Bridge Statistics for Luzerne, Pennsylvania (PA) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Luzerne, PA, Pennsylvania, Pennsylvania forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 12 Total length: 85 meters (279ft) Total costs: $4,884,000 Total average daily traffic: 185,028 Total average daily truck traffic: 10,260 National Bridge Inventory (NBI) Registered Bridges for Luzerne
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 40030906401826, Location: LUZERNE BO .2 M N SR 1015 (Lat: 41.277639, Lng: -75.888383), Route carried "on" structure: State highway 309, Year Built: 1980, Status: Open, Structure Length: 4.82m (15.81ft), Average Daily Traffic: 42,748 (year 2008), Truck Traffic: 5%, Average Future Daily Traffic: 58,377 (year 2026), Design Load: H 15, Features Intersected: LUZ CO RAIL AUTHORITY Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 44.693, Lanes on structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 30.5m (100.1ft), Skew: 31 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 16.2m (53.1ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 30.5m (100.1ft), Out-to-Out Width: 32.3m (106.0ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 78.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 24.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 4.82m (15.81ft), Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Bridge Improvement Cost: $42,000, Roadway Improvement Cost: $123,000, Total Project Cost: $564,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4003090644, Location: LUZ BORO OVER VAUGHN ST (Lat: 41.278222, Lng: -75.889719), Route carried "on" structure: State highway 309, Year Built: 1980, Status: Open, Structure Length: 6.04m (19.82ft), Average Daily Traffic: 42,748 (year 2008), Truck Traffic: 5%, Average Future Daily Traffic: 58,377 (year 2026), Design Load: H 15, Features Intersected: VAUGHN ST, ABANDONED RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 45.369, Lanes on structure: 6, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 30.5m (100.1ft), Skew: 32 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 27.4m (89.9ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 30.4m (99.7ft), Out-to-Out Width: 32.3m (106.0ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 76.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 28.1 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 6.04m (19.82ft), Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Bridge Improvement Cost: $61,000, Roadway Improvement Cost: $181,000, Total Project Cost: $828,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 40030906441239, Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279722, Lng: -75.894722), Route carried "on" structure: State highway 309, Year Built: 1980, Status: Open, Structure Length: 15.76m (51.71ft), Average Daily Traffic: 35,582 (year 2008), Truck Traffic: 6%, Average Future Daily Traffic: 48,833 (year 2026), Design Load: H 15, Features Intersected: SR 1013 UNION STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 45.369, Lanes on structure: 4, Lanes under structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 24.1m (79.1ft), Skew: 35 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 32.6m (107.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 24.2m (79.4ft), Out-to-Out Width: 26.2m (86.0ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Fair, Inventory Rating: 53.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Superior to present desirable criteria, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 15.76m (51.71ft), Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Bridge Improvement Cost: $130,000, Roadway Improvement Cost: $382,000, Total Project Cost: $1,752,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4003090654, Location: LUZERNE BORO OVER SR 8039 (Lat: 41.287167, Lng: -75.904231), Route carried "on" structure: State highway 309, Year Built: 1980, Status: Open, Structure Length: 5.33m (17.49ft), Average Daily Traffic: 35,582 (year 2008), Truck Traffic: 6%, Average Future Daily Traffic: 48,833 (year 2026), Design Load: H 15, Features Intersected: RAMP A; SR 8039 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 47.052, Lanes on structure: 4, Lanes under structure: 1, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 24.1m (79.1ft), Skew: 34 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 2, Length of Maximum Span: 26.2m (86.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 24.0m (78.7ft), Out-to-Out Width: 25.9m (85.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 73.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 43.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 5.33m (17.49ft), Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Bridge Improvement Cost: $18,000, Roadway Improvement Cost: $100,000, Total Project Cost: $238,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 40100800100101, Location: LUZERNE BORO JCT SR 1013 (Lat: 41.284694, Lng: -75.898867), Route carried "on" structure: State highway , Year Built: 1989, Status: Open, Structure Length: 2.68m (8.79ft), Average Daily Traffic: 4,862 (year 2008), Truck Traffic: 5%, Average Future Daily Traffic: 9,079 (year 2026), Design Load: H 15, Features Intersected: TOBY CREEK, Facility Carried by Structure: SR 1008 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 3, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 4 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 2, Length of Maximum Span: 12.8m (42.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 1.7m (5.6ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 14.8m (48.6ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Poor, Inventory Rating: 53.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: September 2006, Underwater Inspection Date: September 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 40101300300156, Location: LUZERNE BO .1 M N TR 309 (Lat: 41.281111, Lng: -75.895556), Route carried "on" structure: State highway , Year Built: 1939, Status: Open, Structure Length: 4.79m (15.72ft), Average Daily Traffic: 10,472 (year 2008), Truck Traffic: 7%, Average Future Daily Traffic: 14,371 (year 2026), Design Load: H 15, Features Intersected: TOBYS CREEK, Facility Carried by Structure: SR 1013 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.710, Lanes on structure: 3, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 6 degrees, Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 23.2m (76.1ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 15.8m (51.8ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Poor, Channel: Poor, Operating Rating: 43.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 25.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Length Of Structure Improvement: 4.79m (15.72ft), Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: August 2006, Underwater Inspection Date: August 2006, Bridge Improvement Cost: $85,000, Roadway Improvement Cost: $249,000, Total Project Cost: $1,143,000 ( Estimate for 2006), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 401054001, Location: LUZERNE BORO @ EVANS ST (Lat: 41.280806, Lng: -75.895417), Route carried "on" structure: State highway , Year Built: 1939, Status: Open, Structure Length: 1.89m (6.20ft), Average Daily Traffic: 5,050 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 10,654 (year 2026), Design Load: H 15, Features Intersected: TOBY CREEK, Facility Carried by Structure: SR 1054 EVANS ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 7.0m (23.0ft), Material/Design: Concrete, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 9.1m (29.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 7.0m (23.0ft), Out-to-Out Width: 9.4m (30.8ft) Condition: Deck: Satisfactory, Superstructure: Fair, Substructure: Poor, Channel: Poor, Operating Rating: 40.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 24.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: High priority of replacement, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Length Of Structure Improvement: 1.89m (6.20ft), Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: October 2006, Underwater Inspection Date: October 2006, Bridge Improvement Cost: $24,000, Roadway Improvement Cost: $100,000, Total Project Cost: $324,000 ( Estimate for 2004), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 40741802110001, Location: LUZ BORO E TR 309 LR40105 (Lat: 41.282083, Lng: -75.895667), Route carried "on" structure: City street , Year Built: 1980, Status: Open, Structure Length: 1.19m (3.90ft), Average Daily Traffic: 2,400 (year 2006), Truck Traffic: 2%, Average Future Daily Traffic: 3,200 (year 2026), Design Load: H 15, Features Intersected: TOBY CREEK, Facility Carried by Structure: BUCKINGHAM STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: Town or Township Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 11.6m (38.1ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 9.4m (30.8ft), Out-to-Out Width: 13.3m (43.6ft) Condition: Deck: Good, Superstructure: Good, Substructure: Satisfactory, Channel: Fair, Inventory Rating: 71.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Length Of Structure Improvement: 1.19m (3.90ft), Designated Inspection Frequency: Every 24 months, Other Special Inspection Frequency: Every 24 months, Inspection Date: April 2008, Other Special Inspection Date: April 2004, Bridge Improvement Cost: $3,000, Roadway Improvement Cost: $7,000, Total Project Cost: $35,000, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4003090644, Location: LUZ BORO OVER VAUGHN ST (Lat: 41.278222, Lng: -75.889719), Route carried "under" structure: City street , Year Built: 1980, Structure Length: 6.04m (19.82ft), Average Daily Traffic: 100 (year 2004), Truck Traffic: 10%, Features Intersected: VAUGHN ST, ABANDONED RR, Facility Carried by Structure: SR 0309 NB AND SB Minimum Vertical Clearance: 6.81m (22.34ft), Kilometerpoint: 0.000, Lanes on structure: 6, Lanes under structure: 2, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.4m (89.9ft) Find on map >>
Structure Number: 40030906441239, Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279722, Lng: -75.894722), Route carried "under" structure: State highway , Year Built: 1980, Structure Length: 15.76m (51.71ft), Average Daily Traffic: 5,236 (year 2008), Truck Traffic: 7%, Features Intersected: SR 1013 UNION STREET, Facility Carried by Structure: SR 0309 TR 309 Minimum Vertical Clearance: 4.72m (15.49ft), Kilometerpoint: 0.468, Lanes on structure: 4, Lanes under structure: 3, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.6m (107.0ft) Find on map >>
Structure Number: 40030906441239, Location: LUZERNE BORO OVER SR 1013 (Lat: 41.279722, Lng: -75.894722), Route carried "under" structure: State highway , Year Built: 1980, Structure Length: 15.76m (51.71ft), Average Daily Traffic: 115 (year 2008), Truck Traffic: 50%, Features Intersected: SR 1013 UNION STREET, Facility Carried by Structure: SR 0309 TR 309 Minimum Vertical Clearance: 4.85m (15.91ft), Kilometerpoint: 0.468, Lanes on structure: 4, Lanes under structure: 3, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.6m (107.0ft) Find on map >>
Structure Number: 4003090654, Location: LUZERNE BORO OVER SR 8039 (Lat: 41.287167, Lng: -75.904231), Route carried "under" structure: Ramp State highway , Year Built: 1980, Structure Length: 5.33m (17.49ft), Average Daily Traffic: 133 (year 2008), Truck Traffic: 7%, Features Intersected: RAMP A; SR 8039, Facility Carried by Structure: SR 0309 TR 309 Minimum Vertical Clearance: 4.72m (15.49ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 1, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 26.2m (86.0ft) Discuss this city on our hugely popular Pennsylvania forum Back to: Luzerne, PA, Pennsylvania, All US cities.
|
![]() |