U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Linden, New Jersey (NJ) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Linden, NJ, New Jersey, New Jersey forum, All US cities.





Parts: 1, 2


National Bridge Inventory (NBI) Statistics
Number of bridges: 69
Total length: 779 meters (2,556ft)
Total costs: $1,500,000
Total average daily traffic: 2,716,491
Total average daily truck traffic: 333,864
National Bridge Inventory (NBI) Registered Bridges for Linden

New bridges - Historical Statistics

  • 1920-1929: 2
  • 1930-1939: 1
  • 1940-1949: 0
  • 1950-1959: 18
  • 1960-1969: 9
  • 1970-1979: 25
  • 1980-1989: 12
  • 1990-1999: 2

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 2001154,  Location: 2.2 MI.N.OF RAHWAY RIVER (Lat: 40.624183,  Lng: -74.245333),  Route carried "on" structure: US 1,  Year Built: 1984,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 70,494 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 84,592 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 65.790,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.9m (52.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 30.5m (100.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2001155,  Location: 3.1 MI N OF RAHWAY RIVER (Lat: 40.624183,  Lng: -74.245333),  Route carried "on" structure: US 1,  Year Built: 1967,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 70,494 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 84,592 (year 2026),  Design Load: HS 20,  Features Intersected: Peach Orchard Brook
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.303,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 31.4m (103.0ft),  Out-to-Out Width: 37.8m (124.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009001,  Location: NEAR EDDY AVENUE (Lat: 40.623611,  Lng: -74.244167),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 860 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,030 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: ELEVENTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 0.0m,  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009004,  Location: NEAR COOLIDGE STREET (Lat: 40.625000,  Lng: -74.250833),  Route carried "on" structure: City street ,  Year Built: 1978,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 1,610 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,930 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: MUNSELL AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009005,  Location: NEAR TWELFTH STREET (Lat: 40.623333,  Lng: -74.242222),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 2.71m (8.89ft),  Average Daily Traffic: 1,000 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,200 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: WINANS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 200901,  Location: AT FAY AVENUE (Lat: 40.651389,  Lng: -74.230556),  Route carried "on" structure: County highway 514,  Year Built: 1931,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 12,970 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 15,570 (year 2026),  Features Intersected: STORM SEWER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.622,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 7 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 4.0m (13.1ft),  Right: 4.0m (13.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009011,  Location: NEAR BROOK ST (Lat: 40.630000,  Lng: -74.256667),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 5,470 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 6,560 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: BLANCKE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 4.4m (14.4ft),  Right: 3.9m (12.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 2009013,  Location: AT LUMBER STREET (Lat: 40.628889,  Lng: -74.256111),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 2,510 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,010 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: PRICE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 4.6m (15.1ft),  Right: 4.6m (15.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 54.9m (180.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009014,  Location: NEAR LUMBER STREET (Lat: 40.628056,  Lng: -74.255278),  Route carried "on" structure: County highway 514,  Year Built: 1925,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 12,080 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 14,500 (year 2026),  Features Intersected: WEST BROOK,  Facility Carried by Structure: ELIZABETH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 65.146,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009015,  Location: 100 FT NORTH OF RR BRIDGE (Lat: 40.641389,  Lng: -74.237778),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 12,100 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 14,520 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: PEACH ORCHARD BROOK,  Facility Carried by Structure: LINDEN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.950,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009019,  Location: NEAR FIFTEENTH STREET (Lat: 40.623611,  Lng: -74.240000),  Route carried "on" structure: County highway 617,  Year Built: 1963,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 13,780 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,530 (year 2026),  Design Load: HS 20,  Features Intersected: WEST BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.883,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 3.3m (10.8ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009024,  Location: AT CHANDLER AVENUE (Lat: 40.646667,  Lng: -74.248333),  Route carried "on" structure: City street ,  Year Built: 1922,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 1,030 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,240 (year 2026),  Features Intersected: PEACH ORCHARD BROOK,  Facility Carried by Structure: UNION STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 29.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009035,  Location: NEAR COOLIDGE STREET (Lat: 40.626667,  Lng: -74.253333),  Route carried "on" structure: City street ,  Year Built: 1973,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 11,630 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 13,960 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: LINDEN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.074,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009037,  Location: NEAR ELM STREET (Lat: 40.631667,  Lng: -74.260000),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 734 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 880 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: BROOK STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009039,  Location: NEAR KNOPF STREET (Lat: 40.630000,  Lng: -74.257222),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 520 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 624 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: BROOK STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.5m (8.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 200904,  Location: NEAR AINSWORTH STREET (Lat: 40.633333,  Lng: -74.261389),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 580 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 700 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: CURTIS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb or Sidewalk Widths: Left: 4.0m (13.1ft),  Right: 4.0m (13.1ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006
Find on map >>

Structure Number: 2009042,  Location: NEAR WOOD AVENUE (Lat: 40.635000,  Lng: -74.262222),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 570 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 680 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: GIBBONS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 2009044,  Location: NEAR BROOK STREET (Lat: 40.632222,  Lng: -74.260556),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 3,400 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,080 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: HENRY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009045,  Location: NEAR BROOK STREET (Lat: 40.630833,  Lng: -74.260000),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 790 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 950 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: ELM STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009046,  Location: NEAR BROOK STREET (Lat: 40.630000,  Lng: -74.256667),  Route carried "on" structure: City street ,  Year Built: 1986,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,320 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,580 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: KNOPF STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009048,  Location: NEAR STILES STREET (Lat: 40.625000,  Lng: -74.248333),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 2,350 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,820 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK,  Facility Carried by Structure: STIMPSON AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 200905,  Location: NEAR SIXTEENTH STREET (Lat: 40.624167,  Lng: -74.237222),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 3,440 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,130 (year 2026),  Features Intersected: WEST BROOK,  Facility Carried by Structure: CLINTON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 2.8m (9.2ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 2009074,  Location: NEAR GIBBONS STREET (Lat: 40.635833,  Lng: -74.262222),  Route carried "on" structure: County highway 617,  Year Built: 1982,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 20,760 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 24,910 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: WEST BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.200,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 4.8m (15.7ft),  Right: 4.8m (15.7ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 2009113,  Location: NEAR SHERMAN STREET. (Lat: 40.645833,  Lng: -74.240000),  Route carried "on" structure: City street ,  Year Built: 1956,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 200 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 240 (year 2026),  Features Intersected: PEACH ORCHARD BROOK,  Facility Carried by Structure: HUSSA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels
Find on map >>

Structure Number: 2015152,  Location: 0.56 MI E OF RT 1&9 JCT (Lat: 40.641944,  Lng: -74.221111),  Route carried "on" structure: Interstate 278,  Year Built: 1966,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 24,397 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 29,807 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: PARK AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.917,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 61.6m (202.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 2015153,  Location: 1.4 MI WEST OF NJTPK JCT (Lat: 40.640833,  Lng: -74.230000),  Route carried "on" structure: Ramp Interstate 278,  Year Built: 1967,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 12,087 (year 2007),  Truck Traffic: 9%,  Average Future Daily Traffic: 14,739 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: US 1&9 NORTHBOUND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 204916,  Location: 6280 FT N.OF SIRT OVER1&9 (Lat: 40.648889,  Lng: -74.231389),  Route carried "on" structure: County highway 616,  Year Built: 1986,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 31,000 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 37,000 (year 2026),  Features Intersected: AMTRAK NE CORRIDOR,  Facility Carried by Structure: PARK AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.285,  Lanes on structure: 4,  Base Highway Network: Yes,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 38.9m (127.6ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: M09623N,  Location: .4 MI N INTERCHANGE 12 (Lat: 40.600000,  Lng: -74.231667),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 15.45m (50.69ft),  Average Daily Traffic: 52,000 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 62,400 (year 2027),  Design Load: HS 20,  Features Intersected: RAHWAY RIVER,  Facility Carried by Structure: NJTPK SNI RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.883,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 10.7m (35.1ft), Horizontal Clearance: 21.3m (69.9ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09623S,  Location: .4 MI N INTERCHANGE 12 (Lat: 40.600000,  Lng: -74.231667),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 15.42m (50.59ft),  Average Daily Traffic: 52,000 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 62,400 (year 2027),  Design Load: HS 20,  Features Intersected: RAHWAY RIVER,  Facility Carried by Structure: NJ TPK NSI RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.883,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 1 degrees,  Navigation Control: Yes ( Vertical Clearance: 10.7m (35.1ft), Horizontal Clearance: 21.3m (69.9ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09639,  Location: .16 MI N RAHWAY RIVER (Lat: 40.600000,  Lng: -74.231667),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 194,261 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 237,036 (year 2027),  Design Load: HS 20,  Features Intersected: CENTRAL RAILROAD OF NJ,  Facility Carried by Structure: NJ TURNPIKE RWYS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 155.121,  Lanes on structure: 14,  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: Private,  Approaching Roadway Width: 155.8m (511.2ft),  Skew: 35 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 155.6m (510.5ft),  Out-to-Out Width: 157.4m (516.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Bridge Improvement Cost: $1,260,000,  Roadway Improvement Cost: $225,000,  Total Project Cost: $1,500,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09718A,  Location: 1 MI N RAHWAY RIVER (Lat: 40.611667,  Lng: -74.225000),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 350 (year 2007),  Truck Traffic: 15%,  Average Future Daily Traffic: 420 (year 2027),  Design Load: HS 20,  Features Intersected: NJ.TPK.NSO,NSI,SNI,SNO,  Facility Carried by Structure: NJ TPK 97 U-TURN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 83.428,  Lanes on structure: 2,  Lanes under structure: 12,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: M09719E,  Location: 1 MI N RAHWAY RIVER (Lat: 40.611667,  Lng: -74.223333),  Route carried "on" structure: City street ,  Year Built: 1950,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 27,600 (year 2007),  Truck Traffic: 30%,  Average Future Daily Traffic: 33,100 (year 2027),  Design Load: H 15,  Features Intersected: CENTRAL RAILROAD OF NJ,  Facility Carried by Structure: WOOD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Toll Authority,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.3m (50.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M0972,  Location: 1 MI N RAHWAY RIVER (Lat: 40.611667,  Lng: -74.225000),  Route carried "on" structure: City street ,  Year Built: 1950,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 27,600 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 33,100 (year 2027),  Design Load: H 20,  Features Intersected: NJ TURNPIKE,  Facility Carried by Structure: WOOD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Toll Authority,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09754N,  Location: 1.3 MI. N. RAHWAY RIVER (Lat: 40.616667,  Lng: -74.221667),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 63,500 (year 2007),  Average Future Daily Traffic: 76,200 (year 2027),  Design Load: H 20,  Features Intersected: PYLES CREEK,  Facility Carried by Structure: NJTPK SNI ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 83.991,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 17.8m (58.4ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2007,  Underwater Inspection Date: March 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09754S,  Location: 1.3 MI. N.RAHWAY RIVER (Lat: 40.616667,  Lng: -74.221667),  Route carried "on" structure: Interstate 95,  Year Built: 1969,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 63,500 (year 2007),  Average Future Daily Traffic: 76,200 (year 2027),  Design Load: HS 20,  Features Intersected: PYLES CREEK,  Facility Carried by Structure: NJTPK NSI ROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 83.991,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2007,  Underwater Inspection Date: July 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09848,  Location: 2.2 MI N RAHWAY RIVER (Lat: 40.628333,  Lng: -74.215000),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 126,900 (year 2007),  Average Future Daily Traffic: 152,300 (year 2027),  Design Load: HS 20,  Features Intersected: MORSES CREEK,  Facility Carried by Structure: NJTPK NSI-SNI RWYS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.504,  Lanes on structure: 6,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 34.1m (111.9ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.3m (83.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.0m,  Curb-To-Curb Width: 34.1m (111.9ft),  Out-to-Out Width: 36.0m (118.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2007,  Underwater Inspection Date: July 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09848N,  Location: 2.2 MI N RAHWAY RIVER (Lat: 40.628333,  Lng: -74.215000),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 5.61m (18.41ft),  Average Daily Traffic: 59,800 (year 2007),  Truck Traffic: 29%,  Average Future Daily Traffic: 71,800 (year 2027),  Design Load: HS 20,  Features Intersected: MORSES CREEK,  Facility Carried by Structure: NJ TPK SNO RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.504,  Lanes on structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2007,  Critical Feature Inspection Date: October 2007,  Underwater Inspection Date: July 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09848S,  Location: 2.2 MI N RAHWAY RIVER (Lat: 40.628333,  Lng: -74.215000),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 7.41m (24.31ft),  Average Daily Traffic: 59,800 (year 2007),  Truck Traffic: 29%,  Average Future Daily Traffic: 71,800 (year 2027),  Design Load: HS 20,  Features Intersected: MORSES CREEK,  Facility Carried by Structure: NJ TPK NSO RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.504,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.8m (124.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.0m,  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Critical Feature Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09859,  Location: 2.75 MI N RAHWAY RIVER (Lat: 40.636667,  Lng: -74.210000),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 194,261 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 237,036 (year 2027),  Design Load: HS 20,  Features Intersected: ESSO SALT WATER LINES,  Facility Carried by Structure: NJ TPK RWYS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 158.662,  Lanes on structure: 12,  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: Private,  Approaching Roadway Width: 80.8m (265.1ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 79.6m (261.2ft),  Out-to-Out Width: 80.6m (264.4ft)

Condition: Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09862A,  Location: 1.1 MI S ELIZABETH RIVER (Lat: 40.628333,  Lng: -74.215000),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1992,  Status: Open,  Structure Length: 14.81m (48.59ft),  Average Daily Traffic: 8,000 (year 2007),  Truck Traffic: 24%,  Average Future Daily Traffic: 9,600 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: MORSES CREEK,  Facility Carried by Structure: INT 13 RAMP SOT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.504,  Lanes on structure: 1,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 39.6m (129.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: M09876,  Location: 3 MI N RAHWAY RIVER (Lat: 40.640000,  Lng: -74.208333),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Status: Open,  Structure Length: 31.00m (101.71ft),  Average Daily Traffic: 126,900 (year 2007),  Average Future Daily Traffic: 152,300 (year 2027),  Design Load: HS 20,  Features Intersected: RAILROAD AVE & CRR OF NJ,  Facility Carried by Structure: NJTPK NSI-SNI RWYS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.955,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 40.5m (132.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 15,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 40.6m (133.2ft),  Out-to-Out Width: 42.5m (139.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Critical Feature Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09876N,  Location: .95 MI S ELIZABETH RIVER (Lat: 40.631667,  Lng: -74.213333),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 74.80m (245.41ft),  Average Daily Traffic: 67,900 (year 2005),  Truck Traffic: 29%,  Average Future Daily Traffic: 81,500 (year 2027),  Design Load: HS 20,  Features Intersected: RAILROAD AVE & CRR OF NJ,  Facility Carried by Structure: NJ TPK SNO RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.955,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 23.9m (78.4ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 33,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 23.9m (78.4ft),  Out-to-Out Width: 25.8m (84.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Critical Feature Inspection Date: September 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09876S,  Location: 3 MI N RAHWAY RIVER (Lat: 40.640000,  Lng: -74.208333),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 29.87m (98.00ft),  Average Daily Traffic: 59,800 (year 2007),  Truck Traffic: 29%,  Average Future Daily Traffic: 71,800 (year 2027),  Design Load: HS 20,  Features Intersected: RAILROAD AVE.&CRR OF NJ,  Facility Carried by Structure: NJTPK NSO RWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.955,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 20.6m (67.6ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 37.5m (123.0ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 22.4m (73.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Critical Feature Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M09905A,  Location: .55 MI S ELIZABETH RIVER (Lat: 40.636667,  Lng: -74.210000),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 42.03m (137.89ft),  Average Daily Traffic: 8,000 (year 2007),  Truck Traffic: 24%,  Average Future Daily Traffic: 9,600 (year 2027),  Design Load: HS 20,  Features Intersected: NJ TPK SNO RWY,  Facility Carried by Structure: NJTPK INT.13 R.SOT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 86.422,  Lanes on structure: 1,  Lanes under structure: 3,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 18,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 83.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Critical Feature Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: M09909,  Location: .65 MI S ELIZABETH RIVER (Lat: 40.636667,  Lng: -74.210000),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 194,261 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 237,036 (year 2027),  Design Load: HS 20,  Features Intersected: ESSO PIPES & CRR OF NJ,  Facility Carried by Structure: NJ TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 159.470,  Lanes on structure: 13,  Toll: On toll road,  Owner: State Toll Authority,  Maintenance Responsibility: Private,  Approaching Roadway Width: 80.8m (265.1ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 79.6m (261.2ft),  Out-to-Out Width: 80.6m (264.4ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous

Parts: 1, 2

Discuss this city on our hugely popular New Jersey forum

Back to: Linden, NJ, New Jersey, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.