Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Farmington, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 108ft / 33.2mTotal length
  • 257,247Total average daily traffic
  • 11,059Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Farmington
  • No street view available for this location

New bridges in Farmington, MI - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 51950-1959
  • 61970-1979
  • 11980-1989
  • 12000-2009
Reconstructed bridges in Farmington, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 21990-1999
Average Bridge Daily Traffic in Farmington, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.0%Good
  • 60.0%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 60.0%Good
  • 40.0%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 40.0%Good
  • 60.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Good
  • 66.7%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Good
  • 33.3%Satisfactory
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 7786,  Location: IN FARMINGTON (E GRAND RI (Lat: 42.459142,  Lng: -83.362981),  Route carried "on" structure: Business Interstate 96,  Year Built: 2006,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 16,002 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 22,759 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: ROUGE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 28.045,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 410,  Subroute: 42),  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7807,  Location: IN FARMINGTON (Lat: 42.456000,  Lng: -83.375967),  Route carried "on" structure: State highway 5,  Year Built: 1956,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 16,814 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,365 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: FARMINGTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.093,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 65,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7808,  Location: IN FARMINGTON (Lat: 42.456225,  Lng: -83.375972),  Route carried "on" structure: State highway 5,  Year Built: 1956,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 16,814 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,365 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: FARMINGTON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.129,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 65,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8123,  Location: @ I-96/I-696 INTERCHANGE (Lat: 42.478114,  Lng: -83.427336),  Route carried "on" structure: Ramp Interstate 96,  Year Built: 1971,  Status: Open,  Structure Length: 8.34m (27.36ft),  Average Daily Traffic: 8,280 (year 1982),  Truck Traffic: 13%,  Average Future Daily Traffic: 9,522 (year 2002),  Design Load: HS 20+Mod,  Features Intersected: M-5
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.577,  Lanes on structure: 3,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8128,  Location: AT I-696 (Lat: 42.479986,  Lng: -83.426431),  Route carried "on" structure: Ramp Interstate 96,  Year Built: 1972,  Status: Open,  Structure Length: 5.91m (19.39ft),  Average Daily Traffic: 13,103 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,980 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RAMP FROM M-102
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.539,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 92.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8129,  Location: I-96/I-696 INTERCHANGE (Lat: 42.478297,  Lng: -83.427883),  Route carried "on" structure: Interstate 96,  Year Built: 1972,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 76,500 (year 1995),  Truck Traffic: 7%,  Average Future Daily Traffic: 81,786 (year 2015),  Design Load: HS 20,  Features Intersected: M-5
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.204,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 441,  Subroute: 20),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.0m (108.3ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 8236,  Location: 50FT W OF FARMINGTON ROAD (Lat: 42.466142,  Lng: -83.371781),  Route carried "on" structure: City street ,  Year Built: 1981,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 4,290 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,500 (year 2028),  Features Intersected: BRANCH UPPER ROUGE RIVER,  Facility Carried by Structure: SHIAWASSEE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.033,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 8237,  Location: 0.1 MI N OF GRAND RIVER (Lat: 42.461733,  Lng: -83.366561),  Route carried "on" structure: City street ,  Year Built: 1940,  Year Reconstructed: 1957,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 2,580 (year 2008),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,700 (year 2028),  Features Intersected: UPPER ROUGE RIVER,  Facility Carried by Structure: POWER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.708,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7791,  Location: IN FARMINGTON (Lat: 42.454564,  Lng: -83.365894),  Route carried "under" structure: State highway 5,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 33,628 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-5,  Facility Carried by Structure: POWERS RD WALKOVER
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 26.937,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 7807,  Location: IN FARMINGTON (Lat: 42.456000,  Lng: -83.375967),  Route carried "under" structure: County highway 2059,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 1974),  Features Intersected: FARMINGTON RD,  Facility Carried by Structure: M-5 EB
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 1.716,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 7808,  Location: IN FARMINGTON (Lat: 42.456225,  Lng: -83.375972),  Route carried "under" structure: County highway 2059,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 1974),  Features Intersected: FARMINGTON RD,  Facility Carried by Structure: M-5 WB
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 1.741,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 8123,  Location: @ I-96/I-696 INTERCHANGE (Lat: 42.478114,  Lng: -83.427336),  Route carried "under" structure: State highway 5,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 32,868 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-5,  Facility Carried by Structure: I-96 RAMP
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 20.834,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 8128,  Location: AT I-696 (Lat: 42.479986,  Lng: -83.426431),  Route carried "under" structure: Ramp State highway 102,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 2,500 (year 0000),  Features Intersected: RAMP FROM M-102,  Facility Carried by Structure: I-96 RAMP
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 1.827,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 8129,  Location: I-96/I-696 INTERCHANGE (Lat: 42.478297,  Lng: -83.427883),  Route carried "under" structure: State highway 5,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 32,868 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-5,  Facility Carried by Structure: I-96
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 20.790,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.0m (108.3ft)

Discuss Farmington, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.