U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Hollywood, Florida (FL) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Hollywood, FL, Florida, Florida forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 37
Total length: 281 meters (922ft)
Total average daily traffic: 2,691,529
Total average daily truck traffic: 156,815
National Bridge Inventory (NBI) Registered Bridges for Hollywood
No street view available for this location

New bridges - Historical Statistics

  • 1950-1959: 2
  • 1960-1969: 17
  • 1970-1979: 6
  • 1980-1989: 4
  • 1990-1999: 8

Reconstructed bridges - Historical Statistics

  • 1980-1989: 1
  • 1990-1999: 6
  • 2000-2009: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>   Show street view

Structure Number: 860043,  Location: Sheridan St & SR-A1A (Lat: 26.034158,  Lng: -80.117908),  Route carried "on" structure: State highway 822,  Year Built: 1962,  Status: Open,  Structure Length: 10.80m (35.43ft),  Average Daily Traffic: 16,100 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 27,934 (year 2033),  Design Load: H 20,  Features Intersected: Intracoastal Waterway
Minimum Vertical Clearance: 5.85m (19.19ft),  Kilometerpoint: 9.073,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 6.7m (22.0ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 34.1m (111.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.6m (57.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: August 11,  Critical Feature Inspection Date: August 11,  Underwater Inspection Date: August 11,  Other Special Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860045,  Location: 0.2 MI E OF I-95 ON SR822 (Lat: 26.033181,  Lng: -80.161811),  Route carried "on" structure: State highway 822,  Year Built: 1965,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 42,500 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 73,738 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: Canal C-10
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.677,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 30.4m (99.7ft),  Skew: 21 degrees,  Navigation Control: Yes ( Vertical Clearance: 2.0m (6.6ft), Horizontal Clearance: 7.6m (24.9ft)),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.7m (28.5ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 30.4m (99.7ft),  Out-to-Out Width: 37.9m (124.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: November 11,  Underwater Inspection Date: September 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860102,  Location: 1mi. S of Sheridan St. (Lat: 26.018617,  Lng: -80.167528),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: Johnson Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.937,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 28.9m (94.8ft),  Out-to-Out Width: 29.8m (97.8ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 860104,  Location: .5 miles South of SR-822 (Lat: 26.025989,  Lng: -80.166958),  Route carried "on" structure: Interstate 95,  Year Built: 1964,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 273,000 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 473,655 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: Taft Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.755,  Lanes on structure: 12,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 58.0m (190.3ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.3m (66.6ft),  Curb-To-Curb Width: 58.0m (190.3ft),  Out-to-Out Width: 59.5m (195.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 10,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860145,  Location: 2.1 MI N OF SR-820 (Lat: 26.039358,  Lng: -80.213975),  Route carried "on" structure: State highway 1,  Year Built: 1956,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 110,600 (year 2011),  Truck Traffic: 7%,  Average Future Daily Traffic: 191,891 (year 2033),  Features Intersected: SEMINOLE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.947,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 35.1m (115.2ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Culverts: Good,  Operating Rating: 57.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 11
Find on map >>   Show street view

Structure Number: 860147,  Location: 0.25 Mi. W I-95 on SR-822 (Lat: 26.033636,  Lng: -80.167931),  Route carried "on" structure: State highway 822,  Year Built: 1967,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 45,500 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 78,943 (year 2032),  Design Load: HS 20,  Features Intersected: South Fl. Rail Corridor
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.006,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.3m (76.4ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.4m (60.4ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 28.2m (92.5ft),  Out-to-Out Width: 33.6m (110.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860155,  Location: INTRS N TPK SHERIDAN ST (Lat: 26.031944,  Lng: -80.212778),  Route carried "on" structure: County highway 822,  Year Built: 1965,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 45,800 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 57,250 (year 2031),  Design Load: HS 20,  Features Intersected: FLORIDA'S TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.282,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.5m (57.4ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860202,  Location: 1mi. S of Sheridan St. (Lat: 26.018228,  Lng: -80.166964),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: Johnson Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.937,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 28.9m (94.8ft),  Out-to-Out Width: 29.8m (97.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 860228,  Location: Just East of ICW (Lat: 26.011267,  Lng: -80.117928),  Route carried "on" structure: Ramp State highway 820,  Year Built: 1976,  Status: Open,  Structure Length: 13.85m (45.44ft),  Average Daily Traffic: 5,000 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 17,120 (year 2033),  Design Load: HS 20,  Features Intersected: SR-820 (Hollywood Blvd.),  Facility Carried by Structure: RAMP to SB-A1A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 7,  Length of Maximum Span: 27.0m (88.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860229,  Location: Just East of ICW (Lat: 26.013167,  Lng: -80.117792),  Route carried "on" structure: Ramp State highway 820,  Year Built: 1976,  Status: Open,  Structure Length: 14.03m (46.03ft),  Average Daily Traffic: 5,000 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,800 (year 2033),  Design Load: HS 20,  Features Intersected: Hollwood Blvd.
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 0.035,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.5m (21.3ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 7,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 86023,  Location: SR 820 & Intracoastal (Lat: 26.012083,  Lng: -80.119642),  Route carried "on" structure: State highway 820,  Year Built: 1976,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 39.14m (128.41ft),  Average Daily Traffic: 12,000 (year 2011),  Truck Traffic: 4%,  Average Future Daily Traffic: 20,820 (year 2033),  Design Load: HS 20,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: Hollywood Blvd.
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 31.657,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 30 degrees,  Navigation Control: Yes ( Vertical Clearance: 6.4m (21.0ft), Horizontal Clearance: 27.4m (89.9ft)),  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 27,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: August 11,  Critical Feature Inspection Date: August 11,  Underwater Inspection Date: August 11,  Other Special Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860403,  Location: 0.5 MI NO OF HOLLYWD BLVD (Lat: 26.017514,  Lng: -80.212839),  Route carried "on" structure: State highway 91,  Year Built: 1986,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 110,600 (year 2011),  Truck Traffic: 7%,  Average Future Daily Traffic: 191,891 (year 2033),  Design Load: HS 20+Mod,  Features Intersected: JOHNSON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.491,  Lanes on structure: 6,  Lanes under structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 32.0m (105.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 33.5m (109.9ft),  Out-to-Out Width: 35.1m (115.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 46.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860404,  Location: 1 MI NO.OF HOLLYWOOD BLVD (Lat: 26.024786,  Lng: -80.213125),  Route carried "on" structure: State highway 91,  Year Built: 1986,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 110,600 (year 2011),  Truck Traffic: 7%,  Average Future Daily Traffic: 191,891 (year 2033),  Design Load: HS 20+Mod,  Features Intersected: TAFT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.296,  Lanes on structure: 6,  Lanes under structure: 5,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.7m (94.2ft),  Curb-To-Curb Width: 33.5m (109.9ft),  Out-to-Out Width: 35.1m (115.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 86053,  Location: I-95 over Hollywood Blvd (Lat: 26.011222,  Lng: -80.167025),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 7.44m (24.41ft),  Average Daily Traffic: 248,000 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 430,280 (year 2032),  Design Load: HS 20,  Features Intersected: SR-820 Hollywood Blvd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.086,  Lanes on structure: 10,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 50.7m (166.3ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 50.7m (166.3ft),  Out-to-Out Width: 52.2m (171.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 63.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 52.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860574,  Location: 1 mi S of Sheridan on I95 (Lat: 26.024056,  Lng: -80.167450),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: C-10 Hollywood Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.541,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 4.1m (13.5ft), Horizontal Clearance: 12.3m (40.4ft)),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 28.9m (94.8ft),  Out-to-Out Width: 29.9m (98.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 11,  Underwater Inspection Date: July 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860575,  Location: 1 mi S of Sheridan on I95 (Lat: 26.024167,  Lng: -80.167500),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20,  Features Intersected: C-10 Hollywood canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.541,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 4.1m (13.5ft), Horizontal Clearance: 12.3m (40.4ft)),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 28.9m (94.8ft),  Out-to-Out Width: 29.9m (98.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 11,  Underwater Inspection Date: July 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860576,  Location: SB I-95 over Sheridan St. (Lat: 26.033547,  Lng: -80.164511),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 5.47m (17.95ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: SR-822 (Sheridan St.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.616,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 69.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 57.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860577,  Location: NB I-95 over Sheridan St. (Lat: 26.033075,  Lng: -80.164111),  Route carried "on" structure: Interstate 95,  Year Built: 1990,  Status: Open,  Structure Length: 5.47m (17.95ft),  Average Daily Traffic: 136,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 236,828 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: SR-822 (Sheridan St.)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.616,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 69.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 57.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860578,  Location: SR-9 1/4mi N of Sheridan (Lat: 26.040800,  Lng: -80.163564),  Route carried "on" structure: Interstate 95,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 277,000 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 480,595 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: C-10 Spur Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.446,  Lanes on structure: 12,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 50.7m (166.3ft),  Skew: 10 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 58.1m (190.6ft),  Out-to-Out Width: 59.6m (195.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: May 11,  Underwater Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 860599,  Location: Just West of I-95 (Lat: 26.010653,  Lng: -80.168506),  Route carried "on" structure: State highway 820,  Year Built: 1971,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 48,500 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 84,148 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: Hollywood Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.540,  Lanes on structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.9m (88.3ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.5m (21.3ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 39.2m (128.6ft),  Out-to-Out Width: 43.1m (141.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 11,  Underwater Inspection Date: November 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 866301,  Location: 0.5MI N OF SHERIDAN ST. (Lat: 26.040589,  Lng: -80.165831),  Route carried "on" structure: City street 29,  Year Built: 1967,  Status: Posted for load-capacity,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 10,634 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,450 (year 2031),  Features Intersected: C-10 SPUR CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.814,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 15.1m (49.5ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Underwater Inspection Date: March 11,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 866302,  Location: 0.3MI E of CASPER COURT (Lat: 26.037225,  Lng: -80.187919),  Route carried "on" structure: City street ,  Year Built: 1968,  Status: Posted for load-capacity,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 500 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 868 (year 2031),  Design Load: H 20,  Features Intersected: C10 SPUR CANAL,  Facility Carried by Structure: SANDERS ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.5m (21.3ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Underwater Inspection Date: March 11,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 866303,  Location: 0.09MI EAST OF N 28TH AVE (Lat: 26.032319,  Lng: -80.161794),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 1,100 (year 2001),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,909 (year 2031),  Design Load: H 20,  Features Intersected: C-10 CANAL,  Facility Carried by Structure: SHERMAN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 11,  Underwater Inspection Date: Febuary 11,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 866304,  Location: 0.1MI E OF NORTH 28TH AVE (Lat: 26.025886,  Lng: -80.163367),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Posted for load-capacity,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 10,900 (year 1999),  Truck Traffic: 2%,  Average Future Daily Traffic: 17,350 (year 2031),  Features Intersected: C-10 CANAL,  Facility Carried by Structure: TAFT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.332,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 50.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 11,  Underwater Inspection Date: Febuary 11,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 866305,  Location: 0.02 MI W of N 30TH ROAD (Lat: 26.018375,  Lng: -80.169875),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Posted for load-capacity,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 10,900 (year 2001),  Truck Traffic: 2%,  Average Future Daily Traffic: 17,350 (year 2031),  Design Load: H 20,  Features Intersected: C-10 CANAL,  Facility Carried by Structure: JOHNSON ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.813,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 53.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: Febuary 11,  Underwater Inspection Date: Febuary 11,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 860102,  Location: 1mi. S of Sheridan St. (Lat: 26.018617,  Lng: -80.167528),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 10,673 (year 2001),  Truck Traffic: 5%,  Features Intersected: Johnson Street,  Facility Carried by Structure: I-95 (SR-9) SB
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 860104,  Location: .5 miles South of SR-822 (Lat: 26.025989,  Lng: -80.166958),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 2,500 (year 2003),  Truck Traffic: 5%,  Features Intersected: Taft Street,  Facility Carried by Structure: I-95 (SR-9)
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 12,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.3m (66.6ft)

Find on map >>   Show street view

Structure Number: 860145,  Location: 2.1 MI N OF SR-820 (Lat: 26.039358,  Lng: -80.213975),  Route carried "under" structure: Other road 1,  Year Built: 1956,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 2 (year 2011),  Truck Traffic: 8%,  Features Intersected: SEMINOLE DR
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Culvert,  Length of Maximum Span: 4.0m (13.1ft)

Find on map >>   Show street view

Structure Number: 860155,  Location: INTRS N TPK SHERIDAN ST (Lat: 26.031944,  Lng: -80.212778),  Route carried "under" structure: Other road 91,  Year Built: 1965,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 79,400 (year 2003),  Truck Traffic: 5%,  Features Intersected: FLORIDA'S TURNPIKE,  Facility Carried by Structure: SHERIDAN ST(CR822)
Minimum Vertical Clearance: 4.51m (14.80ft),  Kilometerpoint: 7.128,  Lanes on structure: 4,  Lanes under structure: 6,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.5m (57.4ft)

Find on map >>   Show street view

Structure Number: 860202,  Location: 1mi. S of Sheridan St. (Lat: 26.018228,  Lng: -80.166964),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 15,500 (year 2010),  Truck Traffic: 9%,  Features Intersected: Johnson Street,  Facility Carried by Structure: I-95 ( SR-9 ) NB
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 4.155,  Lanes on structure: 6,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 86023,  Location: SR 820 & Intracoastal (Lat: 26.012083,  Lng: -80.119642),  Route carried "under" structure: City street ,  Year Built: 1976,  Structure Length: 39.14m (128.41ft),  Average Daily Traffic: 20 (year 2011),  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: Hollywood Blvd.
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 86023,  Location: SR 820 & Intracoastal (Lat: 26.012083,  Lng: -80.119642),  Route carried "under" structure: State highway A1A,  Year Built: 1976,  Structure Length: 39.14m (128.41ft),  Average Daily Traffic: 22,500 (year 2011),  Truck Traffic: 2%,  Features Intersected: Intracoastal Waterway,  Facility Carried by Structure: Hollywood Blvd.
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 0.412,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Movable - Bascule,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 860403,  Location: 0.5 MI NO OF HOLLYWD BLVD (Lat: 26.017514,  Lng: -80.212839),  Route carried "under" structure: City street ,  Year Built: 1986,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 110,600 (year 2011),  Truck Traffic: 7%,  Features Intersected: JOHNSON ST,  Facility Carried by Structure: SR91 N/S TPK 50.66
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 5.491,  Lanes on structure: 6,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 860404,  Location: 1 MI NO.OF HOLLYWOOD BLVD (Lat: 26.024786,  Lng: -80.213125),  Route carried "under" structure: City street ,  Year Built: 1986,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 110,600 (year 2011),  Truck Traffic: 7%,  Features Intersected: TAFT ST,  Facility Carried by Structure: SR91 N/S TPK 51.14
Minimum Vertical Clearance: 5.06m (16.60ft),  Kilometerpoint: 6.296,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.7m (94.2ft)

Find on map >>   Show street view

Structure Number: 86053,  Location: I-95 over Hollywood Blvd (Lat: 26.011222,  Lng: -80.167025),  Route carried "under" structure: State highway 820,  Year Built: 1990,  Structure Length: 7.44m (24.41ft),  Average Daily Traffic: 48,500 (year 2010),  Truck Traffic: 4%,  Features Intersected: SR-820 Hollywood Blvd,  Facility Carried by Structure: I-95 (SR-9)
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 26.686,  Lanes on structure: 10,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>   Show street view

Structure Number: 860576,  Location: SB I-95 over Sheridan St. (Lat: 26.033547,  Lng: -80.164511),  Route carried "under" structure: State highway 822,  Year Built: 1990,  Structure Length: 5.47m (17.95ft),  Average Daily Traffic: 42,500 (year 2010),  Truck Traffic: 4%,  Features Intersected: SR-822 (Sheridan St.),  Facility Carried by Structure: SB I-95 (SR-9)
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 4.422,  Lanes on structure: 5,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 860577,  Location: NB I-95 over Sheridan St. (Lat: 26.033075,  Lng: -80.164111),  Route carried "under" structure: State highway 822,  Year Built: 1990,  Structure Length: 5.47m (17.95ft),  Average Daily Traffic: 45,500 (year 2010),  Truck Traffic: 3%,  Features Intersected: SR-822 (Sheridan St.),  Facility Carried by Structure: NB I-95 (SR-9)
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 4.397,  Lanes on structure: 5,  Lanes under structure: 10,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Jump to a detailed profile or search site with Google Custom Search
Business Search - 14 Million verified businesses
Search for: near: 

Discuss this city on our hugely popular Florida forum

Back to: Hollywood, FL, Florida, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2013 Advameg, Inc.