Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Pineville, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 194ft / 59.2mTotal length
  • 442,850Total average daily traffic
  • 57,357Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Pineville
  • No street view available for this location

New bridges in Pineville, NC - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11950-1959
  • 11960-1969
  • 81990-1999
  • 42010-2019
Reconstructed bridges in Pineville, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 11980-1989
  • 01990-1999
  • 22000-2009
Average Bridge Daily Traffic in Pineville, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 55.6%Good
  • 22.2%Satisfactory
  • 22.2%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 22.2%Very good
  • 55.6%Good
  • 22.2%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.1%Very good
  • 55.6%Good
  • 22.2%Satisfactory
  • 11.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 33.3%Satisfactory
  • 16.7%Fair
Find on map >>   Show street view

Structure Number: 1190017,  Location: 0.6 MI. S. JCT. SR3637 (Lat: 35.062808,  Lng: -80.876944),  Route carried "on" structure: State highway 4982,  Year Built: 1926,  Year Reconstructed: 1961,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 22,000 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 44,000 (year 2040),  Design Load: H 15,  Features Intersected: MCALPINE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.5m (50.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1190025,  Location: 50 FT. N. JCT. SR3645 (Lat: 35.090650,  Lng: -80.899350),  Route carried "on" structure: State highway 51,  Year Built: 1968,  Status: Open,  Structure Length: 5.05m (16.57ft),  Average Daily Traffic: 20,000 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 40,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SUGAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.4m (53.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190049,  Location: 0.25 MI. N. JCT. SR3640 (Lat: 35.079453,  Lng: -80.885242),  Route carried "on" structure: State highway 4982,  Year Built: 2016,  Status: Open,  Structure Length: 5.48m (17.98ft),  Average Daily Traffic: 14,500 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 29,000 (year 2040),  Design Load: HL 93,  Features Intersected: LITTLE SUGAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 58.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190053,  Location: 0.22 MI. N. JCT. US521 (Lat: 35.085117,  Lng: -80.882311),  Route carried "on" structure: State highway 51,  Year Built: 1958,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 27,000 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 54,000 (year 2040),  Design Load: HS 15,  Features Intersected: LITTLE SUGAR CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 3,  Length of Maximum Span: 10.3m (33.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 46.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1190601,  Location: 1.8 MI. S. JCT. SR1138 (Lat: 35.114428,  Lng: -80.923381),  Route carried "on" structure: Ramp Interstate 77,  Year Built: 1992,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 21,750 (year 2012),  Truck Traffic: 16%,  Average Future Daily Traffic: 43,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1128
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.243,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 36.5m (119.8ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190606,  Location: 1.0 MI. E. JCT. US51 (Lat: 35.088478,  Lng: -80.874272),  Route carried "on" structure: Interstate 485,  Year Built: 1992,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 77,000 (year 2018),  Truck Traffic: 16%,  Average Future Daily Traffic: 154,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NC51
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.507,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 85),  Owner: State Highway Agency,  Approaching Roadway Width: 23.1m (75.8ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 37.7m (123.7ft),  Curb-To-Curb Width: 16.4m (53.8ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190607,  Location: 2.7 MI. W. JCT. US521 (Lat: 35.088339,  Lng: -80.874589),  Route carried "on" structure: Interstate 485,  Year Built: 1992,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 6.12m (20.08ft),  Average Daily Traffic: 58,000 (year 2012),  Truck Traffic: 16%,  Average Future Daily Traffic: 116,000 (year 2040),  Design Load: HL 93,  Features Intersected: NC51
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.507,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 21),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 11 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 37.7m (123.7ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 47.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1191356,  Location: .1 MI N LONGVIEW CLUB DR (Lat: 35.030111,  Lng: -80.792806),  Route carried "on" structure: State highway 4968,  Year Built: 1997,  Status: Open,  Structure Length: 6.03m (19.78ft),  Average Daily Traffic: 6,100 (year 2014),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,200 (year 2040),  Design Load: HL 93,  Features Intersected: UT TO SIXMILE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Fair,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1191359,  Location: 0.5 MI S OF JOHNSTON RD (Lat: 35.065361,  Lng: -80.838167),  Route carried "on" structure: State highway ,  Year Built: 2015,  Status: Open,  Structure Length: 13.41m (44.00ft),  Average Daily Traffic: 6,000 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,000 (year 2040),  Design Load: HL 93,  Features Intersected: I 485 &UT TO MCALPINE C,  Facility Carried by Structure: N COMM HOUSE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 17.9m (58.7ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 40.5m (132.9ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 2.2m (7.2ft),  Curb-To-Curb Width: 18.7m (61.4ft),  Out-to-Out Width: 24.1m (79.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1190606,  Location: 1.0 MI. E. JCT. US51 (Lat: 35.088478,  Lng: -80.874272),  Route carried "under" structure: State highway 51,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 27,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: I485 WBL
Minimum Vertical Clearance: 5.84m (19.16ft),  Kilometerpoint: 19.507,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 1190606,  Location: 1.0 MI. E. JCT. US51 (Lat: 35.088478,  Lng: -80.874272),  Route carried "under" structure: State highway 51,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 27,500 (year 2018),  Truck Traffic: 12%,  Features Intersected: I485 WBL
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 19.507,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 1190607,  Location: 2.7 MI. W. JCT. US521 (Lat: 35.088339,  Lng: -80.874589),  Route carried "under" structure: State highway 51,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 23,250 (year 2012),  Truck Traffic: 12%,  Features Intersected: I485 EBL
Minimum Vertical Clearance: 5.71m (18.73ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 1190607,  Location: 2.7 MI. W. JCT. US521 (Lat: 35.088339,  Lng: -80.874589),  Route carried "under" structure: State highway 51,  Year Built: 1992,  Structure Length: 0. m,  Average Daily Traffic: 23,250 (year 2012),  Truck Traffic: 12%,  Features Intersected: I485 EBL
Minimum Vertical Clearance: 6.30m (20.67ft),  Kilometerpoint: 19.507,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.7m (123.7ft)

Find on map >>   Show street view

Structure Number: 1191359,  Location: 0.5 MI S OF JOHNSTON RD (Lat: 35.065361,  Lng: -80.838167),  Route carried "under" structure: Interstate 485,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 38,000 (year 2015),  Truck Traffic: 16%,  Features Intersected: N COMM HOUSE RD
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>   Show street view

Structure Number: 1191359,  Location: 0.5 MI S OF JOHNSTON RD (Lat: 35.065361,  Lng: -80.838167),  Route carried "under" structure: Interstate 485,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 51,000 (year 2015),  Truck Traffic: 16%,  Features Intersected: N COMM HOUSE RD
Minimum Vertical Clearance: 5.58m (18.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Discuss Pineville, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.