National Bridge Inventory (NBI) Statistics
Number of bridges: 48
Total length: 272 meters (892ft)
Total costs: $6,662,000
Total average daily traffic: 2,006,750
Total average daily truck traffic: 118,560
National Bridge Inventory (NBI) Registered Bridges for Arden Hills

New bridges - Historical Statistics

  • 1900-1909: 1
  • 1910-1919: 0
  • 1920-1929: 2
  • 1930-1939: 0
  • 1940-1949: 0
  • 1950-1959: 6
  • 1960-1969: 37
  • 1970-1979: 0
  • 1980-1989: 0
  • 1990-1999: 0
  • 2000-2009: 2

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 4627,  Location: 0.1 MI N OF JCT TH 51 (Lat: 45.038333,  Lng: -93.161667),  Route carried "on" structure: City street 111,  Year Built: 1926,  Status: Posted for load,  Structure Length: 0.70m (2.30ft),  Design Load: HS 20,  Features Intersected: DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 27.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 14.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Bridge Improvement Cost: $74,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $87,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 6201,  Location: 0.9 Mi So of Jct TH 694 (Lat: 45.050200,  Lng: -93.156631),  Route carried "on" structure: County highway 15,  Year Built: 1961,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 16,000 (year 2005),  Design Load: HS 20,  Features Intersected: TH 51 (Snelling Ave)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.20m (17.06ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $556,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $180,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 62539,  Location: 0.2 Mmi E of jct TH 35W (Lat: 45.108333,  Lng: -93.185000),  Route carried "on" structure: County highway 3,  Year Built: 2000,  Status: Open,  Structure Length: 1.56m (5.12ft),  Average Daily Traffic: 6,500 (year 2005),  Design Load: HS 25,  Features Intersected: Rice Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.0m (49.2ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 0.0m,  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 67.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 62569,  Location: 0.5 MI S OF JCT CSAH 73 (Lat: 45.051667,  Lng: -93.188333),  Route carried "on" structure: County highway 46,  Year Built: 2001,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 2,900 (year 2005),  Design Load: HS 25,  Features Intersected: CP RAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Excellent,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 91071,  Location: 0.3 Mi N of S Jct TH 10 (Lat: 45.093603,  Lng: -93.188008),  Route carried "on" structure: Interstate 35W,  Year Built: 1963,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 130,000 (year 2004),  Truck Traffic: 6%,  Design Load: HS 20,  Features Intersected: RICE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 40.8m (133.9ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.2 metric tons,  Inventory Rating: 29.4 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 91072,  Location: 0.1 MI E OF JCT TH 35W (Lat: 45.095414,  Lng: -93.185986),  Route carried "on" structure: City street 106,  Year Built: 1963,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 3,000 (year 1974),  Features Intersected: RICE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 53.9 metric tons,  Inventory Rating: 35.9 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2005,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 9301,  Location: AT THE JCT TH 694 & 51 (Lat: 45.061564,  Lng: -93.158292),  Route carried "on" structure: Interstate 694,  Year Built: 1960,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 58,500 (year 2004),  Truck Traffic: 8%,  Design Load: H 20,  Features Intersected: TH 51 SB ON RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.10m (16.73ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $632,000,  Roadway Improvement Cost: $46,000,  Total Project Cost: $703,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9302,  Location: AT THE JCT TH 694 & 51 (Lat: 45.062517,  Lng: -93.156392),  Route carried "on" structure: Interstate 694,  Year Built: 1960,  Status: Open,  Structure Length: 4.52m (14.83ft),  Average Daily Traffic: 50,500 (year 2004),  Truck Traffic: 9%,  Design Load: HS 20,  Features Intersected: TH 51NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.7m (71.2ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 75.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 931,  Location: AT THE JCT TH 694 & 10 (Lat: 45.066731,  Lng: -93.169722),  Route carried "on" structure: Interstate 694,  Year Built: 1959,  Status: Open,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 39,000 (year 2004),  Truck Traffic: 9%,  Design Load: HS 20+Mod,  Features Intersected: US 10 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.9m (65.3ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.80m (19.03ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $715,000,  Roadway Improvement Cost: $53,000,  Total Project Cost: $796,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9311,  Location: 0.2 MI W OF JCT TH 10 (Lat: 45.066731,  Lng: -93.169722),  Route carried "on" structure: Interstate 694,  Year Built: 1959,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 39,000 (year 2004),  Truck Traffic: 9%,  Design Load: HS 20+Mod,  Features Intersected: CSAH 76
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.4m (60.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9312,  Location: 0.2 MI W OF JCT TH 10 (Lat: 45.066481,  Lng: -93.169669),  Route carried "on" structure: Interstate 694,  Year Built: 1959,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 39,000 (year 2004),  Truck Traffic: 9%,  Design Load: HS 20+Mod,  Features Intersected: CSAH 76
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.4m (60.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9447,  Location: AT THE JCT TH 694 & 51 (Lat: 45.063283,  Lng: -93.158169),  Route carried "on" structure: Ramp State highway 51,  Year Built: 1961,  Status: Open,  Structure Length: 4.62m (15.16ft),  Average Daily Traffic: 5,900 (year 1996),  Design Load: HS 20,  Features Intersected: I 694 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9448,  Location: AT THE JCT TH 694 & 51 (Lat: 45.062517,  Lng: -93.156392),  Route carried "on" structure: Ramp State highway 51,  Year Built: 1961,  Status: Open,  Structure Length: 5.62m (18.44ft),  Average Daily Traffic: 5,900 (year 1996),  Design Load: HS 20+Mod,  Features Intersected: I 694 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.9m (78.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 957,  Location: 0.7 MI S OF JCT TH 694 (Lat: 45.057406,  Lng: -93.187494),  Route carried "on" structure: County highway 73,  Year Built: 1964,  Status: Open,  Structure Length: 6.51m (21.36ft),  Average Daily Traffic: 5,700 (year 2005),  Design Load: HS 20,  Features Intersected: I 35W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.8m (71.5ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.20m (23.62ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $770,000,  Roadway Improvement Cost: $16,000,  Total Project Cost: $249,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9577,  Location: 0.8 MI N OF JCT TH 694 (Lat: 45.079097,  Lng: -93.185358),  Route carried "on" structure: County highway 96,  Year Built: 1963,  Status: Open,  Structure Length: 6.56m (21.52ft),  Truck Traffic: 4%,  Design Load: HS 20,  Features Intersected: I 35W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.7m (71.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 15.7m (51.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 59.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9582,  Location: 0.4 Mi N of S Jct TH 10 (Lat: 45.095408,  Lng: -93.188350),  Route carried "on" structure: City street 106,  Year Built: 1963,  Status: Open,  Structure Length: 6.90m (22.64ft),  Average Daily Traffic: 6,500 (year 1974),  Design Load: HS 20,  Features Intersected: I 35W,  Facility Carried by Structure: TC ARSENAL ENTRY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.6m (77.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 60.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9585,  Location: At the S Jct TH 10 & 35W (Lat: 45.091669,  Lng: -93.187972),  Route carried "on" structure: Ramp US 10,  Year Built: 1963,  Status: Open,  Structure Length: 11.65m (38.22ft),  Average Daily Traffic: 13,500 (year 2003),  Truck Traffic: 6%,  Design Load: HS 20,  Features Intersected: I 35W & 35W SB OFF RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.8m (114.2ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.70m (38.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $1,239,000,  Roadway Improvement Cost: $107,000,  Total Project Cost: $1,611,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9586,  Location: At the S Jct TH 10 & 35W (Lat: 45.088622,  Lng: -93.187967),  Route carried "on" structure: US 10,  Year Built: 1963,  Status: Open,  Structure Length: 13.38m (43.90ft),  Average Daily Traffic: 23,250 (year 2004),  Truck Traffic: 6%,  Design Load: HS 20,  Features Intersected: I 35W & 35W NB OFF RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.9m (127.6ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9599,  Location: 0.2 MI S OF JCT TH 694 (Lat: 45.064558,  Lng: -93.186461),  Route carried "on" structure: City street 108,  Year Built: 1963,  Status: Open,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 4,150 (year 2005),  Design Load: HS 20,  Features Intersected: I 35W & I35W SB ON RAMP,  Facility Carried by Structure: CO RD F(CSAH 12)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.2m (122.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: 9601,  Location: AT THE JCT TH 694 & 35W (Lat: 45.067333,  Lng: -93.185961),  Route carried "on" structure: Interstate 694,  Year Built: 1963,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 54,000 (year 2004),  Truck Traffic: 8%,  Design Load: HS 20,  Features Intersected: I 35W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.2m (102.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.00m (22.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Bridge Improvement Cost: $1,241,000,  Roadway Improvement Cost: $101,000,  Total Project Cost: $1,518,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 9602,  Location: AT THE JCT TH 694 & 35W (Lat: 45.067106,  Lng: -93.186158),  Route carried "on" structure: Interstate 694,  Year Built: 1963,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 54,000 (year 2004),  Truck Traffic: 8%,  Design Load: HS 20,  Features Intersected: I 35W
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.2m (102.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 78.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.00m (22.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Bridge Improvement Cost: $1,241,000,  Roadway Improvement Cost: $101,000,  Total Project Cost: $1,518,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 9603,  Location: 1.3 MI N OF JCT TH 10 (Lat: 45.107950,  Lng: -93.188353),  Route carried "on" structure: Interstate 35W,  Year Built: 1968,  Status: Open,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 130,000 (year 2004),  Truck Traffic: 6%,  Design Load: HS 20+Mod,  Features Intersected: CO RD I(CSAH 3)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.1m (138.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.1m (62.7ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 43.0m (141.1ft),  Out-to-Out Width: 45.2m (148.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: L9232,  Location: 0.3 MI E OF JCT CSAH 49 (Lat: 45.036667,  Lng: -93.173333),  Route carried "on" structure: City street 36,  Year Built: 1968,  Status: Open,  Structure Length: 0.55m (1.80ft),  Average Daily Traffic: 50 (year 1974),  Features Intersected: CO DITCH #
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.2 metric tons,  Inventory Rating: 29.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 62003,  Location: 0.7 MI So OF JCT TH 694 (Lat: 45.052831,  Lng: -93.156625),  Route carried "under" structure: State highway 51,  Year Built: 1961,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 32,000 (year 2004),  Truck Traffic: 2%,  Features Intersected: TH 51,  Facility Carried by Structure: CP RAIL
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 14.8m (48.6ft)

Find on map >>

Structure Number: 6201,  Location: 0.9 Mi So of Jct TH 694 (Lat: 45.050200,  Lng: -93.156631),  Route carried "under" structure: State highway 51,  Year Built: 1961,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 32,000 (year 2004),  Truck Traffic: 2%,  Features Intersected: TH 51 (Snelling Ave),  Facility Carried by Structure: Co Rd E (CSAH 15)
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.2m (76.1ft)

Find on map >>

Structure Number: 656,  Location: 0.2 MI N OF JCT CSAH 15 (Lat: 45.053233,  Lng: -93.164756),  Route carried "under" structure: County highway 76,  Year Built: 1927,  Structure Length: 1.88m (6.17ft),  Average Daily Traffic: 8,300 (year 2005),  Features Intersected: CSAH 76(SNELLING AV),  Facility Carried by Structure: CP RAIL
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 10.3m (33.8ft)

Find on map >>

Structure Number: 90407,  Location: 0.3 MI N OF JCT CSAH 15 (Lat: 45.050733,  Lng: -93.182644),  Route carried "under" structure: County highway 47,  Year Built: 1900,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 2,050 (year 2005),  Features Intersected: CSAH 47,  Facility Carried by Structure: CP RAIL
Minimum Vertical Clearance: 4.33m (14.21ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 8.2m (26.9ft)

Find on map >>

Structure Number: 9301,  Location: AT THE JCT TH 694 & 51 (Lat: 45.061564,  Lng: -93.158292),  Route carried "under" structure: Ramp State highway 51,  Year Built: 1960,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 5,900 (year 1996),  Features Intersected: TH 51 SB ON RAMP,  Facility Carried by Structure: I 694 EB
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>

Structure Number: 9302,  Location: AT THE JCT TH 694 & 51 (Lat: 45.062517,  Lng: -93.156392),  Route carried "under" structure: State highway 51,  Year Built: 1960,  Structure Length: 4.52m (14.83ft),  Average Daily Traffic: 16,000 (year 2004),  Truck Traffic: 2%,  Features Intersected: TH 51NB,  Facility Carried by Structure: I 694 EB
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.7m (71.2ft)

Find on map >>

Structure Number: 931,  Location: AT THE JCT TH 694 & 10 (Lat: 45.066731,  Lng: -93.169722),  Route carried "under" structure: US 10,  Year Built: 1959,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 19,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: US 10 SB,  Facility Carried by Structure: I 694 WB
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.9m (65.3ft)

Find on map >>

Structure Number: 9311,  Location: 0.2 MI W OF JCT TH 10 (Lat: 45.066731,  Lng: -93.169722),  Route carried "under" structure: County highway 76,  Year Built: 1959,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 1,325 (year 2005),  Features Intersected: CSAH 76,  Facility Carried by Structure: I 694 WB
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.4m (60.4ft)

Find on map >>

Structure Number: 9312,  Location: 0.2 MI W OF JCT TH 10 (Lat: 45.066481,  Lng: -93.169669),  Route carried "under" structure: County highway 76,  Year Built: 1959,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 1,325 (year 2005),  Features Intersected: CSAH 76,  Facility Carried by Structure: I 694 EB
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.4m (60.4ft)

Find on map >>

Structure Number: 9447,  Location: AT THE JCT TH 694 & 51 (Lat: 45.063283,  Lng: -93.158169),  Route carried "under" structure: Interstate 694,  Year Built: 1961,  Structure Length: 4.62m (15.16ft),  Average Daily Traffic: 58,500 (year 2004),  Truck Traffic: 8%,  Features Intersected: I 694 WB,  Facility Carried by Structure: TH 51 SB ON RAMP
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>

Structure Number: 9448,  Location: AT THE JCT TH 694 & 51 (Lat: 45.062517,  Lng: -93.156392),  Route carried "under" structure: Interstate 694,  Year Built: 1961,  Structure Length: 5.62m (18.44ft),  Average Daily Traffic: 58,500 (year 2004),  Truck Traffic: 8%,  Features Intersected: I 694 WB,  Facility Carried by Structure: TH 51 NB OFF RAMP
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.9m (78.4ft)

Find on map >>

Structure Number: 957,  Location: 0.7 MI S OF JCT TH 694 (Lat: 45.057406,  Lng: -93.187494),  Route carried "under" structure: Interstate 35W,  Year Built: 1964,  Structure Length: 6.51m (21.36ft),  Average Daily Traffic: 114,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W,  Facility Carried by Structure: CO RD E2 (CSAH 73)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.8m (71.5ft)

Find on map >>

Structure Number: 9575,  Location: 0.2 MI N OF JCT TH 694 (Lat: 45.070339,  Lng: -93.185483),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 7.24m (23.75ft),  Average Daily Traffic: 118,000 (year 2004),  Truck Traffic: 3%,  Features Intersected: I 35W,  Facility Carried by Structure: MC RAIL CO
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.000,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>

Structure Number: 9577,  Location: 0.8 MI N OF JCT TH 694 (Lat: 45.079097,  Lng: -93.185358),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 6.56m (21.52ft),  Average Daily Traffic: 108,000 (year 2004),  Truck Traffic: 3%,  Features Intersected: I 35W,  Facility Carried by Structure: CO RD G(CSAH 96)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.7m (71.2ft)

Find on map >>

Structure Number: 9578,  Location: 1.2 MI N OF JCT TH 694 (Lat: 45.085189,  Lng: -93.186836),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 6.71m (22.01ft),  Average Daily Traffic: 108,000 (year 2004),  Truck Traffic: 3%,  Features Intersected: I 35W,  Facility Carried by Structure: MC RAIL
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 0.000,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>

Structure Number: 9582,  Location: 0.4 Mi N of S Jct TH 10 (Lat: 45.095408,  Lng: -93.188350),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 6.90m (22.64ft),  Average Daily Traffic: 130,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W,  Facility Carried by Structure: TC ARSENAL ENTRY
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.6m (77.4ft)

Find on map >>

Structure Number: 9585,  Location: At the S Jct TH 10 & 35W (Lat: 45.091669,  Lng: -93.187972),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 11.65m (38.22ft),  Average Daily Traffic: 130,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W & 35W SB OFF RAMP,  Facility Carried by Structure: US 10 WB
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: 9585,  Location: At the S Jct TH 10 & 35W (Lat: 45.091669,  Lng: -93.187972),  Route carried "under" structure: Ramp Interstate 35W,  Year Built: 1963,  Structure Length: 11.65m (38.22ft),  Average Daily Traffic: 5,000 (year 1994),  Features Intersected: I 35W & 35W SB OFF RAMP,  Facility Carried by Structure: US 10 WB
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: 9586,  Location: At the S Jct TH 10 & 35W (Lat: 45.088622,  Lng: -93.187967),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 13.38m (43.90ft),  Average Daily Traffic: 13,000 (year 2004),  Truck Traffic: 56%,  Features Intersected: I 35W & 35W NB OFF RAMP,  Facility Carried by Structure: US 10 EB
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.9m (127.6ft)

Find on map >>

Structure Number: 9586,  Location: At the S Jct TH 10 & 35W (Lat: 45.088622,  Lng: -93.187967),  Route carried "under" structure: Ramp Interstate 35W,  Year Built: 1963,  Structure Length: 13.38m (43.90ft),  Average Daily Traffic: 5,000 (year 1994),  Features Intersected: I 35W & 35W NB OFF RAMP,  Facility Carried by Structure: US 10 EB
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 38.9m (127.6ft)

Find on map >>

Structure Number: 9599,  Location: 0.2 MI S OF JCT TH 694 (Lat: 45.064558,  Lng: -93.186461),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 114,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W & I35W SB ON RAMP,  Facility Carried by Structure: CO RD F(CSAH 12)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>

Structure Number: 9599,  Location: 0.2 MI S OF JCT TH 694 (Lat: 45.064558,  Lng: -93.186461),  Route carried "under" structure: Ramp Interstate 35W,  Year Built: 1963,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 5,000 (year 1994),  Features Intersected: I 35W & I35W SB ON RAMP,  Facility Carried by Structure: CO RD F(CSAH 12)
Minimum Vertical Clearance: 4.69m (15.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>

Structure Number: 9601,  Location: AT THE JCT TH 694 & 35W (Lat: 45.067333,  Lng: -93.185961),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 114,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W,  Facility Carried by Structure: I 694 WB
Minimum Vertical Clearance: 4.94m (16.21ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.2m (102.4ft)

Find on map >>

Structure Number: 9602,  Location: AT THE JCT TH 694 & 35W (Lat: 45.067106,  Lng: -93.186158),  Route carried "under" structure: Interstate 35W,  Year Built: 1963,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 114,000 (year 2004),  Truck Traffic: 6%,  Features Intersected: I 35W,  Facility Carried by Structure: I 694 EB
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.2m (102.4ft)

Find on map >>

Structure Number: 9603,  Location: 1.3 MI N OF JCT TH 10 (Lat: 45.107950,  Lng: -93.188353),  Route carried "under" structure: County highway 3,  Year Built: 1968,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 6,500 (year 2005),  Features Intersected: CO RD I(CSAH 3)
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.1m (62.7ft)