Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Millvale, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 34Number of bridges
  • 154ft / 47.2mTotal length
  • $2,316,000Total costs
  • 303,091Total average daily traffic
  • 24,493Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Millvale
  • No street view available for this location

New bridges in Millvale, PA - historical statistics
  • New bridges - historical statistics
  • 91910-1919
  • 21930-1939
  • 11940-1949
  • 151960-1969
  • 11970-1979
  • 31980-1989
  • 21990-1999
  • 12000-2009
Reconstructed bridges in Millvale, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21950-1959
  • 01960-1969
  • 01970-1979
  • 41980-1989
  • 21990-1999
  • 72000-2009
Average Bridge Daily Traffic in Millvale, PA
Average Bridge Truck Traffic in Millvale, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 4.2%Very good
  • 29.2%Good
  • 33.3%Satisfactory
  • 20.8%Fair
  • 12.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.8%Very good
  • 46.2%Good
  • 19.2%Satisfactory
  • 11.5%Fair
  • 19.2%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 38.5%Good
  • 19.2%Satisfactory
  • 34.6%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 35.0%Good
  • 25.0%Satisfactory
  • 15.0%Fair
Find on map >>   Show street view

Structure Number: 192,  Location: 2 MI SE NEW CHESTER (Lat: 39.882244,  Lng: -77.069878),  Route carried "on" structure: State highway ,  Year Built: 1940,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 2,056 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,901 (year 2032),  Design Load: H 20,  Features Intersected: LITTLE CONEWAGO CREEK,  Facility Carried by Structure: SR 1015
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.710,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.30m (14.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $116,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 58,  Location: SR 28 N.B. OVER BRIDGE ST (Lat: 40.483333,  Lng: -79.975000),  Route carried "on" structure: State highway 28,  Year Built: 1962,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 26,192 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 35,593 (year 2032),  Design Load: HS 20,  Features Intersected: BRIDGE ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.075,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.7m (41.7ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 91.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 582,  Location: SR 28 N.B. OVER RAMP B (Lat: 40.478086,  Lng: -79.967953),  Route carried "on" structure: State highway 28,  Year Built: 1963,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 33,877 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 32,202 (year 2032),  Design Load: HS 20,  Features Intersected: RAMP B
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.075,  Lanes on structure: 2,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 583,  Location: 70 S.B.O/RP.B & BRIDGE ST (Lat: 40.477244,  Lng: -79.968978),  Route carried "on" structure: State highway 28,  Year Built: 1963,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 8.38m (27.49ft),  Average Daily Traffic: 25,375 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 34,484 (year 2032),  Design Load: HS 20,  Features Intersected: (4009) RP B & BRIDGE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.067,  Lanes on structure: 2,  Lanes under structure: 15,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.40m (27.56ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $15,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $197,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 584,  Location: MILLVALE OVER RAMP A (Lat: 40.478586,  Lng: -79.967269),  Route carried "on" structure: State highway 28,  Year Built: 1963,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 59,252 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 66,686 (year 2032),  Design Load: HS 20,  Features Intersected: SR 8046 RAMP A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.075,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.4m (76.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Inventory Rating: 60.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.80m (5.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 192,  Location: MILLVALE @ 28 NB OFF RAMP (Lat: 40.480808,  Lng: -79.970794),  Route carried "on" structure: State highway ,  Year Built: 1960,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 8,864 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,258 (year 2032),  Design Load: H 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: EVERGREEN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.642,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $11,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $153,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1921,  Location: 1044' S.W. OF SR 4004 (Lat: 40.488081,  Lng: -79.972600),  Route carried "on" structure: State highway ,  Year Built: 1982,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 9,909 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,690 (year 2032),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: EVERGREEN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.458,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1922,  Location: 200' SOUTH OF SR 4004 (Lat: 40.490047,  Lng: -79.971833),  Route carried "on" structure: State highway ,  Year Built: 1982,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 9,909 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,690 (year 2032),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: EVERGREEN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.208,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Bridge Improvement Cost: $5,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $71,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1923,  Location: AT INT NORTH AVE MILLVALE (Lat: 40.493203,  Lng: -79.975069),  Route carried "on" structure: State highway ,  Year Built: 1932,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 10,144 (year 2022),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,827 (year 2032),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: EVERGREEN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.208,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 3.5m (11.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $98,000,  Total Project Cost: $449,000
Find on map >>   Show street view

Structure Number: 2615,  Location: 445001 AT BABCOCK BLVD (Lat: 40.493000,  Lng: -79.975097),  Route carried "on" structure: Business City street ,  Year Built: 1931,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 2,500 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,500 (year 2025),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: NORTH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $2,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $47,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2616,  Location: 445002 AT FRANKLIN ST (Lat: 40.490436,  Lng: -79.972378),  Route carried "on" structure: Business City street ,  Year Built: 1982,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,500 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,500 (year 2025),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: NORTH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 68.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $30,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2617,  Location: 445003 AT FREDERICK ST (Lat: 40.488039,  Lng: -79.973269),  Route carried "on" structure: Business City street ,  Year Built: 1911,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 2,500 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,500 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: NORTH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.5m (11.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.20m (3.94ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2618,  Location: NORTH AVE AT KLOPFER ST (Lat: 40.485661,  Lng: -79.973117),  Route carried "on" structure: Business City street ,  Year Built: 2006,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 4,500 (year 2010),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,950 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: NORTH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 6 degrees,  Material/Design: Steel,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.5m (54.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 27.0m (88.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Critical Feature Inspection Date: April 2020,  Bridge Improvement Cost: $26,000,  Roadway Improvement Cost: $77,000,  Total Project Cost: $351,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2619,  Location: 40' East of North Ave (Lat: 40.485250,  Lng: -79.972917),  Route carried "on" structure: Business City street ,  Year Built: 1915,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 1,000 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,000 (year 2025),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: KLOPFER ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2020,  Other Special Inspection Date: April 2021,  Bridge Improvement Cost: $8,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $113,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 262,  Location: FREMONT 25' FROM NORTH AV (Lat: 40.481472,  Lng: -79.973667),  Route carried "on" structure: Business City street ,  Year Built: 1911,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 50 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 50 (year 2026),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: FREMONT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 8.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 4.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Other Special Inspection Date: April 2021,  Bridge Improvement Cost: $13,000,  Roadway Improvement Cost: $38,000,  Total Project Cost: $174,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2621,  Location: 445007 AT NORTH AVE (Lat: 40.481511,  Lng: -79.973992),  Route carried "on" structure: Business City street ,  Year Built: 1911,  Year Reconstructed: 1950,  Status: Posted for load,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 4,500 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,500 (year 2026),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: LINCOLN AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 33.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Other Special Inspection Date: April 2021,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $31,000,  Total Project Cost: $123,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 2622,  Location: Int Grant Ave, North Ave (Lat: 40.480750,  Lng: -79.974667),  Route carried "on" structure: Business City street ,  Year Built: 1914,  Year Reconstructed: 1986,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 4,500 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,500 (year 2026),  Design Load: HS 20,  Features Intersected: Girty's Run,  Facility Carried by Structure: Grant Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Other Special Inspection Date: April 2021,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $117,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2623,  Location: SW of Grant St. (Lat: 40.479417,  Lng: -79.974889),  Route carried "on" structure: City street ,  Year Built: 1911,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 200 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: SEDGWICK ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 4.3m (14.1ft),  Out-to-Out Width: 4.6m (15.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $20,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2624,  Location: 445010 SHERMAN STREET (Lat: 40.478583,  Lng: -79.972694),  Route carried "on" structure: Business City street ,  Year Built: 1911,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 500 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 550 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: SHERMAN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 84.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.80m (2.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2626,  Location: Int. Grant Ave, E Ohio St (Lat: 40.477942,  Lng: -79.969500),  Route carried "on" structure: Business City street ,  Year Built: 1914,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 4,500 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,950 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: Girty's Run,  Facility Carried by Structure: Grant Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 9.9m (32.5ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 69.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $8,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $105,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2627,  Location: NEAR INT. W/ EAST OHIO (Lat: 40.478611,  Lng: -79.968750),  Route carried "on" structure: Business City street ,  Year Built: 1915,  Year Reconstructed: 1963,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 4,000 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,000 (year 2025),  Design Load: HS 20,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: LINCOLN AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Poor,  Channel: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.90m (2.95ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Bridge Improvement Cost: $8,000,  Roadway Improvement Cost: $26,000,  Total Project Cost: $113,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2839,  Location: MILLVALE, 28 INTERCHNGE (Lat: 40.470000,  Lng: -79.966667),  Route carried "on" structure: Ramp State highway ,  Year Built: 1963,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 2,266 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,063 (year 2032),  Design Load: HS 20,  Features Intersected: RAMP B SR 8046,  Facility Carried by Structure: RAMP A
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.40m (7.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Bridge Improvement Cost: $10,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $137,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 4002,  Location: 0.05 MILE S. FROM PA 36 (Lat: 40.160789,  Lng: -78.374547),  Route carried "on" structure: State highway ,  Year Built: 1997,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 569 (year 2022),  Truck Traffic: 11%,  Average Future Daily Traffic: 948 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: YELLOW CREEK RELIEF CHAN,  Facility Carried by Structure: SR 1005(OLD PA 36)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.298,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.0m (105.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.10m (13.45ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 403,  Location: OVER SR 2035 AT EXIT 149 (Lat: 39.990000,  Lng: -78.240000),  Route carried "on" structure: Interstate 70,  Year Built: 1963,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 7,400 (year 2020),  Truck Traffic: 42%,  Average Future Daily Traffic: 9,738 (year 2032),  Design Load: HS 20,  Features Intersected: SR 2035
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.614,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.60m (5.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4071,  Location: OVER SR 4009 (CESSNA) (Lat: 40.110192,  Lng: -78.526244),  Route carried "on" structure: Interstate 99,  Year Built: 1978,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 5.52m (18.11ft),  Average Daily Traffic: 6,722 (year 2021),  Truck Traffic: 19%,  Average Future Daily Traffic: 7,297 (year 2032),  Design Load: HS 20,  Features Intersected: SR 4009
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.626,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 15 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.5m (86.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 24.41m (80.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4002,  Location: 445011 SHERIDAN STREET (Lat: 40.478322,  Lng: -79.971350),  Route carried "on" structure: Business City street ,  Year Built: 1998,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 500 (year 2006),  Truck Traffic: 15%,  Average Future Daily Traffic: 550 (year 2026),  Design Load: HS 25 or greater,  Features Intersected: GIRTYS RUN,  Facility Carried by Structure: SHERIDAN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42123,  Location: RT28&4009MILLVALE (Lat: 40.478333,  Lng: -79.975000),  Route carried "on" structure: State highway 28,  Year Built: 1960,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 33,877 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 32,202 (year 2032),  Design Load: HS 20,  Features Intersected: RAMPB/AND/02400900201211
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.075,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 58,  Location: SR 28 N.B. OVER BRIDGE ST (Lat: 40.483333,  Lng: -79.975000),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 100 (year 2004),  Truck Traffic: 1%,  Features Intersected: BRIDGE ST.,  Facility Carried by Structure: SR 28 NB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 582,  Location: SR 28 N.B. OVER RAMP B (Lat: 40.478086,  Lng: -79.967953),  Route carried "under" structure: Ramp State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 6,748 (year 2022),  Truck Traffic: 7%,  Features Intersected: RAMP B,  Facility Carried by Structure: SR 0028 SB
Minimum Vertical Clearance: 6.63m (21.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 9.1m (29.9ft)

Find on map >>   Show street view

Structure Number: 583,  Location: 70 S.B.O/RP.B & BRIDGE ST (Lat: 40.477244,  Lng: -79.968978),  Route carried "under" structure: State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 5,718 (year 2022),  Truck Traffic: 3%,  Features Intersected: (4009) RP B & BRIDGE ST,  Facility Carried by Structure: SR 0028 SB
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 583,  Location: 70 S.B.O/RP.B & BRIDGE ST (Lat: 40.477244,  Lng: -79.968978),  Route carried "under" structure: Ramp State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 6,748 (year 2022),  Truck Traffic: 7%,  Features Intersected: (4009) RP B & BRIDGE ST,  Facility Carried by Structure: SR 0028 SB
Minimum Vertical Clearance: 5.61m (18.41ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 583,  Location: 70 S.B.O/RP.B & BRIDGE ST (Lat: 40.477244,  Lng: -79.968978),  Route carried "under" structure: State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 6,601 (year 2022),  Truck Traffic: 4%,  Features Intersected: (4009) RP B & BRIDGE ST,  Facility Carried by Structure: SR 0028 SB
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 584,  Location: MILLVALE OVER RAMP A (Lat: 40.478586,  Lng: -79.967269),  Route carried "under" structure: Ramp State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 2,266 (year 2022),  Truck Traffic: 7%,  Features Intersected: SR 8046 RAMP A,  Facility Carried by Structure: SR 28 NB-SB
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.1m (56.1ft)

Find on map >>   Show street view

Structure Number: 2839,  Location: MILLVALE, 28 INTERCHNGE (Lat: 40.470000,  Lng: -79.966667),  Route carried "under" structure: Ramp State highway ,  Year Built: 1963,  Structure Length: 0. m,  Average Daily Traffic: 6,748 (year 2022),  Truck Traffic: 7%,  Features Intersected: RAMP B SR 8046,  Facility Carried by Structure: RAMP A
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Length of Maximum Span: 15.5m (50.9ft)

Discuss Millvale, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.