Bridge Statistics for Coldwater, Michigan (MI) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Coldwater, MI, Michigan, Michigan forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 13 Total length: 30 meters (98ft) Total average daily traffic: 100,971 Total average daily truck traffic: 9,688 National Bridge Inventory (NBI) Registered Bridges for Coldwater
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 12112021000B03, Location: W LTS OF COLDWATER (Lat: 41.944703, Lng: -85.030914), Route carried "on" structure: US 12, Year Built: 1939, Year Reconstructed: 1997, Status: Open, Structure Length: 2.34m (7.68ft), Average Daily Traffic: 15,902 (year 2003), Truck Traffic: 4%, Average Future Daily Traffic: 17,810 (year 2018), Design Load: HS 25, Features Intersected: COLDWATER RIVER Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 26.202, Lanes on structure: 3, Base Highway Network: Yes (Inventory Route: 92, Subroute: 7), Owner: State Highway Agency, Approaching Roadway Width: 15.2m (49.9ft), Skew: 2 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 23.4m (76.8ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.5m (4.9ft), Curb-To-Curb Width: 15.2m (49.9ft), Out-to-Out Width: 17.8m (58.4ft) Condition: Deck: Good, Superstructure: Excellent, Substructure: Good, Channel: Good, Operating Rating: 77.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 51.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay, Membrane: Epoxy Find on map >>
Structure Number: 12112031000B02, Location: IN COLDWATER (Lat: 41.932344, Lng: -85.004747), Route carried "on" structure: Business Interstate 69, Year Built: 1929, Year Reconstructed: 2002, Status: Open, Structure Length: 0.88m (2.89ft), Average Daily Traffic: 9,218 (year 2003), Truck Traffic: 2%, Average Future Daily Traffic: 11,016 (year 2018), Design Load: HS 25, Features Intersected: SAUK RIVER Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 5.011, Lanes on structure: 4, Base Highway Network: Yes (Inventory Route: 92, Subroute: 2), Owner: State Highway Agency, Approaching Roadway Width: 13.1m (43.0ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 1, Length of Maximum Span: 8.8m (28.9ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 16.5m (54.1ft) Condition: Deck: Good, Superstructure: Excellent, Substructure: Good, Channel: Satisfactory, Operating Rating: 40.9 metric tons, Inventory Rating: 40.9 metric tons, Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 12112033000S1, Location: IN COLDWATER (Lat: 41.936192, Lng: -84.973347), Route carried "on" structure: Interstate 69, Year Built: 1967, Status: Open, Structure Length: 4.54m (14.90ft), Average Daily Traffic: 9,936 (year 2003), Truck Traffic: 35%, Average Future Daily Traffic: 14,258 (year 2018), Design Load: HS 20+Mod, Features Intersected: US-12 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 20.291, Lanes on structure: 2, Lanes under structure: 5, Base Highway Network: Yes (Inventory Route: 92, Subroute: 4), Owner: State Highway Agency, Approaching Roadway Width: 11.8m (38.7ft), Skew: 1 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 25.9m (85.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 12.9m (42.3ft) Condition: Deck: Satisfactory, Superstructure: Fair, Substructure: Good, Operating Rating: 98.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 69.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Better than present minimum criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Latex Concrete Find on map >>
Structure Number: 12112033000S13, Location: IN COLDWATER (Lat: 41.936103, Lng: -84.972775), Route carried "on" structure: Interstate 69, Year Built: 1967, Year Reconstructed: 2002, Status: Open, Structure Length: 4.79m (15.72ft), Average Daily Traffic: 9,936 (year 2003), Truck Traffic: 35%, Average Future Daily Traffic: 14,258 (year 2018), Design Load: HS 25, Features Intersected: US-12 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 20.289, Lanes on structure: 3, Lanes under structure: 5, Base Highway Network: Yes (Inventory Route: 92, Subroute: 7), Owner: State Highway Agency, Approaching Roadway Width: 17.4m (57.1ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 28.5m (93.5ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 16.8m (55.1ft), Out-to-Out Width: 17.8m (58.4ft) Condition: Deck: Good, Superstructure: Excellent, Substructure: Good, Operating Rating: 40.9 metric tons, Inventory Rating: 40.9 metric tons, Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 124144400100B01, Location: NEAR RIVERSIDE DRIVE (Lat: 41.935644, Lng: -85.009872), Route carried "on" structure: City street , Year Built: 1950, Status: Open, Structure Length: 1.00m (3.28ft), Average Daily Traffic: 800 (year 1987), Truck Traffic: 2%, Average Future Daily Traffic: 1,000 (year 2011), Design Load: H 15, Features Intersected: SAUK(COLDWATER) RIVER, Facility Carried by Structure: RACE STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.971, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 11.9m (39.0ft), Skew: 3 degrees, Material/Design: Steel, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.5m (14.8ft), Curb or Sidewalk Widths: Left: 0.9m (3.0ft), Right: 1.2m (3.9ft) Condition: Channel: Good, Culverts: Satisfactory, Operating Rating: 30.0 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 24.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007 Find on map >>
Structure Number: 124144400210B01, Location: IN COLDWATER (Lat: 41.945472, Lng: -85.030614), Route carried "on" structure: City street , Year Built: 1920, Status: Closed, Structure Length: 2.04m (6.69ft), Average Daily Traffic: 500 (year 1987), Average Future Daily Traffic: 600 (year 2011), Design Load: H 20, Features Intersected: COLDWATER RIVER, Facility Carried by Structure: OLD US-12 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.183, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 9.1m (29.9ft), Material/Design: Steel, Design/Construction: Truss - Thru, Number Of Spans In Main Unit: 1, Length of Maximum Span: 19.5m (64.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m, Curb-To-Curb Width: 6.1m (20.0ft), Out-to-Out Width: 6.4m (21.0ft) Condition: Deck: Failed, Superstructure: Failed, Substructure: Serious, Channel: Good, Deck Geometry: High priority of corrective action, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below), Length Of Structure Improvement: 2.04m (6.69ft), Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 124144400380B01, Location: IN COLDWATER (Lat: 41.941119, Lng: -85.020653), Route carried "on" structure: City street 2035, Year Built: 1976, Status: Open, Structure Length: 1.52m (4.99ft), Average Daily Traffic: 2,800 (year 1991), Truck Traffic: 4%, Average Future Daily Traffic: 3,700 (year 2011), Design Load: HS 20, Features Intersected: SAUK (COLDWATER) RIVER, Facility Carried by Structure: BUTTERS AVENUE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.633, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 13.1m (43.0ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 1, Length of Maximum Span: 14.6m (47.9ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 15.9m (52.2ft), Out-to-Out Width: 18.8m (61.7ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 52.7 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 29.1 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Other, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Preformed Fabric Find on map >>
Structure Number: 124144400440B01, Location: IN COLDWATER (Lat: 41.939947, Lng: -85.015017), Route carried "on" structure: City street 2035, Year Built: 1951, Status: Open, Structure Length: 1.12m (3.67ft), Average Daily Traffic: 2,850 (year 1989), Truck Traffic: 4%, Average Future Daily Traffic: 3,500 (year 2011), Design Load: H 15, Features Intersected: SAUK (COLDWATER) RIVER, Facility Carried by Structure: JAY STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.107, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 10.1m (33.1ft), Skew: 1 degrees, Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 10.9m (35.8ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 10.1m (33.1ft), Out-to-Out Width: 12.1m (39.7ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Fair, Channel: Good, Operating Rating: 55.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 124144400490B01, Location: IN COLDWATER (Lat: 41.932878, Lng: -85.005250), Route carried "on" structure: City street 2035, Year Built: 1951, Status: Posted for load, Structure Length: 1.25m (4.10ft), Average Daily Traffic: 1,800 (year 1989), Truck Traffic: 2%, Average Future Daily Traffic: 2,300 (year 2011), Design Load: H 15, Features Intersected: SAUK (COLDWATER) RIVER, Facility Carried by Structure: CLAY STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.138, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 13.1m (43.0ft), Skew: 3 degrees, Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 11.8m (38.7ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 10.1m (33.1ft), Out-to-Out Width: 12.1m (39.7ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Good, Operating Rating: 41.8 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 15.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Meets minimum limits, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below), Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 124144400700B01, Location: IN COLDWATER (Lat: 41.930075, Lng: -84.998817), Route carried "on" structure: City street 2035, Year Built: 1951, Status: Posted for load, Structure Length: 1.06m (3.48ft), Average Daily Traffic: 1,300 (year 1989), Truck Traffic: 1%, Average Future Daily Traffic: 1,600 (year 2011), Design Load: H 15, Features Intersected: SAUK (COLDWATER) RIVER, Facility Carried by Structure: JEFFERSON STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.312, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 11.0m (36.1ft), Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 10.3m (33.8ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 0.9m (3.0ft), Curb-To-Curb Width: 7.0m (23.0ft), Out-to-Out Width: 9.4m (30.8ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Channel: Good, Operating Rating: 35.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 15.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Meets minimum limits, Deck Geometry: High priority of corrective action, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below), Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 124144400780B01, Location: CITY OF COLDWATER (Lat: 41.933067, Lng: -84.990661), Route carried "on" structure: City street 2035, Year Built: 1951, Status: Open, Structure Length: 1.06m (3.48ft), Average Daily Traffic: 3,500 (year 1989), Truck Traffic: 4%, Average Future Daily Traffic: 4,600 (year 2011), Design Load: H 15, Features Intersected: COLDWATER RIVER, Facility Carried by Structure: SPRAGUE STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.741, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 10.1m (33.1ft), Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 10.3m (33.8ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 7.9m (25.9ft), Out-to-Out Width: 10.3m (33.8ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Good, Operating Rating: 52.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 28.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 1.07m (3.51ft), Designated Inspection Frequency: Every 24 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 12112033000S1, Location: IN COLDWATER (Lat: 41.936192, Lng: -84.973347), Route carried "under" structure: US 12, Year Built: 1967, Structure Length: 4.54m (14.90ft), Average Daily Traffic: 21,285 (year 2003), Truck Traffic: 3%, Features Intersected: US-12, Facility Carried by Structure: I-69 SB Minimum Vertical Clearance: 4.88m (16.01ft), Kilometerpoint: 31.086, Lanes on structure: 2, Lanes under structure: 5, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.9m (85.0ft) Find on map >>
Structure Number: 12112033000S13, Location: IN COLDWATER (Lat: 41.936103, Lng: -84.972775), Route carried "under" structure: US 12, Year Built: 1967, Structure Length: 4.79m (15.72ft), Average Daily Traffic: 21,144 (year 2003), Truck Traffic: 4%, Features Intersected: US-12, Facility Carried by Structure: I-69 NB Minimum Vertical Clearance: 0.47m (1.54ft), Kilometerpoint: 31.125, Lanes on structure: 3, Lanes under structure: 5, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Length of Maximum Span: 28.5m (93.5ft) Discuss this city on our hugely popular Michigan forum Back to: Coldwater, MI, Michigan, All US cities.
|
![]() |