National Bridge Inventory (NBI) Statistics
Number of bridges: 19
Total length: 92 meters (302ft)
Total costs: $2,192,000
Total average daily traffic: 103,480
Total average daily truck traffic: 5,460
National Bridge Inventory (NBI) Registered Bridges for Belfast

New bridges - Historical Statistics

  • 1920-1929: 1
  • 1930-1939: 2
  • 1940-1949: 0
  • 1950-1959: 5
  • 1960-1969: 6
  • 1970-1979: 4
  • 1980-1989: 0
  • 1990-1999: 1

Reconstructed bridges - Historical Statistics

  • 1950-1959: 1
  • 1960-1969: 0
  • 1970-1979: 0
  • 1980-1989: 0
  • 1990-1999: 0
  • 2000-2009: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 1123,  Location: .2 MI S RT 137 (Lat: 44.444367,  Lng: -69.061983),  Route carried "on" structure: City street ,  Year Built: 1935,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 310 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 465 (year 2027),  Features Intersected: PASSAGASSAWAKEAG RIVER,  Facility Carried by Structure: SHEPPARD RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.784,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Bridge Improvement Cost: $93,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $140,000 ( Estimate for 2004),  Deck Structure Type: Open Grating
Find on map >>

Structure Number: 1378,  Location: JCT 1+3 (Lat: 44.430000,  Lng: -69.028333),  Route carried "on" structure: State highway 1,  Year Built: 1973,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 8,590 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,026 (year 2027),  Design Load: HS 20,  Features Intersected: RT 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 248.257,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>

Structure Number: 2232,  Location: 1.1 MI S US1 (Lat: 44.405000,  Lng: -69.030833),  Route carried "on" structure: County highway 52,  Year Built: 1955,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 3,270 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,578 (year 2027),  Design Load: H 20,  Features Intersected: LITTLE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.136,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>

Structure Number: 2319,  Location: 1.7 MI E 3 (Lat: 44.432778,  Lng: -68.994722),  Route carried "on" structure: State highway 1,  Year Built: 1934,  Year Reconstructed: 1955,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 13,640 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,096 (year 2027),  Design Load: H 15,  Features Intersected: GOOSE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 251.058,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2008,  Underwater Inspection Date: August 2003
Find on map >>

Structure Number: 2937,  Location: 2.2 MI N US 1 (Lat: 44.443056,  Lng: -69.058611),  Route carried "on" structure: State highway 7,  Year Built: 1952,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 4,260 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,964 (year 2027),  Design Load: H 20,  Features Intersected: PASSAGASSAWAUKEAG RV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.524,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 10.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of replacement,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.68m (5.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2007,  Bridge Improvement Cost: $816,000,  Roadway Improvement Cost: $82,000,  Total Project Cost: $1,224,000 ( Estimate for 2004),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 313,  Location: 1.6 MI N OF US1 UNDERPASS (Lat: 44.450000,  Lng: -69.035000),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 1,200 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,800 (year 2027),  Design Load: H 20,  Features Intersected: PASSAGASSAWAKEAG RIVER,  Facility Carried by Structure: HIGH ST-CITY POINT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.674,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Navigation Control: Yes ( Vertical Clearance: 1.5m (4.9ft), Horizontal Clearance: 9.1m (29.9ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>

Structure Number: 5143,  Location: 0.1 MI. S. JCT. CONGRESS (Lat: 44.398750,  Lng: -69.003633),  Route carried "on" structure: City street ,  Year Built: 1921,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 930 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,395 (year 2027),  Design Load: H 20,  Features Intersected: LITTLE RIVER,  Facility Carried by Structure: HERRICK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.121,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 5243,  Location: 1.1 MI NW'LY JCT RTE 7 (Lat: 64.166667,  Lng: -21.950000),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 800 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,200 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: PASSAGASSAWAUKEAG RIVER,  Facility Carried by Structure: OAK RD (WALDO AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.770,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 5261,  Location: 1.5 MI NW JCT 1 (Lat: 44.450017,  Lng: -69.027683),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 310 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 465 (year 2027),  Features Intersected: WESCOT STREAM,  Facility Carried by Structure: KALER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.933,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Navigation Control: Yes ( Vertical Clearance: 2.7m (8.9ft), Horizontal Clearance: 6.1m (20.0ft)),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006
Find on map >>

Structure Number: 5263,  Location: .8 MI N US 1 (Lat: 44.445278,  Lng: -69.000000),  Route carried "on" structure: County highway 141,  Year Built: 1953,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 6,050 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,470 (year 2027),  Design Load: H 20,  Features Intersected: GOOSE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.255,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 33.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.94m (3.08ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Bridge Improvement Cost: $94,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $141,000 ( Estimate for 2004),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 5264,  Location: 1.6 MI NORTH OF US 1 (Lat: 64.166667,  Lng: -21.950000),  Route carried "on" structure: County highway 141,  Year Built: 1991,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 4,790 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,706 (year 2027),  Design Load: HS 25,  Features Intersected: GOOSE RIVER,  Facility Carried by Structure: HODGDON RD / SA 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.851,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: July 2007,  Underwater Inspection Date: September 2005
Find on map >>

Structure Number: 5557,  Location: 0.9 MI E SHEPART RD (Lat: 64.166667,  Lng: -21.950000),  Route carried "on" structure: County highway ,  Year Built: 1954,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,360 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,040 (year 2027),  Design Load: H 15,  Features Intersected: WARREN BROOK,  Facility Carried by Structure: POORS MILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.607,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 35.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2007
Find on map >>

Structure Number: 5558,  Location: 0.7 MI W JCT SHEPARD RD (Lat: 64.166667,  Lng: -21.950000),  Route carried "on" structure: County highway ,  Year Built: 1955,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 860 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,290 (year 2027),  Design Load: H 15,  Features Intersected: PASSAGASSAWAUKEAG RIVER,  Facility Carried by Structure: POORS MILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.8m (22.3ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: 575,  Location: .7 MI E 3 (Lat: 44.435000,  Lng: -69.010000),  Route carried "on" structure: State highway 1,  Year Built: 1963,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 49.71m (163.09ft),  Average Daily Traffic: 20,420 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 28,588 (year 2027),  Design Load: HS 20,  Features Intersected: PASSAGASSAWAUKEAG + BARR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 249.915,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Navigation Control: Yes ( Vertical Clearance: 20.7m (67.9ft), Horizontal Clearance: 42.1m (138.1ft)),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 46.6m (152.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2006,  Critical Feature Inspection Date: January 2005,  Underwater Inspection Date: June 2003,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 6011,  Location: .7 MI E 3 (Lat: 44.433333,  Lng: -69.016667),  Route carried "on" structure: State highway ,  Year Built: 1963,  Status: Open,  Structure Length: 5.09m (16.70ft),  Average Daily Traffic: 4,530 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,342 (year 2027),  Design Load: HS 20,  Features Intersected: US 1 & 3,  Facility Carried by Structure: HIGH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.982,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.09m (16.70ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008,  Bridge Improvement Cost: $232,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $348,000 ( Estimate for 2004),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>

Structure Number: 6012,  Location: .5 MI E 3 (Lat: 44.431111,  Lng: -69.017778),  Route carried "on" structure: Ramp State highway 7,  Year Built: 1963,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 5,360 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,504 (year 2027),  Design Load: HS 20,  Features Intersected: US 1 & 3,  Facility Carried by Structure: WALDO AVE (100' S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.82m (15.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008,  Bridge Improvement Cost: $226,000,  Roadway Improvement Cost: $23,000,  Total Project Cost: $339,000 ( Estimate for 2004),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>

Structure Number: 1378,  Location: JCT 1+3 (Lat: 44.430000,  Lng: -69.028333),  Route carried "under" structure: State highway 3,  Year Built: 1973,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 12,800 (year 2007),  Truck Traffic: 5%,  Features Intersected: RT 3,  Facility Carried by Structure: US RT 1
Minimum Vertical Clearance: 0.48m (1.57ft),  Kilometerpoint: 71.905,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>

Structure Number: 6011,  Location: .7 MI E 3 (Lat: 44.433333,  Lng: -69.016667),  Route carried "under" structure: State highway 1,  Year Built: 1963,  Structure Length: 5.09m (16.70ft),  Average Daily Traffic: 7,000 (year 2007),  Truck Traffic: 5%,  Features Intersected: US 1 & 3,  Facility Carried by Structure: HIGH STREET
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 249.481,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: 6012,  Location: .5 MI E 3 (Lat: 44.431111,  Lng: -69.017778),  Route carried "under" structure: State highway 1,  Year Built: 1963,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 7,000 (year 2007),  Truck Traffic: 5%,  Features Intersected: US 1 & 3
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 249.271,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Discuss this city on our hugely popular Maine forum

Back to: Belfast, ME, Maine, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.