U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for East Lansing, Michigan (MI) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: East Lansing, MI, Michigan, Michigan forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 29
Total length: 211 meters (692ft)
Total average daily traffic: 589,138
Total average daily truck traffic: 33,176
National Bridge Inventory (NBI) Registered Bridges for East Lansing

New bridges - Historical Statistics

  • 1920-1929: 2
  • 1930-1939: 0
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 14
  • 1970-1979: 12
  • 1980-1989: 0
  • 1990-1999: 1

Reconstructed bridges - Historical Statistics

  • 1980-1989: 2
  • 1990-1999: 2

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 33133045000B01,  Location: W LTS OF E LANSING (Lat: 42.724022,  Lng: -84.512708),  Route carried "on" structure: Interstate 496,  Year Built: 1970,  Status: Open,  Structure Length: 13.59m (44.59ft),  Average Daily Traffic: 33,720 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,732 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR R & RAMP V
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.448,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 16.1m (52.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 42.6m (139.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $3,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000B02,  Location: W LTS OF E LANSING (Lat: 42.724292,  Lng: -84.512342),  Route carried "on" structure: Interstate 496,  Year Built: 1970,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 12.62m (41.40ft),  Average Daily Traffic: 33,720 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,732 (year 2018),  Design Load: HS 25,  Features Intersected: RED CEDAR R & RAMP V
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.487,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 16.7m (54.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 42.6m (139.8ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 40.9 metric tons,  Inventory Rating: 40.9 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Other Special Inspection Date: October 1994,  Bridge Improvement Cost: $2,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 33133045000R03,  Location: IN EAST LANSING (Lat: 42.720203,  Lng: -84.504767),  Route carried "on" structure: Interstate 496,  Year Built: 1963,  Status: Open,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 33,935 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,953 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CSX RR & TROWBRIDGE RMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.348,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.7m (117.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000R04,  Location: IN EAST LANSING (Lat: 42.720408,  Lng: -84.504122),  Route carried "on" structure: Interstate 496,  Year Built: 1963,  Status: Open,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 33,935 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,953 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CSX RR & TROWBRIDGE RMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.481,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Inventory Rating: 48.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000R05,  Location: IN EAST LANSING (Lat: 42.719261,  Lng: -84.504311),  Route carried "on" structure: Interstate 496,  Year Built: 1963,  Status: Open,  Structure Length: 5.82m (19.09ft),  Average Daily Traffic: 33,935 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,953 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: GTW RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.621,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.3m (83.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Inventory Rating: 43.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $1,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000R06,  Location: IN EAST LANSING (Lat: 42.719264,  Lng: -84.504692),  Route carried "on" structure: Interstate 496,  Year Built: 1963,  Status: Open,  Structure Length: 5.82m (19.09ft),  Average Daily Traffic: 33,935 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,953 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: GTW RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.502,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 88.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $1,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 33133045000R07,  Location: IN EAST LANSING (Lat: 42.719967,  Lng: -84.503839),  Route carried "on" structure: Ramp Interstate 496,  Year Built: 1963,  Status: Open,  Structure Length: 7.98m (26.18ft),  Average Daily Traffic: 5,500 (year 1988),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,750 ,  Design Load: HS 20+Mod,  Features Intersected: CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.076,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 33133045000R08,  Location: IN LANSING (Lat: 42.725078,  Lng: -84.542644),  Route carried "on" structure: Ramp Interstate 496,  Year Built: 1970,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 4,200 (year 1988),  Truck Traffic: 8%,  Average Future Daily Traffic: 3,660 ,  Design Load: HS 20,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.282,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000S05,  Location: IN E LANSING (Lat: 42.723858,  Lng: -84.509242),  Route carried "on" structure: Interstate 496,  Year Built: 1970,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 33,720 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,732 (year 2018),  Design Load: HS 20,  Features Intersected: US-127 RAMP SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.817,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 78.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000S06,  Location: IN E LANSING (Lat: 42.724258,  Lng: -84.508486),  Route carried "on" structure: Interstate 496,  Year Built: 1970,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 33,935 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,953 (year 2018),  Design Load: HS 20,  Features Intersected: US-127 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.876,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.9m (107.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 77.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133045000S16,  Location: IN E LANSING (US127 OFF R (Lat: 42.724269,  Lng: -84.509328),  Route carried "on" structure: Interstate 496,  Year Built: 1970,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 33,720 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 34,732 (year 2018),  Design Load: HS 20,  Features Intersected: US-127 SB RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.807,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 35,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Inventory Rating: 48.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133171000B01,  Location: IN EAST LANSING (Lat: 42.726300,  Lng: -84.509658),  Route carried "on" structure: US 127,  Year Built: 1964,  Status: Open,  Structure Length: 8.04m (26.38ft),  Average Daily Traffic: 25,690 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 28,002 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR R & RAMP V
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.560,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 34,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Inventory Rating: 45.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 33133171000B02,  Location: IN EAST LANSING (Lat: 42.726033,  Lng: -84.510056),  Route carried "on" structure: US 127,  Year Built: 1964,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 25,690 (year 2003),  Truck Traffic: 7%,  Average Future Daily Traffic: 28,002 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR R.& RAMP V
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.502,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 34,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 66.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 334201800038B01,  Location: IN THE CITY OF E. LANSING (Lat: 42.729656,  Lng: -84.493919),  Route carried "on" structure: City street 2003,  Year Built: 1963,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 23,000 (year 1990),  Truck Traffic: 5%,  Average Future Daily Traffic: 33,000 (year 2010),  Design Load: HS 20,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: HARRISON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.820,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 25.2m (82.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 334201800115B01,  Location: .25MILES E OF LANSING (Lat: 42.729425,  Lng: -84.505911),  Route carried "on" structure: City street 2003,  Year Built: 1999,  Status: Open,  Structure Length: 2.81m (9.22ft),  Average Daily Traffic: 7,600 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,950 (year 2018),  Design Load: HS 20,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: KALAMAZOO STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.127,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.4m (76.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Good,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 335201800061B01,  Location: 0.5 MI N OF SHAW LANE MSU (Lat: 42.728033,  Lng: -84.471969),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 11,700 (year 1991),  Truck Traffic: 5%,  Average Future Daily Traffic: 16,750 (year 2011),  Design Load: H 20,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: BOGUE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.274,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 335800599999B01,  Location: MICHIGAN STATE UNIVERSITY (Lat: 42.731717,  Lng: -84.486933),  Route carried "on" structure: State lands road ,  Year Built: 1926,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 2.71m (8.89ft),  Average Daily Traffic: 16,395 (year 1997),  Average Future Daily Traffic: 29,609 ,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: KALAMAZOO @ CIR DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.846,  Lanes on structure: 3,  Owner: State Agenciy,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 3.6m (11.8ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 38.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2005,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 335800599999B02,  Location: MICHIGAN STATE UNIVERSITY (Lat: 42.727694,  Lng: -84.477842),  Route carried "on" structure: State lands road ,  Year Built: 1926,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 11,510 (year 1995),  Truck Traffic: 3%,  Average Future Daily Traffic: 20,788 ,  Features Intersected: RED CEDAR RIVER,  Facility Carried by Structure: FARM LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.575,  Lanes on structure: 3,  Owner: State Agenciy,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 4.2m (13.8ft),  Right: 4.2m (13.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2005,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 33133043000P01,  Location: IN EAST LANSING (Lat: 42.746883,  Lng: -84.473411),  Route carried "under" structure: Business Interstate 69,  Year Built: 1964,  Structure Length: 6.82m (22.38ft),  Average Daily Traffic: 31,908 (year 2003),  Truck Traffic: 2%,  Features Intersected: I-69 BR,  Facility Carried by Structure: PED @HITCH POST RD
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 10.746,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>

Structure Number: 33133043000P02,  Location: IN EAST LANSING (Lat: 42.744564,  Lng: -84.493947),  Route carried "under" structure: Business Interstate 69,  Year Built: 1970,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 28,000 (year 1995),  Truck Traffic: 3%,  Features Intersected: I-69 BR,  Facility Carried by Structure: HARRISON ST
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 4.474,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Length of Maximum Span: 22.2m (72.8ft)

Find on map >>

Structure Number: 33133045000B01,  Location: W LTS OF E LANSING (Lat: 42.724022,  Lng: -84.512708),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1970,  Structure Length: 13.59m (44.59ft),  Average Daily Traffic: 5,000 (year 1974),  Features Intersected: RED CEDAR R & RAMP V
Minimum Vertical Clearance: 4.61m (15.12ft),  Kilometerpoint: 0.365,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>

Structure Number: 33133045000B02,  Location: W LTS OF E LANSING (Lat: 42.724292,  Lng: -84.512342),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1970,  Structure Length: 12.62m (41.40ft),  Average Daily Traffic: 5,000 (year 1974),  Features Intersected: RED CEDAR R & RAMP V
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 0.417,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 42.6m (139.8ft)

Find on map >>

Structure Number: 33133045000R03,  Location: IN EAST LANSING (Lat: 42.720203,  Lng: -84.504767),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1963,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 8,900 (year 1988),  Features Intersected: CSX RR & TROWBRIDGE RMP
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.327,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>

Structure Number: 33133045000R04,  Location: IN EAST LANSING (Lat: 42.720408,  Lng: -84.504122),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1963,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 8,900 (year 1988),  Features Intersected: CSX RR & TROWBRIDGE RMP
Minimum Vertical Clearance: 5.38m (17.65ft),  Kilometerpoint: 0.389,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>

Structure Number: 33133045000S05,  Location: IN E LANSING (Lat: 42.723858,  Lng: -84.509242),  Route carried "under" structure: Ramp US 127,  Year Built: 1970,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 11,500 (year 1974),  Features Intersected: US-127 RAMP SB,  Facility Carried by Structure: I-496 EB
Minimum Vertical Clearance: 0.61m (2.00ft),  Kilometerpoint: 0.182,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Find on map >>

Structure Number: 33133045000S06,  Location: IN E LANSING (Lat: 42.724258,  Lng: -84.508486),  Route carried "under" structure: US 127,  Year Built: 1970,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 25,690 (year 2003),  Truck Traffic: 7%,  Features Intersected: US-127 SB,  Facility Carried by Structure: I-496 WB
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 0.229,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.9m (107.9ft)

Find on map >>

Structure Number: 33133045000S16,  Location: IN E LANSING (US127 OFF R (Lat: 42.724269,  Lng: -84.509328),  Route carried "under" structure: Ramp US 127,  Year Built: 1970,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 28,000 (year 1995),  Truck Traffic: 7%,  Features Intersected: US-127 SB RAMP,  Facility Carried by Structure: I-496 WB
Minimum Vertical Clearance: 0.46m (1.51ft),  Kilometerpoint: 0.135,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.3m (46.9ft)

Find on map >>

Structure Number: 33133171000B01,  Location: IN EAST LANSING (Lat: 42.726300,  Lng: -84.509658),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1964,  Structure Length: 8.04m (26.38ft),  Average Daily Traffic: 200 (year ),  Features Intersected: RED CEDAR R & RAMP V,  Facility Carried by Structure: US-127 NB
Minimum Vertical Clearance: 4.83m (15.85ft),  Kilometerpoint: 0.792,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>

Structure Number: 33133171000B02,  Location: IN EAST LANSING (Lat: 42.726033,  Lng: -84.510056),  Route carried "under" structure: Ramp Interstate 496,  Year Built: 1964,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 200 (year ),  Features Intersected: RED CEDAR R.& RAMP V,  Facility Carried by Structure: US-127 SB
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.748,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Discuss this city on our hugely popular Michigan forum

Back to: East Lansing, MI, Michigan, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.