Bridge Statistics for Farmington Hills, Michigan (MI) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Farmington Hills, MI, Michigan, Michigan forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 30 Total length: 259 meters (850ft) Total costs: $11,000 Total average daily traffic: 1,740,472 Total average daily truck traffic: 105,072 National Bridge Inventory (NBI) Registered Bridges for Farmington Hills
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 63163022000C03, Location: 2.0 MI SE OF FARMINGTON (Lat: 42.451603, Lng: -83.351822), Route carried "on" structure: Interstate 96, Year Built: 1956, Status: Open, Structure Length: 1.09m (3.58ft), Average Daily Traffic: 20,126 (year 2003), Truck Traffic: 3%, Average Future Daily Traffic: 20,730 (year 2018), Design Load: HS 20, Features Intersected: UPPER ROUGE RIVER Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 28.138, Lanes on structure: 5, Base Highway Network: Yes (Inventory Route: 65, Subroute: 3), Owner: State Highway Agency, Approaching Roadway Width: 20.7m (67.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 10.0m (32.8ft), Out-to-Out Width: 10.9m (35.8ft) Condition: Channel: Poor, Culverts: Good, Operating Rating: 32.7 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.7 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2005 Find on map >>
Structure Number: 63163022000S1, Location: 2MI W OF FARMINGTON (Lat: 42.468364, Lng: -83.417175), Route carried "on" structure: Business Interstate 96, Year Built: 1957, Status: Open, Structure Length: 7.50m (24.61ft), Average Daily Traffic: 47,283 (year 2003), Truck Traffic: 1%, Average Future Daily Traffic: 50,120 (year 2018), Design Load: H 20, Features Intersected: M-5 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 23.257, Lanes on structure: 4, Lanes under structure: 4, Base Highway Network: Yes (Inventory Route: 410, Subroute: 42), Owner: State Highway Agency, Approaching Roadway Width: 17.0m (55.8ft), Skew: 1 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 20.7m (67.9ft), Curb or Sidewalk Widths: Left: 0.9m (3.0ft), Right: 0.9m (3.0ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 17.2m (56.4ft) Condition: Deck: Satisfactory, Superstructure: Fair, Substructure: Fair, Operating Rating: 63.6 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 29.1 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: High priority of replacement, Underclear: High priority of corrective action, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 63163022000S11, Location: 4.0 MI NW OF WAYNE CO LIN (Lat: 42.459144, Lng: -83.395675), Route carried "on" structure: City street , Year Built: 1957, Status: Open, Structure Length: 4.17m (13.68ft), Average Daily Traffic: 7,500 (year 1994), Truck Traffic: 3%, Average Future Daily Traffic: 11,000 (year 2007), Design Load: H 15, Features Intersected: M-5, Facility Carried by Structure: DRAKE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.509, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Skew: 1 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 21.0m (68.9ft), Curb or Sidewalk Widths: Left: 0.9m (3.0ft), Right: 0.9m (3.0ft), Curb-To-Curb Width: 7.9m (25.9ft), Out-to-Out Width: 10.4m (34.1ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 57.3 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 26.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of replacement, Underclear: High priority of replacement, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2008, Bridge Improvement Cost: $1,000, Total Project Cost: $1,000, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163022000S14, Location: 0.2 MI E. OF FARMINGTON (Lat: 42.451275, Lng: -83.346236), Route carried "on" structure: State highway 5, Year Built: 1957, Year Reconstructed: 1997, Status: Open, Structure Length: 6.82m (22.38ft), Average Daily Traffic: 10,063 (year 2003), Truck Traffic: 3%, Average Future Daily Traffic: 10,365 (year 2018), Design Load: HS 20, Features Intersected: GRAND RIVER EB CONN Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 28.637, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes (Inventory Route: 65, Subroute: 4), Owner: State Highway Agency, Approaching Roadway Width: 12.8m (42.0ft), Skew: 5 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 23.7m (77.8ft), Curb-To-Curb Width: 14.8m (48.6ft), Out-to-Out Width: 15.8m (51.8ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 95.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 57.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 63163101000S02, Location: 0.5 MI NE OF I-96 (Lat: 42.483489, Lng: -83.435658), Route carried "on" structure: County highway 2059, Year Built: 1961, Year Reconstructed: 2001, Status: Open, Structure Length: 8.84m (29.00ft), Average Daily Traffic: 20,000 (year 1974), Truck Traffic: 3%, Average Future Daily Traffic: 20,000 , Design Load: H 15, Features Intersected: I-696, Facility Carried by Structure: HAGGERTY RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 5.003, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes (Inventory Route: 63, Subroute: 5), Owner: State Highway Agency, Approaching Roadway Width: 10.3m (33.8ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 21.6m (70.9ft), Curb or Sidewalk Widths: Left: 0.7m (2.3ft), Right: 0.7m (2.3ft), Curb-To-Curb Width: 7.9m (25.9ft), Out-to-Out Width: 10.0m (32.8ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 67.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 49.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: Febuary 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163101000S03, Location: 1.7 MI NE OF I-96 (Lat: 42.491681, Lng: -83.416889), Route carried "on" structure: City street , Year Built: 1962, Status: Open, Structure Length: 8.07m (26.48ft), Average Daily Traffic: 15,000 (year 1996), Truck Traffic: 3%, Average Future Daily Traffic: 20,764 (year 2007), Design Load: H 20, Features Intersected: I-696, Facility Carried by Structure: HALSTEAD RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.747, Lanes on structure: 2, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 10.9m (35.8ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 22.8m (74.8ft), Curb or Sidewalk Widths: Left: 0.7m (2.3ft), Right: 0.7m (2.3ft), Curb-To-Curb Width: 7.9m (25.9ft), Out-to-Out Width: 10.0m (32.8ft) Condition: Deck: Poor, Superstructure: Fair, Substructure: Poor, Inventory Rating: 45.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Meets minimum limits, Deck Geometry: High priority of corrective action, Underclear: Meets minimum limits, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 15 months, Inspection Date: December 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163101000S04, Location: 2.7MI E OF I-96 OVER DRAK (Lat: 42.493972, Lng: -83.397467), Route carried "on" structure: Interstate 696, Year Built: 1960, Year Reconstructed: 1988, Status: Open, Structure Length: 3.32m (10.89ft), Average Daily Traffic: 170,558 (year 2003), Truck Traffic: 6%, Average Future Daily Traffic: 173,116 (year 2018), Design Load: HS 20+Mod, Features Intersected: DRAKE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 4.207, Lanes on structure: 8, Lanes under structure: 2, Base Highway Network: Yes (Inventory Route: 71, Subroute: 1), Owner: State Highway Agency, Approaching Roadway Width: 36.2m (118.8ft), Skew: 30 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 12.5m (41.0ft), Curb-To-Curb Width: 42.7m (140.1ft), Out-to-Out Width: 43.6m (143.0ft) Condition: Deck: Satisfactory, Superstructure: Fair, Substructure: Satisfactory, Operating Rating: 61.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 36.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Superior to present desirable criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Latex Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 63163101000S06, Location: 3.7 MI E OF I-96 (Lat: 42.495061, Lng: -83.378061), Route carried "on" structure: City street 2059, Year Built: 1962, Year Reconstructed: 1997, Status: Open, Structure Length: 7.86m (25.79ft), Average Daily Traffic: 19,600 (year 1996), Truck Traffic: 5%, Average Future Daily Traffic: 27,130 (year 2007), Design Load: HS 20, Features Intersected: I-696, Facility Carried by Structure: FARMINGTON RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.396, Lanes on structure: 2, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 10.9m (35.8ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 18.3m (60.0ft), Curb or Sidewalk Widths: Left: 1.2m (3.9ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 9.6m (31.5ft), Out-to-Out Width: 10.6m (34.8ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 78.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 64.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163101000S07, Location: 4.7 MI E OF I-96 (Lat: 42.496025, Lng: -83.358472), Route carried "on" structure: County highway 2059, Year Built: 1962, Year Reconstructed: 1988, Status: Open, Structure Length: 7.25m (23.79ft), Average Daily Traffic: 64,500 (year ), Truck Traffic: 3%, Average Future Daily Traffic: 64,500 , Design Load: HS 20, Features Intersected: I-696, Facility Carried by Structure: ORCHARD LAKE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 4.419, Lanes on structure: 7, Lanes under structure: 9, Base Highway Network: Yes (Inventory Route: 63, Subroute: 3), Owner: State Highway Agency, Approaching Roadway Width: 35.3m (115.8ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 24.7m (81.0ft), Curb-To-Curb Width: 36.5m (119.8ft), Out-to-Out Width: 37.5m (123.0ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Poor, Operating Rating: 97.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 54.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 15 months, Inspection Date: March 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Latex Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 63163101000S08, Location: 5.7 MI E OF I-96 (Lat: 42.492761, Lng: -83.338775), Route carried "on" structure: County highway 2059, Year Built: 1961, Year Reconstructed: 2002, Status: Open, Structure Length: 7.24m (23.75ft), Average Daily Traffic: 16,900 (year 2000), Truck Traffic: 9%, Average Future Daily Traffic: 22,200 (year 2025), Design Load: HS 20, Features Intersected: I-696, Facility Carried by Structure: MIDDLEBELT RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 5.689, Lanes on structure: 2, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 10.9m (35.8ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 23.9m (78.4ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.5m (4.9ft), Curb-To-Curb Width: 9.8m (32.2ft), Out-to-Out Width: 12.5m (41.0ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Inventory Rating: 53.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: March 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 63163191000S09, Location: S OF I-96/I-696 INTECHNG (Lat: 42.470883, Lng: -83.431156), Route carried "on" structure: City street 2059, Year Built: 1972, Status: Open, Structure Length: 12.83m (42.09ft), Average Daily Traffic: 21,500 (year 1994), Truck Traffic: 3%, Average Future Daily Traffic: 31,573 (year 2007), Design Load: HS 20, Features Intersected: I-275, I-96, Facility Carried by Structure: GRAND RIVER AVE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 22.014, Lanes on structure: 3, Lanes under structure: 10, Owner: State Highway Agency, Approaching Roadway Width: 18.2m (59.7ft), Skew: 1 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 40.8m (133.9ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 18.2m (59.7ft), Out-to-Out Width: 19.0m (62.3ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Inventory Rating: 47.3 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163191000S12, Location: 1 MI W OF FARMINGTON (Lat: 42.453575, Lng: -83.431519), Route carried "on" structure: Interstate 96, Year Built: 1971, Status: Open, Structure Length: 2.77m (9.09ft), Average Daily Traffic: 91,951 (year 2003), Truck Traffic: 8%, Average Future Daily Traffic: 93,330 (year 2018), Design Load: HS 20+Mod, Features Intersected: 9 MILE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 4.815, Lanes on structure: 4, Lanes under structure: 2, Base Highway Network: Yes (Inventory Route: 63, Subroute: 2), Owner: State Highway Agency, Approaching Roadway Width: 21.6m (70.9ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 27.7m (90.9ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 21.9m (71.9ft), Out-to-Out Width: 22.6m (74.1ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Inventory Rating: 51.8 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63163191000S13, Location: 1 MI W OF FARMINGTON (Lat: 42.453581, Lng: -83.431075), Route carried "on" structure: Interstate 96, Year Built: 1972, Status: Open, Structure Length: 2.77m (9.09ft), Average Daily Traffic: 91,951 (year 2003), Truck Traffic: 8%, Average Future Daily Traffic: 93,330 (year 2018), Design Load: HS 20+Mod, Features Intersected: 9 MI RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 4.974, Lanes on structure: 4, Lanes under structure: 2, Base Highway Network: Yes (Inventory Route: 63, Subroute: 7), Owner: State Highway Agency, Approaching Roadway Width: 21.6m (70.9ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 27.7m (90.9ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.0m, Curb-To-Curb Width: 21.9m (71.9ft), Out-to-Out Width: 22.6m (74.1ft) Condition: Deck: Fair, Superstructure: Good, Substructure: Good, Inventory Rating: 51.8 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63200184000B01, Location: BET GRAND RIVER AND 8 MIL (Lat: 42.446811, Lng: -83.336567), Route carried "on" structure: County highway 2059, Year Built: 1964, Status: Open, Structure Length: 1.07m (3.51ft), Average Daily Traffic: 20,809 (year 1991), Truck Traffic: 3%, Average Future Daily Traffic: 22,200 (year 2010), Design Load: HS 20+Mod, Features Intersected: ROUGE RIVER, Facility Carried by Structure: MIDDLEBELT RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.583, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 15.2m (49.9ft), Skew: 3 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 1, Length of Maximum Span: 9.4m (30.8ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 14.8m (48.6ft), Out-to-Out Width: 18.2m (59.7ft) Condition: Deck: Poor, Superstructure: Fair, Substructure: Satisfactory, Channel: Satisfactory, Inventory Rating: 60.9 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 1.52m (4.99ft), Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63200507000B01, Location: BET GRAND RIVER AND MIDDL (Lat: 42.441775, Lng: -83.328097), Route carried "on" structure: County highway 2059, Year Built: 1966, Status: Open, Structure Length: 0.94m (3.08ft), Average Daily Traffic: 20,809 (year 1991), Truck Traffic: 5%, Average Future Daily Traffic: 42,700 (year 2010), Design Load: HS 20+Mod, Features Intersected: ROUGE RIVER, Facility Carried by Structure: 8 MILE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 11.562, Lanes on structure: 5, Base Highway Network: Yes (Inventory Route: 441, Subroute: 1), Owner: County Highway Agency, Approaching Roadway Width: 18.2m (59.7ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 8.5m (27.9ft), Curb or Sidewalk Widths: Left: 2.2m (7.2ft), Right: 2.2m (7.2ft), Curb-To-Curb Width: 18.2m (59.7ft), Out-to-Out Width: 23.3m (76.4ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Satisfactory, Inventory Rating: 55.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 63200577000B01, Location: BET MIDDLEBELT AND INKSTE (Lat: 42.500092, Lng: -83.321397), Route carried "on" structure: County highway 2059, Year Built: 1987, Status: Open, Structure Length: 1.58m (5.18ft), Average Daily Traffic: 17,358 (year 1990), Average Future Daily Traffic: 20,800 (year 2017), Design Load: HS 20+Mod, Features Intersected: PEBBLE CREEK, Facility Carried by Structure: 12 MILE RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 16.037, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 9.1m (29.9ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 1, Length of Maximum Span: 15.2m (49.9ft), Curb or Sidewalk Widths: Left: 1.6m (5.2ft), Right: 0.0m, Curb-To-Curb Width: 13.4m (44.0ft), Out-to-Out Width: 22.8m (74.8ft) Condition: Deck: Very good, Superstructure: Good, Substructure: Good, Channel: Satisfactory, Inventory Rating: 9.1 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: High priority of corrective action, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 824180800092R01, Location: MT ELLIOTT - MOUND RD (Lat: 42.404319, Lng: -83.038067), Route carried "on" structure: City street 2000, Year Built: 1969, Year Reconstructed: 1996, Status: Open, Structure Length: 48.02m (157.55ft), Average Daily Traffic: 18,921 (year 2001), Truck Traffic: 5%, Average Future Daily Traffic: 35,058 (year 2021), Design Load: HS 20+Mod, Features Intersected: GTW RR AND CANIFF, Facility Carried by Structure: MT ELLIOTT - MOUND Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.682, Lanes on structure: 4, Lanes under structure: 4, Base Highway Network: Yes (Inventory Route: 470, Subroute: 16), Owner: City or Municipal Highway Agency, Approaching Roadway Width: 8.0m (26.2ft), Skew: 39 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 16, Length of Maximum Span: 37.8m (124.0ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.4m (4.6ft), Curb-To-Curb Width: 17.0m (55.8ft), Out-to-Out Width: 18.3m (60.0ft) Condition: Deck: Satisfactory, Superstructure: Poor, Substructure: Fair, Operating Rating: 78.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 47.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 48.02m (157.55ft), Designated Inspection Frequency: Every 12 months, Critical Feature Inspection Frequency: Every 12 months, Inspection Date: June 2007, Critical Feature Inspection Date: June 2007, Bridge Improvement Cost: $9,000, Total Project Cost: $10,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 63163022000S1, Location: 2MI W OF FARMINGTON (Lat: 42.468364, Lng: -83.417175), Route carried "under" structure: State highway 5, Year Built: 1957, Structure Length: 7.50m (24.61ft), Average Daily Traffic: 19,682 (year 2003), Truck Traffic: 3%, Features Intersected: M-5, Facility Carried by Structure: I-96 BL (GRAND RV) Minimum Vertical Clearance: 4.47m (14.67ft), Kilometerpoint: 22.211, Lanes on structure: 4, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 20.7m (67.9ft) Find on map >>
Structure Number: 63163022000S11, Location: 4.0 MI NW OF WAYNE CO LIN (Lat: 42.459144, Lng: -83.395675), Route carried "under" structure: State highway 5, Year Built: 1957, Structure Length: 4.17m (13.68ft), Average Daily Traffic: 19,682 (year 2003), Truck Traffic: 3%, Features Intersected: M-5, Facility Carried by Structure: DRAKE RD Minimum Vertical Clearance: 4.67m (15.32ft), Kilometerpoint: 24.435, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 21.0m (68.9ft) Find on map >>
Structure Number: 63163022000S14, Location: 0.2 MI E. OF FARMINGTON (Lat: 42.451275, Lng: -83.346236), Route carried "under" structure: Business Interstate 96, Year Built: 1957, Structure Length: 6.82m (22.38ft), Average Daily Traffic: 25,222 (year 1995), Truck Traffic: 3%, Features Intersected: GRAND RIVER EB CONN, Facility Carried by Structure: M-5 WB Minimum Vertical Clearance: 4.42m (14.50ft), Kilometerpoint: 0.327, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 23.7m (77.8ft) Find on map >>
Structure Number: 63163101000S02, Location: 0.5 MI NE OF I-96 (Lat: 42.483489, Lng: -83.435658), Route carried "under" structure: Interstate 696, Year Built: 1961, Structure Length: 8.84m (29.00ft), Average Daily Traffic: 60,656 (year 2003), Truck Traffic: 17%, Features Intersected: I-696, Facility Carried by Structure: HAGGERTY RD Minimum Vertical Clearance: 5.44m (17.85ft), Kilometerpoint: 0.797, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 21.6m (70.9ft) Find on map >>
Structure Number: 63163101000S03, Location: 1.7 MI NE OF I-96 (Lat: 42.491681, Lng: -83.416889), Route carried "under" structure: Interstate 696, Year Built: 1962, Structure Length: 8.07m (26.48ft), Average Daily Traffic: 170,558 (year 2003), Truck Traffic: 6%, Features Intersected: I-696, Facility Carried by Structure: HALSTEAD RD Minimum Vertical Clearance: 5.16m (16.93ft), Kilometerpoint: 2.578, Lanes on structure: 2, Lanes under structure: 8, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 22.8m (74.8ft) Find on map >>
Structure Number: 63163101000S04, Location: 2.7MI E OF I-96 OVER DRAK (Lat: 42.493972, Lng: -83.397467), Route carried "under" structure: City street , Year Built: 1960, Structure Length: 3.32m (10.89ft), Average Daily Traffic: 24,300 (year 1974), Features Intersected: DRAKE RD, Facility Carried by Structure: I-696 Minimum Vertical Clearance: 4.47m (14.67ft), Kilometerpoint: 4.672, Lanes on structure: 8, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 12.5m (41.0ft) Find on map >>
Structure Number: 63163101000S06, Location: 3.7 MI E OF I-96 (Lat: 42.495061, Lng: -83.378061), Route carried "under" structure: Interstate 696, Year Built: 1962, Structure Length: 7.86m (25.79ft), Average Daily Traffic: 170,558 (year 2003), Truck Traffic: 6%, Features Intersected: I-696, Facility Carried by Structure: FARMINGTON RD Minimum Vertical Clearance: 5.03m (16.50ft), Kilometerpoint: 5.807, Lanes on structure: 2, Lanes under structure: 8, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 18.3m (60.0ft) Find on map >>
Structure Number: 63163101000S07, Location: 4.7 MI E OF I-96 (Lat: 42.496025, Lng: -83.358472), Route carried "under" structure: Interstate 696, Year Built: 1962, Structure Length: 7.25m (23.79ft), Average Daily Traffic: 180,044 (year 2003), Truck Traffic: 6%, Features Intersected: I-696, Facility Carried by Structure: ORCHARD LAKE RD Minimum Vertical Clearance: 5.26m (17.26ft), Kilometerpoint: 7.419, Lanes on structure: 7, Lanes under structure: 9, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 24.7m (81.0ft) Find on map >>
Structure Number: 63163101000S08, Location: 5.7 MI E OF I-96 (Lat: 42.492761, Lng: -83.338775), Route carried "under" structure: Interstate 696, Year Built: 1961, Structure Length: 7.24m (23.75ft), Average Daily Traffic: 180,044 (year 2003), Truck Traffic: 6%, Features Intersected: I-696, Facility Carried by Structure: MIDDLEBELT RD Minimum Vertical Clearance: 5.16m (16.93ft), Kilometerpoint: 9.114, Lanes on structure: 2, Lanes under structure: 8, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 23.9m (78.4ft) Find on map >>
Structure Number: 63163191000S09, Location: S OF I-96/I-696 INTECHNG (Lat: 42.470883, Lng: -83.431156), Route carried "under" structure: Interstate 96, Year Built: 1972, Structure Length: 12.83m (42.09ft), Average Daily Traffic: 183,902 (year 2003), Truck Traffic: 8%, Features Intersected: I-275, I-96, Facility Carried by Structure: GRAND RIVER AVE Minimum Vertical Clearance: 5.33m (17.49ft), Kilometerpoint: 2.876, Lanes on structure: 3, Lanes under structure: 10, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 40.8m (133.9ft) Find on map >>
Structure Number: 63163191000S12, Location: 1 MI W OF FARMINGTON (Lat: 42.453575, Lng: -83.431519), Route carried "under" structure: City street , Year Built: 1971, Structure Length: 2.77m (9.09ft), Average Daily Traffic: 12,600 (year 1994), Truck Traffic: 3%, Features Intersected: 9 MILE RD, Facility Carried by Structure: I-96 EB Minimum Vertical Clearance: 4.37m (14.34ft), Kilometerpoint: 4.884, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.7m (90.9ft) Find on map >>
Structure Number: 63163191000S13, Location: 1 MI W OF FARMINGTON (Lat: 42.453581, Lng: -83.431075), Route carried "under" structure: City street , Year Built: 1972, Structure Length: 2.77m (9.09ft), Average Daily Traffic: 12,600 (year 1994), Truck Traffic: 3%, Features Intersected: 9 MI RD, Facility Carried by Structure: I-96 WB Minimum Vertical Clearance: 4.52m (14.83ft), Kilometerpoint: 4.849, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.7m (90.9ft) Find on map >>
Structure Number: 824180800092R01, Location: MT ELLIOTT - MOUND RD (Lat: 42.404319, Lng: -83.038067), Route carried "under" structure: City street 2000, Year Built: 1969, Structure Length: 48.02m (157.55ft), Average Daily Traffic: 5,795 (year 1980), Features Intersected: GTW RR AND CANIFF, Facility Carried by Structure: MT ELLIOTT - MOUND Minimum Vertical Clearance: 4.24m (13.91ft), Kilometerpoint: 3.413, Lanes on structure: 4, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 37.8m (124.0ft) Discuss this city on our hugely popular Michigan forum Back to: Farmington Hills, MI, Michigan, All US cities.
|
![]() |