National Bridge Inventory (NBI) Statistics
Number of bridges: 18
Total length: 57 meters (187ft)
Total costs: $319,000
Total average daily traffic: 76,875
Total average daily truck traffic: 3,610
National Bridge Inventory (NBI) Registered Bridges for Charleston

New bridges - Historical Statistics

  • 1900-1909: 3
  • 1910-1919: 0
  • 1920-1929: 1
  • 1930-1939: 1
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 4
  • 1970-1979: 3
  • 1980-1989: 2
  • 1990-1999: 2
  • 2000-2009: 2

Reconstructed bridges - Historical Statistics

  • 1950-1959: 1
  • 1960-1969: 0
  • 1970-1979: 1
  • 1980-1989: 2
  • 1990-1999: 2

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 15001503446,  Location: 1.0 MI W CHARLESTON (Lat: 39.484100,  Lng: -88.209328),  Route carried "on" structure: State highway 16,  Year Built: 1961,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 8,450 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,850 (year 2026),  Design Load: HS 20,  Features Intersected: N&S RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 233.595,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 15001603447,  Location: 1.0 MI W CHARLESTON (Lat: 39.484100,  Lng: -88.209139),  Route carried "on" structure: State highway 16,  Year Built: 1961,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 8,450 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,850 (year 2026),  Design Load: HS 20,  Features Intersected: N&S RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 233.611,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 15001703448,  Location: 0.5 MI W CHARLESTON (Lat: 39.484108,  Lng: -88.207461),  Route carried "on" structure: State highway 16,  Year Built: 1961,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 8,450 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,850 (year 2026),  Design Load: HS 20,  Features Intersected: RILEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 233.756,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 28.8m (94.5ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 45.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Critical Feature Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 15001803449,  Location: 0.5 MI W CHARLESTON (Lat: 39.484108,  Lng: -88.207272),  Route carried "on" structure: State highway 16,  Year Built: 1961,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 7.47m (24.51ft),  Average Daily Traffic: 8,450 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,850 (year 2026),  Design Load: HS 20,  Features Intersected: RILEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 233.772,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 28.8m (94.5ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 45.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Critical Feature Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1500270346,  Location: 2.0 MI S CHARLESTON (Lat: 39.462983,  Lng: -88.192758),  Route carried "on" structure: Other road 7643,  Year Built: 1937,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 1,850 (year 2004),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,350 (year 2026),  Design Load: HS 20,  Features Intersected: CASSEL CREEK,  Facility Carried by Structure: FAS 1668
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.473,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 71.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 15004003494,  Location: E EDGE CHARLESTON (Lat: 39.497536,  Lng: -88.163261),  Route carried "on" structure: Other road 7620,  Year Built: 1924,  Year Reconstructed: 1957,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 3,350 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,000 (year 2026),  Design Load: H 20,  Features Intersected: TOWN BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.561,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 43.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>

Structure Number: 15006704865,  Location: 2.5 MI S CHARLESTON (Lat: 39.457728,  Lng: -88.146700),  Route carried "on" structure: State highway 130,  Year Built: 1981,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 5,600 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 7,700 (year 2026),  Design Load: HS 20,  Features Intersected: EMBARRAS RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 139.549,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.0m (75.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 63.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2006,  Underwater Inspection Date: January 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 15201528098,  Location: 700 FT S IL 316 (Lat: 39.495425,  Lng: -88.163589),  Route carried "on" structure: State highway 130,  Year Built: 1979,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 7,800 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 10,400 (year 2026),  Design Load: HS 20,  Features Intersected: TOWN BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 144.553,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 46.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 15500706413,  Location: S EDGE OF LOXA (Lat: 39.491642,  Lng: -88.266542),  Route carried "on" structure: Other road 7635,  Year Built: 1973,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 1,050 (year 2004),  Truck Traffic: 13%,  Average Future Daily Traffic: 1,350 (year 2027),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: CH 28
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.869,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2007,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 15600226971,  Location: CHARLESTON N JACKSON (Lat: 39.493925,  Lng: -88.181769),  Route carried "on" structure: Other road 7642,  Year Built: 1976,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 2,250 (year 2004),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,000 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: TOWN BRANCH CREEK,  Facility Carried by Structure: DIVISION ST(FAU 76
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.290,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 0.0m,  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008
Find on map >>

Structure Number: 15600926969,  Location: CHARLESTON-HARRISON (Lat: 39.493972,  Lng: -88.167558),  Route carried "on" structure: Other road 7649,  Year Built: 1909,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 375 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 500 (year 2027),  Features Intersected: TOWN BRANCH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.586,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.9m (3.0ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 33.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.70m (2.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2005,  Bridge Improvement Cost: $55,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $64,000 ( Estimate for 2006)
Find on map >>

Structure Number: 15601107705,  Location: CHARLESTON SW SIDE (Lat: 39.470575,  Lng: -88.195986),  Route carried "on" structure: Other road 7640,  Year Built: 1984,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,450 (year 2004),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,800 (year 2024),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: DOUGLAS ST(FAU 764
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.947,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2006
Find on map >>

Structure Number: 15601231262,  Location: CHARLESTON-MADISON (Lat: 39.493519,  Lng: -88.186525),  Route carried "on" structure: Other road 7641,  Year Built: 1994,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 5,200 (year 2004),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,500 (year 2024),  Design Load: HS 20,  Features Intersected: TOWN BRANCH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.025,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.8m (12.5ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2008
Find on map >>

Structure Number: 15601330485,  Location: W EDGE CHARLESTON (Lat: 39.491278,  Lng: -88.192392),  Route carried "on" structure: Other road 7614,  Year Built: 1992,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 800 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,100 (year 2024),  Design Load: HS 20,  Features Intersected: TOWN BRANCH CREEK,  Facility Carried by Structure: REYNOLDS DR(MS 854
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.352,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2008,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 15601433515,  Location: CHARLESTON (Lat: 39.492106,  Lng: -88.177178),  Route carried "on" structure: Other road 7643,  Year Built: 2000,  Status: Open,  Structure Length: 1.88m (6.17ft),  Average Daily Traffic: 3,500 (year 2004),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,400 (year 2026),  Design Load: HS 20,  Features Intersected: TOWN BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.418,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2004,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Other Coated Reinforcing
Find on map >>

Structure Number: 15634041976,  Location: E OF DIVISION AVE (Lat: 39.493661,  Lng: -88.181578),  Route carried "on" structure: Other road 7622,  Year Built: 2008,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 550 (year 2004),  Truck Traffic: 3%,  Average Future Daily Traffic: 660 (year 2030),  Design Load: HS 20,  Features Intersected: TOWN BRANCH CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.0m (39.4ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008
Find on map >>

Structure Number: 15990026978,  Location: WEST SIDE CHARLESTON (Lat: 39.493536,  Lng: -88.191269),  Route carried "on" structure: Other road 7614,  Year Built: 1909,  Status: Posted for load,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 800 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,400 (year 2027),  Features Intersected: EI RR,  Facility Carried by Structure: "H" ST (MS 8540)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.030,  Lanes on structure: 1,  Owner: Railroad,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 5.0m (16.4ft),  Out-to-Out Width: 5.4m (17.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Poor,  Operating Rating: 11.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 8.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of replacement,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 4.36m (14.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008,  Bridge Improvement Cost: $170,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $255,000 ( Estimate for 2001),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>

Structure Number: 15990122636,  Location: STATE AVE-CHARLESTON (Lat: 39.497278,  Lng: -88.184294),  Route carried "under" structure: Other road 7619,  Year Built: 1900,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 8,500 (year 2004),  Truck Traffic: 2%,  Features Intersected: SBI 16(FAU 7619),  Facility Carried by Structure: NICKEL PLATE RR
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 1.673,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 14.6m (47.9ft)