![]() |
Bridge Statistics for Moberly, Missouri (MO) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Moberly, MO, Missouri, Missouri forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 14 Total length: 130 meters (427ft) Total average daily traffic: 111,100 Total average daily truck traffic: 16,236 National Bridge Inventory (NBI) Registered Bridges for Moberly
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Channel Find on map >>
Structure Number: 11764, Location: S 31 T 54 N R 13 W (Lat: 39.433333, Lng: -92.416667), Route carried "on" structure: City street , Year Built: 1998, Status: Open, Structure Length: 11.09m (36.38ft), Average Daily Traffic: 4,780 (year 2006), Truck Traffic: 10%, Average Future Daily Traffic: 5,975 (year 2027), Design Load: HS 20, Features Intersected: US 63, OR 63, Facility Carried by Structure: SINNOCK AVE E Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.028, Lanes on structure: 2, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Skew: 2 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 45.2m (148.3ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 8.2m (26.9ft), Out-to-Out Width: 9.0m (29.5ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Operating Rating: 32.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 20.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: High priority of corrective action, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 11792, Location: S 31 T 54 N R 13 W (Lat: 39.445000, Lng: -92.423333), Route carried "on" structure: US 63, Year Built: 1998, Status: Open, Structure Length: 6.77m (22.21ft), Average Daily Traffic: 6,406 (year 2006), Truck Traffic: 17%, Average Future Daily Traffic: 11,210 (year 2027), Design Load: HS 25, Features Intersected: US 24 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 408.884, Lanes on structure: 3, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 14.0m (45.9ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 25.9m (85.0ft), Curb-To-Curb Width: 14.0m (45.9ft), Out-to-Out Width: 14.8m (48.6ft) Condition: Deck: Very good, Superstructure: Excellent, Substructure: Excellent, Inventory Rating: 58.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 11793, Location: S 25 T 54 N R 14 W (Lat: 39.440000, Lng: -92.423333), Route carried "on" structure: US 63, Year Built: 1998, Status: Open, Structure Length: 6.77m (22.21ft), Average Daily Traffic: 3,808 (year 2006), Truck Traffic: 12%, Average Future Daily Traffic: 6,664 (year 2027), Design Load: HS 25, Features Intersected: US 24 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 133.920, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.6m (38.1ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 25.9m (85.0ft), Curb-To-Curb Width: 11.6m (38.1ft), Out-to-Out Width: 12.4m (40.7ft) Condition: Deck: Very good, Superstructure: Excellent, Substructure: Excellent, Inventory Rating: 58.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 118, Location: S 6 T 53 N R 13 W (Lat: 39.420000, Lng: -92.411667), Route carried "on" structure: State highway 63, Year Built: 1998, Status: Open, Structure Length: 13.29m (43.60ft), Average Daily Traffic: 11,000 (year 2006), Truck Traffic: 10%, Average Future Daily Traffic: 13,750 (year 2027), Design Load: HS 20, Features Intersected: BNSF RR, COON CR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.989, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 1 degrees, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 7, Length of Maximum Span: 21.3m (69.9ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 11.8m (38.7ft), Out-to-Out Width: 12.6m (41.3ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Very good, Operating Rating: 78.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 47.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 11802, Location: S 6 T 53 N R 13 W (Lat: 39.416667, Lng: -92.413333), Route carried "on" structure: State highway EE, Year Built: 1999, Status: Open, Structure Length: 11.19m (36.71ft), Average Daily Traffic: 3,253 (year 2006), Truck Traffic: 10%, Average Future Daily Traffic: 4,228 (year 2027), Design Load: HS 20, Features Intersected: US 63 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.957, Lanes on structure: 4, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 15.8m (51.8ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 47.0m (154.2ft), Curb-To-Curb Width: 20.7m (67.9ft), Out-to-Out Width: 21.5m (70.5ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Excellent, Operating Rating: 62.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 36.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 11929, Location: S 6 T 53 N R 13 W (Lat: 39.420000, Lng: -92.413333), Route carried "on" structure: US 63, Year Built: 1991, Year Reconstructed: 1999, Status: Open, Structure Length: 8.38m (27.49ft), Average Daily Traffic: 6,406 (year 2006), Truck Traffic: 17%, Average Future Daily Traffic: 11,210 (year 2027), Design Load: HS 20, Features Intersected: NS RR, COON CR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 405.967, Lanes on structure: 3, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 14.3m (46.9ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 22.4m (73.5ft), Curb-To-Curb Width: 14.4m (47.2ft), Out-to-Out Width: 15.3m (50.2ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Excellent, Channel: Very good, Operating Rating: 74.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 31.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 11948, Location: S 6 T 53 N R 13 W (Lat: 39.423333, Lng: -92.410000), Route carried "on" structure: US 63, Year Built: 2000, Status: Open, Structure Length: 8.38m (27.49ft), Average Daily Traffic: 6,795 (year 2006), Truck Traffic: 12%, Average Future Daily Traffic: 11,891 (year 2027), Design Load: HS 25, Features Intersected: NS RR, COON CR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 136.811, Lanes on structure: 3, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 14.0m (45.9ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 22.4m (73.5ft), Curb-To-Curb Width: 14.0m (45.9ft), Out-to-Out Width: 14.8m (48.6ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Excellent, Operating Rating: 93.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 50.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Meets minimum limits, Underclear: Equal to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 3719, Location: S 25 T 54 N R 14 W (Lat: 39.440000, Lng: -92.436667), Route carried "on" structure: US 24, Year Built: 1988, Status: Open, Structure Length: 6.07m (19.91ft), Average Daily Traffic: 12,572 (year 2006), Truck Traffic: 19%, Average Future Daily Traffic: 22,001 (year 2027), Design Load: HS 20+Mod, Features Intersected: NS RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 217.756, Lanes on structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 19.5m (64.0ft), Skew: 1 degrees, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 20.3m (66.6ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 19.1m (62.7ft), Out-to-Out Width: 20.0m (65.6ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Excellent, Operating Rating: 72.0 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 38.0 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 11764, Location: S 31 T 54 N R 13 W (Lat: 39.433333, Lng: -92.416667), Route carried "under" structure: US 63, Year Built: 1998, Structure Length: 11.09m (36.38ft), Average Daily Traffic: 6,795 (year 2006), Truck Traffic: 12%, Features Intersected: US 63, Facility Carried by Structure: SINNOCK AVE E Minimum Vertical Clearance: 5.23m (17.16ft), Kilometerpoint: 135.575, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.2m (148.3ft) Find on map >>
Structure Number: 11764, Location: S 31 T 54 N R 13 W (Lat: 39.433333, Lng: -92.416667), Route carried "under" structure: US 63, Year Built: 1998, Structure Length: 11.09m (36.38ft), Average Daily Traffic: 6,406 (year 2006), Truck Traffic: 17%, Features Intersected: US 63, Facility Carried by Structure: SINNOCK AVE E Minimum Vertical Clearance: 5.21m (17.09ft), Kilometerpoint: 407.281, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 45.2m (148.3ft) Find on map >>
Structure Number: 11792, Location: S 31 T 54 N R 13 W (Lat: 39.445000, Lng: -92.423333), Route carried "under" structure: US 24, Year Built: 1998, Structure Length: 6.77m (22.21ft), Average Daily Traffic: 13,568 (year 2006), Truck Traffic: 12%, Features Intersected: US 24, Facility Carried by Structure: US 63 N Minimum Vertical Clearance: 5.23m (17.16ft), Kilometerpoint: 218.821, Lanes on structure: 3, Lanes under structure: 2, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.9m (85.0ft) Find on map >>
Structure Number: 11793, Location: S 25 T 54 N R 14 W (Lat: 39.440000, Lng: -92.423333), Route carried "under" structure: US 24, Year Built: 1998, Structure Length: 6.77m (22.21ft), Average Daily Traffic: 16,110 (year 2006), Truck Traffic: 19%, Features Intersected: US 24, Facility Carried by Structure: US 63 S Minimum Vertical Clearance: 5.23m (17.16ft), Kilometerpoint: 218.792, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 25.9m (85.0ft) Find on map >>
Structure Number: 11802, Location: S 6 T 53 N R 13 W (Lat: 39.416667, Lng: -92.413333), Route carried "under" structure: US 63, Year Built: 1999, Structure Length: 11.19m (36.71ft), Average Daily Traffic: 6,406 (year 2006), Truck Traffic: 17%, Features Intersected: US 63, Facility Carried by Structure: RT EE E Minimum Vertical Clearance: 5.13m (16.83ft), Kilometerpoint: 405.641, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 47.0m (154.2ft) Find on map >>
Structure Number: 11802, Location: S 6 T 53 N R 13 W (Lat: 39.416667, Lng: -92.413333), Route carried "under" structure: US 63, Year Built: 1999, Structure Length: 11.19m (36.71ft), Average Daily Traffic: 6,795 (year 2006), Truck Traffic: 12%, Features Intersected: US 63, Facility Carried by Structure: RT EE E Minimum Vertical Clearance: 5.18m (16.99ft), Kilometerpoint: 137.224, Lanes on structure: 4, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 47.0m (154.2ft) Discuss this city on our hugely popular Missouri forum Back to: Moberly, MO, Missouri, All US cities.
|
![]() |