Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Kodiak, Alaska (AK)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 135m443ftTotal length
  • $420,000Total costs
  • 10,330Total average daily traffic
  • 466Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Kodiak
  • No street view available for this location

New bridges - Historical Statistics

  • 11960-1969
  • 71970-1979
  • 61980-1989

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>   Show street view

Structure Number: 284,  Location: MILE POINT 10.5 (Lat: 57.640964,  Lng: -152.513111),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 600 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 600 (year 2032),  Design Load: HS 20,  Features Intersected: AMERICAN RIVER,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.811,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 286,  Location: MILE POINT 18.7 (Lat: 57.594561,  Lng: -152.479981),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 420 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 500 (year 2032),  Design Load: HS 20,  Features Intersected: DEADMAN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.164,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 84.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 291,  Location: MILE POINT 19.9 (Lat: 57.583547,  Lng: -152.460089),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 420 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 400 (year 2032),  Design Load: HS 20,  Features Intersected: KALSIN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.027,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 292,  Location: MILE POINT 22.8 (Lat: 57.603997,  Lng: -152.405456),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 250 (year 2013),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2032),  Design Load: HS 20,  Features Intersected: MYRTLE CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.682,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 85.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Bridge Improvement Cost: $353,000,  Total Project Cost: $420,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 983,  Location: MILE POINT 7.5 (Lat: 57.816586,  Lng: -152.625639),  Route carried "on" structure: State highway 391,  Year Built: 1974,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 100 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 150 (year 2032),  Design Load: HS 20,  Features Intersected: RED CLOUD RIVER,  Facility Carried by Structure: ANTON LARSEN BAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.012,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 84.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 989,  Location: MILE POINT 13.6 (Lat: 57.709164,  Lng: -152.568464),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 2,370 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,500 (year 2032),  Design Load: HS 20,  Features Intersected: SARGENT CREEK,  Facility Carried by Structure: REZANOF DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.821,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 99,  Location: MILE POINT 0.1 (Lat: 57.706322,  Lng: -152.571353),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 1,810 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,000 (year 2032),  Design Load: HS 20,  Features Intersected: RUSSIAN RIVER,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.047,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 992,  Location: MILE POINT 1.7 (Lat: 57.696308,  Lng: -152.560664),  Route carried "on" structure: State highway 391,  Year Built: 1980,  Status: Open,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 1,810 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,000 (year 2032),  Design Load: HS 20,  Features Intersected: SALONIE CREEK NO. 1,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.770,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Inventory Rating: 44.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1189,  Location: MILE POINT 0.1 (Lat: 57.788697,  Lng: -152.397369),  Route carried "on" structure: County highway NSP,  Year Built: 1986,  Status: Open,  Structure Length: 38.21m (125.36ft),  Average Daily Traffic: 1,790 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,800 (year 2032),  Design Load: HS 20,  Features Intersected: KODIAK HARBOR CHANNEL,  Facility Carried by Structure: NEAR ISLAND ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 20 degrees,  Navigation Control: Yes ( Vertical Clearance: 30.7m (100.7ft), Horizontal Clearance: 60.9m (199.8ft)),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 118.9m (390.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Excellent,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1274,  Location: MILE POINT 7.2 (Lat: 57.841397,  Lng: -152.445467),  Route carried "on" structure: State highway 389,  Year Built: 1972,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 210 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 275 (year 2032),  Design Load: HS 20,  Features Intersected: MONASHKA CREEK,  Facility Carried by Structure: PILLAR CREEK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.565,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 1425,  Location: KODIAK (Lat: 57.787189,  Lng: -152.402539),  Route carried "on" structure: State highway 389,  Year Built: 1965,  Status: Posted for load,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 100 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 120 (year 2032),  Design Load: H 20,  Features Intersected: KODIAK CITY DOCK,  Facility Carried by Structure: MARINE HWY ROUTE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 1,  Toll: On toll road,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 20,  Number Of Approach Spans: 10,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 16.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 14,  Underwater Inspection Date: July 14,  Deck Structure Type: Wood or Timber
Find on map >>   Show street view

Structure Number: 2095,  Location: NEAR USCG BASE (Lat: 57.783725,  Lng: -152.428325),  Route carried "on" structure: State highway 389,  Year Built: 1988,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 28.19m (92.49ft),  Average Daily Traffic: 100 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 110 (year 2032),  Features Intersected: KODIAK PIER 2,  Facility Carried by Structure: MARINE HWY ROUTE
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Toll: On toll road,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 46,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Inventory Rating: 75.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 14,  Underwater Inspection Date: July 14,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4057,  Location: MILE POINT 28.9 (Lat: 57.620997,  Lng: -152.265164),  Route carried "on" structure: State highway 391,  Year Built: 1975,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 250 (year 2013),  Truck Traffic: 1%,  Average Future Daily Traffic: 150 (year 2032),  Features Intersected: WEST FORK TWIN CREEK,  Facility Carried by Structure: CHINIAK HIGHWAY
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 46.528,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 14
Find on map >>   Show street view

Structure Number: 1189,  Location: MILE POINT 0.1 (Lat: 57.788697,  Lng: -152.397369),  Route carried "under" structure: City street ,  Year Built: 1986,  Structure Length: 38.21m (125.36ft),  Average Daily Traffic: 100 (year 2013),  Features Intersected: KODIAK HARBOR CHANNEL,  Facility Carried by Structure: NEAR ISLAND ROAD
Minimum Vertical Clearance: 7.32m (24.02ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 118.9m (390.1ft)