County highway 627,  Year Built: 1920,  Structure Length: 0. m,  Average Daily Traffic: 628 (year 2020),  Truck Traffic: 6%,  Features Intersected: SOUTHERN RAILWAY,  Facility Carried by Structure: SOU RWY 841862F
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 16.795,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 6.1m (20.0ft)

Find on map >>   Show street view

Structure Number: 73036890003,  Location: IN OAK RIDGE (Lat: 35.934183,  Lng: -84.554567),  Route carried "under" structure: City street 3689,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 2,464 (year 2020),  Truck Traffic: 4%,  Features Intersected: S.RAILWAY/CARTER AVE N W,  Facility Carried by Structure: SOU RWY 846740T
Minimum Vertical Clearance: 4.25m (13.94ft),  Kilometerpoint: 0.129,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 9.8m (32.2ft)

Find on map >>   Show street view

Structure Number: 730A2990001,  Location: W OFF SR 29 IN HARRIMAN (Lat: 35.936817,  Lng: -84.552000),  Route carried "under" structure: City street 299,  Year Built: 1996,  Structure Length: 0. m,  Average Daily Traffic: 460 (year 2022),  Truck Traffic: 2%,  Features Intersected: NORFOLK S RWY/QUEEN AVE,  Facility Carried by Structure: SOU RWY 846739Y
Minimum Vertical Clearance: 3.40m (11.15ft),  Kilometerpoint: 0.154,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 4.3m (14.1ft)

Find on map >>   Show street view

Structure Number: 73I00400003,  Location: NEAR HARRIMAN TENN. (Lat: 35.911667,  Lng: -84.595000),  Route carried "under" structure: Interstate 40,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 30,245 (year 2020),  Truck Traffic: 32%,  Features Intersected: NFA A448 WARRIOR DR./I40,  Facility Carried by Structure: NFA A448
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 10.847,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 73I00400005,  Location: .5 MI S-W FROM EMORY GAP (Lat: 35.909317,  Lng: -84.587150),  Route carried "under" structure: US 27,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 12,815 (year 2020),  Truck Traffic: 8%,  Features Intersected: I40 RT LN / SR 61,  Facility Carried by Structure: I40 RT LN
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 8.771,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 73I00400015,  Location: NEAR KINGSTON TENN. (Lat: 35.880950,  Lng: -84.508517),  Route carried "under" structure: State highway 58,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 13,614 (year 2020),  Truck Traffic: 4%,  Features Intersected: I40/SR 58,  Facility Carried by Structure: I40 RT LN
Minimum Vertical Clearance: 5.86m (19.23ft),  Kilometerpoint: 22.209,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 73SR0290001,  Location: ROCKWOOD & HARRIMAN (Lat: 35.902417,  Lng: -84.560000),  Route carried "under" structure: City street 5409,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 2,875 (year 2020),  Truck Traffic: 4%,  Features Intersected: SOUTHERN RAILWAY,  Facility Carried by Structure: TVA RR 909221T
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 3.026,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 73SR0290003,  Location: IN HARRIMAN (Lat: 35.929100,  Lng: -84.556967),  Route carried "under" structure: City street 627,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 628 (year 2020),  Truck Traffic: 6%,  Features Intersected: SR-29 / RIGGS CHAPEL RD.,  Facility Carried by Structure: FAP 29
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 18.353,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 45.7m (149.9ft)

Find on map >>   Show street view

Structure Number: 73SR0290009,  Location: NEAR HARRIMAN TENN. (Lat: 35.970650,  Lng: -84.498300),  Route carried "under" structure: State highway 61,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 4,594 (year 2020),  Truck Traffic: 11%,  Features Intersected: SR-29 / SR-61,  Facility Carried by Structure: FAP 29
Minimum Vertical Clearance: 4.09m (13.42ft),  Kilometerpoint: 11.467,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>   Show street view

Structure Number: 73SR0610009,  Location: NEAR HARRIMAN TENN. (Lat: 35.911900,  Lng: -84.583517),  Route carried "under" structure: US 27,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 10,437 (year 2020),  Truck Traffic: 9%,  Features Intersected: SOUTHERN RAILROAD,  Facility Carried by Structure: SOUTHERN RAILROAD
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 9.214,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)