![]() |
Bridge Statistics for Hilliard, Ohio (OH) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Hilliard, OH, Ohio, Ohio forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 21 Total length: 85 meters (279ft) Total average daily traffic: 582,269 Total average daily truck traffic: 49,635 National Bridge Inventory (NBI) Registered Bridges for Hilliard
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Bridge Condition - Culverts Find on map >>
Structure Number: 2509962, Location: 3.94 MI N OF I-70 (Lat: 40.033333, Lng: -83.123333), Route carried "on" structure: County highway 30, Year Built: 1968, Status: Open, Structure Length: 9.91m (32.51ft), Average Daily Traffic: 45,300 (year 1995), Average Future Daily Traffic: 163,684 (year 2027), Design Load: HS 20+Mod, Features Intersected: IR 270, Facility Carried by Structure: CEMETERY RD. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 11.6m (38.1ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 29.9m (98.1ft), Curb-To-Curb Width: 8.5m (27.9ft), Out-to-Out Width: 10.4m (34.1ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 2509997, Location: 3.95 MI N OF I-70 (Lat: 40.033333, Lng: -83.123333), Route carried "on" structure: County highway 30, Year Built: 1968, Year Reconstructed: 1996, Status: Open, Structure Length: 10.18m (33.40ft), Average Daily Traffic: 43,100 (year 1995), Average Future Daily Traffic: 163,684 (year 2027), Design Load: HS 20+Mod, Features Intersected: IR 270, Facility Carried by Structure: CEMETARY RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 15.2m (49.9ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 30.8m (101.0ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 14.0m (45.9ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete Find on map >>
Structure Number: 2510057, Location: 5.16 MI N OF I-70 (Lat: 40.050000, Lng: -83.128333), Route carried "on" structure: County highway 31, Year Built: 1968, Status: Open, Structure Length: 8.60m (28.22ft), Average Daily Traffic: 10,400 (year 2000), Average Future Daily Traffic: 153,083 (year 2027), Design Load: H 20, Features Intersected: IR-270/UNDER CR-31(DAVDS Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 25.0m (82.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 9.1m (29.9ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 2531313, Location: JUST N. OF HAYDEN RUN RD. (Lat: 40.055361, Lng: -83.159944), Route carried "on" structure: City street C0003, Year Built: 2005, Status: Open, Structure Length: 1.16m (3.81ft), Average Daily Traffic: 11,500 (year 2003), Truck Traffic: 2%, Average Future Daily Traffic: 20,300 (year 2025), Design Load: HS 25, Features Intersected: HAYDEN RUN(AVERY ROAD), Facility Carried by Structure: AVERY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: County Highway Agency, Approaching Roadway Width: 20.7m (67.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 11.0m (36.1ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: May 2007 Find on map >>
Structure Number: 2533278, Location: 0.1 MI N.OF HAYDEN RUN RD (Lat: 40.060000, Lng: -83.147778), Route carried "on" structure: County highway C0040, Year Built: 1925, Year Reconstructed: 1981, Status: Open, Structure Length: 0.82m (2.69ft), Average Daily Traffic: 1,075 (year 1997), Truck Traffic: 5%, Average Future Daily Traffic: 1,492 (year 2024), Design Load: HS 20+Mod, Features Intersected: HAYDEN RUN (WILCOX RD), Facility Carried by Structure: WILCOX RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 11.0m (36.1ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.6m (24.9ft), Curb-To-Curb Width: 11.1m (36.4ft), Out-to-Out Width: 11.1m (36.4ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Satisfactory, Channel: Good, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: May 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >>
Structure Number: 2535521, Location: 1 MI WEST OF DUBLIN RD (Lat: 39.958333, Lng: -83.201667), Route carried "on" structure: County highway C0029, Year Built: 1970, Status: Open, Structure Length: 5.43m (17.81ft), Average Daily Traffic: 3,660 (year 1997), Truck Traffic: 5%, Average Future Daily Traffic: 5,080 (year 2030), Design Load: HS 20, Features Intersected: CSX RR (SCIOTO DARBY), Facility Carried by Structure: SCIOTO DARBY CR RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 13.4m (44.0ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 20.4m (66.9ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 9.1m (29.9ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Poor, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: January 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2535955, Location: 0.1 MI SOUTH OF DAVIDSON (Lat: 40.053444, Lng: -83.106556), Route carried "on" structure: City street C0010, Year Built: 1999, Status: Open, Structure Length: 0.76m (2.49ft), Average Daily Traffic: 14,820 (year 1999), Truck Traffic: 2%, Average Future Daily Traffic: 20,570 (year 2026), Design Load: HS 20+Mod, Features Intersected: SMITH DITCH (DUBLIN), Facility Carried by Structure: DUBLIN RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 3, Owner: County Highway Agency, Approaching Roadway Width: 13.4m (44.0ft), Skew: 3 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.0m (23.0ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: May 2007 Structure Number: 2565307, Location: N/CEMETERY ROAD, Route carried "on" structure: City street TRUEM, Year Built: 2004, Status: Open, Structure Length: 1.16m (3.81ft), Average Daily Traffic: 18,850 (year 2004), Average Future Daily Traffic: 25,390 (year 2027), Design Load: HS 25, Features Intersected: VD O/TUDOR DITCH
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 5, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 11.0m (36.1ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2565366, Location: 0.15 MI N/CEMETERY ROAD (Lat: 40.035833, Lng: -83.119167), Route carried "on" structure: City street TRUEM, Year Built: 2004, Status: Open, Structure Length: 1.86m (6.10ft), Average Daily Traffic: 18,850 (year 2004), Average Future Daily Traffic: 25,390 (year 2027), Design Load: HS 25, Features Intersected: YD O/MOLCOMB DITCH, Facility Carried by Structure: CEMETERY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Skew: 4 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 18.0m (59.1ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: November 2007 Find on map >>
Structure Number: 2565412, Location: 0.25 MI N/TRUEMAN COURT (Lat: 40.040556, Lng: -83.123889), Route carried "on" structure: City street TRUEM, Year Built: 2004, Status: Open, Structure Length: 0.67m (2.20ft), Average Daily Traffic: 18,850 (year 2004), Average Future Daily Traffic: 25,390 (year 2027), Design Load: HS 25, Features Intersected: VD O/HOLCOMB DITCH Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 6.1m (20.0ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: November 2007 Structure Number: 2565749, Location: 1.0 MI S/TUTTLE ROAD, Route carried "on" structure: City street BRIT, Year Built: 2006, Status: Open, Structure Length: 3.14m (10.30ft), Average Daily Traffic: 13,500 (year 2006), Truck Traffic: 5%, Average Future Daily Traffic: 34,900 (year 2029), Design Load: HS 25, Features Intersected: BIKEWAY HAYDEN RUN
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 30.8m (101.0ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 2.0m (6.6ft), Curb-To-Curb Width: 8.1m (26.6ft), Out-to-Out Width: 10.9m (35.8ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Excellent, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Structure Number: 2565757, Location: 1.0 MI S/TUTTLE ROAD, Route carried "on" structure: City street BRIT, Year Built: 2006, Status: Open, Structure Length: 3.14m (10.30ft), Average Daily Traffic: 25,000 (year 2006), Truck Traffic: 5%, Average Future Daily Traffic: 34,900 (year 2029), Design Load: HS 25, Features Intersected: BIKEWAY HAYDEN RUN
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 30.8m (101.0ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 3.0m (9.8ft), Curb-To-Curb Width: 8.1m (26.6ft), Out-to-Out Width: 12.4m (40.7ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Excellent, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Structure Number: 2566095, Location: E OF DUBLIN ROAD, Route carried "on" structure: City street MELBU, Year Built: 1990, Status: Open, Structure Length: 1.04m (3.41ft), Average Daily Traffic: 1,000 (year 2007), Average Future Daily Traffic: 1,347 (year 2027), Features Intersected: O HOLCOMB DITCH E/DUBLIN
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Skew: 1 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 9.8m (32.2ft) Condition: Channel: Very good, Culverts: Very good, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007 Structure Number: 2566141, Location: EAST OF DUBLIN ROAD, Route carried "on" structure: City street SCIOT, Year Built: 1992, Status: Open, Structure Length: 1.04m (3.41ft), Average Daily Traffic: 1,000 (year 2008), Average Future Daily Traffic: 1,347 (year 2027), Design Load: HS 20+Mod, Features Intersected: ATES COURT O HOLCOMB DIT
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 9.8m (32.2ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 32.4 metric tons, Inventory Rating: 23.4 metric tons, Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007 Structure Number: 256637, Location: E OF BRITTON PARKWAY, Route carried "on" structure: City street RIGGI, Year Built: 2006, Status: Open, Structure Length: 1.10m (3.61ft), Average Daily Traffic: 1,000 (year 2008), Average Future Daily Traffic: 1,347 (year 2027), Design Load: HS 25, Features Intersected: O BROWN DITCH E/BRITTON
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 3, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 11.9m (39.0ft), Skew: 2 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 10.4m (34.1ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007 Structure Number: 2566583, Location: N/HAYDEN RUN ROAD, Route carried "on" structure: City street BRITT, Year Built: 2006, Status: Open, Structure Length: 1.04m (3.41ft), Average Daily Traffic: 1,000 (year 2008), Average Future Daily Traffic: 1,000 (year 2027), Design Load: HS 25, Features Intersected: WY O BROWN DITCH N/HAYDE
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 9.8m (32.2ft) Condition: Channel: Very good, Culverts: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: December 2007 Find on map >>
Structure Number: 2509962, Location: 3.94 MI N OF I-70 (Lat: 40.033333, Lng: -83.123333), Route carried "under" structure: Interstate 270, Year Built: 1968, Structure Length: 9.91m (32.51ft), Average Daily Traffic: 116,307 (year 2006), Truck Traffic: 14%, Features Intersected: UNDER CEMETERY RD EB, Facility Carried by Structure: CEMETERY RD. Minimum Vertical Clearance: 0.50m (1.64ft), Kilometerpoint: 2.033, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 29.9m (98.1ft) Find on map >>
Structure Number: 2509997, Location: 3.95 MI N OF I-70 (Lat: 40.033333, Lng: -83.123333), Route carried "under" structure: Interstate 270, Year Built: 1968, Structure Length: 10.18m (33.40ft), Average Daily Traffic: 116,307 (year 2006), Truck Traffic: 14%, Features Intersected: UNDER CEMETERY RD WB, Facility Carried by Structure: CEMETARY RD Minimum Vertical Clearance: 0.49m (1.61ft), Kilometerpoint: 2.035, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.8m (101.0ft) Find on map >>
Structure Number: 2510057, Location: 5.16 MI N OF I-70 (Lat: 40.050000, Lng: -83.128333), Route carried "under" structure: Interstate 270, Year Built: 1968, Structure Length: 8.60m (28.22ft), Average Daily Traffic: 110,650 (year 2006), Truck Traffic: 13%, Features Intersected: UNDER CR 31 DAVIDSON ROA, Facility Carried by Structure: CR 31 DAVIDSON RD Minimum Vertical Clearance: 4.88m (16.01ft), Kilometerpoint: 2.225, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.0m (82.0ft) Structure Number: 2565811, Location: WEST OF NORWICH STREET, Route carried "under" structure: City street CEMET, Year Built: 1976, Structure Length: 3.08m (10.10ft), Average Daily Traffic: 10,000 (year 1980), Features Intersected: RD U/RR W/NORWICH ST, Facility Carried by Structure: RAILROAD
Minimum Vertical Clearance: 0.45m (1.48ft), Kilometerpoint: 0.000, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Girder and Floorbeam System, Length of Maximum Span: 28.3m (92.8ft) Structure Number: 256587, Location: W/BRITTON PARKWAY, Route carried "under" structure: City street CEMET, Year Built: 1987, Structure Length: 2.71m (8.89ft), Average Daily Traffic: 100 (year 2008), Features Intersected: RD U/RR W/BRITTON PRKY, Facility Carried by Structure: RAILROAD
Minimum Vertical Clearance: 4.65m (15.26ft), Kilometerpoint: 0.000, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Girder and Floorbeam System, Length of Maximum Span: 25.9m (85.0ft) Discuss this city on our hugely popular Ohio forum Back to: Hilliard, OH, Ohio, All US cities.
|
![]() |