Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lincoln Village, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 118ft / 35.9mTotal length
  • 449,899Total average daily traffic
  • 78,866Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lincoln Village
  • No street view available for this location

Average Bridge Daily Traffic in Lincoln Village, OH
Average Bridge Truck Traffic in Lincoln Village, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Very good
  • 85.7%Good
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 85.7%Good
Find on map >>   Show street view

Structure Number: 2512181,  Location: 0.77 MI N OF US40 (Lat: 39.963561,  Lng: -83.119189),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 6.19m (20.31ft),  Average Daily Traffic: 39,643 (year 2015),  Truck Traffic: 21%,  Average Future Daily Traffic: 55,024 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NS RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.569,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2512211,  Location: 0.77 MI N OF US40 (Lat: 39.963561,  Lng: -83.119450),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 39,643 (year 2015),  Truck Traffic: 21%,  Average Future Daily Traffic: 55,024 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER NS RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.569,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 251227,  Location: 0.04 MI E OF SR270 (Lat: 39.952489,  Lng: -83.118669),  Route carried "on" structure: Ramp Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 8,060 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,187 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: US-40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.330,  Lanes on structure: 1,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 25123,  Location: 7.04 MI N OF I71 (Lat: 39.952719,  Lng: -83.119011),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 25,007 (year 2015),  Truck Traffic: 34%,  Average Future Daily Traffic: 34,710 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER USR 40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.330,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 58.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2512335,  Location: 7.04 MI N OF I71 (Lat: 39.952700,  Lng: -83.119269),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 25,007 (year 2015),  Truck Traffic: 34%,  Average Future Daily Traffic: 34,710 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVER USR 40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.330,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2512394,  Location: 0.3 MI S OF US40 (Lat: 39.950600,  Lng: -83.119361),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 4.22m (13.85ft),  Average Daily Traffic: 25,007 (year 2015),  Truck Traffic: 34%,  Average Future Daily Traffic: 34,710 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OVR RMP USR40E TO IR270N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.121,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.6m (64.3ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 19.6m (64.3ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 2512424,  Location: 0.13 MI S OF US40 (Lat: 39.950561,  Lng: -83.119481),  Route carried "on" structure: Interstate 270,  Year Built: 1969,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 25,007 (year 2015),  Truck Traffic: 34%,  Average Future Daily Traffic: 34,710 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: OV RMP USR40E TO IR270N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.121,  Lanes on structure: 3,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 251227,  Location: 0.04 MI E OF SR270 (Lat: 39.952489,  Lng: -83.118669),  Route carried "under" structure: US 40,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 41,063 (year 2017),  Truck Traffic: 3%,  Features Intersected: RAMP US40 TO 270N
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 10.091,  Lanes on structure: 1,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 25123,  Location: 7.04 MI N OF I71 (Lat: 39.952719,  Lng: -83.119011),  Route carried "under" structure: US 40,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 39,531 (year 2015),  Truck Traffic: 5%,  Features Intersected: IR 270NB,  Facility Carried by Structure: I-270
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 100.584,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 2512335,  Location: 7.04 MI N OF I71 (Lat: 39.952700,  Lng: -83.119269),  Route carried "under" structure: US 40,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 39,531 (year 2015),  Truck Traffic: 5%,  Features Intersected: IR 270SB,  Facility Carried by Structure: I-270
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 100.262,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.8m (55.1ft)

Find on map >>   Show street view

Structure Number: 2512394,  Location: 0.3 MI S OF US40 (Lat: 39.950600,  Lng: -83.119361),  Route carried "under" structure: Ramp Interstate 270,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 71,200 (year 2010),  Truck Traffic: 16%,  Features Intersected: I-270 NB
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 111.206,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 2512424,  Location: 0.13 MI S OF US40 (Lat: 39.950561,  Lng: -83.119481),  Route carried "under" structure: Ramp Interstate 270,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 71,200 (year 2010),  Truck Traffic: 16%,  Features Intersected: I-270 SB
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 111.206,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.8m (42.0ft)

Discuss Lincoln Village, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.