![]() |
Bridge Statistics for Oak Forest, Illinois (IL) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Oak Forest, IL, Illinois, Illinois forum, All US cities. National Bridge Inventory (NBI) Statistics
Number of bridges: 10
Total length: 30 meters (98ft) Total average daily traffic: 319,718 Total average daily truck traffic: 13,938 National Bridge Inventory (NBI) Registered Bridges for Oak Forest
No street view available for this location
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Bridge Condition - Culverts Find on map >> Show street view
Structure Number: 1604230413, Location: 0.1 M N US 6 (Lat: 41.603539, Lng: -87.736483), Route carried "on" structure: State highway 50, Year Built: 1934, Year Reconstructed: 1978, Status: Open, Structure Length: 0.98m (3.22ft), Average Daily Traffic: 29,800 (year 2011), Truck Traffic: 4%, Average Future Daily Traffic: 30,694 (year 2032), Features Intersected: MIDLOTHIAN CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 58.938, Lanes on structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 20.4m (66.9ft), Skew: 34 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.6m (15.1ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft) Condition: Channel: Fair, Culverts: Satisfactory, Operating Rating: 56.7 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 38.7 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 11, Deck Structure Type: Concrete Cast-file-Place Find on map >> Show street view
Structure Number: 16099726364, Location: .5 M S IL 83 (147TH) (Lat: 41.618189, Lng: -87.737031), Route carried "on" structure: State highway 50, Year Built: 1971, Status: Open, Structure Length: 0.73m (2.40ft), Average Daily Traffic: 29,800 (year 2011), Truck Traffic: 4%, Average Future Daily Traffic: 30,694 (year 2032), Design Load: HS 20, Features Intersected: CREEK N OF 151ST ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 60.563, Lanes on structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 18.3m (60.0ft), Skew: 20 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.4m (11.2ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.2m (3.9ft) Condition: Channel: Fair, Culverts: Good, Operating Rating: 65.7 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 36 months, Inspection Date: Febuary 12 Find on map >> Show street view
Structure Number: 16212526348, Location: 3 M SW I-294 (Lat: 41.587431, Lng: -87.727528), Route carried "on" structure: Spur Other road 350, Year Built: 1968, Status: Open, Structure Length: 9.75m (31.99ft), Average Daily Traffic: 29,000 (year 2010), Truck Traffic: 6%, Average Future Daily Traffic: 29,870 (year 2032), Design Load: HS 20, Features Intersected: I- 57, Facility Carried by Structure: 167TH ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.644, Lanes on structure: 4, Lanes under structure: 10, Base Highway Network: Yes (Inventory Route: 20350023, Subroute: 90), Owner: State Highway Agency, Approaching Roadway Width: 21.9m (71.9ft), Skew: 21 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Number Of Approach Spans: 2, Length of Maximum Span: 35.1m (115.2ft), Curb-To-Curb Width: 25.5m (83.7ft), Out-to-Out Width: 27.4m (89.9ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 72.0 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 46.8 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 11, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous, Membrane: Built-up Find on map >> Show street view
Structure Number: 16284336473, Location: 0.03 M W OF IL 50 (Lat: 41.603239, Lng: -87.737100), Route carried "on" structure: US 6, Year Built: 1925, Year Reconstructed: 1931, Status: Open, Structure Length: 0.87m (2.85ft), Average Daily Traffic: 34,400 (year 2009), Truck Traffic: 5%, Average Future Daily Traffic: 35,432 (year 2032), Features Intersected: MIDLOTHIAN CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 266.692, Lanes on structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 16.5m (54.1ft), Skew: 32 degrees, Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 1, Length of Maximum Span: 8.4m (27.6ft), Curb or Sidewalk Widths: Left: 2.1m (6.9ft), Right: 0.0m, Curb-To-Curb Width: 20.1m (65.9ft), Out-to-Out Width: 36.6m (120.1ft) Condition: Deck: Poor, Superstructure: Poor, Substructure: Satisfactory, Channel: Fair, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 19.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Meets minimum limits, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: April 11, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >> Show street view
Structure Number: 16284633773, Location: 1.7 MI W. ILL. 83 (Lat: 41.624619, Lng: -87.771214), Route carried "on" structure: Other road 1602, Year Built: 2007, Status: Open, Structure Length: 0.86m (2.82ft), Average Daily Traffic: 9,400 (year 2010), Truck Traffic: 3%, Average Future Daily Traffic: 9,682 (year 2032), Design Load: HS 20, Features Intersected: BACA RIO DITCH, Facility Carried by Structure: 147TH ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.915, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Material/Design: Concrete, Design/Construction: Culvert, Length of Maximum Span: 0.0m, Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 17.1m (56.1ft) Condition: Channel: Satisfactory, Culverts: Good, Operating Rating: 44.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 36 months, Inspection Date: Febuary 12 Find on map >> Show street view
Structure Number: 1676402771, Location: 0.1 M S 151ST (Lat: 41.617125, Lng: -87.738147), Route carried "on" structure: City street 1260, Year Built: 1967, Status: Open, Structure Length: 0.91m (2.99ft), Average Daily Traffic: 309 (year 1998), Average Future Daily Traffic: 318 (year 2032), Design Load: HS 20, Features Intersected: NATALIE CR, Facility Carried by Structure: LACROSSE AV Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.161, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Skew: 6 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.6m (15.1ft), Curb or Sidewalk Widths: Left: 1.7m (5.6ft), Right: 1.7m (5.6ft), Curb-To-Curb Width: 7.9m (25.9ft), Out-to-Out Width: 23.0m (75.5ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 44.1 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 48 months, Inspection Date: June 11, Deck Structure Type: Concrete Cast-file-Place Find on map >> Show street view
Structure Number: 16764127711, Location: 0.1 M S 151ST (Lat: 41.617133, Lng: -87.739975), Route carried "on" structure: City street 1230, Year Built: 1967, Status: Open, Structure Length: 0.85m (2.79ft), Average Daily Traffic: 309 (year 1998), Average Future Daily Traffic: 318 (year 2032), Design Load: HS 20, Features Intersected: NATALIE CR, Facility Carried by Structure: LAPORTE AV Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.161, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.9m (25.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.3m (14.1ft), Curb or Sidewalk Widths: Left: 1.4m (4.6ft), Right: 1.4m (4.6ft), Curb-To-Curb Width: 9.1m (29.9ft), Out-to-Out Width: 12.2m (40.0ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 44.1 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 48 months, Inspection Date: June 2009, Deck Structure Type: Concrete Cast-file-Place Find on map >> Show street view
Structure Number: 1603822309, Location: 0.2 M W ILL 50 P3 (Lat: 41.603203, Lng: -87.740275), Route carried "under" structure: US 6, Year Built: 1900, Structure Length: 3.20m (10.50ft), Average Daily Traffic: 34,400 (year 2009), Truck Traffic: 5%, Features Intersected: US 6 (159TH ST), Facility Carried by Structure: CRI&P RR Minimum Vertical Clearance: 4.55m (14.93ft), Kilometerpoint: 26.645, Lanes under structure: 4, Material/Design: Concrete, Length of Maximum Span: 15.8m (51.8ft) Find on map >> Show street view
Structure Number: 16042223124, Location: 0.2 M N US 6 P3 (Lat: 41.606033, Lng: -87.736581), Route carried "under" structure: State highway 50, Year Built: 1900, Structure Length: 2.26m (7.41ft), Average Daily Traffic: 29,800 (year 2011), Truck Traffic: 4%, Features Intersected: ILL 50 (CICERO AVE), Facility Carried by Structure: CRI&P RR Minimum Vertical Clearance: 0.45m (1.48ft), Kilometerpoint: 59.211, Lanes under structure: 4, Material/Design: Steel, Length of Maximum Span: 22.3m (73.2ft) Find on map >> Show street view
Structure Number: 16212526348, Location: 3 M SW I-294 (Lat: 41.587431, Lng: -87.727528), Route carried "under" structure: Interstate 57, Year Built: 1968, Structure Length: 9.75m (31.99ft), Average Daily Traffic: 122,500 (year 2009), Truck Traffic: 4%, Features Intersected: I- 57, Facility Carried by Structure: 167TH ST Minimum Vertical Clearance: 5.11m (16.77ft), Kilometerpoint: 557.679, Lanes on structure: 4, Lanes under structure: 10, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 35.1m (115.2ft)
Discuss this city on our hugely popular Illinois forum Back to: Oak Forest, IL, Illinois, All US cities.
|
![]() |