Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Flatonia, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 57m187ftTotal length
  • 95,450Total average daily traffic
  • 34,489Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Flatonia
  • No street view available for this location

New bridges - Historical Statistics

  • 11940-1949
  • 91960-1969

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Channel

Find on map >>   Show street view

Structure Number: 130760053506098,  Location: 0.4 MI W OF FM 609 (Lat: 29.696719,  Lng: -97.108581),  Route carried "on" structure: State highway 95,  Year Built: 1969,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 2,700 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,640 (year 2032),  Design Load: H 20,  Features Intersected: IH 10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.239,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 13,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 130760053506099,  Location: 0.18 MI E OF SH 95 (Lat: 29.697461,  Lng: -97.105617),  Route carried "on" structure: Interstate 10,  Year Built: 1969,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 9,360 (year 2008),  Truck Traffic: 38%,  Average Future Daily Traffic: 16,310 (year 2032),  Design Load: HS 20,  Features Intersected: Big Fivemile Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.719,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.2m (56.4ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 13,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1307600535061,  Location: 0.18 MI E OF SH 95 (Lat: 29.695994,  Lng: -97.105672),  Route carried "on" structure: Interstate 10,  Year Built: 1969,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 9,360 (year 2008),  Truck Traffic: 38%,  Average Future Daily Traffic: 16,310 (year 2032),  Design Load: HS 20,  Features Intersected: Big Fivemile Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.264,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 13,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 130760053506101,  Location: 0.4 MI E OF FM 95 (Lat: 29.696961,  Lng: -97.102478),  Route carried "on" structure: Interstate 10,  Year Built: 1969,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 10,550 (year 2011),  Truck Traffic: 39%,  Average Future Daily Traffic: 15,490 (year 2032),  Design Load: HS 20,  Features Intersected: FM 609
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.028,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 13,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 130760053506102,  Location: 0.4 MI E OF FM 95 (Lat: 29.696781,  Lng: -97.102478),  Route carried "on" structure: Interstate 10,  Year Built: 1969,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 10,550 (year 2011),  Truck Traffic: 39%,  Average Future Daily Traffic: 15,490 (year 2032),  Design Load: HS 20,  Features Intersected: FM 609
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.007,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 13,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 130760002602047,  Location: 0.30 MI E OF FM 2762 (Lat: 29.688028,  Lng: -97.114786),  Route carried "under" structure: US 90,  Year Built: 1942,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 1,650 (year 2011),  Truck Traffic: 19%,  Features Intersected: US 90,  Facility Carried by Structure: UNION PACIFIC RR
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 6.323,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.4m (44.0ft)

Find on map >>   Show street view

Structure Number: 130760053506097,  Location: 0.20 MI W OF SH 95 (Lat: 29.696622,  Lng: -97.111872),  Route carried "under" structure: Interstate 10,  Year Built: 1969,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 23,340 (year 2011),  Truck Traffic: 38%,  Features Intersected: IH 10,  Facility Carried by Structure: UNION PACIFIC RR
Minimum Vertical Clearance: 0.52m (1.71ft),  Kilometerpoint: 8.098,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 130760053506098,  Location: 0.4 MI W OF FM 609 (Lat: 29.696719,  Lng: -97.108581),  Route carried "under" structure: Interstate 10,  Year Built: 1969,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 23,340 (year 2011),  Truck Traffic: 38%,  Features Intersected: IH 10,  Facility Carried by Structure: SH 95
Minimum Vertical Clearance: 0.51m (1.67ft),  Kilometerpoint: 8.425,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.4m (80.1ft)

Find on map >>   Show street view

Structure Number: 130760053506101,  Location: 0.4 MI E OF FM 95 (Lat: 29.696961,  Lng: -97.102478),  Route carried "under" structure: State highway 609,  Year Built: 1969,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 2,300 (year 2011),  Truck Traffic: 18%,  Features Intersected: FM 609,  Facility Carried by Structure: IH 10 WB
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 31.324,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 130760053506102,  Location: 0.4 MI E OF FM 95 (Lat: 29.696781,  Lng: -97.102478),  Route carried "under" structure: State highway 609,  Year Built: 1969,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 2,300 (year 2011),  Truck Traffic: 18%,  Features Intersected: FM 609,  Facility Carried by Structure: IH 10 EB
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 31.364,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)