Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Brigham City, Utah (UT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 246ft / 75.1mTotal length
  • 311,255Total average daily traffic
  • 80,425Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Brigham City
  • No street view available for this location

New bridges in Brigham City, UT - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 101960-1969
  • 21970-1979
  • 41990-1999
  • 22000-2009
  • 52010-2019
Average Bridge Daily Traffic in Brigham City, UT
Average Bridge Truck Traffic in Brigham City, UT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 21.4%Good
  • 42.9%Satisfactory
  • 35.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.1%Very good
  • 35.7%Good
  • 35.7%Satisfactory
  • 21.4%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 28.6%Good
  • 42.9%Satisfactory
  • 14.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 22.2%Very good
  • 33.3%Good
  • 44.4%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Good
  • 80.0%Satisfactory
Find on map >>   Show street view

Structure Number: 3052E,  Location: WEST SIDE OF BRIGHAM CITY (Lat: 41.522333,  Lng: -112.045586),  Route carried "on" structure: City street 1098,  Year Built: 2002,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 1,884 (year 2020),  Average Future Daily Traffic: 2,355 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BOX ELDER CREEK,  Facility Carried by Structure: 1200 WEST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.290,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3064D,  Location: 300 N. 300 E.BRIGHAM CITY (Lat: 41.516742,  Lng: -112.010925),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Posted for load,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 693 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 842 (year 2040),  Design Load: HL 93,  Features Intersected: BOX ELDER CREEK,  Facility Carried by Structure: 300 EAST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.217,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.2m (23.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 29.9m (98.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3076E,  Location: 3 MI. E. OF CENTER AREA (Lat: 41.478831,  Lng: -112.155944),  Route carried "on" structure: County highway 1082,  Year Built: 2010,  Status: Open,  Structure Length: 1.27m (4.17ft),  Average Daily Traffic: 739 (year 2020),  Average Future Daily Traffic: 924 (year 2040),  Design Load: HL 93,  Features Intersected: WHISTLER CANAL,  Facility Carried by Structure: BIRD REFUGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.532,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.3m (10.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2019,  Underwater Inspection Date: July 2019
Find on map >>   Show street view

Structure Number: 3077E,  Location: JUST INSIDE BIRD REFUGE (Lat: 41.509617,  Lng: -112.106778),  Route carried "on" structure: County highway 1082,  Year Built: 2010,  Status: Open,  Structure Length: 2.46m (8.07ft),  Average Daily Traffic: 739 (year 2020),  Average Future Daily Traffic: 924 (year 2040),  Design Load: HL 93,  Features Intersected: REEDER OVERFLOW CHAN.,  Facility Carried by Structure: BIRD REFUGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.236,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 3.3m (10.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 17.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2019
Find on map >>   Show street view

Structure Number: 3078E,  Location: 2.7 MI.NW OF BRIGHAM CITY (Lat: 41.509797,  Lng: -112.077042),  Route carried "on" structure: County highway 1082,  Year Built: 2011,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 739 (year 2020),  Average Future Daily Traffic: 924 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLACK SLOUGH,  Facility Carried by Structure: COUNTY RD, FA#5230
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.718,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.9m (32.5ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: D 383,  Location: NORTHWEST OF BRIGHAM CITY (Lat: 41.534156,  Lng: -112.059311),  Route carried "on" structure: State highway 13,  Year Built: 1935,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 7,539 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 9,424 (year 2040),  Design Load: H 15,  Features Intersected: CHASE SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.409,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: E1349,  Location: WEST OF BRIGHAM CITY (Lat: 41.524722,  Lng: -112.064944),  Route carried "on" structure: Interstate 15,  Year Built: 1965,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 28,705 (year 2020),  Truck Traffic: 31%,  Average Future Daily Traffic: 35,881 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BLACK SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 587.387,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: F 1,  Location: 1.5 Mi N of N Brigham Int (Lat: 41.563081,  Lng: -112.070408),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Open,  Structure Length: 6.66m (21.85ft),  Average Daily Traffic: 500 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 1,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-15 (SR-15) NBL AND SBL,  Facility Carried by Structure: CO RD (CEMENT PL.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.8m (71.5ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F 166,  Location: 1.7 MI.E.of BRIGHAM CITY (Lat: 41.499925,  Lng: -111.990631),  Route carried "on" structure: US 90,  Year Built: 1962,  Year Reconstructed: 1971,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 9,704 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 12,130 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BOX ELDER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.177,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 90NR0,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.6m (28.2ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 39.8m (130.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: F 584,  Location: FOREST ST.INT.W. BRIGHAM (Lat: 41.509858,  Lng: -112.060778),  Route carried "on" structure: County highway 1082,  Year Built: 1995,  Status: Open,  Structure Length: 7.88m (25.85ft),  Average Daily Traffic: 5,549 (year 2020),  Average Future Daily Traffic: 6,936 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I-15 (SR-15) NBL AND SBL,  Facility Carried by Structure: FOREST ST.INT.X-RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.075,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.8m (48.6ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.0m (128.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: F 599,  Location: NORTH SIDE BRIGHAM CITY (Lat: 41.529475,  Lng: -112.022811),  Route carried "on" structure: City street 1086,  Year Built: 1997,  Status: Open,  Structure Length: 4.25m (13.94ft),  Average Daily Traffic: 4,870 (year 2020),  Average Future Daily Traffic: 6,088 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-13,  Facility Carried by Structure: 5TH WEST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.872,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.4m (47.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.1m (69.2ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1C 334,  Location: NORTH BRIGHAM INTERCHANGE (Lat: 41.534981,  Lng: -112.066008),  Route carried "on" structure: Interstate 15,  Year Built: 1967,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 28,705 (year 2020),  Truck Traffic: 31%,  Average Future Daily Traffic: 35,881 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-13 AND UPRR
Minimum Vertical Clearance: 7.88m (25.85ft),  Kilometerpoint: 588.719,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.6m (31.5ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 47.5m (155.8ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1C 451,  Location: 11th SO., BRIGHAM CITY (Lat: 41.486194,  Lng: -112.044211),  Route carried "on" structure: US 91,  Year Built: 1967,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 19,963 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 24,954 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UNION PACIFIC RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.901,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.4m (116.1ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.0m,  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1F 168,  Location: 1.5 MI.EAST BRIGHAM CITY (Lat: 41.499550,  Lng: -111.992706),  Route carried "on" structure: Ramp State highway 90,  Year Built: 1971,  Status: Open,  Structure Length: 9.12m (29.92ft),  Average Daily Traffic: 9,704 (year 2020),  Truck Traffic: 26%,  Average Future Daily Traffic: 12,130 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: US-91 (SR-91) NBL &
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.267,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.9m (98.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3C 334,  Location: NORTH BRIGHAM INTERCHANGE (Lat: 41.535831,  Lng: -112.066450),  Route carried "on" structure: Interstate 15,  Year Built: 1967,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 28,705 (year 2020),  Truck Traffic: 31%,  Average Future Daily Traffic: 35,881 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR-13 AND UPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 588.627,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.6m (31.5ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 47.5m (155.8ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3C 451,  Location: 11TH SO BRIGHAM CITY (Lat: 41.486267,  Lng: -112.042886),  Route carried "on" structure: US 91,  Year Built: 1967,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 19,963 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 24,954 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UNION PACIFIC RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.012,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.4m (116.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 65530-51933,  Location: NEAR JCT I-15 & W. FOREST (Lat: 41.508833,  Lng: -112.069833),  Route carried "on" structure: Federal lands road ,  Year Built: 2002,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 50 (year 2020),  Average Future Daily Traffic: 50 (year 2040),  Features Intersected: EAST SLOUGH,  Facility Carried by Structure: EDUCATION CENTER L
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Owner: Bureau of Fish and Wildlife,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2F 852,  Location: 1100 South Intchg (Lat: 41.485758,  Lng: -112.053503),  Route carried "on" structure: State highway 91,  Year Built: 2013,  Status: Open,  Structure Length: 5.66m (18.57ft),  Average Daily Traffic: 19,963 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 24,954 (year 2040),  Design Load: HL 93,  Features Intersected: I-15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.005,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.8m (91.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4F 852,  Location: 1100 South Intchg (Lat: 41.485692,  Lng: -112.052658),  Route carried "on" structure: State highway 91,  Year Built: 2014,  Status: Open,  Structure Length: 5.66m (18.57ft),  Average Daily Traffic: 19,963 (year 2020),  Truck Traffic: 24%,  Average Future Daily Traffic: 24,954 (year 2040),  Design Load: HL 93,  Features Intersected: I-15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.218,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.8m (91.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: C 147,  Location: 0.8 MI.NO.OF BRIGHAM CITY (Lat: 41.529575,  Lng: -112.029692),  Route carried "under" structure: State highway 13,  Year Built: 1937,  Structure Length: 0. m,  Average Daily Traffic: 4,597 (year 2020),  Truck Traffic: 20%,  Features Intersected: SR-13,  Facility Carried by Structure: UNION PACIFIC RR
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 5.872,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 10.3m (33.8ft)

Find on map >>   Show street view

Structure Number: F 1,  Location: 1.5 Mi N of N Brigham Int (Lat: 41.563081,  Lng: -112.070408),  Route carried "under" structure: Interstate 15,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 26,325 (year 2020),  Truck Traffic: 33%,  Features Intersected: I-15 (SR-15) NBL AND SBL,  Facility Carried by Structure: CO RD (CEMENT PL.)
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 591.357,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.8m (71.5ft)

Find on map >>   Show street view

Structure Number: F 584,  Location: FOREST ST.INT.W. BRIGHAM (Lat: 41.509858,  Lng: -112.060778),  Route carried "under" structure: Interstate 15,  Year Built: 1995,  Structure Length: 0. m,  Average Daily Traffic: 29,544 (year 2020),  Truck Traffic: 29%,  Features Intersected: I-15 (SR-15) NBL AND SBL,  Facility Carried by Structure: FOREST ST.INT.X-RD
Minimum Vertical Clearance: 5.29m (17.36ft),  Kilometerpoint: 585.378,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: F 599,  Location: NORTH SIDE BRIGHAM CITY (Lat: 41.529475,  Lng: -112.022811),  Route carried "under" structure: State highway 13,  Year Built: 1997,  Structure Length: 0. m,  Average Daily Traffic: 4,597 (year 2020),  Truck Traffic: 20%,  Features Intersected: SR-13,  Facility Carried by Structure: 5TH WEST STREET
Minimum Vertical Clearance: 5.07m (16.63ft),  Kilometerpoint: 5.280,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.1m (69.2ft)

Find on map >>   Show street view

Structure Number: 1C 334,  Location: NORTH BRIGHAM INTERCHANGE (Lat: 41.534981,  Lng: -112.066008),  Route carried "under" structure: State highway 13,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 7,539 (year 2020),  Truck Traffic: 22%,  Features Intersected: SR-13 AND UPRR,  Facility Carried by Structure: I-15 (SR-15) NBL
Minimum Vertical Clearance: 7.89m (25.89ft),  Kilometerpoint: 8.979,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.5m (155.8ft)

Find on map >>   Show street view

Structure Number: 1F 168,  Location: 1.5 MI.EAST BRIGHAM CITY (Lat: 41.499550,  Lng: -111.992706),  Route carried "under" structure: Ramp State highway 91,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 20,134 (year 2020),  Truck Traffic: 23%,  Features Intersected: US-91 (SR-91) NBL &,  Facility Carried by Structure: SR-90, EBL RAMP
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 6.254,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>   Show street view

Structure Number: 3C 334,  Location: NORTH BRIGHAM INTERCHANGE (Lat: 41.535831,  Lng: -112.066450),  Route carried "under" structure: State highway 13,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 9,842 (year 2020),  Truck Traffic: 24%,  Features Intersected: SR-13 AND UPRR,  Facility Carried by Structure: I-15 (SR-15) SBL
Minimum Vertical Clearance: 7.87m (25.82ft),  Kilometerpoint: 9.011,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 47.5m (155.8ft)

Discuss Brigham City, Utah (UT) on our hugely popular Utah forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.