U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Coldwater, Michigan (MI) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Coldwater, MI, Michigan, Michigan forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 13
Total length: 30 meters (98ft)
Total average daily traffic: 100,971
Total average daily truck traffic: 9,688
National Bridge Inventory (NBI) Registered Bridges for Coldwater

New bridges - Historical Statistics

  • 1920-1929: 2
  • 1930-1939: 1
  • 1940-1949: 0
  • 1950-1959: 5
  • 1960-1969: 4
  • 1970-1979: 1

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 12112021000B03,  Location: W LTS OF COLDWATER (Lat: 41.944703,  Lng: -85.030914),  Route carried "on" structure: US 12,  Year Built: 1939,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 15,902 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 17,810 (year 2018),  Design Load: HS 25,  Features Intersected: COLDWATER RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.202,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 92,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.4m (76.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Good,  Channel: Good,  Operating Rating: 77.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>

Structure Number: 12112031000B02,  Location: IN COLDWATER (Lat: 41.932344,  Lng: -85.004747),  Route carried "on" structure: Business Interstate 69,  Year Built: 1929,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 9,218 (year 2003),  Truck Traffic: 2%,  Average Future Daily Traffic: 11,016 (year 2018),  Design Load: HS 25,  Features Intersected: SAUK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.011,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 92,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.9 metric tons,  Inventory Rating: 40.9 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 12112033000S1,  Location: IN COLDWATER (Lat: 41.936192,  Lng: -84.973347),  Route carried "on" structure: Interstate 69,  Year Built: 1967,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 9,936 (year 2003),  Truck Traffic: 35%,  Average Future Daily Traffic: 14,258 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: US-12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.291,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 92,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 98.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 69.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 12112033000S13,  Location: IN COLDWATER (Lat: 41.936103,  Lng: -84.972775),  Route carried "on" structure: Interstate 69,  Year Built: 1967,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 9,936 (year 2003),  Truck Traffic: 35%,  Average Future Daily Traffic: 14,258 (year 2018),  Design Load: HS 25,  Features Intersected: US-12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.289,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 92,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.5m (93.5ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Good,  Operating Rating: 40.9 metric tons,  Inventory Rating: 40.9 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 124144400100B01,  Location: NEAR RIVERSIDE DRIVE (Lat: 41.935644,  Lng: -85.009872),  Route carried "on" structure: City street ,  Year Built: 1950,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 800 (year 1987),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,000 (year 2011),  Design Load: H 15,  Features Intersected: SAUK(COLDWATER) RIVER,  Facility Carried by Structure: RACE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.971,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.5m (14.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 30.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007
Find on map >>

Structure Number: 124144400210B01,  Location: IN COLDWATER (Lat: 41.945472,  Lng: -85.030614),  Route carried "on" structure: City street ,  Year Built: 1920,  Status: Closed,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 500 (year 1987),  Average Future Daily Traffic: 600 (year 2011),  Design Load: H 20,  Features Intersected: COLDWATER RIVER,  Facility Carried by Structure: OLD US-12
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.183,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.4m (21.0ft)

Condition: Deck: Failed,  Superstructure: Failed,  Substructure: Serious,  Channel: Good,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 2.04m (6.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 124144400380B01,  Location: IN COLDWATER (Lat: 41.941119,  Lng: -85.020653),  Route carried "on" structure: City street 2035,  Year Built: 1976,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 2,800 (year 1991),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,700 (year 2011),  Design Load: HS 20,  Features Intersected: SAUK (COLDWATER) RIVER,  Facility Carried by Structure: BUTTERS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.633,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 18.8m (61.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 52.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 124144400440B01,  Location: IN COLDWATER (Lat: 41.939947,  Lng: -85.015017),  Route carried "on" structure: City street 2035,  Year Built: 1951,  Status: Open,  Structure Length: 1.12m (3.67ft),  Average Daily Traffic: 2,850 (year 1989),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,500 (year 2011),  Design Load: H 15,  Features Intersected: SAUK (COLDWATER) RIVER,  Facility Carried by Structure: JAY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.107,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 55.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 124144400490B01,  Location: IN COLDWATER (Lat: 41.932878,  Lng: -85.005250),  Route carried "on" structure: City street 2035,  Year Built: 1951,  Status: Posted for load,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 1,800 (year 1989),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,300 (year 2011),  Design Load: H 15,  Features Intersected: SAUK (COLDWATER) RIVER,  Facility Carried by Structure: CLAY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.138,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 124144400700B01,  Location: IN COLDWATER (Lat: 41.930075,  Lng: -84.998817),  Route carried "on" structure: City street 2035,  Year Built: 1951,  Status: Posted for load,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 1,300 (year 1989),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,600 (year 2011),  Design Load: H 15,  Features Intersected: SAUK (COLDWATER) RIVER,  Facility Carried by Structure: JEFFERSON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.312,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 35.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 124144400780B01,  Location: CITY OF COLDWATER (Lat: 41.933067,  Lng: -84.990661),  Route carried "on" structure: City street 2035,  Year Built: 1951,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 3,500 (year 1989),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,600 (year 2011),  Design Load: H 15,  Features Intersected: COLDWATER RIVER,  Facility Carried by Structure: SPRAGUE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.741,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 52.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.07m (3.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 12112033000S1,  Location: IN COLDWATER (Lat: 41.936192,  Lng: -84.973347),  Route carried "under" structure: US 12,  Year Built: 1967,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 21,285 (year 2003),  Truck Traffic: 3%,  Features Intersected: US-12,  Facility Carried by Structure: I-69 SB
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 31.086,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>

Structure Number: 12112033000S13,  Location: IN COLDWATER (Lat: 41.936103,  Lng: -84.972775),  Route carried "under" structure: US 12,  Year Built: 1967,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 21,144 (year 2003),  Truck Traffic: 4%,  Features Intersected: US-12,  Facility Carried by Structure: I-69 NB
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 31.125,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 28.5m (93.5ft)

Discuss this city on our hugely popular Michigan forum

Back to: Coldwater, MI, Michigan, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.