U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Euclid, Ohio (OH) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Euclid, OH, Ohio, Ohio forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 30
Total length: 152 meters (499ft)
Total costs: $1,000,000
Total average daily traffic: 1,040,375
Total average daily truck traffic: 55,118
National Bridge Inventory (NBI) Registered Bridges for Euclid

New bridges - Historical Statistics

  • 1900-1909: 1
  • 1910-1919: 2
  • 1920-1929: 1
  • 1930-1939: 0
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 20
  • 1970-1979: 3
  • 1980-1989: 1
  • 1990-1999: 0
  • 2000-2009: 2

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 1801082,  Location: APPROX 500FT E DILLE RD (Lat: 41.568281,  Lng: -81.535947),  Route carried "on" structure: US 6,  Year Built: 1902,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 17,640 (year 2004),  Truck Traffic: 2%,  Average Future Daily Traffic: 24,484 (year 2027),  Design Load: H 15,  Features Intersected: OLD2589-EUCLID CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.850,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 29.4m (96.5ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $500,000,  Roadway Improvement Cost: $500,000,  Total Project Cost: $1,000,000 ( Estimate for 2000),  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587558,  Lng: -81.526322),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 7.04m (23.10ft),  Average Daily Traffic: 114,944 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 159,542 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: CR-44 (E 222 ST)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.340,  Lanes on structure: 8,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 50.0m (164.0ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 50.0m (164.0ft),  Out-to-Out Width: 50.6m (166.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.595208,  Lng: -81.513219),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 114,944 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 159,542 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: CR-116 (BABBITT RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.720,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 42.7m (140.1ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1809008,  Location: IR90 AND SR175 JCT (Lat: 41.601642,  Lng: -81.502450),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 122,170 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 169,572 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR 175 (1446) E 260 ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 46.850,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 42.7m (140.1ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 42.7m (140.1ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1809067,  Location: .12 MI E OF SR175 (Lat: 41.602658,  Lng: -81.500625),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 61,085 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 84,786 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: N.LAKELAND BLVD CONNECTO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.040,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 1809091,  Location: .12 MI E OF JCT SR 175 (Lat: 41.602658,  Lng: -81.500625),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 61,085 (year 2004),  Truck Traffic: 6%,  Average Future Daily Traffic: 84,786 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: N.LAKELAND BLVD CONNECTO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.040,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 1809164,  Location: 4 MI W OF SR 640 (Lat: 41.604497,  Lng: -81.495328),  Route carried "on" structure: Interstate 90,  Year Built: 2006,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 47,115 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,396 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SR-2 EB & SR-2 RAMP SE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.590,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.6m (100.4ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 32.4 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 180918,  Location: 4.5 MI W SR 640 (Lat: 41.605478,  Lng: -81.494714),  Route carried "on" structure: Ramp State highway 2,  Year Built: 1963,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 1,000 (year 2002),  Average Future Daily Traffic: 1,388 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: RMP(WB 2 TO EB 90)OV SR2
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 46.450,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.5m (31.2ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 180921,  Location: .59 MI E OF JCT SR175 (Lat: 41.603894,  Lng: -81.493106),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 8.84m (29.00ft),  Average Daily Traffic: 47,115 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,396 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: LAKELAND BLVD & CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.800,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 35.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up
Find on map >>

Structure Number: 1809245,  Location: .59 MI E OF JCT SR 175 (Lat: 41.603894,  Lng: -81.493106),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 47,115 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,396 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: LAKELAND BLVD & CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.800,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 23.6m (77.4ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 31.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Built-up
Find on map >>

Structure Number: 1809334,  Location: .79 MI E OF JCT SR175 (Lat: 41.601794,  Lng: -81.490544),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 47,115 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,396 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: NSC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.120,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Built-up
Find on map >>

Structure Number: 1809369,  Location: .79 MI E OF JCT SR 175 (Lat: 41.601794,  Lng: -81.490544),  Route carried "on" structure: Interstate 90,  Year Built: 1963,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 47,115 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 65,396 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: NSC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.120,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Built-up
Structure Number: 1830325,  Location: 590 FT SE OF EUCLID AVE,  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 22,427 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 31,129 (year 2026),  Design Load: HS 20,  Features Intersected: EUCLID CRK/HIGHLAND #156
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Structure Number: 1830333,  Location: 1592 FT SE OF EUCLID AVE,  Route carried "on" structure: County highway 47,  Year Built: 1968,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 22,427 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 31,129 (year 2026),  Design Load: HS 20,  Features Intersected: EUCLID CRK/HIGHLAND #157
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Structure Number: 1830341,  Location: 2052 FT SE OF EUCLID AVE,  Route carried "on" structure: County highway 47,  Year Built: 1968,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 18,938 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 26,286 (year 2026),  Design Load: HS 20,  Features Intersected: EUCLID CRK/HIGHLAND #158
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place
Structure Number: 1830368,  Location: 3305 FT SE OF EUCLID AVE,  Route carried "on" structure: County highway 47,  Year Built: 1968,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 18,938 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 26,286 (year 2026),  Design Load: HS 20,  Features Intersected: E BR ECLD CRK/HGHLND #22
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Serious,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 1808915,  Location: 1.56 MI W OF JCT SR175 (Lat: 41.587558,  Lng: -81.526322),  Route carried "under" structure: County highway 44,  Year Built: 1963,  Structure Length: 7.04m (23.10ft),  Average Daily Traffic: 14,300 (year 1963),  Features Intersected: I-90,  Facility Carried by Structure: IR90 OVER E-222ND
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.024,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>

Structure Number: 1808974,  Location: .70 MI W OF JCT SR175 (Lat: 41.595208,  Lng: -81.513219),  Route carried "under" structure: County highway 116,  Year Built: 1963,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 8,140 (year 1971),  Features Intersected: I-90,  Facility Carried by Structure: IR90
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 0.127,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>

Structure Number: 1809008,  Location: IR90 AND SR175 JCT (Lat: 41.601642,  Lng: -81.502450),  Route carried "under" structure: State highway 175,  Year Built: 1963,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 8,310 (year 2004),  Truck Traffic: 1%,  Features Intersected: I-90,  Facility Carried by Structure: IR90 OVER E. 260TH
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 2.328,  Lanes on structure: 8,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.9m (62.0ft)

Find on map >>

Structure Number: 1809067,  Location: .12 MI E OF SR175 (Lat: 41.602658,  Lng: -81.500625),  Route carried "under" structure: City street LAKLD,  Year Built: 1963,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 1,000 (year 2004),  Features Intersected: I-90WB & SR-2WB (ONLY),  Facility Carried by Structure: IR90-WB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>

Structure Number: 1809091,  Location: .12 MI E OF JCT SR 175 (Lat: 41.602658,  Lng: -81.500625),  Route carried "under" structure: City street LAKLD,  Year Built: 1963,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 1,000 (year 2004),  Features Intersected: I-90EB & SR-2EB (ONLY),  Facility Carried by Structure: IR90-EB
Minimum Vertical Clearance: 0.46m (1.51ft),  Kilometerpoint: 0.002,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>

Structure Number: 1809164,  Location: 4 MI W OF SR 640 (Lat: 41.604497,  Lng: -81.495328),  Route carried "under" structure: Ramp State highway 2,  Year Built: 2006,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 94,810 (year 2004),  Truck Traffic: 4%,  Features Intersected: IR-90WB UP, SR-2 DOWN,  Facility Carried by Structure: IR-90 WB
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 4.585,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.6m (100.4ft)

Find on map >>

Structure Number: 180918,  Location: 4.5 MI W SR 640 (Lat: 41.605478,  Lng: -81.494714),  Route carried "under" structure: State highway 2,  Year Built: 1963,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 1,000 (year 2002),  Features Intersected: SR2 WB TOGO IR90 EB
Minimum Vertical Clearance: 0.45m (1.48ft),  Kilometerpoint: 4.585,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>

Structure Number: 1809903,  Location: .5 MI S I-90 (Lat: 41.594006,  Lng: -81.502814),  Route carried "under" structure: State highway 175,  Year Built: 1975,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 15,620 (year 2004),  Truck Traffic: 3%,  Features Intersected: NSC RR NORTH OF TUNGSTEN,  Facility Carried by Structure: NSC RR
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 2.231,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>

Structure Number: 1809938,  Location: .2 MI S I-90 (Lat: 41.598483,  Lng: -81.502883),  Route carried "under" structure: State highway 175,  Year Built: 1974,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 15,620 (year 2004),  Truck Traffic: 3%,  Features Intersected: CSX RR SOUTH OF IR-90,  Facility Carried by Structure: CSX RR
Minimum Vertical Clearance: 0.46m (1.51ft),  Kilometerpoint: 2.281,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.5m (50.9ft)

Structure Number: 1840037,  Location: NO DATA,  Route carried "under" structure: County highway 116,  Year Built: 1978,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 17,518 (year 1994),  Truck Traffic: 5%,  Features Intersected: BABBITT RD/CONRAIL #3R,  Facility Carried by Structure: NO DATA
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Structure Number: 1840223,  Location: NO DATA,  Route carried "under" structure: County highway 114,  Year Built: 1910,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 6,441 (year 1991),  Truck Traffic: 3%,  Features Intersected: EAST 200 ST/CONRAIL #22R,  Facility Carried by Structure: NO DATA
Minimum Vertical Clearance: 3.86m (12.66ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 9.8m (32.2ft)

Structure Number: 1840231,  Location: NO DATA,  Route carried "under" structure: County highway 44,  Year Built: 1910,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 14,265 (year 1994),  Truck Traffic: 5%,  Features Intersected: EAST 222 ST/N&W RR #23R,  Facility Carried by Structure: NO DATA
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Frame,  Length of Maximum Span: 30.2m (99.1ft)

Structure Number: 1840258,  Location: NO DATA,  Route carried "under" structure: County highway 44,  Year Built: 1927,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 16,783 (year 1994),  Truck Traffic: 5%,  Features Intersected: EAST 222 ST/CONRAIL #25R,  Facility Carried by Structure: NO DATA
Minimum Vertical Clearance: 4.17m (13.68ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 14.0m (45.9ft)

Structure Number: 1840673,  Location: NO DATA,  Route carried "under" structure: County highway 116,  Year Built: 1981,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 14,395 (year 1994),  Truck Traffic: 3%,  Features Intersected: BABBITT RD/N&W RR #67R,  Facility Carried by Structure: NO DATA
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.3m (69.9ft)

Discuss this city on our hugely popular Ohio forum

Back to: Euclid, OH, Ohio, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.