Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Yuba City, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 34Number of bridges
  • 928ft / 283mTotal length
  • $802,000Total costs
  • 479,383Total average daily traffic
  • 22,090Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Yuba City
  • No street view available for this location

New bridges in Yuba City, CA - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 21930-1939
  • 81940-1949
  • 31950-1959
  • 21960-1969
  • 121970-1979
  • 11990-1999
  • 32010-2019
  • 12020-2022
Reconstructed bridges in Yuba City, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Yuba City, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.1%Good
  • 21.1%Satisfactory
  • 31.6%Fair
  • 5.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 75.0%Good
  • 5.0%Satisfactory
  • 20.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 80.0%Good
  • 5.0%Satisfactory
  • 10.0%Fair
  • 5.0%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.3%Very good
  • 31.3%Good
  • 50.0%Satisfactory
  • 12.5%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Good
  • 40.0%Satisfactory
  • 40.0%Poor
Find on map >>   Show street view

Structure Number: 18 0001L,  Location: 03-SUT-070-8.09 (Lat: 38.969306,  Lng: -121.543275),  Route carried "on" structure: State highway 70,  Year Built: 1961,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 46.48m (152.49ft),  Average Daily Traffic: 15,800 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 32,371 (year 2040),  Design Load: HS 20,  Features Intersected: BEAR RIVER (RIO OSO)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.090,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 24,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18 0002,  Location: 03-SUT-020-12.17 (Lat: 39.141411,  Lng: -121.698428),  Route carried "on" structure: State highway 20,  Year Built: 1920,  Year Reconstructed: 1964,  Status: Open,  Structure Length: 0.86m (2.82ft),  Average Daily Traffic: 12,000 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 17,912 (year 2043),  Features Intersected: SUTTER CO EXTENSIONCANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.170,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 26.5m (86.9ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 18 0004,  Location: 03-SUT-020-16.98-YC (Lat: 39.143147,  Lng: -121.609675),  Route carried "on" structure: State highway 20,  Year Built: 1946,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 41,750 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 78,368 (year 2041),  Features Intersected: ABANDONED UP RR SPUR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.980,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2019
Find on map >>   Show street view

Structure Number: 18 0009,  Location: 03-SUT-020-17.00-YC (Lat: 39.143208,  Lng: -121.609314),  Route carried "on" structure: State highway 20,  Year Built: 1947,  Status: Open,  Structure Length: 81.50m (267.39ft),  Average Daily Traffic: 48,000 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 78,367 (year 2041),  Design Load: HS 20,  Features Intersected: FEATHER RIVER,K ST,UP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.000,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 24,  Length of Maximum Span: 49.0m (160.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Serious,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: August 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18 0024,  Location: 03-SUT-020-16.84-YC (Lat: 39.142500,  Lng: -121.612136),  Route carried "on" structure: State highway 20,  Year Built: 1946,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 2.64m (8.66ft),  Average Daily Traffic: 41,750 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 81,720 (year 2043),  Design Load: H 20,  Features Intersected: SUTTER STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.840,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18 003,  Location: 03-SUT-099-R32.64 (Lat: 39.170928,  Lng: -121.635500),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 883 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,045 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: PEASE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18 0031,  Location: 03-SUT-099-R33.95 (Lat: 39.189925,  Lng: -121.635239),  Route carried "on" structure: County highway ,  Year Built: 1970,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 755 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,088 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: EAGER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.1m (102.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18 0033L,  Location: 03-SUT-099-R30.88-YC (Lat: 39.145550,  Lng: -121.635397),  Route carried "on" structure: State highway 99,  Year Built: 1970,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 14,750 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 17,450 (year 2039),  Design Load: HS 20,  Features Intersected: BUTTE HOUSE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.880,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18 0033R,  Location: 03-SUT-099-R30.88-YC (Lat: 39.145464,  Lng: -121.635100),  Route carried "on" structure: State highway 99,  Year Built: 1970,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 14,750 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 17,450 (year 2039),  Design Load: HS 20,  Features Intersected: BUTTE HOUSE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.880,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18 0034,  Location: 03-SUT-099-R31.31-YC (Lat: 39.151569,  Lng: -121.635733),  Route carried "on" structure: City street ,  Year Built: 1970,  Status: Open,  Structure Length: 5.58m (18.31ft),  Average Daily Traffic: 8,506 (year 2008),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,399 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: QUEENS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.7m (90.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C001,  Location: 3 MI S/O OSWALD RD (Lat: 39.024511,  Lng: -121.782589),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 45.99m (150.89ft),  Average Daily Traffic: 737 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 875 (year 2042),  Design Load: HS 20,  Features Intersected: TISDALE RD, TISDALE BYPS,  Facility Carried by Structure: RECLAMATION RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 33,  Number Of Approach Spans: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0024,  Location: 0.02 MI E RECL RD-ROBBINS (Lat: 38.869669,  Lng: -121.706678),  Route carried "on" structure: County highway ,  Year Built: 1975,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 405 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 814 (year 2040),  Design Load: HS 20,  Features Intersected: ROBBINS (DRAINAGE) CANAL,  Facility Carried by Structure: DEL MONTE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0052,  Location: 1.9 MI NE/O SR 70 (Lat: 38.967603,  Lng: -121.515450),  Route carried "on" structure: County highway ,  Year Built: 1934,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 963 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,309 (year 2041),  Features Intersected: YANKEE SLOUGH,  Facility Carried by Structure: SWANSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.8m (19.0ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C0055,  Location: AT 2ND ST JWO FEATHER RIV (Lat: 39.138339,  Lng: -121.608131),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 33,000 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 29,538 (year 2040),  Features Intersected: 2ND STREET (SUTTER ST),  Facility Carried by Structure: BRIDGE ST (5TH ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C0077,  Location: 3.1 MI E/O ACACIA AVE (Lat: 39.163083,  Lng: -121.698506),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 3,551 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,591 (year 2043),  Features Intersected: SUTTER CO EXTENSION CNL,  Facility Carried by Structure: BUTTE HOUSE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C0095,  Location: AT PEASE ROAD (Lat: 39.170764,  Lng: -121.688594),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 1,056 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,457 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: EAST INTERCEPTOR CANAL,  Facility Carried by Structure: TOWNSHIP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0106,  Location: 0.01 MI W OF LARKIN RD (Lat: 39.203889,  Lng: -121.660072),  Route carried "on" structure: County highway ,  Year Built: 1945,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 391 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 301 (year 2042),  Features Intersected: LIVE OAK CANAL,  Facility Carried by Structure: SANDERS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0107,  Location: 1.2 MI W OF BROADWAY (Lat: 39.202783,  Lng: -121.701106),  Route carried "on" structure: County highway ,  Year Built: 1940,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 177 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 446 (year 2043),  Features Intersected: SUTTER CO EXTENSION CNL,  Facility Carried by Structure: SANDERS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 3.2m (10.5ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.1m (23.3ft)

Condition: Channel: Satisfactory,  Culverts: Poor,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.88m (2.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $144,000,  Roadway Improvement Cost: $28,000,  Total Project Cost: $243,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C0109,  Location: 0.7 MI E OF E BUTTE RD (Lat: 39.185219,  Lng: -121.703611),  Route carried "on" structure: County highway ,  Year Built: 1925,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 325 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 217 (year 2041),  Features Intersected: SNAKE RIVER,  Facility Carried by Structure: NUESTRO RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.2m (33.5ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Serious,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $195,000,  Roadway Improvement Cost: $39,000,  Total Project Cost: $328,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C011,  Location: 0.8 MI E OF E BUTTE RD (Lat: 39.185144,  Lng: -121.701094),  Route carried "on" structure: County highway ,  Year Built: 1940,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 325 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 246 (year 2041),  Features Intersected: SUTTER CO EXTENSION CNL,  Facility Carried by Structure: NUESTRO ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 3.2m (10.5ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Channel: Satisfactory,  Culverts: Poor,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.88m (2.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Bridge Improvement Cost: $138,000,  Roadway Improvement Cost: $27,000,  Total Project Cost: $231,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 18C0114,  Location: 0.5 MI W TOWNSHIP RD (Lat: 39.098022,  Lng: -121.698606),  Route carried "on" structure: County highway ,  Year Built: 1950,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 509 (year 2015),  Truck Traffic: 8%,  Average Future Daily Traffic: 272 (year 2041),  Features Intersected: SUTTER CO EXTENSION CNL,  Facility Carried by Structure: BOGUE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.8m (22.3ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 18C014,  Location: 0.5 MI E OF SHELDON AVE (Lat: 39.276006,  Lng: -121.635039),  Route carried "on" structure: County highway ,  Year Built: 2017,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 137 (year 2041),  Design Load: HL 93,  Features Intersected: SUTTER-BUTTE CANAL,  Facility Carried by Structure: PENNINGTON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 18C0142,  Location: BTWN MRYSVL & YUBA CITY (Lat: 39.138478,  Lng: -121.607419),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 57.00m (187.01ft),  Average Daily Traffic: 67,000 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 86,000 (year 2038),  Design Load: HL 93,  Features Intersected: FEATHER RIVER,  Facility Carried by Structure: 5TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 61.0m (200.1ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0143,  Location: NORTH OF BRIDGE STREET (Lat: 39.138361,  Lng: -121.608061),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 67,000 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 86,000 (year 2038),  Design Load: HL 93,  Features Intersected: 2ND STREET,SUTTER STREET,  Facility Carried by Structure: 5TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.4m (70.2ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.8m (143.7ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 21.4m (70.2ft),  Out-to-Out Width: 29.4m (96.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 18C0149,  Location: 0.5 MI W. OF TOWNSHIP RD (Lat: 39.156103,  Lng: -121.698264),  Route carried "on" structure: County highway ,  Year Built: 2021,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 130 (year 2041),  Design Load: HL 93,  Features Intersected: SUTTER CO EXTENSION CNL,  Facility Carried by Structure: FORTNA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 18 0009,  Location: 03-SUT-020-17.00-YC (Lat: 39.143208,  Lng: -121.609314),  Route carried "under" structure: City street ,  Year Built: 1947,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2012),  Truck Traffic: 2%,  Features Intersected: FEATHER RIVER,K ST,UP RR,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 49.0m (160.8ft)

Find on map >>   Show street view

Structure Number: 18 0024,  Location: 03-SUT-020-16.84-YC (Lat: 39.142500,  Lng: -121.612136),  Route carried "under" structure: City street ,  Year Built: 1946,  Structure Length: 0. m,  Average Daily Traffic: 1,500 (year 2013),  Truck Traffic: 2%,  Features Intersected: SUTTER STREET,  Facility Carried by Structure: STATE ROUTE 20
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 11.0m (36.1ft)

Find on map >>   Show street view

Structure Number: 18 003,  Location: 03-SUT-099-R32.64 (Lat: 39.170928,  Lng: -121.635500),  Route carried "under" structure: State highway 99,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 19,400 (year 2009),  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: PEASE ROAD
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 32.640,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 18 0031,  Location: 03-SUT-099-R33.95 (Lat: 39.189925,  Lng: -121.635239),  Route carried "under" structure: State highway 99,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2009),  Truck Traffic: 9%,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: EAGER ROAD
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 33.950,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 18 0033L,  Location: 03-SUT-099-R30.88-YC (Lat: 39.145550,  Lng: -121.635397),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2006),  Truck Traffic: 15%,  Features Intersected: BUTTE HOUSE ROAD,  Facility Carried by Structure: STATE ROUTE 99 SB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 18 0033R,  Location: 03-SUT-099-R30.88-YC (Lat: 39.145464,  Lng: -121.635100),  Route carried "under" structure: City street ,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2006),  Truck Traffic: 15%,  Features Intersected: BUTTE HOUSE ROAD,  Facility Carried by Structure: STATE ROUTE 99 NB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 18 0034,  Location: 03-SUT-099-R31.31-YC (Lat: 39.151569,  Lng: -121.635733),  Route carried "under" structure: State highway 99,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 29,500 (year 2009),  Truck Traffic: 9%,  Features Intersected: STATE ROUTE 99,  Facility Carried by Structure: QUEENS AVE
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 31.310,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>   Show street view

Structure Number: 18C0018,  Location: JUST N/O BRIDGE ST (Lat: 39.138258,  Lng: -121.607839),  Route carried "under" structure: City street ,  Year Built: 1935,  Structure Length: 0. m,  Average Daily Traffic: 17,100 (year 2010),  Truck Traffic: 2%,  Features Intersected: 2ND STREET (SUTTER ST),  Facility Carried by Structure: ABANDONED RR ROW
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 0.000,  Lanes under structure: 3,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 11.6m (38.1ft)

Find on map >>   Show street view

Structure Number: 18C0023,  Location: BRIDGE ST AT HEIKEN WAY (Lat: 39.137450,  Lng: -121.610047),  Route carried "under" structure: City street ,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2010),  Truck Traffic: 4%,  Features Intersected: BRIDGE ST-5TH ST RAMP,  Facility Carried by Structure: ABANDONED RR ROW
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 12.2m (40.0ft)

Discuss Yuba City, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.