U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Rancho Santa Margarita, California (CA) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Rancho Santa Margarita, CA, California, California forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 34
Total length: 499 meters (1,637ft)
Total average daily traffic: 412,020
Total average daily truck traffic: 4,914
National Bridge Inventory (NBI) Registered Bridges for Rancho Santa Margarita

New bridges - Historical Statistics

  • 1980-1989: 1
  • 1990-1999: 31
  • 2000-2009: 2

Reconstructed bridges - Historical Statistics

  • 1990-1999: 2
  • 2000-2009: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 55 0697,  Location: 12-ORA-241-17.6-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 8.75m (28.71ft),  Design Load: HS 20+Mod,  Features Intersected: SR 241,  Facility Carried by Structure: ANTONIO PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 37.0m (121.4ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.8m (147.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 37.0m (121.4ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0699,  Location: 12-ORA-241-18.53-RSM (Lat: 33.476667,  Lng: -117.601667),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 9.60m (31.50ft),  Design Load: HS 20+Mod,  Features Intersected: SR 241,  Facility Carried by Structure: STA MARGARITA PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 5,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 49.1m (161.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 33.5m (109.9ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0700L,  Location: 12-ORA-241-18.7-RSM (Lat: 33.646667,  Lng: -117.603333),  Route carried "on" structure: State highway 241,  Year Built: 1995,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 42.67m (139.99ft),  Average Daily Traffic: 7,900 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: TRABUCO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.700,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 25.2m (82.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 56.4m (185.0ft),  Curb-To-Curb Width: 25.2m (82.7ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0700R,  Location: 12-ORA-241-18.7-RSM (Lat: 33.646667,  Lng: -117.603333),  Route carried "on" structure: State highway 241,  Year Built: 1995,  Status: Open,  Structure Length: 43.43m (142.49ft),  Average Daily Traffic: 7,900 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: TRABUCO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.700,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 28.8m (94.5ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 56.3m (184.7ft),  Curb-To-Curb Width: 28.8m (94.5ft),  Out-to-Out Width: 33.5m (109.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0701L,  Location: 12-ORA-241-19.33-RSM (Lat: 33.653333,  Lng: -117.615000),  Route carried "on" structure: State highway 241,  Year Built: 1995,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.00m (16.40ft),  Average Daily Traffic: 7,900 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: MELINDA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.330,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 49.1m (161.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0701R,  Location: 12-ORA-241-19.33-RSM (Lat: 33.653333,  Lng: -117.615000),  Route carried "on" structure: State highway 241,  Year Built: 1995,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.07m (16.63ft),  Average Daily Traffic: 7,900 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: MELINDA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.330,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 50.0m (164.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 30.3m (99.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0702,  Location: 12-ORA-241-20.12-RSM (Lat: 33.655000,  Lng: -117.628333),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 8.99m (29.49ft),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 241,  Facility Carried by Structure: LOS ALISOS BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 46.0m (150.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 25.6m (84.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0715K,  Location: 12-ORA-241-17.40-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: Ramp State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 11.65m (38.22ft),  Design Load: HS 20+Mod,  Features Intersected: Tijeras Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.400,  Lanes on structure: 2,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.8m (117.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0715L,  Location: 12-ORA-241-17.4-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 12.25m (40.19ft),  Average Daily Traffic: 3,650 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: Tijeras Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.400,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 37.6m (123.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0715R,  Location: 12-ORA-241-17.4-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 12.39m (40.65ft),  Average Daily Traffic: 3,650 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: Tijeras Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.400,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 18.5m (60.7ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 18.5m (60.7ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0802,  Location: 12-ORA-241-32.37-RSM (Lat: 33.780556,  Lng: -117.748056),  Route carried "on" structure: Ramp State highway 241,  Year Built: 1997,  Status: Open,  Structure Length: 18.62m (61.09ft),  Average Daily Traffic: 20,000 (year 2000),  Average Future Daily Traffic: 23,699 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SR 241
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.370,  Lanes on structure: 4,  Lanes under structure: 4,  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 61.0m (200.1ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0803,  Location: 12-ORA-241-32.52-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 17.37m (56.99ft),  Average Daily Traffic: 9,400 (year 2005),  Average Future Daily Traffic: 11,334 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SR 241,  Facility Carried by Structure: CHAPMAN-SANTIAGO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 65.8m (215.9ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0823L,  Location: 12-ORA-241-33.7-RSM (Lat: 33.794444,  Lng: -117.732222),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 38.71m (127.00ft),  Average Daily Traffic: 20,500 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 25,760 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SANTIAGO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.700,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 70.1m (230.0ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0823R,  Location: 12-ORA-241-33.7-RSM (Lat: 33.792778,  Lng: -117.730278),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 38.71m (127.00ft),  Average Daily Traffic: 20,500 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 25,760 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SANTIAGO CREEK
Minimum Vertical Clearance: 25.00m (82.02ft),  Kilometerpoint: 33.700,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 70.1m (230.0ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0895,  Location: 12-ORA-241-28.7-RSM (Lat: 33.736389,  Lng: -117.717778),  Route carried "on" structure: State highway 241,  Year Built: 1997,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 35,000 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 46,368 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: HAUL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.700,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 28.6m (93.8ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.5m (155.8ft),  Curb-To-Curb Width: 28.6m (93.8ft),  Out-to-Out Width: 30.3m (99.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0895L,  Location: 12-ORA-241-28.7-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 4.30m (14.11ft),  Design Load: HS 20+Mod,  Features Intersected: HAUL ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.700,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.0m (141.1ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Fair,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0958,  Location: 12-ORA-241-31.66-RSM (Lat: 33.771667,  Lng: -117.741111),  Route carried "on" structure: Other road ,  Year Built: 1997,  Status: Open,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 200 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 309 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SR 241,  Facility Carried by Structure: EOC ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 53.0m (173.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0996L,  Location: 12-ORA-241-16-RSM (Lat: 33.610833,  Lng: -117.611944),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 3,650 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: Wildlife
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.000,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55 0996R,  Location: 12-ORA-241-16-RSM (Lat: 33.610556,  Lng: -117.611389),  Route carried "on" structure: State highway 241,  Year Built: 1998,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 3,650 (year 2000),  Design Load: HS 20+Mod,  Features Intersected: Wildlife
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Toll: On toll road,  Owner: Local Agency,  Maintenance Responsibility: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55C0520L,  Location: 0.2 MI E/O ALICIA PARKWAY (Lat: 33.638333,  Lng: -117.617500),  Route carried "on" structure: County highway W458,  Year Built: 1991,  Status: Open,  Structure Length: 36.79m (120.70ft),  Average Daily Traffic: 23,000 (year 2002),  Truck Traffic: 1%,  Average Future Daily Traffic: 46,928 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ARROYO TRABUCO,  Facility Carried by Structure: W/B SNTA MRGTA PWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 56.1m (184.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55C0520R,  Location: 0.2 MI. SE/O ALICIA PKWY (Lat: 33.636944,  Lng: -117.615833),  Route carried "on" structure: County highway W458,  Year Built: 1984,  Status: Open,  Structure Length: 36.58m (120.01ft),  Average Daily Traffic: 23,000 (year 2002),  Truck Traffic: 3%,  Average Future Daily Traffic: 46,928 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ARROYO TRABUCO,  Facility Carried by Structure: E/B SNTA MRGTA PWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 56.1m (184.1ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 20.6m (67.6ft)

Condition: Deck: Poor,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 55C0605,  Location: 0.8 MI SW/O AVENIDA BNDRA (Lat: 33.605000,  Lng: -117.621944),  Route carried "on" structure: County highway ,  Year Built: 1991,  Status: Open,  Structure Length: 12.86m (42.19ft),  Average Daily Traffic: 20,000 (year 1999),  Truck Traffic: 1%,  Average Future Daily Traffic: 41,216 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: TIJERAS CREEK,  Facility Carried by Structure: ANTONIO PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 29 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 30,  Length of Maximum Span: 51.2m (168.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 36.0m (118.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 55 0697,  Location: 12-ORA-241-17.6-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "under" structure: State highway 241,  Year Built: 1998,  Structure Length: 8.75m (28.71ft),  Average Daily Traffic: 15,800 (year 2000),  Features Intersected: SR 241,  Facility Carried by Structure: ANTONIO PARKWAY
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.176,  Lanes on structure: 8,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 44.8m (147.0ft)

Find on map >>

Structure Number: 55 0699,  Location: 12-ORA-241-18.53-RSM (Lat: 33.476667,  Lng: -117.601667),  Route carried "under" structure: State highway 241,  Year Built: 1995,  Structure Length: 9.60m (31.50ft),  Average Daily Traffic: 15,800 (year 2000),  Features Intersected: SR 241,  Facility Carried by Structure: STA MARGARITA PKWY
Minimum Vertical Clearance: 5.47m (17.95ft),  Kilometerpoint: 1.853,  Lanes on structure: 8,  Lanes under structure: 5,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 49.1m (161.1ft)

Find on map >>

Structure Number: 55 0701L,  Location: 12-ORA-241-19.33-RSM (Lat: 33.653333,  Lng: -117.615000),  Route carried "under" structure: County highway ,  Year Built: 1995,  Structure Length: 5.00m (16.40ft),  Features Intersected: MELINDA ROAD,  Facility Carried by Structure: STATE ROUTE 241 SB
Minimum Vertical Clearance: 5.87m (19.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 49.1m (161.1ft)

Find on map >>

Structure Number: 55 0701R,  Location: 12-ORA-241-19.33-RSM (Lat: 33.653333,  Lng: -117.615000),  Route carried "under" structure: County highway ,  Year Built: 1995,  Structure Length: 5.07m (16.63ft),  Features Intersected: MELINDA ROAD,  Facility Carried by Structure: STATE ROUTE 241 NB
Minimum Vertical Clearance: 7.42m (24.34ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 50.0m (164.0ft)

Find on map >>

Structure Number: 55 0702,  Location: 12-ORA-241-20.12-RSM (Lat: 33.655000,  Lng: -117.628333),  Route carried "under" structure: State highway 241,  Year Built: 1995,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 15,800 (year 2000),  Features Intersected: ROUTE 241,  Facility Carried by Structure: LOS ALISOS BLVD
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 2.012,  Lanes on structure: 5,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 46.0m (150.9ft)

Find on map >>

Structure Number: 55 0802,  Location: 12-ORA-241-32.37-RSM (Lat: 33.780556,  Lng: -117.748056),  Route carried "under" structure: State highway 241,  Year Built: 1997,  Structure Length: 18.62m (61.09ft),  Average Daily Traffic: 48,000 (year 2005),  Truck Traffic: 2%,  Features Intersected: SR 241
Minimum Vertical Clearance: 5.86m (19.23ft),  Kilometerpoint: 3.237,  Lanes on structure: 4,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 61.0m (200.1ft)

Find on map >>

Structure Number: 55 0803,  Location: 12-ORA-241-32.52-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "under" structure: State highway 241,  Year Built: 1997,  Structure Length: 17.37m (56.99ft),  Average Daily Traffic: 48,000 (year 2005),  Truck Traffic: 2%,  Features Intersected: SR 241,  Facility Carried by Structure: CHAPMAN-SANTIAGO
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 3.252,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 65.8m (215.9ft)

Find on map >>

Structure Number: 55 0895,  Location: 12-ORA-241-28.7-RSM (Lat: 33.736389,  Lng: -117.717778),  Route carried "under" structure: Other road ,  Year Built: 1997,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 10 (year 2000),  Truck Traffic: 1%,  Features Intersected: HAUL ROAD,  Facility Carried by Structure: SR 241
Minimum Vertical Clearance: 0.78m (2.56ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 47.5m (155.8ft)

Find on map >>

Structure Number: 55 0895L,  Location: 12-ORA-241-28.7-RSM (Lat: 33.000000,  Lng: -117.000000),  Route carried "under" structure: Other road ,  Year Built: 1998,  Structure Length: 4.30m (14.11ft),  Average Daily Traffic: 10 (year 2000),  Truck Traffic: 1%,  Features Intersected: HAUL ROAD,  Facility Carried by Structure: SR 241
Minimum Vertical Clearance: 7.03m (23.06ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: 55 0953,  Location: 12-ORA-241-18.64-RSM (Lat: 33.644444,  Lng: -117.604444),  Route carried "under" structure: State highway 241,  Year Built: 2000,  Structure Length: 11.62m (38.12ft),  Average Daily Traffic: 15,800 (year 2000),  Features Intersected: SR 241,  Facility Carried by Structure: TRABUCO BKE TRL OC
Minimum Vertical Clearance: 0.66m (2.17ft),  Kilometerpoint: 1.864,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 48.6m (159.4ft)

Find on map >>

Structure Number: 55 0953,  Location: 12-ORA-241-18.64-RSM (Lat: 33.644444,  Lng: -117.604444),  Route carried "under" structure: Ramp State highway 241,  Year Built: 2000,  Structure Length: 11.62m (38.12ft),  Features Intersected: SR 241,  Facility Carried by Structure: TRABUCO BKE TRL OC
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 1.864,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 48.6m (159.4ft)

Find on map >>

Structure Number: 55 0958,  Location: 12-ORA-241-31.66-RSM (Lat: 33.771667,  Lng: -117.741111),  Route carried "under" structure: State highway 241,  Year Built: 1997,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 35,000 (year 2000),  Truck Traffic: 2%,  Features Intersected: SR 241,  Facility Carried by Structure: EOC ROAD
Minimum Vertical Clearance: 14.88m (48.82ft),  Kilometerpoint: 3.166,  Lanes on structure: 2,  Lanes under structure: 6,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 53.0m (173.9ft)

Discuss this city on our hugely popular California forum

Back to: Rancho Santa Margarita, CA, California, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.