National Bridge Inventory (NBI) Statistics
Number of bridges: 21
Total length: 175 meters (574ft)
Total costs: $650,000
Total average daily traffic: 1,134,812
Total average daily truck traffic: 86,764
National Bridge Inventory (NBI) Registered Bridges for Garfield Heights

New bridges - Historical Statistics

  • 1920-1929: 4
  • 1930-1939: 0
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 0
  • 1970-1979: 16
  • 1980-1989: 0
  • 1990-1999: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 180174,  Location: APPROX 7500FT S E93RD ST. (Lat: 41.438181,  Lng: -81.613319),  Route carried "on" structure: State highway 14,  Year Built: 1928,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 15,950 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 22,139 (year 2027),  Design Load: H 15,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.980,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $324,000,  Roadway Improvement Cost: $36,000,  Total Project Cost: $360,000 ( Estimate for 2000),  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 1801775,  Location: APPROX 1.1 MI S MILES RD. (Lat: 41.433692,  Lng: -81.606047),  Route carried "on" structure: State highway 14,  Year Built: 1928,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 15,950 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 22,139 (year 2027),  Design Load: H 15,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.790,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.44m (8.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $261,000,  Roadway Improvement Cost: $29,000,  Total Project Cost: $290,000 ( Estimate for 2000),  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 1801805,  Location: APPROX 2MI W CNTY144 (Lat: 41.432006,  Lng: -81.602358),  Route carried "on" structure: State highway 14,  Year Built: 1929,  Status: Open,  Structure Length: 41.42m (135.89ft),  Average Daily Traffic: 15,950 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 22,139 (year 2027),  Design Load: H 15,  Features Intersected: NSC,W&LE RR @ HENRY ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.160,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 9,  Number Of Approach Spans: 47,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Membrane: Epoxy
Find on map >>

Structure Number: 1812122,  Location: .09 MI. E. OF JCT. SR-14 (Lat: 41.424192,  Lng: -81.580117),  Route carried "on" structure: Ramp Interstate 480,  Year Built: 1976,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 5,950 (year 2000),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,259 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: 14-480W RMP OVER MCCRAKE,  Facility Carried by Structure: RAMP W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.820,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 181213,  Location: .11 MI. E. OF JCT. SR-14 (Lat: 41.424281,  Lng: -81.579722),  Route carried "on" structure: Ramp Interstate 480,  Year Built: 1976,  Status: Open,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 158,025 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 219,339 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: 480&14RMP OVER MCCRAKEN,  Facility Carried by Structure: BEDFORD FREEWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.860,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 22.7m (74.5ft),  Out-to-Out Width: 23.9m (78.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 1812149,  Location: .16 MI. E. OF JCT. SR-14 (Lat: 41.424469,  Lng: -81.578756),  Route carried "on" structure: Ramp Interstate 480,  Year Built: 1976,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 7,490 (year 2001),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,396 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: 480W-14 RMP OVER MCCRAKE,  Facility Carried by Structure: RAMP E-N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.940,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 1812556,  Location: 2.0 MI. W. OF JCT. SR-14 (Lat: 41.411614,  Lng: -81.615772),  Route carried "on" structure: City street E98ST,  Year Built: 1977,  Status: Open,  Structure Length: 12.44m (40.81ft),  Average Daily Traffic: 27,882 (year 2002),  Truck Traffic: 5%,  Average Future Daily Traffic: 227,200 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: IR480,  Facility Carried by Structure: E. 98TH ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.300,  Lanes on structure: 4,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Epoxy
Find on map >>

Structure Number: 1812564,  Location: 1.35 MI. W. OF JCT. SR-14 (Lat: 41.413694,  Lng: -81.603739),  Route carried "on" structure: County highway 72,  Year Built: 1977,  Status: Open,  Structure Length: 11.03m (36.19ft),  Average Daily Traffic: 34,589 (year 2002),  Truck Traffic: 4%,  Average Future Daily Traffic: 227,200 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: IR480,  Facility Carried by Structure: TURNEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 77.300,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 1812572,  Location: .79 MI. W. OF JCT. SR-14 (Lat: 41.417108,  Lng: -81.594214),  Route carried "on" structure: Interstate 480,  Year Built: 1977,  Status: Open,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 81,844 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 113,599 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR-17 (1697) GRANGER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.410,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 28.3m (92.8ft),  Out-to-Out Width: 29.3m (96.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 181258,  Location: .79 MI. W. OF JCT. SR-14 (Lat: 41.417108,  Lng: -81.594214),  Route carried "on" structure: Interstate 480,  Year Built: 1977,  Status: Open,  Structure Length: 8.38m (27.49ft),  Average Daily Traffic: 81,844 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 113,599 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: SR-17 (1704) GRANGER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.410,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 21.7m (71.2ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 181339,  Location: JCT. SR-14 AND I-480 (Lat: 41.424414,  Lng: -81.579131),  Route carried "on" structure: Ramp Interstate 480,  Year Built: 1976,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 158,025 (year 2004),  Truck Traffic: 8%,  Average Future Daily Traffic: 42,317 (year 2024),  Design Load: HS 20+Mod,  Features Intersected: IR-480,  Facility Carried by Structure: SR-14 AND RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.900,  Lanes on structure: 3,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 23.8m (78.1ft),  Skew: 11 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 22.7m (74.5ft),  Out-to-Out Width: 23.9m (78.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Membrane: Built-up
Find on map >>

Structure Number: 1831925,  Location: 636 FT W OF BROADWAY RD (Lat: 41.425000,  Lng: -81.683333),  Route carried "on" structure: County highway 55,  Year Built: 1995,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 8,232 (year 2000),  Truck Traffic: 17%,  Average Future Daily Traffic: 5,682 (year 2023),  Design Load: HS 20,  Features Intersected: MILL CRK/MCCRACKEN #126
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1834282,  Location: AT BROADWAY ROAD (Lat: 41.430000,  Lng: -81.600000),  Route carried "on" structure: County highway 240,  Year Built: 1929,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 5,904 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,853 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: MILL CRK/HENRY ST #89
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 40.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1812122,  Location: .09 MI. E. OF JCT. SR-14 (Lat: 41.424192,  Lng: -81.580117),  Route carried "under" structure: County highway 55,  Year Built: 1976,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 100 (year 1975),  Features Intersected: I-480 RAMP (LANE B-OBS),  Facility Carried by Structure: RAMP W.
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.246,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>

Structure Number: 181213,  Location: .11 MI. E. OF JCT. SR-14 (Lat: 41.424281,  Lng: -81.579722),  Route carried "under" structure: County highway 55,  Year Built: 1976,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 100 (year 1975),  Features Intersected: I-480 RAMP,  Facility Carried by Structure: BEDFORD FREEWAY
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.246,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>

Structure Number: 1812149,  Location: .16 MI. E. OF JCT. SR-14 (Lat: 41.424469,  Lng: -81.578756),  Route carried "under" structure: County highway 55,  Year Built: 1976,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 100 (year 1975),  Features Intersected: I-480 RAMP (LANE OBS-EB),  Facility Carried by Structure: RAMP E-N
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 0.246,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>

Structure Number: 1812556,  Location: 2.0 MI. W. OF JCT. SR-14 (Lat: 41.411614,  Lng: -81.615772),  Route carried "under" structure: Interstate 480,  Year Built: 1977,  Structure Length: 12.44m (40.81ft),  Average Daily Traffic: 163,689 (year 2004),  Truck Traffic: 8%,  Features Intersected: E 98TH ST,  Facility Carried by Structure: E. 98TH ST.
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 3.148,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>

Structure Number: 1812564,  Location: 1.35 MI. W. OF JCT. SR-14 (Lat: 41.413694,  Lng: -81.603739),  Route carried "under" structure: Interstate 480,  Year Built: 1977,  Structure Length: 11.03m (36.19ft),  Average Daily Traffic: 163,689 (year 2004),  Truck Traffic: 8%,  Features Intersected: CR-72 (TURNEY RD),  Facility Carried by Structure: TURNEY RD
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 3.251,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>

Structure Number: 1812572,  Location: .79 MI. W. OF JCT. SR-14 (Lat: 41.417108,  Lng: -81.594214),  Route carried "under" structure: State highway 17,  Year Built: 1977,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 15,737 (year 2004),  Truck Traffic: 3%,  Features Intersected: I-480 (CUY-480-2075L),  Facility Carried by Structure: I-480 W.B.
Minimum Vertical Clearance: 0.45m (1.48ft),  Kilometerpoint: 2.732,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>

Structure Number: 181258,  Location: .79 MI. W. OF JCT. SR-14 (Lat: 41.417108,  Lng: -81.594214),  Route carried "under" structure: State highway 17,  Year Built: 1977,  Structure Length: 8.38m (27.49ft),  Average Daily Traffic: 15,737 (year 2004),  Truck Traffic: 3%,  Features Intersected: I-480 (CUY-480-2075R),  Facility Carried by Structure: I-480 E.B.
Minimum Vertical Clearance: 0.61m (2.00ft),  Kilometerpoint: 2.743,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>

Structure Number: 181339,  Location: JCT. SR-14 AND I-480 (Lat: 41.424414,  Lng: -81.579131),  Route carried "under" structure: Interstate 480,  Year Built: 1976,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 158,025 (year 2004),  Truck Traffic: 8%,  Features Intersected: BROADWAY AVE (SR14) RAMP,  Facility Carried by Structure: SR-14 AND RAMPS
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 0.349,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.6m (120.1ft)