National Bridge Inventory (NBI) Statistics
Number of bridges: 17
Total length: 150 meters (492ft)
Total costs: $2,720,000
Total average daily traffic: 231,115
Total average daily truck traffic: 39,104
National Bridge Inventory (NBI) Registered Bridges for Menomonie

New bridges - Historical Statistics

  • 1940-1949: 1
  • 1950-1959: 8
  • 1960-1969: 0
  • 1970-1979: 1
  • 1980-1989: 0
  • 1990-1999: 6
  • 2000-2009: 1

Reconstructed bridges - Historical Statistics

  • 1980-1989: 3
  • 1990-1999: 2

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Find on map >>

Structure Number: B170005,  Location: 0.1M E JCT CTH P (Lat: 44.875292,  Lng: -91.936872),  Route carried "on" structure: State highway 29,  Year Built: 1953,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 10.67m (35.01ft),  Average Daily Traffic: 5,558 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 8,920 (year 2023),  Design Load: H 15,  Features Intersected: RED CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.1m (95.5ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B170029,  Location: 0.4M N JCT USH 12 TO W (Lat: 44.906803,  Lng: -91.932631),  Route carried "on" structure: State highway 25,  Year Built: 1996,  Status: Open,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 11,491 (year 2005),  Truck Traffic: 3%,  Average Future Daily Traffic: 15,110 (year 2023),  Design Load: HS 20,  Features Intersected: IH 94
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.0m (105.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.98m (22.90ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Bridge Improvement Cost: $1,112,000,  Roadway Improvement Cost: $111,000,  Total Project Cost: $1,669,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B170032,  Location: 2.2M W JCT CTH B TO N (Lat: 44.908047,  Lng: -91.896453),  Route carried "on" structure: Interstate 94,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 14.31m (46.95ft),  Average Daily Traffic: 16,800 (year 2007),  Truck Traffic: 26%,  Average Future Daily Traffic: 31,900 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel continuous,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 56.7m (186.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2006,  Critical Feature Inspection Date: August 2007,  Underwater Inspection Date: October 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B170033,  Location: 1.6M E JCT STH 25 TO N (Lat: 44.907750,  Lng: -91.898306),  Route carried "on" structure: Interstate 94,  Year Built: 1957,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 14.31m (46.95ft),  Average Daily Traffic: 19,200 (year 2007),  Truck Traffic: 37%,  Average Future Daily Traffic: 31,900 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: RED CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel continuous,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 56.7m (186.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2006,  Critical Feature Inspection Date: July 2007,  Underwater Inspection Date: October 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B17004,  Location: 1.2M S JCT STH 25 (Lat: 44.907000,  Lng: -91.924667),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Posted for load,  Structure Length: 6.42m (21.06ft),  Average Daily Traffic: 2,600 (year 2005),  Average Future Daily Traffic: 2,600 (year 2025),  Design Load: H 20,  Features Intersected: IH 94,  Facility Carried by Structure: LRD WILSON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.7m (61.4ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: B170041,  Location: 0.3M N JCT CTH MMM (Lat: 44.905314,  Lng: -91.879814),  Route carried "on" structure: City street ,  Year Built: 1958,  Year Reconstructed: 1993,  Status: Posted for load,  Structure Length: 6.14m (20.14ft),  Average Daily Traffic: 400 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 550 (year 2025),  Design Load: HS 20,  Features Intersected: IH 94,  Facility Carried by Structure: LRD PARKWAY DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.3m (63.3ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Length Of Structure Improvement: 6.58m (21.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Bridge Improvement Cost: $701,000,  Roadway Improvement Cost: $70,000,  Total Project Cost: $1,051,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B170079,  Location: 0.1M S JCT USH 12,  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 470 (year 2005),  Average Future Daily Traffic: 470 (year 2025),  Design Load: HS 20,  Features Intersected: WILSON CREEK,  Facility Carried by Structure: LRD MEADOW HILL DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Structure Number: B170086,  Location: 0.2M S JCT STH 29,  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 1,000 (year 2005),  Average Future Daily Traffic: 1,000 (year 2025),  Design Load: HS 20,  Features Intersected: GILBERT CREEK,  Facility Carried by Structure: LRD 890TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B170104,  Location: 0.4M W JCT USH 12,  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 890 (year 2005),  Average Future Daily Traffic: 1,200 (year 2025),  Design Load: HS 20,  Features Intersected: WILSON CREEK,  Facility Carried by Structure: LRD HELLER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B17013,  Location: 0.6M W JCT STH 25 (H) (Lat: 44.883114,  Lng: -91.928722),  Route carried "on" structure: US 12,  Year Built: 1992,  Status: Open,  Structure Length: 25.12m (82.41ft),  Average Daily Traffic: 18,380 (year 2005),  Truck Traffic: 10%,  Average Future Daily Traffic: 24,050 (year 2025),  Design Load: HS 20,  Features Intersected: RED CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 54.3m (178.1ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 77.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2006,  Underwater Inspection Date: November 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Structure Number: B170164,  Location: 0.2M E JCT STH 25,  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 1.42m (4.66ft),  Average Daily Traffic: 200 (year 2004),  Truck Traffic: 12%,  Average Future Daily Traffic: 250 (year 2024),  Design Load: HS 20,  Features Intersected: BR RED CEDAR RIVER,  Facility Carried by Structure: LRD E 3RD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: B170638,  Location: 1.1M E JCT STH 25 (Lat: 44.885369,  Lng: -91.928411),  Route carried "on" structure: US 12,  Year Built: 1941,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 25.26m (82.87ft),  Average Daily Traffic: 24,513 (year 2005),  Truck Traffic: 3%,  Average Future Daily Traffic: 30,120 (year 2023),  Design Load: H 15,  Features Intersected: RED CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 56.4m (185.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2007,  Underwater Inspection Date: November 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B170029,  Location: 9.4M E JCT CTH Q TO N (Lat: 44.906803,  Lng: -91.932631),  Route carried "under" structure: Interstate 94,  Year Built: 1996,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 30,100 (year 2005),  Truck Traffic: 14%,  Features Intersected: IH 94,  Facility Carried by Structure: STH 25-BROADWAY ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>

Structure Number: B17004,  Location: 0.3M E JCT STH 25 TO N (Lat: 44.907000,  Lng: -91.924667),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 6.42m (21.06ft),  Average Daily Traffic: 25,000 (year 2005),  Truck Traffic: 26%,  Features Intersected: IH 94,  Facility Carried by Structure: LRD WILSON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.7m (61.4ft)

Find on map >>

Structure Number: B170041,  Location: 2.5M E JCT STH 25 TO N (Lat: 44.905314,  Lng: -91.879814),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 6.14m (20.14ft),  Average Daily Traffic: 25,000 (year 2005),  Truck Traffic: 26%,  Features Intersected: IH 94,  Facility Carried by Structure: LRD PARKWAY DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.3m (63.3ft)

Find on map >>

Structure Number: B170056,  Location: 0.1M E JCT STH 25 TO N (Lat: 44.906667,  Lng: -91.936667),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 25,000 (year 2005),  Truck Traffic: 26%,  Features Intersected: IH 94,  Facility Carried by Structure: CNW RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>

Structure Number: B170128,  Location: 1.2M E JCT STH 25 (H) (Lat: 44.880672,  Lng: -91.929603),  Route carried "under" structure: US 12,  Year Built: 1992,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 24,513 (year 2005),  Truck Traffic: 3%,  Features Intersected: USH 12-STH 25-BRDWY ST,  Facility Carried by Structure: PEDESTRIAN OVERPAS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 15.5m (50.9ft)