Bridge Statistics for Bellevue, Illinois (IL) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Bellevue, IL, Illinois, Illinois forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 14 Total length: 119 meters (390ft) Total average daily traffic: 195,600 Total average daily truck traffic: 25,736 National Bridge Inventory (NBI) Registered Bridges for Bellevue
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 72003716426, Location: HARMON HIGHWAY (Lat: 40.681231, Lng: -89.656150), Route carried "on" structure: State highway 116, Year Built: 1935, Year Reconstructed: 1988, Status: Open, Structure Length: 19.45m (63.81ft), Average Daily Traffic: 11,100 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 17,299 (year 2020), Design Load: HS 15, Features Intersected: BN C&NWRR KICKAPOO Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 121.045, Lanes on structure: 4, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 15.8m (51.8ft), Skew: 21 degrees, Material/Design: Steel, Design/Construction: Truss - Deck, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 9, Length of Maximum Span: 42.4m (139.1ft), Curb-To-Curb Width: 18.0m (59.1ft), Out-to-Out Width: 18.9m (62.0ft) Condition: Deck: Satisfactory, Superstructure: Fair, Substructure: Satisfactory, Channel: Good, Operating Rating: 52.2 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 35.1 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Critical Feature Inspection Frequency: Every 24 months, Inspection Date: August 2007, Critical Feature Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 7201192886, Location: 1/2M NORTH BELLEVUE (Lat: 40.693775, Lng: -89.675883), Route carried "on" structure: Other road 671, Year Built: 1978, Status: Open, Structure Length: 8.41m (27.59ft), Average Daily Traffic: 4,600 (year 2002), Average Future Daily Traffic: 5,191 (year 2021), Design Load: HS 20, Features Intersected: I-474 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.124, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 2, Length of Maximum Span: 29.9m (98.1ft), Curb-To-Curb Width: 16.0m (52.5ft), Out-to-Out Width: 16.6m (54.5ft) Condition: Deck: Fair, Superstructure: Good, Substructure: Good, Operating Rating: 63.9 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 38.7 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 72012028861, Location: 0.5M NORTH BELLEVUE (Lat: 40.693869, Lng: -89.675892), Route carried "on" structure: Other road 671, Year Built: 1978, Status: Open, Structure Length: 8.11m (26.61ft), Average Daily Traffic: 4,600 (year 2002), Average Future Daily Traffic: 5,191 (year 2021), Design Load: HS 20, Features Intersected: I-474 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.108, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 2, Length of Maximum Span: 29.9m (98.1ft), Curb-To-Curb Width: 16.3m (53.5ft), Out-to-Out Width: 17.4m (57.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 62.1 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 37.8 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 48 months, Inspection Date: January 2005, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 72012128862, Location: 0.3M E OF MAIN ST (Lat: 40.688481, Lng: -89.676019), Route carried "on" structure: Interstate 474, Year Built: 1978, Status: Open, Structure Length: 5.73m (18.80ft), Average Daily Traffic: 16,900 (year 2007), Truck Traffic: 16%, Average Future Daily Traffic: 19,548 (year 2021), Design Load: HS 20+Mod, Features Intersected: ILL 116 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 6.693, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 37.8m (124.0ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 13.4m (44.0ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 77.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 46.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 72012228863, Location: 0.3 MI E OF MAIN ST (Lat: 40.688361, Lng: -89.675719), Route carried "on" structure: Interstate 474, Year Built: 1978, Status: Open, Structure Length: 6.64m (21.78ft), Average Daily Traffic: 16,900 (year 2007), Truck Traffic: 16%, Average Future Daily Traffic: 19,295 (year 2020), Design Load: HS 20+Mod, Features Intersected: ILL 116 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 6.710, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 2, Length of Maximum Span: 37.8m (124.0ft), Curb-To-Curb Width: 11.7m (38.4ft), Out-to-Out Width: 12.8m (42.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 80.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 46.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 72012328864, Location: IN BELLEVUE (Lat: 40.684239, Lng: -89.675608), Route carried "on" structure: City street 3200, Year Built: 1978, Status: Open, Structure Length: 7.92m (25.98ft), Average Daily Traffic: 900 (year 1999), Truck Traffic: 1%, Average Future Daily Traffic: 1,047 (year 2021), Design Load: HS 20, Features Intersected: I-474, Facility Carried by Structure: CLOSEN RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.644, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 10.4m (34.1ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 2, Length of Maximum Span: 27.1m (88.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 9.1m (29.9ft), Out-to-Out Width: 12.8m (42.0ft) Condition: Deck: Poor, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 56.7 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 72012428865, Location: SCL OF BELLEVUE (Lat: 40.680267, Lng: -89.675419), Route carried "on" structure: Interstate 474, Year Built: 1978, Status: Open, Structure Length: 5.58m (18.31ft), Average Daily Traffic: 16,900 (year 2007), Truck Traffic: 16%, Average Future Daily Traffic: 19,295 (year 2020), Design Load: HS 20+Mod, Features Intersected: C&NW RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 7.578, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.8m (42.0ft), Skew: 1 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 22.9m (75.1ft), Curb-To-Curb Width: 11.6m (38.1ft), Out-to-Out Width: 12.8m (42.0ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 58.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 36.9 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 72201932661, Location: SE CL BELLEVUE (Lat: 40.684864, Lng: -89.667506), Route carried "on" structure: State highway 116, Year Built: 1998, Status: Open, Structure Length: 1.13m (3.71ft), Average Daily Traffic: 6,800 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 10,251 (year 2021), Design Load: HS 20, Features Intersected: KICKAPOO CREEK TRIB Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 119.951, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.0m (36.1ft), Skew: 4 degrees, Material/Design: Concrete, Design/Construction: Frame, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.9m (25.9ft), Curb-To-Curb Width: 9.8m (32.2ft), Out-to-Out Width: 9.8m (32.2ft) Condition: Channel: Very good, Operating Rating: 89.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 63.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 48 months, Inspection Date: October 2005, Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 72003716426, Location: HARMON HIGHWAY (Lat: 40.681231, Lng: -89.656150), Route carried "under" structure: Other road 6576, Year Built: 1935, Structure Length: 19.45m (63.81ft), Average Daily Traffic: 3,100 (year 2002), Features Intersected: BN C&NWRR KICKAPOO, Facility Carried by Structure: ILL 116 Minimum Vertical Clearance: 4.55m (14.93ft), Kilometerpoint: 3.636, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Truss - Deck, Length of Maximum Span: 42.4m (139.1ft) Find on map >>
Structure Number: 7201192886, Location: 1/2M NORTH BELLEVUE (Lat: 40.693775, Lng: -89.675883), Route carried "under" structure: Interstate 474, Year Built: 1978, Structure Length: 8.41m (27.59ft), Average Daily Traffic: 33,800 (year 2007), Truck Traffic: 16%, Features Intersected: I-474, Facility Carried by Structure: FAP 671 SPUR EB Minimum Vertical Clearance: 6.27m (20.57ft), Kilometerpoint: 6.114, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 29.9m (98.1ft) Find on map >>
Structure Number: 72012028861, Location: 0.5M NORTH BELLEVUE (Lat: 40.693869, Lng: -89.675892), Route carried "under" structure: Interstate 474, Year Built: 1978, Structure Length: 8.11m (26.61ft), Average Daily Traffic: 33,800 (year 2007), Truck Traffic: 16%, Features Intersected: I-474, Facility Carried by Structure: FAP 671 SPUR WB Minimum Vertical Clearance: 5.26m (17.26ft), Kilometerpoint: 6.082, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 29.9m (98.1ft) Find on map >>
Structure Number: 72012128862, Location: 0.3M E OF MAIN ST (Lat: 40.688481, Lng: -89.676019), Route carried "under" structure: State highway 116, Year Built: 1978, Structure Length: 5.73m (18.80ft), Average Daily Traffic: 6,200 (year 2007), Truck Traffic: 4%, Features Intersected: ILL 116, Facility Carried by Structure: EB I-474 Minimum Vertical Clearance: 5.38m (17.65ft), Kilometerpoint: 119.179, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 37.8m (124.0ft) Find on map >>
Structure Number: 72012228863, Location: 0.3 MI E OF MAIN ST (Lat: 40.688361, Lng: -89.675719), Route carried "under" structure: State highway 116, Year Built: 1978, Structure Length: 6.64m (21.78ft), Average Daily Traffic: 6,200 (year 2007), Truck Traffic: 4%, Features Intersected: ILL 116, Facility Carried by Structure: WB I-474 Minimum Vertical Clearance: 7.52m (24.67ft), Kilometerpoint: 119.211, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 37.8m (124.0ft) Find on map >>
Structure Number: 72012328864, Location: IN BELLEVUE (Lat: 40.684239, Lng: -89.675608), Route carried "under" structure: Interstate 474, Year Built: 1978, Structure Length: 7.92m (25.98ft), Average Daily Traffic: 33,800 (year 2007), Truck Traffic: 16%, Features Intersected: I-474, Facility Carried by Structure: CLOSEN RD Minimum Vertical Clearance: 7.67m (25.16ft), Kilometerpoint: 7.144, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.1m (88.9ft) Discuss this city on our hugely popular Illinois forum Back to: Bellevue, IL, Illinois, All US cities.
|
![]() |