Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Delray Beach, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 63Number of bridges
  • 761ft / 232mTotal length
  • $180,000Total costs
  • 2,884,467Total average daily traffic
  • 203,028Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Delray Beach
  • No street view available for this location

New bridges in Delray Beach, FL - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 31950-1959
  • 101960-1969
  • 21970-1979
  • 61980-1989
  • 141990-1999
  • 262000-2009
  • 12020-2022
Reconstructed bridges in Delray Beach, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 31980-1989
  • 31990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Delray Beach, FL
Average Bridge Truck Traffic in Delray Beach, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 1.9%Excellent
  • 21.2%Very good
  • 71.2%Good
  • 1.9%Satisfactory
  • 3.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.9%Excellent
  • 26.9%Very good
  • 61.5%Good
  • 3.8%Satisfactory
  • 5.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.9%Excellent
  • 23.1%Very good
  • 65.4%Good
  • 7.7%Satisfactory
  • 1.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.8%Excellent
  • 23.8%Very good
  • 59.5%Good
  • 9.5%Satisfactory
  • 2.4%Fair
Find on map >>   Show street view

Structure Number: 930026,  Location: 0.3MI E OF US-1 (Lat: 26.474072,  Lng: -80.062131),  Route carried "on" structure: County highway ,  Year Built: 1949,  Year Reconstructed: 2010,  Status: Posted for load,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 8,368 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,042 (year 2042),  Design Load: H 15,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: G BUSH BLVD(NE8TH)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.554,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Navigation Control: Yes ( Vertical Clearance: 1.8m (5.9ft), Horizontal Clearance: 28.0m (91.9ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 37.6m (123.4ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 23.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 14.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Underwater Inspection Date: May 2021,  Other Special Inspection Date: May 2021,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 930032,  Location: 300' E of FL Turnpike (Lat: 26.453606,  Lng: -80.171797),  Route carried "on" structure: State highway 806,  Year Built: 1965,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 36,500 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 63,328 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: E-2-E Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.269,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.2m (20.3ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 36.3m (119.1ft),  Out-to-Out Width: 37.9m (124.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930064,  Location: Between SR-A1A & SR-5 (Lat: 26.461614,  Lng: -80.064242),  Route carried "on" structure: State highway 806,  Year Built: 1952,  Status: Open,  Structure Length: 7.17m (23.52ft),  Average Daily Traffic: 12,300 (year 2021),  Truck Traffic: 16%,  Average Future Daily Traffic: 21,340 (year 2042),  Design Load: H 15,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: Atlantic Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.186,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Navigation Control: Yes ( Vertical Clearance: 2.4m (7.9ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 16.3m (53.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Load Testing,  Inventory Rating: 22.9 metric tons,  Method Used To Determine Inventory Rating: Load Testing,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Other Special Inspection Date: July 2021,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 930069,  Location: Just W. of Congress Ave. (Lat: 26.459350,  Lng: -80.096483),  Route carried "on" structure: State highway 806,  Year Built: 1966,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 3.89m (12.76ft),  Average Daily Traffic: 37,500 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,062 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: El Rio Canal E-4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.868,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 26.3m (86.3ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.0m (42.7ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 28.8m (94.5ft),  Out-to-Out Width: 33.4m (109.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Underwater Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930184,  Location: 1 mile S of Linton Blvd (Lat: 26.424556,  Lng: -80.090250),  Route carried "on" structure: Interstate 95,  Year Built: 1972,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 114,000 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 197,790 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: C-15 Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.824,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 930215,  Location: 2.0 MI SOUTH OF SR-806 (Lat: 26.423994,  Lng: -80.171664),  Route carried "on" structure: State highway 91,  Year Built: 1956,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 90,100 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 156,324 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LATERAL CANAL #38
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.598,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 33.8m (110.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 33.8m (110.9ft),  Out-to-Out Width: 35.4m (116.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 26.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 20.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.47m (8.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $180,000,  Total Project Cost: $180,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 93024,  Location: 1/2 mile W of SR-809 (Lat: 26.457778,  Lng: -80.130672),  Route carried "on" structure: State highway 806,  Year Built: 1966,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 1.60m (5.25ft),  Average Daily Traffic: 40,500 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 70,268 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: E-3 Canal,  Facility Carried by Structure: West Atlantic Ave.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.488,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.0m (98.4ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 30.0m (98.4ft),  Out-to-Out Width: 34.6m (113.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 52.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930322,  Location: 0.2MI EAST OF US-1 (SR-5) (Lat: 26.439769,  Lng: -80.065208),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 42.39m (139.07ft),  Average Daily Traffic: 20,500 (year 2021),  Truck Traffic: 9%,  Average Future Daily Traffic: 26,400 (year 2042),  Design Load: HS 20,  Features Intersected: INTRACOASTAL WATERWAY,  Facility Carried by Structure: LINTON BLVD.
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 2.512,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 23.7m (77.8ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 7.9m (25.9ft), Horizontal Clearance: 27.9m (91.5ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 19,  Length of Maximum Span: 35.2m (115.5ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 3.6m (11.8ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: July 2020,  Underwater Inspection Date: July 2020,  Other Special Inspection Date: July 2021,  Deck Structure Type: Open Grating
Find on map >>   Show street view

Structure Number: 930442,  Location: 1.3mi. South of Linton (Lat: 26.420678,  Lng: -80.090406),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1993,  Status: Open,  Structure Length: 9.13m (29.95ft),  Average Daily Traffic: 24,000 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 41,640 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: I-95 (SR-9),  Facility Carried by Structure: Peninsula Corp Dr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.259,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.3m (132.2ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Inventory Rating: 63.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930443,  Location: 1.3 mile S of Linton Rd. (Lat: 26.420642,  Lng: -80.090881),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1993,  Status: Open,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 24,000 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 41,640 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CSX Railroad,  Facility Carried by Structure: Peninsula Corp Dr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.211,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 30.2m (99.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 30.2m (99.1ft),  Out-to-Out Width: 31.1m (102.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Inventory Rating: 59.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930444,  Location: 0.85 mile South of Linton (Lat: 26.424556,  Lng: -80.090472),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1993,  Status: Open,  Structure Length: 6.63m (21.75ft),  Average Daily Traffic: 7,700 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,360 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: C-15 Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.080,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930445,  Location: 1 mile S of Linton Blvd (Lat: 26.424556,  Lng: -80.089778),  Route carried "on" structure: Interstate 95,  Year Built: 1993,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 114,000 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 197,790 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: C-15 Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.824,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 33.6m (110.2ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930455,  Location: 2 miles N of Atlantic Ave (Lat: 26.483611,  Lng: -80.084639),  Route carried "on" structure: Interstate 95,  Year Built: 1998,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 179,596 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 311,599 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Lateral Canal 30
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.451,  Lanes on structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 57.9m (190.0ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 61.6m (202.1ft),  Out-to-Out Width: 63.1m (207.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Underwater Inspection Date: October 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 93049,  Location: 2.7 miles N of SR 806 (Lat: 26.499694,  Lng: -80.078792),  Route carried "on" structure: Interstate 95,  Year Built: 2002,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 198,560 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 344,502 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Lake Ida Canal E-4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.300,  Lanes on structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 53.7m (176.2ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 53.7m (176.2ft),  Out-to-Out Width: 55.3m (181.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Underwater Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930495,  Location: E Congress Ave & N SR 806 (Lat: 26.471364,  Lng: -80.088906),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 3.85m (12.63ft),  Average Daily Traffic: 89,798 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 155,800 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Lake Ida Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.059,  Lanes on structure: 5,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.5m (126.3ft),  Curb-To-Curb Width: 26.7m (87.6ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930496,  Location: E Congress Ave & N SR 806 (Lat: 26.471472,  Lng: -80.089167),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 3.85m (12.63ft),  Average Daily Traffic: 89,798 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 155,800 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Lake Ida Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.059,  Lanes on structure: 6,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.5m (126.3ft),  Curb-To-Curb Width: 30.3m (99.4ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930497,  Location: 0.5 mi N of Atlantic Ave (Lat: 26.469283,  Lng: -80.089189),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 6.83m (22.41ft),  Average Daily Traffic: 89,798 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 155,800 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Depot Ave & El Rio Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.805,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.1m (98.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.2m (135.2ft),  Curb-To-Curb Width: 30.1m (98.8ft),  Out-to-Out Width: 31.1m (102.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930498,  Location: 0.5 mi N of Atlantic Ave (Lat: 26.469167,  Lng: -80.089486),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 6.83m (22.41ft),  Average Daily Traffic: 89,798 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 155,800 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Depot Ave & El Rio Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.805,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 30.1m (98.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 41.2m (135.2ft),  Curb-To-Curb Width: 30.1m (98.8ft),  Out-to-Out Width: 31.1m (102.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930499,  Location: 1.5 miles South of SR 806 (Lat: 26.439514,  Lng: -80.089192),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 5.80m (19.03ft),  Average Daily Traffic: 110,000 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 190,850 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CR 782 Linton Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.490,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.6m (87.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 26.7m (87.6ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930501,  Location: I 95 Over Lowson Blvd (Lat: 26.446894,  Lng: -80.090139),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 2.92m (9.58ft),  Average Daily Traffic: 91,750 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 159,186 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SW 10th St. Lowson Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.326,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.7m (87.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.2m (95.8ft),  Curb-To-Curb Width: 30.3m (99.4ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930502,  Location: E Congress Ave & S SR 806 (Lat: 26.446875,  Lng: -80.089811),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 2.92m (9.58ft),  Average Daily Traffic: 91,750 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 159,186 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SW 10th St. Lowson Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.326,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.7m (87.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.2m (95.8ft),  Curb-To-Curb Width: 30.3m (99.4ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930503,  Location: I-95 SR 806 interchange (Lat: 26.461667,  Lng: -80.088681),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 91,750 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 159,186 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 806 W Atlantic Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.978,  Lanes on structure: 6,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.7m (87.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.5m (83.7ft),  Curb-To-Curb Width: 30.3m (99.4ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 89.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 930504,  Location: I-95/SR 806 interchange (Lat: 26.461389,  Lng: -80.088333),  Route carried "on" structure: Interstate 95,  Year Built: 2004,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 91,750 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 159,186 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 806 (Atlantic Ave.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.978,  Lanes on structure: 5,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.7m (87.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.5m (83.7ft),  Curb-To-Curb Width: 26.7m (87.6ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 931007,  Location: 0.25 MI N OF ATLANTIC AVE (Lat: 26.457353,  Lng: -80.176294),  Route carried "on" structure: Ramp State highway 91,  Year Built: 2006,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 2,400 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 4,164 (year 2042),  Design Load: HL 93,  Features Intersected: E-2W CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.372,  Lanes on structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 73.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 931008,  Location: 0.25 MI N OF ATLANTIC AVE (Lat: 26.457153,  Lng: -80.176106),  Route carried "on" structure: Ramp State highway 91,  Year Built: 2006,  Status: Open,  Structure Length: 2.41m (7.91ft),  Average Daily Traffic: 7,050 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 12,232 (year 2042),  Design Load: HL 93,  Features Intersected: E-2W CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.344,  Lanes on structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 931009,  Location: 2.12 MI NORTH OF SR-806 (Lat: 26.483708,  Lng: -80.172569),  Route carried "on" structure: State highway 91,  Year Built: 2006,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 83,000 (year 2021),  Truck Traffic: 13%,  Average Future Daily Traffic: 144,005 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LATERAL CANAL #30
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.249,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 43.9m (144.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 43.9m (144.0ft),  Out-to-Out Width: 45.4m (149.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 80.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 934426,  Location: 1.2 Mi N of Lake Ida Rd. (Lat: 26.483972,  Lng: -80.138944),  Route carried "on" structure: County highway ,  Year Built: 2020,  Status: Open,  Structure Length: 3.57m (11.71ft),  Average Daily Traffic: 6,900 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 11,971 (year 2042),  Design Load: HL 93,  Features Intersected: Canal L-30,  Facility Carried by Structure: El Clair Ranch Rd.
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 3.454,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Underwater Inspection Date: November 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 934427,  Location: 0.5MI W OF MILITARY TRAIL (Lat: 26.475886,  Lng: -80.130708),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 1.84m (6.04ft),  Average Daily Traffic: 2,500 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,337 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD E-3 CANAL,  Facility Carried by Structure: VIA DELRAY BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.819,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.2m (20.3ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 72.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934455,  Location: 0.7MI N OF LAKE IDA ROAD (Lat: 26.483933,  Lng: -80.114517),  Route carried "on" structure: County highway ,  Year Built: 1964,  Status: Open,  Structure Length: 2.76m (9.06ft),  Average Daily Traffic: 9,900 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,176 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD LAT 30 CANAL,  Facility Carried by Structure: BARWICK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.902,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 57.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Underwater Inspection Date: March 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 93447,  Location: 0.4MI S OF LINTON BLVD (Lat: 26.424567,  Lng: -80.092297),  Route carried "on" structure: County highway 807,  Year Built: 1969,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 25,000 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,375 (year 2042),  Design Load: HS 20,  Features Intersected: C-15 CANAL,  Facility Carried by Structure: CONGRESS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.169,  Lanes on structure: 7,  Owner: County Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 28.5m (93.5ft),  Out-to-Out Width: 35.5m (116.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934482,  Location: 0.4 MI W OF CONGRESS AVE (Lat: 26.434153,  Lng: -80.099231),  Route carried "on" structure: City street ,  Year Built: 1988,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,082 (year 2042),  Design Load: HS 20,  Features Intersected: L.W.D.D. E-4 CANAL,  Facility Carried by Structure: OLD GERMANTOWN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.595,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.1m (23.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934483,  Location: 0.8Mi W of JOG/CARTER RD. (Lat: 26.439236,  Lng: -80.156836),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 1.53m (5.02ft),  Average Daily Traffic: 2,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,000 (year 2042),  Design Load: HS 20,  Features Intersected: DIRT FARM ROAD,  Facility Carried by Structure: LINTON BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.3m (50.2ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.0m,  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 16.0m (52.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934911,  Location: 1.1MI S OF LINTON BLVD (Lat: 26.422633,  Lng: -80.076356),  Route carried "on" structure: County highway 811,  Year Built: 1964,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 8,900 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,441 (year 2042),  Design Load: HS 20,  Features Intersected: C-15 CANAL,  Facility Carried by Structure: OLD DIXIE HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.125,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Underwater Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934918,  Location: 1MI S. OF LINTON BLVD (Lat: 26.424183,  Lng: -80.146592),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 33,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 57,255 (year 2042),  Design Load: HS 20,  Features Intersected: L-38 CANAL,  Facility Carried by Structure: JOG ROAD SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.167,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 93493,  Location: 0.8 MI N OF LAKE IDA ROAD (Lat: 26.483797,  Lng: -80.089769),  Route carried "on" structure: County highway 807,  Year Built: 1988,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 25,170 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 31,462 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD LATERAL 30 CANAL,  Facility Carried by Structure: CONGRESS AVE NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.259,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 934931,  Location: 0.8 MI N OF LAKE IDA ROAD (Lat: 26.483803,  Lng: -80.089964),  Route carried "on" structure: County highway 807,  Year Built: 1988,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 29,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 50,315 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD LATERAL 30 CANAL,  Facility Carried by Structure: CONGRESS AVE SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.259,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.0m,  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 934932,  Location: 0.2MI S OF LAKE IDA ROAD (Lat: 26.469078,  Lng: -80.093358),  Route carried "on" structure: County highway 807,  Year Built: 1988,  Status: Open,  Structure Length: 2.30m (7.55ft),  Average Daily Traffic: 33,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 57,255 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD LATERAL 32 CANAL,  Facility Carried by Structure: CONGRESS AVE SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.298,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934933,  Location: 0.2 MI S OF LAKE IDA ROAD (Lat: 26.469067,  Lng: -80.093169),  Route carried "on" structure: County highway 807,  Year Built: 1988,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 33,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 57,255 (year 2042),  Design Load: HS 20,  Features Intersected: LWDD LATERAL 32 CANAL,  Facility Carried by Structure: CONGRESS AVE NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.298,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 934936,  Location: 0.9MI N OF LAKE IDA ROAD (Lat: 26.484014,  Lng: -80.122692),  Route carried "on" structure: County highway 809,  Year Built: 1990,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 33,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 57,255 (year 2042),  Design Load: HS 20,  Features Intersected: L-30 CANAL,  Facility Carried by Structure: MILITARY TRAIL SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.590,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 934937,  Location: 0.9 MI N OF LAKE IDA ROAD (Lat: 26.484011,  Lng: -80.122503),  Route carried "on" structure: County highway 809,  Year Built: 1990,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 33,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 57,255 (year 2042),  Design Load: HS 20,  Features Intersected: L-30 CANAL,  Facility Carried by Structure: MILITARY TRAIL NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.590,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 934938,  Location: 1.9Mi S of WOOLBRIGHT (Lat: 26.483925,  Lng: -80.147258),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 24,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 41,640 (year 2042),  Design Load: HS 25 or greater,  Features Intersected: LWDD L-30 CANAL,  Facility Carried by Structure: JOG ROAD SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.785,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.0m,  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Inventory Rating: 62.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Discuss Delray Beach, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.