National Bridge Inventory (NBI) Statistics
Number of bridges: 24
Total length: 167 meters (548ft)
Total costs: $420,000
Total average daily traffic: 14,748
Total average daily truck traffic: 685
National Bridge Inventory (NBI) Registered Bridges for Kodiak

New bridges - Historical Statistics

  • 1960-1969: 2
  • 1970-1979: 14
  • 1980-1989: 7
  • 1990-1999: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 208,  Location: MILE POINT 6.4 (Lat: 57.618333,  Lng: -152.315000),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 101 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2028),  Design Load: HS 20,  Features Intersected: ROSLYN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.298,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 284,  Location: MILE POINT 10.5 (Lat: 57.641667,  Lng: -152.510000),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 246 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: AMERICAN RIVER,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.811,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 286,  Location: MILE POINT 18.7 (Lat: 57.600000,  Lng: -152.468333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 178 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: DEADMAN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.164,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 287,  Location: MILE POINT 19.5 (Lat: 57.595000,  Lng: -152.456667),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 178 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: OLDS RIVER,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.298,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 29,  Location: MILE POINT 29.6 (Lat: 57.621667,  Lng: -152.265000),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 101 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2028),  Design Load: HS 20,  Features Intersected: EAST FORK TWIN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.598,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 291,  Location: MILE POINT 19.9 (Lat: 57.590000,  Lng: -152.443333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 178 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 400 (year 2028),  Design Load: HS 20,  Features Intersected: KALSIN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.027,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 292,  Location: MILE POINT 22.8 (Lat: 57.605000,  Lng: -152.403333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 101 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2028),  Design Load: HS 20,  Features Intersected: MYRTLE CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.682,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Bridge Improvement Cost: $353,000,  Total Project Cost: $420,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 385,  Location: MILE POINT 9.6 (Lat: 57.651667,  Lng: -152.523333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 246 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,000 (year 2028),  Design Load: HS 20,  Features Intersected: SALT CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.488,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 386,  Location: MILE POINT 10.7 (Lat: 57.640000,  Lng: -152.506667),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 178 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: FELTON CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.157,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 66.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 47,  Location: MILE POINT 9.2 (Lat: 57.655000,  Lng: -152.518333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 246 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2028),  Design Load: HS 20,  Features Intersected: SMALL CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.875,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 983,  Location: MILE POINT 7.5 (Lat: 57.816667,  Lng: -152.621667),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 104 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 150 (year 2028),  Design Load: HS 20,  Features Intersected: RED CLOUD RIVER,  Facility Carried by Structure: ANTON LARSON BAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.012,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 86.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 986,  Location: MILE POINT 8.6 (Lat: 57.795000,  Lng: -152.513333),  Route carried "on" structure: State highway 391,  Year Built: 1995,  Status: Open,  Structure Length: 3.57m (11.71ft),  Average Daily Traffic: 4,863 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,600 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: BUSKIN RIVER NO 5,  Facility Carried by Structure: REZANOF DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.847,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.1m (115.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 80.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 987,  Location: MILE POINT 0.6 (Lat: 57.766667,  Lng: -152.516667),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 650 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 70 (year 2028),  Design Load: HS 20,  Features Intersected: BUSKIN RIVER NO 6,  Facility Carried by Structure: ANTON LARSON BAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.937,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 79.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 988,  Location: MILE POINT 1.5 (Lat: 57.776667,  Lng: -152.530000),  Route carried "on" structure: State highway 391,  Year Built: 1960,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 650 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 70 (year 2028),  Features Intersected: BUSKIN RIVER NO 7,  Facility Carried by Structure: ANTON LARSON BAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.387,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 52.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 989,  Location: MILE POINT 13.6 (Lat: 57.710000,  Lng: -152.565000),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 1,898 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,172 (year 2028),  Design Load: H 20,  Features Intersected: SARGENT CREEK,  Facility Carried by Structure: REZANOF DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.821,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 99,  Location: MILE POINT 0.1 (Lat: 57.706667,  Lng: -152.568333),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 1,281 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,300 (year 2028),  Design Load: H 20,  Features Intersected: RUSSIAN RIVER,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.047,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 992,  Location: MILE POINT 1.7 (Lat: 57.696667,  Lng: -152.556667),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 1,281 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,300 (year 2028),  Design Load: HS 20,  Features Intersected: SALONIE CREEK NO. 1,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.770,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 1189,  Location: MILE POINT 0.1 (Lat: 57.783333,  Lng: -152.400000),  Route carried "on" structure: County highway NSP,  Year Built: 1986,  Status: Open,  Structure Length: 38.22m (125.39ft),  Average Daily Traffic: 1,554 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,800 (year 2028),  Design Load: HS 20,  Features Intersected: KODIAK HARBOR CHANNEL,  Facility Carried by Structure: NEAR ISLAND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 30.7m (100.7ft), Horizontal Clearance: 60.9m (199.8ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 118.9m (390.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 63.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 1274,  Location: MILE POINT 7.2 (Lat: 57.840000,  Lng: -152.443333),  Route carried "on" structure: State highway 389,  Year Built: 1972,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 212 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 275 (year 2028),  Design Load: H 20,  Features Intersected: MONASHKA CREEK,  Facility Carried by Structure: PILLAR CREEK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.565,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 63.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>

Structure Number: 1425,  Location: KODIAK (Lat: 58.621667,  Lng: -152.436667),  Route carried "on" structure: State highway 389,  Year Built: 1965,  Status: Posted for load,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 100 (year 2028),  Design Load: H 20,  Features Intersected: KODIAK CITY DOCK,  Facility Carried by Structure: MARINE HWY ROUTE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 1,  Base Highway Network: Yes,  Toll: On toll road,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 20,  Number Of Approach Spans: 10,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2006,  Underwater Inspection Date: July 2004,  Deck Structure Type: Wood or Timber
Find on map >>

Structure Number: 2095,  Location: NEAR USCG BASE (Lat: 57.785000,  Lng: -152.421667),  Route carried "on" structure: State highway 389,  Year Built: 1988,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 32.00m (104.99ft),  Average Daily Traffic: 100 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 110 (year 2028),  Design Load: H 15,  Features Intersected: KODIAK PIER 2,  Facility Carried by Structure: MARINE HWY ROUTE
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Toll: On toll road,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 46,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 21.7m (71.2ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: Febuary 2007,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 4057,  Location: MILE POINT 28.9 (Lat: 57.618333,  Lng: -152.260000),  Route carried "on" structure: State highway 391,  Year Built: 1975,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 101 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2028),  Features Intersected: WEST FORK TWIN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 46.528,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Very good,  Culverts: Very good,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006
Find on map >>

Structure Number: 4069,  Location: MILE POINT 20.6 (Lat: 57.590000,  Lng: -152.433333),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 101 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2028),  Features Intersected: FRANK CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 33.186,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006
Find on map >>

Structure Number: 1189,  Location: MILE POINT 0.1 (Lat: 57.783333,  Lng: -152.400000),  Route carried "under" structure: City street ,  Year Built: 1986,  Structure Length: 38.22m (125.39ft),  Average Daily Traffic: 100 (year 2005),  Features Intersected: KODIAK HARBOR CHANNEL,  Facility Carried by Structure: NEAR ISLAND ROAD
Minimum Vertical Clearance: 7.32m (24.02ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 118.9m (390.1ft)