Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Nome, Alaska (AK)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 256ft / 77.8mTotal length
  • $417,000Total costs
  • 3,433Total average daily traffic
  • 285Total average daily truck traffic
  • 4,950Total future (year 2035) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for Nome
  • No street view available for this location

New bridges in Nome, AK - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 21950-1959
  • 31960-1969
  • 11970-1979
  • 41980-1989
  • 11990-1999
  • 22000-2009
Reconstructed bridges in Nome, AK - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
Average Bridge Truck Traffic in Nome, AK
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.1%Very good
  • 46.2%Good
  • 30.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 23.1%Very good
  • 38.5%Good
  • 7.7%Satisfactory
  • 30.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 30.8%Good
  • 38.5%Satisfactory
  • 23.1%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 7.1%Excellent
  • 50.0%Very good
  • 14.3%Good
  • 7.1%Satisfactory
  • 21.4%Fair
Find on map >>   Show street view

Structure Number: 266,  Location: MILE POINT 19.4 (Lat: 64.677706,  Lng: -165.746242),  Route carried "on" structure: State highway 131,  Year Built: 1962,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 3.57m (11.71ft),  Average Daily Traffic: 20 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 30 (year 2039),  Design Load: HS 20,  Features Intersected: CRIPPLE RIVER,  Facility Carried by Structure: IRR:NOME-TELLER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.221,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Very good,  Operating Rating: 63.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 268,  Location: MILE POINT 66.0 (Lat: 64.818211,  Lng: -163.723206),  Route carried "on" structure: State highway 130,  Year Built: 1982,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 160 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 490 (year 2039),  Design Load: HS 20,  Features Intersected: FOX RIVER,  Facility Carried by Structure: IRR:NOME-COUNCIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 106.194,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 65.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 269,  Location: MILE POINT 69.5 (Lat: 64.864700,  Lng: -163.692883),  Route carried "on" structure: State highway 130,  Year Built: 1982,  Status: Open,  Structure Length: 1.85m (6.07ft),  Average Daily Traffic: 160 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 490 (year 2039),  Design Load: HS 20,  Features Intersected: BEAR RIVER,  Facility Carried by Structure: IRR:NOME-COUNCIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 111.826,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 301,  Location: MILE POINT 6.6 (Lat: 55.549100,  Lng: -133.097100),  Route carried "on" structure: State highway 924,  Year Built: 1990,  Status: Open,  Structure Length: 9.78m (32.09ft),  Average Daily Traffic: 1,990 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,250 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: KLAWOCK RIVER,  Facility Carried by Structure: IRR:CRAIG/KLWK HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.552,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 87.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 319,  Location: MILE POINT 36.1 (Lat: 64.903331,  Lng: -165.102161),  Route carried "on" structure: State highway 64,  Year Built: 1982,  Status: Posted for load,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 249 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: GRAND CENTRAL RIVER,  Facility Carried by Structure: IRR:NOME-TAYLOR RD
Minimum Vertical Clearance: 3.55m (11.65ft),  Kilometerpoint: 58.097,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 323,  Location: MILE POINT 12.4 (Lat: 64.585661,  Lng: -165.666811),  Route carried "on" structure: State highway 131,  Year Built: 1959,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 20 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 30 (year 2039),  Design Load: HS 20,  Features Intersected: PENNY RIVER,  Facility Carried by Structure: IRR:NOME-TELLER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.920,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 93.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 324,  Location: MILE POINT 7.1 (Lat: 64.564314,  Lng: -165.511414),  Route carried "on" structure: State highway 131,  Year Built: 1959,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 20 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 30 (year 2039),  Design Load: HS 20,  Features Intersected: SNAKE RIVER,  Facility Carried by Structure: IRR:NOME-TELLER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.394,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Fair,  Operating Rating: 79.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 398,  Location: MILE POINT 67.9 (Lat: 65.216275,  Lng: -164.827903),  Route carried "on" structure: State highway 64,  Year Built: 1961,  Status: Posted for load,  Structure Length: 9.33m (30.61ft),  Average Daily Traffic: 50 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 90 (year 2035),  Design Load: H 15,  Features Intersected: KUZITRIN RIVER,  Facility Carried by Structure: IRR:NOME-TAYLOR RD
Minimum Vertical Clearance: 3.55m (11.65ft),  Kilometerpoint: 109.274,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 91.4m (299.9ft),  Curb-To-Curb Width: 5.2m (17.1ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 26.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 14.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 893,  Location: MILE POINT 85.4 (Lat: 65.433817,  Lng: -164.668178),  Route carried "on" structure: State highway NSP00,  Year Built: 1941,  Status: Posted for load,  Structure Length: 5.58m (18.31ft),  Average Daily Traffic: 50 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 60 (year 2035),  Design Load: HS 15,  Features Intersected: KOUGAROK RIVER,  Facility Carried by Structure: IRR:NOME-TAYLOR RD
Minimum Vertical Clearance: 3.55m (11.65ft),  Kilometerpoint: 137.438,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 55.5m (182.1ft),  Curb-To-Curb Width: 3.4m (11.2ft),  Out-to-Out Width: 4.0m (13.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 24.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 11.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: August 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 1127,  Location: MILE POINT 20.8 (Lat: 64.472081,  Lng: -164.746864),  Route carried "on" structure: State highway 130,  Year Built: 1978,  Status: Open,  Structure Length: 24.61m (80.74ft),  Average Daily Traffic: 160 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 490 (year 2039),  Design Load: HS 20,  Features Intersected: SAFETY SOUND ESTUARY,  Facility Carried by Structure: IRR:NOME-COUNCIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.500,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 78.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1564,  Location: MILE POINT 43.3 (Lat: 64.929714,  Lng: -164.873003),  Route carried "on" structure: State highway 64,  Year Built: 1983,  Status: Posted for load,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 249 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 300 (year 2035),  Design Load: HS 20,  Features Intersected: CRATER CREEK,  Facility Carried by Structure: IRR:NOME-TAYLOR RD
Minimum Vertical Clearance: 3.55m (11.65ft),  Kilometerpoint: 69.623,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.6m (97.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 214,  Location: MILE POINT 3.2 (Lat: 64.594819,  Lng: -165.436306),  Route carried "on" structure: State highway ,  Year Built: 2005,  Status: Open,  Structure Length: 3.12m (10.24ft),  Average Daily Traffic: 60 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 70 (year 2039),  Design Load: HL 93,  Features Intersected: GLACIER CREEK,  Facility Carried by Structure: GLACIER CR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.150,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Inventory Rating: 52.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4075,  Location: MILE POINT 4.8 (Lat: 64.551103,  Lng: -165.442347),  Route carried "on" structure: State highway ,  Year Built: 1967,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 170 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 210 (year 2039),  Design Load: H 20,  Features Intersected: ANVIL CREEK,  Facility Carried by Structure: IRR:NOME-TELLER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.678,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.1m (26.6ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020
Find on map >>   Show street view

Structure Number: CEPPOAAK0001002,  Location: NOME, ALASKA (Lat: 64.498736,  Lng: -165.436689),  Route carried "on" structure: ServiceOther road ,  Year Built: 2005,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 75 (year 2017),  Truck Traffic: 35%,  Average Future Daily Traffic: 110 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: NOME HARBOR,  Facility Carried by Structure: ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Corps of Engineers (Civil),  Approaching Roadway Width: 8.9m (29.2ft),  Navigation Control: Yes ( Vertical Clearance: 2.9m (9.5ft), Horizontal Clearance: 29.9m (98.1ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.9m (117.8ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 7.42m (24.34ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: June 2020,  Bridge Improvement Cost: $278,000,  Roadway Improvement Cost: $28,000,  Total Project Cost: $417,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels
Discuss Nome, Alaska (AK) on our hugely popular Alaska forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.