Bridge Statistics for Lock Haven, Pennsylvania (PA) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Lock Haven, PA, Pennsylvania, Pennsylvania forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 10 Total length: 122 meters (400ft) Total costs: $527,000 Total average daily traffic: 36,686 Total average daily truck traffic: 2,678 National Bridge Inventory (NBI) Registered Bridges for Lock Haven
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 18012010600352, Location: CITY OF LOCK HAVEN (Lat: 41.134750, Lng: -77.443086), Route carried "on" structure: Bypass State highway 120, Year Built: 1980, Status: Open, Structure Length: 2.59m (8.50ft), Average Daily Traffic: 6,709 (year 2007), Truck Traffic: 8%, Average Future Daily Traffic: 7,700 (year 2025), Design Load: H 15, Features Intersected: BALD EAGLE STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 78.541, Lanes on structure: 4, Lanes under structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 20.7m (67.9ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 1, Length of Maximum Span: 25.6m (84.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 20.7m (67.9ft), Out-to-Out Width: 21.9m (71.9ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Fair, Inventory Rating: 18.1 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 18012010600702, Location: CITY OF LOCK HAVEN (Lat: 41.133806, Lng: -77.443214), Route carried "on" structure: Spur State highway 120, Year Built: 1980, Status: Open, Structure Length: 5.12m (16.80ft), Average Daily Traffic: 6,709 (year 2007), Truck Traffic: 8%, Average Future Daily Traffic: 7,700 (year 2025), Design Load: H 15, Features Intersected: NORFOLK AND SOUTHERN Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 78.541, Lanes on structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 20.7m (67.9ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 23.8m (78.1ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 20.7m (67.9ft), Out-to-Out Width: 21.9m (71.9ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 57.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 33.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 180120107, Location: CITY OF LOCK HAVEN (Lat: 41.132583, Lng: -77.443253), Route carried "on" structure: Spur State highway 120, Year Built: 1980, Status: Open, Structure Length: 3.29m (10.79ft), Average Daily Traffic: 6,709 (year 2007), Truck Traffic: 8%, Average Future Daily Traffic: 7,700 (year 2025), Design Load: H 15, Features Intersected: WALNUT STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 78.888, Lanes on structure: 5, Lanes under structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 24.4m (80.1ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 32.0m (105.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 24.4m (80.1ft), Out-to-Out Width: 25.6m (84.0ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 13.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 3.29m (10.79ft), Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Bridge Improvement Cost: $39,000, Roadway Improvement Cost: $250,000, Total Project Cost: $527,000, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 180120108, Location: CITY OF LOCK HAVEN (Lat: 41.127289, Lng: -77.443639), Route carried "on" structure: Spur State highway 120, Year Built: 1980, Status: Open, Structure Length: 4.66m (15.29ft), Average Daily Traffic: 3,474 (year 2007), Truck Traffic: 9%, Average Future Daily Traffic: 8,034 (year 2025), Design Load: H 15, Features Intersected: N & S/NIT AND BALD EAGLE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 79.201, Lanes on structure: 3, Owner: State Highway Agency, Approaching Roadway Width: 16.2m (53.1ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 17.4m (57.1ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 16.5m (54.1ft), Out-to-Out Width: 17.5m (57.4ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 72.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 38.1 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 1801201081, Location: CITY OF LOCK HAVEN (Lat: 41.130139, Lng: -77.441778), Route carried "on" structure: Spur State highway 120, Year Built: 1980, Status: Open, Structure Length: 4.66m (15.29ft), Average Daily Traffic: 3,235 (year 2007), Truck Traffic: 7%, Average Future Daily Traffic: 8,034 (year 2025), Design Load: H 15, Features Intersected: N & S/NIT AND BALD EAGLE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 79.186, Lanes on structure: 3, Owner: State Highway Agency, Approaching Roadway Width: 16.2m (53.1ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 17.4m (57.1ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.3m (1.0ft), Curb-To-Curb Width: 16.5m (54.1ft), Out-to-Out Width: 17.1m (56.1ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 66.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 180150027, Location: CONSTITUTION BRIDGE (Lat: 41.137472, Lng: -77.426989), Route carried "on" structure: State highway 150, Year Built: 1999, Status: Open, Structure Length: 35.42m (116.21ft), Average Daily Traffic: 6,054 (year 2008), Truck Traffic: 7%, Average Future Daily Traffic: 13,150 (year 2026), Design Load: H 15, Features Intersected: WATER ST,W B SUSQUEHANNA Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 16.744, Lanes on structure: 2, Lanes under structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 13.1m (43.0ft), Skew: 1 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 8, Length of Maximum Span: 44.5m (146.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.1m (0.3ft), Curb-To-Curb Width: 11.0m (36.1ft), Out-to-Out Width: 13.7m (44.9ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Very good, Channel: Very good, Inventory Rating: 40.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: High priority of corrective action, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: April 2007, Underwater Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 18066400100088, Location: CITY OF LOCK HAVEN (Lat: 41.138139, Lng: -77.442439), Route carried "on" structure: State highway 664, Year Built: 1986, Status: Open, Structure Length: 25.05m (82.19ft), Average Daily Traffic: 3,646 (year 2007), Truck Traffic: 3%, Average Future Daily Traffic: 5,181 (year 2025), Design Load: H 15, Features Intersected: W BR SUSQUEHANNA RIVER Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 62.2m (204.1ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 8.5m (27.9ft), Out-to-Out Width: 11.4m (37.4ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Fair, Operating Rating: 60.8 metric tons, Inventory Rating: 40.8 metric tons, Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 18012010600352, Location: CITY OF LOCK HAVEN (Lat: 41.134750, Lng: -77.443086), Route carried "under" structure: City street , Year Built: 1980, Structure Length: 2.59m (8.50ft), Average Daily Traffic: 50 (year 2003), Features Intersected: BALD EAGLE STREET, Facility Carried by Structure: SR 120-PA 120 Minimum Vertical Clearance: 4.45m (14.60ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Length of Maximum Span: 25.6m (84.0ft) Find on map >>
Structure Number: 180120107, Location: CITY OF LOCK HAVEN (Lat: 41.132583, Lng: -77.443253), Route carried "under" structure: City street , Year Built: 1980, Structure Length: 3.29m (10.79ft), Average Daily Traffic: 50 (year 2003), Features Intersected: WALNUT STREET, Facility Carried by Structure: SR 120-PA 120 Minimum Vertical Clearance: 4.29m (14.07ft), Kilometerpoint: 0.000, Lanes on structure: 5, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.0m (105.0ft) Find on map >>
Structure Number: 180150027, Location: CONSTITUTION BRIDGE (Lat: 41.137472, Lng: -77.426989), Route carried "under" structure: City street , Year Built: 1999, Structure Length: 35.42m (116.21ft), Average Daily Traffic: 50 (year 2003), Truck Traffic: 1%, Features Intersected: WATER ST,W B SUSQUEHANNA, Facility Carried by Structure: SR 150-PA 150 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 44.5m (146.0ft) Discuss this city on our hugely popular Pennsylvania forum Back to: Lock Haven, PA, Pennsylvania, All US cities.
|
![]() |