Bridge Statistics for Pinellas Park, Florida (FL) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Pinellas Park, FL, Florida, Florida forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 27 Total length: 110 meters (361ft) Total average daily traffic: 560,900 Total average daily truck traffic: 32,278 National Bridge Inventory (NBI) Registered Bridges for Pinellas Park
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Bridge Condition - Culverts Find on map >>
Structure Number: 150061, Location: 100ft. N/O 44TH AVE NORTH (Lat: 27.812778, Lng: -82.680000), Route carried "on" structure: US 19, Year Built: 1952, Status: Open, Structure Length: 0.94m (3.08ft), Average Daily Traffic: 49,000 (year 2006), Truck Traffic: 3%, Average Future Daily Traffic: 85,015 (year 2028), Design Load: HS 20+Mod, Features Intersected: JOES CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 11.796, Lanes on structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 25.9m (85.0ft), Skew: 24 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.9m (12.8ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft) Condition: Channel: Satisfactory, Culverts: Good, Inventory Rating: 55.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: March 2006 Find on map >>
Structure Number: 150064, Location: 0.8 MI E OF STARKEY ROAD (Lat: 27.840122, Lng: -82.751561), Route carried "on" structure: County highway 694, Year Built: 1976, Status: Open, Structure Length: 4.57m (14.99ft), Average Daily Traffic: 38,600 (year 2007), Truck Traffic: 4%, Average Future Daily Traffic: 48,250 (year 2027), Design Load: HS 20, Features Intersected: CROSS BAYOU Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 6, Owner: County Highway Agency, Approaching Roadway Width: 27.1m (88.9ft), Skew: 21 degrees, Material/Design: Prestressed concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 5, Length of Maximum Span: 9.1m (29.9ft), Curb or Sidewalk Widths: Left: 2.2m (7.2ft), Right: 2.2m (7.2ft), Curb-To-Curb Width: 27.2m (89.2ft), Out-to-Out Width: 33.5m (109.9ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Good, Operating Rating: 48.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: November 2007, Underwater Inspection Date: November 2007, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 150071, Location: 0.6 mi. S/O PARK BLVD. (Lat: 27.833333, Lng: -82.753889), Route carried "on" structure: County highway 695, Year Built: 1966, Status: Open, Structure Length: 12.19m (39.99ft), Average Daily Traffic: 16,500 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 20,625 (year 2027), Design Load: HS 20, Features Intersected: CROSS BAYOU CANAL, Facility Carried by Structure: PARK ST. N. (NB) Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 7.8m (25.6ft), Skew: 4 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 10, Length of Maximum Span: 12.2m (40.0ft), Curb or Sidewalk Widths: Left: 0.4m (1.3ft), Right: 0.4m (1.3ft), Curb-To-Curb Width: 9.0m (29.5ft), Out-to-Out Width: 10.7m (35.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Good, Operating Rating: 52.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 46.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of corrective action, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: November 2007, Underwater Inspection Date: November 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 150125, Location: 1.75 mi. W/O I-275 (Lat: 27.839444, Lng: -82.683889), Route carried "on" structure: State highway 694, Year Built: 1977, Status: Open, Structure Length: 11.09m (36.38ft), Average Daily Traffic: 62,000 (year 2006), Truck Traffic: 5%, Average Future Daily Traffic: 107,570 (year 2028), Design Load: HS 20+Mod, Features Intersected: US 19 SR 55 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 7, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 22.5m (73.8ft), Skew: 31 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 49.3m (161.7ft), Curb-To-Curb Width: 22.2m (72.8ft), Out-to-Out Width: 23.7m (77.8ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 59.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 36.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 150139, Location: 0.6 mi. S/O PARK BLVD. (Lat: 27.834428, Lng: -82.754594), Route carried "on" structure: County highway 695, Year Built: 1976, Status: Open, Structure Length: 12.19m (39.99ft), Average Daily Traffic: 16,500 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 20,625 (year 2027), Design Load: HS 20, Features Intersected: CROSS BAYOU CANAL, Facility Carried by Structure: PARK ST. N. (SB) Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 10.1m (33.1ft), Skew: 4 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 10, Length of Maximum Span: 12.3m (40.4ft), Curb-To-Curb Width: 10.1m (33.1ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Satisfactory, Operating Rating: 44.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 24 months, Inspection Date: November 2007, Underwater Inspection Date: November 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 150177, Location: 0.6 mi. N/O SR 694 (Lat: 27.848358, Lng: -82.728528), Route carried "on" structure: State highway 693, Year Built: 1980, Status: Open, Structure Length: 1.69m (5.54ft), Average Daily Traffic: 34,500 (year 2006), Truck Traffic: 4%, Average Future Daily Traffic: 59,858 (year 2028), Design Load: HS 20+Mod, Features Intersected: 84TH AVE FLOOD CANAL Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 14.066, Lanes on structure: 7, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 26.1m (85.6ft), Skew: 20 degrees, Material/Design: Prestressed concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 2, Length of Maximum Span: 8.5m (27.9ft), Curb or Sidewalk Widths: Left: 1.6m (5.2ft), Right: 1.6m (5.2ft), Curb-To-Curb Width: 26.1m (85.6ft), Out-to-Out Width: 30.4m (99.7ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Good, Operating Rating: 65.3 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 50.8 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: March 2006, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 150217, Location: 0.5 mi. E/ O US 19 (Lat: 27.846111, Lng: -82.676389), Route carried "on" structure: State highway 694, Year Built: 1951, Year Reconstructed: 1977, Status: Open, Structure Length: 0.91m (2.99ft), Average Daily Traffic: 62,000 (year 2006), Truck Traffic: 5%, Average Future Daily Traffic: 107,570 (year 2028), Design Load: H 15, Features Intersected: SAWGRASS CREEK, Facility Carried by Structure: GNDY BLVD&GRAND AV Minimum Vertical Clearance: 30.45m (99.90ft), Kilometerpoint: 1.146, Lanes on structure: 15, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 42.3m (138.8ft), Skew: 24 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 2.6m (8.5ft) Condition: Channel: Satisfactory, Culverts: Good, Inventory Rating: 63.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 150941, Location: 0.2 mi. N/O 38th AVE N (Lat: 27.807778, Lng: -82.679167), Route carried "on" structure: US 19, Year Built: 1952, Year Reconstructed: 1975, Status: Open, Structure Length: 6.53m (21.42ft), Average Daily Traffic: 49,000 (year 2006), Truck Traffic: 3%, Average Future Daily Traffic: 85,015 (year 2028), Design Load: H 20, Features Intersected: CSX RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 11.320, Lanes on structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 23.9m (78.4ft), Skew: 34 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 5, Length of Maximum Span: 16.8m (55.1ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 11.7m (38.4ft), Out-to-Out Width: 26.1m (85.6ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Good, Operating Rating: 48.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 29.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: March 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 15436, Location: 0.1 mi. N/O 90TH AVE. (Lat: 27.855000, Lng: -82.712222), Route carried "on" structure: City street , Year Built: 1965, Status: Open, Structure Length: 1.25m (4.10ft), Average Daily Traffic: 3,192 (year 2007), Truck Traffic: 2%, Average Future Daily Traffic: 3,990 (year 2027), Features Intersected: REDHEAD CANAL, Facility Carried by Structure: 58TH ST. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Material/Design: Prestressed concrete, Design/Construction: Channel Beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 6.3m (20.7ft), Curb or Sidewalk Widths: Left: 1.2m (3.9ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 11.3m (37.1ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Good, Channel: Good, Operating Rating: 90.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 62.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 154361, Location: 0.5 MI EAST OF BELCHER RD (Lat: 27.872222, Lng: -82.737056), Route carried "on" structure: County highway , Year Built: 1970, Status: Open, Structure Length: 1.16m (3.81ft), Average Daily Traffic: 47,400 (year 2007), Truck Traffic: 15%, Average Future Daily Traffic: 59,250 (year 2027), Design Load: H 20, Features Intersected: RED CREEK CANAL, Facility Carried by Structure: BRYAN DAIRY RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 7, Owner: County Highway Agency, Approaching Roadway Width: 29.9m (98.1ft), Skew: 20 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 4, Length of Maximum Span: 2.7m (8.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft) Condition: Channel: Satisfactory, Culverts: Good, Operating Rating: 74.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 44.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 154365, Location: 1.1Miles West of US 19 (Lat: 27.872778, Lng: -82.728972), Route carried "on" structure: County highway 296, Year Built: 2002, Status: Open, Structure Length: 16.09m (52.79ft), Average Daily Traffic: 30,700 (year 2007), Truck Traffic: 10%, Average Future Daily Traffic: 38,375 (year 2027), Design Load: HS 20+Mod, Features Intersected: 66TH STREET NORTH, Facility Carried by Structure: BRYAN DAIRY RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.863, Lanes on structure: 6, Lanes under structure: 10, Owner: County Highway Agency, Approaching Roadway Width: 33.4m (109.6ft), Skew: 30 degrees, Material/Design: Steel continuous, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 3, Length of Maximum Span: 85.3m (279.9ft), Curb-To-Curb Width: 33.4m (109.6ft), Out-to-Out Width: 34.9m (114.5ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Very good, Operating Rating: 56.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 33.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 154403, Location: 0.6 MI E OF 66TH ST NORTH (Lat: 27.828306, Lng: -82.727500), Route carried "on" structure: County highway , Year Built: 1965, Status: Open, Structure Length: 0.88m (2.89ft), Average Daily Traffic: 8,200 (year 2007), Truck Traffic: 10%, Average Future Daily Traffic: 10,250 (year 2027), Features Intersected: BONN CREEK, Facility Carried by Structure: 62ND AVE NORTH Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 6.0m (19.7ft), Skew: 4 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.0m (13.1ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 42.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 25.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 154406, Location: 0.2 mi N/O 62nd Ave. N (Lat: 27.833389, Lng: -82.712806), Route carried "on" structure: City street , Year Built: 1965, Status: Open, Structure Length: 0.76m (2.49ft), Average Daily Traffic: 6,305 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 7,881 (year 2027), Features Intersected: DEEP CANAL, Facility Carried by Structure: 58TH ST N Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.0m (23.0ft), Material/Design: Prestressed concrete, Design/Construction: Channel Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.6m (24.9ft), Curb or Sidewalk Widths: Left: 1.2m (3.9ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 7.4m (24.3ft), Out-to-Out Width: 10.8m (35.4ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Good, Operating Rating: 45.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 30.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 154548, Location: 0.3MI S. Of 54th AVE. (Lat: 27.816250, Lng: -82.684028), Route carried "on" structure: City street , Year Built: 1999, Status: Open, Structure Length: 0.76m (2.49ft), Average Daily Traffic: 800 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 1,000 (year 2027), Design Load: HS 20, Features Intersected: JOES CREEK, Facility Carried by Structure: 37th STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 6.4m (21.0ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.2m (23.6ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft) Condition: Channel: Satisfactory, Culverts: Very good, Operating Rating: 51.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 31.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2007 Find on map >>
Structure Number: 1567, Location: 650 ft. W/O 60TH STREET N (Lat: 27.853219, Lng: -82.718722), Route carried "on" structure: City street , Year Built: 1965, Status: Open, Structure Length: 1.77m (5.81ft), Average Daily Traffic: 1,506 (year 2007), Truck Traffic: 2%, Average Future Daily Traffic: 1,882 (year 2027), Features Intersected: REDHEAD CANAL, Facility Carried by Structure: 90TH AVE N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.4m (21.0ft), Skew: 5 degrees, Material/Design: Prestressed concrete, Design/Construction: Channel Beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 8.8m (28.9ft), Curb or Sidewalk Widths: Left: 1.0m (3.3ft), Right: 1.0m (3.3ft), Curb-To-Curb Width: 7.5m (24.6ft), Out-to-Out Width: 11.3m (37.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 46.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 27.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 156701, Location: 0.1 mi. N/O 90TH AVE. N. (Lat: 27.854444, Lng: -82.716083), Route carried "on" structure: City street , Year Built: 1965, Status: Open, Structure Length: 1.77m (5.81ft), Average Daily Traffic: 4,608 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 5,760 (year 2027), Features Intersected: REDHEAD CANAL, Facility Carried by Structure: 60TH STREET N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.108, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Skew: 3 degrees, Material/Design: Prestressed concrete, Design/Construction: Channel Beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 8.8m (28.9ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 10.9m (35.8ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 67.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 56.1 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 156702, Location: 950 ft. N/O 62ND AVE N. (Lat: 27.831667, Lng: -82.720556), Route carried "on" structure: City street , Year Built: 1965, Status: Open, Structure Length: 0.88m (2.89ft), Average Daily Traffic: 2,458 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 3,072 (year 2027), Features Intersected: GOOSE CANAL, Facility Carried by Structure: 62ND ST. N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.0m (19.7ft), Material/Design: Prestressed concrete, Design/Construction: Channel Beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 8.8m (28.9ft), Curb or Sidewalk Widths: Left: 1.2m (3.9ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 7.4m (24.3ft), Out-to-Out Width: 11.3m (37.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 86.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 51.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: High priority of replacement, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 156703, Location: 0.4 mi. W/O SR 693 (Lat: 27.879833, Lng: -82.735833), Route carried "on" structure: City street , Year Built: 1970, Status: Open, Structure Length: 0.89m (2.92ft), Average Daily Traffic: 5,200 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 7,746 (year 2027), Features Intersected: SHADY CANAL, Facility Carried by Structure: 118TH AVE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 2.7m (8.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m Condition: Channel: Good, Culverts: Good, Operating Rating: 44.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 26.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 156704, Location: 135 ft N/O 97TH TERR. N. (Lat: 27.860667, Lng: -82.708333), Route carried "on" structure: City street , Year Built: 1993, Status: Open, Structure Length: 0.61m (2.00ft), Average Daily Traffic: 505 (year 2007), Truck Traffic: 1%, Average Future Daily Traffic: 631 (year 2027), Design Load: HS 20, Features Intersected: CHANNEL #1, Facility Carried by Structure: 55TH ST. N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.8m (22.3ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 6.1m (20.0ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 44.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 26.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 156705, Location: 300 ft N/O 94TH AVE NORTH (Lat: 27.858333, Lng: -82.712500), Route carried "on" structure: City street , Year Built: 1993, Status: Open, Structure Length: 0.80m (2.62ft), Average Daily Traffic: 2,918 (year 2007), Truck Traffic: 2%, Average Future Daily Traffic: 3,648 (year 2027), Design Load: HS 20, Features Intersected: CHANNEL # 1, Facility Carried by Structure: 58TH. ST. N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.3m (20.7ft), Skew: 1 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.7m (12.1ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.2m (3.9ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 66.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 156706, Location: 300 ft. S/O GATEWAY BLVD. (Lat: 27.850833, Lng: -82.687778), Route carried "on" structure: City street , Year Built: 1993, Status: Open, Structure Length: 0.64m (2.10ft), Average Daily Traffic: 1,276 (year 2007), Truck Traffic: 1%, Average Future Daily Traffic: 1,595 (year 2027), Design Load: HS 20, Features Intersected: CHANNEL #2A, Facility Carried by Structure: 40TH ST. N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 9.5m (31.2ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.0m (9.8ft), Curb or Sidewalk Widths: Left: 1.4m (4.6ft), Right: 0.0m Condition: Channel: Good, Culverts: Good, Operating Rating: 74.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 44.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 156707, Location: 300 ft. W/O 58TH ST NORTH (Lat: 27.857500, Lng: -82.713056), Route carried "on" structure: City street , Year Built: 1993, Status: Open, Structure Length: 1.28m (4.20ft), Average Daily Traffic: 6,880 (year 2007), Truck Traffic: 2%, Average Future Daily Traffic: 8,600 (year 2027), Design Load: HS 20, Features Intersected: CHANNEL #1, Facility Carried by Structure: 94TH AVE N. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 3, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 13.1m (43.0ft), Skew: 4 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 1, Length of Maximum Span: 12.8m (42.0ft), Curb or Sidewalk Widths: Left: 2.1m (6.9ft), Right: 2.2m (7.2ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 90.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 81.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Better than present minimum criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007 Find on map >>
Structure Number: 156708, Location: 0.25 mi. S/O 70th AVE. (Lat: 27.832386, Lng: -82.687611), Route carried "on" structure: City street , Year Built: 1997, Status: Open, Structure Length: 1.22m (4.00ft), Average Daily Traffic: 101 (year 2007), Truck Traffic: 1%, Average Future Daily Traffic: 125 (year 2027), Design Load: HS 20, Features Intersected: PPWMD CHANNEL 3, Facility Carried by Structure: 40th ST.PK ENT Minimum Vertical Clearance: 30.45m (99.90ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Material/Design: Prestressed concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 2, Length of Maximum Span: 6.1m (20.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m, Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 10.3m (33.8ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Good, Channel: Very good, Operating Rating: 78.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 47.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 156709, Location: 0.25 mi. S/O 70th AVE. (Lat: 27.831944, Lng: -82.689444), Route carried "on" structure: City street , Year Built: 1997, Status: Open, Structure Length: 1.18m (3.87ft), Average Daily Traffic: 101 (year 2007), Truck Traffic: 1%, Average Future Daily Traffic: 125 (year 2027), Design Load: HS 20, Features Intersected: PPWMD CHANNEL 3, Facility Carried by Structure: 41st PARK ENTRANCE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.5m (24.6ft), Material/Design: Prestressed concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 2, Length of Maximum Span: 5.9m (19.4ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.8m (5.9ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 10.3m (33.8ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Channel: Very good, Operating Rating: 85.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 51.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 15671, Location: 0.3 mi. N/O 62nd AVE. (Lat: 27.833056, Lng: -82.681333), Route carried "on" structure: City street , Year Built: 1997, Status: Open, Structure Length: 1.26m (4.13ft), Average Daily Traffic: 1,000 (year 2007), Truck Traffic: 5%, Average Future Daily Traffic: 3,000 (year 2027), Design Load: HS 20, Features Intersected: PPWMD CHANNEL 3, Facility Carried by Structure: 35th STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.6m (24.9ft), Material/Design: Prestressed concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 2, Length of Maximum Span: 6.3m (20.7ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 12.3m (40.4ft) Condition: Deck: Good, Superstructure: Good, Substructure: Very good, Channel: Very good, Operating Rating: 76.2 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 45.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2007, Deck Structure Type: Concrete Precast Panels, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 150125, Location: 1.75 mi. W/O I-275 (Lat: 27.839444, Lng: -82.683889), Route carried "under" structure: US 19, Year Built: 1977, Structure Length: 11.09m (36.38ft), Average Daily Traffic: 67,500 (year 2006), Truck Traffic: 3%, Features Intersected: US 19 SR 55, Facility Carried by Structure: SR 694 Minimum Vertical Clearance: 4.94m (16.21ft), Kilometerpoint: 14.843, Lanes on structure: 4, Lanes under structure: 7, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 49.3m (161.7ft) Find on map >>
Structure Number: 154365, Location: 1.1Miles West of US 19 (Lat: 27.872778, Lng: -82.728972), Route carried "under" structure: State highway 693, Year Built: 2002, Structure Length: 16.09m (52.79ft), Average Daily Traffic: 42,150 (year 2007), Truck Traffic: 10%, Features Intersected: 66TH STREET NORTH, Facility Carried by Structure: BRYAN DAIRY RD Minimum Vertical Clearance: 5.52m (18.11ft), Kilometerpoint: 16.684, Lanes on structure: 6, Lanes under structure: 10, Material/Design: Steel continuous, Design/Construction: Box Beam or Girders - Single/Spread, Length of Maximum Span: 85.3m (279.9ft) Discuss this city on our hugely popular Florida forum Back to: Pinellas Park, FL, Florida, All US cities.
|
![]() |