U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Elk Grove, California (CA) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Elk Grove, CA, California, California forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 16
Total length: 74 meters (243ft)
Total costs: $7,277,000
Total average daily traffic: 176,885
Total average daily truck traffic: 14,147
Total future (year 2028) average daily traffic: 282,509
National Bridge Inventory (NBI) Registered Bridges for Elk Grove

New bridges - Historical Statistics

  • 1930-1939: 1
  • 1940-1949: 2
  • 1950-1959: 1
  • 1960-1969: 2
  • 1970-1979: 4
  • 1980-1989: 3
  • 1990-1999: 1
  • 2000-2009: 2

Reconstructed bridges - Historical Statistics

  • 1970-1979: 1
  • 1980-1989: 1
  • 1990-1999: 2
  • 2000-2009: 3

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 24C0018,  Location: 0.4 MI SW CALVINE RD (Lat: 38.448889,  Lng: -121.280000),  Route carried "on" structure: County highway V565,  Year Built: 1939,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 12,000 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 18,547 (year 2029),  Design Load: H 15,  Features Intersected: EAST BRANCH LAGUNA CREEK,  Facility Carried by Structure: GRANT LINE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C005,  Location: 0.9 MI N OF ELK GROVE BL (Lat: 38.421944,  Lng: -121.370833),  Route carried "on" structure: County highway F038,  Year Built: 1947,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 23,500 (year 2002),  Truck Traffic: 5%,  Average Future Daily Traffic: 26,402 (year 2029),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: ELK GROVE-FLORIN R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 27.0m (88.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.69m (12.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $316,000,  Roadway Improvement Cost: $32,000,  Total Project Cost: $474,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0051,  Location: 0.3 MI S ELK GROVE BLVD (Lat: 38.403333,  Lng: -121.371667),  Route carried "on" structure: County highway F038,  Year Built: 1965,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 23,500 (year 2002),  Truck Traffic: 10%,  Average Future Daily Traffic: 26,402 (year 2029),  Design Load: H 15,  Features Intersected: ELK GROVE CREEK,  Facility Carried by Structure: ELK GRVE-FLORIN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Channel: Excellent,  Culverts: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2007
Find on map >>

Structure Number: 24C0079,  Location: 1.0 MI E GRANT LINE RD (Lat: 38.421944,  Lng: -121.287778),  Route carried "on" structure: County highway V566,  Year Built: 1993,  Status: Open,  Structure Length: 29.35m (96.29ft),  Average Daily Traffic: 11,000 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 16,486 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: DEER CREEK,  Facility Carried by Structure: WILTON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 40,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 29.35m (96.29ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $3,381,000,  Roadway Improvement Cost: $338,000,  Total Project Cost: $5,072,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 24C0087,  Location: 0.5 MI N OF LAGUNA BLVD (Lat: 38.430361,  Lng: -121.398833),  Route carried "on" structure: County highway ,  Year Built: 1956,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 755 (year 1999),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,966 (year 2028),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: W STOCKTON BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.3m (27.2ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 5.5m (18.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.45m (14.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2006,  Bridge Improvement Cost: $377,000,  Roadway Improvement Cost: $38,000,  Total Project Cost: $566,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0158,  Location: 0.2 MI S ELK GROVE BLVD (Lat: 38.406944,  Lng: -121.450000),  Route carried "on" structure: County highway F076,  Year Built: 2003,  Status: Open,  Structure Length: 1.72m (5.64ft),  Average Daily Traffic: 6,440 (year 2006),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,805 (year 2028),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: FRANKLIN BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.0m (85.3ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.8m (9.2ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 26.0m (85.3ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.74m (5.71ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2006,  Bridge Improvement Cost: $141,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $211,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0193,  Location: 0.5 MI EAST OF S.R. 99 (Lat: 38.408889,  Lng: -121.377778),  Route carried "on" structure: County highway V567,  Year Built: 1976,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 26,170 (year 1991),  Truck Traffic: 10%,  Average Future Daily Traffic: 74,072 (year 2029),  Design Load: HS 20,  Features Intersected: ELK GROVE CREEK,  Facility Carried by Structure: ELK GROVE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 23.3m (76.4ft),  Out-to-Out Width: 27.0m (88.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0248,  Location: 0.4 MI N SHELDON RD (Lat: 38.443889,  Lng: -121.325000),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 1,180 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,442 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: EAST BRANCH LAGUNA CREEK,  Facility Carried by Structure: BADER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 24C0285,  Location: EAST WATERMAN RD (Lat: 38.423889,  Lng: -121.351667),  Route carried "on" structure: County highway ,  Year Built: 1981,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 4,720 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,182 (year 2029),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: BOND RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 33.8m (110.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 28.4m (93.2ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0286,  Location: SOUTH OF BOND RD (Lat: 38.423889,  Lng: -121.352778),  Route carried "on" structure: County highway ,  Year Built: 1981,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 650 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,237 (year 2029),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: WATERMAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0308,  Location: BRADSHAW RD & SHELDON RD (Lat: 38.437778,  Lng: -121.335000),  Route carried "on" structure: Business County highway F075,  Year Built: 1940,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 10,000 (year 2002),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,456 (year 2029),  Features Intersected: E BRANCH LAGUNA CREEK,  Facility Carried by Structure: BRADSHAW & SHELDON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.5m (31.2ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 27.5 metric tons,  Inventory Rating: 20.7 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.65m (5.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Bridge Improvement Cost: $484,000,  Roadway Improvement Cost: $48,000,  Total Project Cost: $725,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C038,  Location: 0.18 MI W ELK GR FLORIN R (Lat: 38.423889,  Lng: -121.375000),  Route carried "on" structure: County highway G326,  Year Built: 1972,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 17,400 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 28,288 (year 2029),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: BOND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.8m (68.2ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.0m (65.6ft),  Out-to-Out Width: 27.0m (88.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0381,  Location: 0.1 MI N ELK GROVE BLVD (Lat: 38.410833,  Lng: -121.383889),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 11,470 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,458 (year 2029),  Design Load: HS 20,  Features Intersected: ELK GROVE CREEK,  Facility Carried by Structure: EMERALD VISTA DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 2.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 24C0405,  Location: 0.15 MI S SHELDON RD (Lat: 38.435028,  Lng: -121.417750),  Route carried "on" structure: County highway ,  Year Built: 1970,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.12m (23.36ft),  Average Daily Traffic: 6,000 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,702 (year 2028),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: BRUCEVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 24.2m (79.4ft),  Out-to-Out Width: 27.6m (90.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 24C0428,  Location: 0.2 MI E SHELDON WOODS RD (Lat: 38.440000,  Lng: -121.290000),  Route carried "on" structure: County highway V565,  Year Built: 1960,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 12,000 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 20,608 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: DRAINAGE CANAL,  Facility Carried by Structure: GRANT LINE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 53.2 metric tons,  Inventory Rating: 32.6 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.30m (4.27ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2007,  Bridge Improvement Cost: $153,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $229,000
Find on map >>

Structure Number: 24C0512,  Location: 1.2 M EO ELK GROVE FLORIN (Lat: 38.438056,  Lng: -121.348889),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 10,100 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,456 (year 2029),  Design Load: HS 20,  Features Intersected: LAGUNA CREEK,  Facility Carried by Structure: SHELDON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.9m (32.5ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.6m (28.2ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 55.1 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place

Discuss this city on our hugely popular California forum

Back to: Elk Grove, CA, California, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.