U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Renton, Washington (WA) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Renton, WA, Washington, Washington forum, All US cities.


Parts: 1, 2


National Bridge Inventory (NBI) Statistics
Number of bridges: 60
Total length: 359 meters (1,178ft)
Total costs: $6,410,000
Total average daily traffic: 4,969,170
Total average daily truck traffic: 144,548
National Bridge Inventory (NBI) Registered Bridges for Renton

New bridges - Historical Statistics

  • 1920-1929: 1
  • 1930-1939: 0
  • 1940-1949: 1
  • 1950-1959: 4
  • 1960-1969: 21
  • 1970-1979: 2
  • 1980-1989: 8
  • 1990-1999: 20
  • 2000-2009: 3

Reconstructed bridges - Historical Statistics

  • 1960-1969: 1
  • 1970-1979: 1
  • 1980-1989: 9
  • 1990-1999: 0
  • 2000-2009: 1

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 2504A,  Location: 0.2 E JCT SR 515 (Lat: 47.482083,  Lng: -122.202889),  Route carried "on" structure: State highway 900,  Year Built: 1940,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 24,939 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 38,900 (year 2026),  Design Load: H 15,  Features Intersected: CEDAR R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.250,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Critical Feature Inspection Date: September 2006,  Bridge Improvement Cost: $130,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $195,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 5347B,  Location: 1.7 N JCT SR 900 (Lat: 47.528000,  Lng: -122.197556),  Route carried "on" structure: Interstate 405,  Year Built: 1958,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 73,500 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 89,700 (year 2026),  Design Load: HS 20,  Features Intersected: MAY CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.540,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $95,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $143,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 5347C,  Location: 1.7 N JCT SR 900 (Lat: 47.527917,  Lng: -122.198083),  Route carried "on" structure: Interstate 405,  Year Built: 1958,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 73,500 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 89,700 (year 2026),  Design Load: HS 20,  Features Intersected: MAY CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.540,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 22.1m (72.5ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $138,000,  Roadway Improvement Cost: $14,000,  Total Project Cost: $207,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 6912B,  Location: 0.5 N JCT SR 169 (Lat: 47.490000,  Lng: -122.191667),  Route carried "on" structure: Interstate 405,  Year Built: 1963,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 8.72m (28.61ft),  Average Daily Traffic: 118,903 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 145,100 (year 2026),  Design Load: HS 20,  Features Intersected: SR 900 0C SUNSET BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.220,  Lanes on structure: 6,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 35 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 33.5m (109.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 71.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $195,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $293,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 7085B,  Location: 3.8 N JCT SR 516 (Lat: 47.440000,  Lng: -122.216667),  Route carried "on" structure: City street 167,  Year Built: 1964,  Year Reconstructed: 1973,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 29,500 (year 2002),  Truck Traffic: 5%,  Average Future Daily Traffic: 30,090 ,  Design Load: HS 20,  Features Intersected: SR 167,  Facility Carried by Structure: S 180TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 39.290,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 31.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $170,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $255,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 7155B,  Location: 0.6 N JCT SR 167 (Lat: 47.470000,  Lng: -122.206667),  Route carried "on" structure: City street 405,  Year Built: 1964,  Status: Open,  Structure Length: 8.44m (27.69ft),  Average Daily Traffic: 15,267 (year 1994),  Truck Traffic: 8%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20,  Features Intersected: I-405,  Facility Carried by Structure: SR 515 (BENSON RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.600,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $84,000,  Roadway Improvement Cost: $8,000,  Total Project Cost: $126,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 7376A,  Location: 1.3 N JCT SR 181 (Lat: 47.468333,  Lng: -122.216667),  Route carried "on" structure: Interstate 405,  Year Built: 1964,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 77,792 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 94,900 (year 2026),  Design Load: HS 20,  Features Intersected: SR 167
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.700,  Lanes on structure: 9,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 55.5m (182.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.1m (56.1ft),  Curb-To-Curb Width: 56.1m (184.1ft),  Out-to-Out Width: 57.6m (189.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 49.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $197,000,  Roadway Improvement Cost: $20,000,  Total Project Cost: $296,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 7376C,  Location: 0.5 N JCT SR 167 (Lat: 47.468889,  Lng: -122.208056),  Route carried "on" structure: Interstate 405,  Year Built: 1964,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 77,792 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 94,900 (year 2026),  Design Load: HS 20,  Features Intersected: BURNETT ST TALBOT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.460,  Lanes on structure: 6,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 32.9m (107.9ft),  Out-to-Out Width: 33.4m (109.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $156,000,  Roadway Improvement Cost: $16,000,  Total Project Cost: $234,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 7437A,  Location: 0.6 N JCT SR 181 (Lat: 47.466667,  Lng: -122.233333),  Route carried "on" structure: Interstate 405,  Year Built: 1964,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 139,576 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 170,300 (year 2026),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.490,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 12 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 15.5m (50.9ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $183,000,  Roadway Improvement Cost: $18,000,  Total Project Cost: $275,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 7606A,  Location: 0.4 N JCT SR 181 (Lat: 47.465000,  Lng: -122.240000),  Route carried "on" structure: Interstate 405,  Year Built: 1965,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 23.32m (76.51ft),  Average Daily Traffic: 139,576 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 170,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: BNSF & UP RR & SW 16TH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.830,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 35.7m (117.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 35.3m (115.8ft),  Out-to-Out Width: 35.7m (117.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2008,  Bridge Improvement Cost: $562,000,  Roadway Improvement Cost: $56,000,  Total Project Cost: $843,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 7623A,  Location: 2.0 N JCT SR 900 (Lat: 47.531600,  Lng: -122.197750),  Route carried "on" structure: City street 405,  Year Built: 1965,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 4,460 (year 1994),  Truck Traffic: 8%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20,  Features Intersected: I-405,  Facility Carried by Structure: NE 44TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.020,  Lanes on structure: 3,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 55.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $97,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $146,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 7828A,  Location: JCT SR 900 (Lat: 47.501667,  Lng: -122.195000),  Route carried "on" structure: Interstate 405,  Year Built: 1966,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 61,700 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 75,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: SR 900 0C N RENTON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.690,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 16.9m (55.4ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $93,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $140,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 7828B,  Location: JCT SR 900 (Lat: 47.336667,  Lng: -122.195000),  Route carried "on" structure: Interstate 405,  Year Built: 1966,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 6.55m (21.49ft),  Average Daily Traffic: 61,700 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 75,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: SR 900 0C N RENTON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.690,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.0m (105.0ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Bridge Improvement Cost: $93,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $140,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 8054A,  Location: 0.3 E JCT I-405 (Lat: 47.501028,  Lng: -122.191000),  Route carried "on" structure: City street 900,  Year Built: 1967,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 13,000 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20,  Features Intersected: SR 900,  Facility Carried by Structure: ABERDEEN AVE NE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.610,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.3m (96.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2008,  Bridge Improvement Cost: $71,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $107,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 11976A,  Location: 1.1 N JCT SR 900 (Lat: 47.518528,  Lng: -122.198833),  Route carried "on" structure: City street 405,  Year Built: 1981,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 6,500 (year 1994),  Truck Traffic: 8%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20+Mod,  Features Intersected: SR 405,  Facility Carried by Structure: N 30TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.470,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.8m (45.3ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $62,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $93,000 ( Estimate for 2006),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 13354B,  Location: 0.6 N JCT SR 181 (Lat: 47.466139,  Lng: -122.233333),  Route carried "on" structure: Interstate 405,  Year Built: 1990,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 139,576 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 170,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: OVERFLOW CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.560,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 32.8m (107.6ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 75.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006
Find on map >>

Structure Number: 13354C,  Location: 0.7 N JCT SR 181 (Lat: 47.466111,  Lng: -122.116667),  Route carried "on" structure: Interstate 405,  Year Built: 1990,  Status: Open,  Structure Length: 2.35m (7.71ft),  Average Daily Traffic: 139,576 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 170,300 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: OAKESDALE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.590,  Lanes on structure: 6,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.6m (74.1ft),  Curb-To-Curb Width: 32.9m (107.9ft),  Out-to-Out Width: 33.4m (109.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 63.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2006,  Bridge Improvement Cost: $77,000,  Roadway Improvement Cost: $8,000,  Total Project Cost: $116,000 ( Estimate for 2006),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 13354D,  Location: 1.1 N JCT SR 181 (Lat: 47.468333,  Lng: -122.223333),  Route carried "on" structure: City street 405,  Year Built: 1990,  Status: Open,  Structure Length: 6.71m (22.01ft),  Average Daily Traffic: 16,016 (year 1994),  Truck Traffic: 8%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20+Mod,  Features Intersected: I-405,  Facility Carried by Structure: LIND AVE (88TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.310,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.2m (108.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 19.2m (63.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 88.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $116,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $174,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052A,  Location: 1.3 N JCT SR 167 (Lat: 47.480000,  Lng: -122.200000),  Route carried "on" structure: Interstate 405,  Year Built: 1993,  Status: Open,  Structure Length: 16.09m (52.79ft),  Average Daily Traffic: 54,900 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 67,000 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.650,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 59.7m (195.9ft),  Curb-To-Curb Width: 23.1m (75.8ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Bridge Improvement Cost: $351,000,  Roadway Improvement Cost: $35,000,  Total Project Cost: $527,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052B,  Location: 1.3 N JCT SR 167 (Lat: 47.480000,  Lng: -122.201028),  Route carried "on" structure: Interstate 405,  Year Built: 1994,  Status: Open,  Structure Length: 17.01m (55.81ft),  Average Daily Traffic: 54,900 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 67,000 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: CEDAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.650,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 59.4m (194.9ft),  Curb-To-Curb Width: 18.5m (60.7ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Bridge Improvement Cost: $300,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $450,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052D,  Location: 1.3 N JCT SR 167 (Lat: 47.480000,  Lng: -122.200000),  Route carried "on" structure: City street 405,  Year Built: 1994,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 15,267 (year 1993),  Truck Traffic: 8%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20+Mod,  Features Intersected: SR 405,  Facility Carried by Structure: RENTON AVE S
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.630,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 0.0m,  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $50,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $75,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052E,  Location: 1.2 N JCT SR 167 (Lat: 47.480000,  Lng: -122.200000),  Route carried "on" structure: City street 405,  Year Built: 1993,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 104,000 (year 1994),  Truck Traffic: 2%,  Average Future Daily Traffic: 999,999 ,  Design Load: HS 20+Mod,  Features Intersected: I-405,  Facility Carried by Structure: CEDAR AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.490,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 0.0m,  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $51,000,  Roadway Improvement Cost: $5,000,  Total Project Cost: $77,000 ( Estimate for 2006),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052F,  Location: 1.7 N JCT SR 167 (Lat: 47.485000,  Lng: -122.195000),  Route carried "on" structure: Interstate 405,  Year Built: 1994,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 109,749 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 133,900 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: SR 169
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 6.470,  Lanes on structure: 7,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 40.2m (131.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.1m (115.2ft),  Curb-To-Curb Width: 40.2m (131.9ft),  Out-to-Out Width: 41.9m (137.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $116,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $174,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14052G,  Location: 0.2 N JCT SR 169 (Lat: 47.486667,  Lng: -122.193333),  Route carried "on" structure: Interstate 405,  Year Built: 1994,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 109,749 (year 2006),  Truck Traffic: 6%,  Average Future Daily Traffic: 133,900 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: NE 3RD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.740,  Lanes on structure: 7,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 43.9m (144.0ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 43.9m (144.0ft),  Out-to-Out Width: 45.4m (149.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2007,  Bridge Improvement Cost: $110,000,  Roadway Improvement Cost: $11,000,  Total Project Cost: $165,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 14756A,  Location: JCT I-405 (Lat: 47.501667,  Lng: -122.196667),  Route carried "on" structure: Ramp State highway 900,  Year Built: 1997,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 8,400 (year 2002),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,484 ,  Design Load: HS 25,  Features Intersected: SR 900
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.690,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $73,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $110,000 ( Estimate for 2008),  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 16145A,  Location: 1.3 N JCT SR 181 (Lat: 47.468611,  Lng: -122.216389),  Route carried "on" structure: Ramp Interstate 405,  Year Built: 2002,  Status: Open,  Structure Length: 15.39m (50.49ft),  Average Daily Traffic: 14,800 (year 2003),  Truck Traffic: 2%,  Average Future Daily Traffic: 14,948 ,  Design Load: HS 25,  Features Intersected: SR 167, RAMP,  Facility Carried by Structure: S-S RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.700,  Lanes on structure: 1,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 48.2m (158.1ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 87.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Bridge Improvement Cost: $151,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $227,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 85182,  Location: 00.61 S. JCT.SR 900 (Lat: 47.474900,  Lng: -122.248033),  Route carried "on" structure: City street 46030,  Year Built: 1998,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 10,555 (year 2003),  Truck Traffic: 12%,  Average Future Daily Traffic: 14,777 ,  Design Load: HS 25,  Features Intersected: BLACK RIVER CHANNEL,  Facility Carried by Structure: MONSTER ROAD SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.090,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 84.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.88m (16.01ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2008,  Bridge Improvement Cost: $64,000,  Roadway Improvement Cost: $6,000,  Total Project Cost: $96,000 ( Estimate for 2008),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 85258,  Location: 0.11 N SR 900 (Lat: 47.483472,  Lng: -122.205264),  Route carried "on" structure: City street 51010,  Year Built: 1987,  Status: Open,  Structure Length: 4.21m (13.81ft),  Average Daily Traffic: 2,319 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,266 ,  Design Load: HS 20,  Features Intersected: CEDAR RIVER,  Facility Carried by Structure: WELLS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.970,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 85263,  Location: 0.2M NORTH SR 900 (Lat: 47.484317,  Lng: -122.206325),  Route carried "on" structure: City street 52510,  Year Built: 1954,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 1,399 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,970 (year 2030),  Design Load: H 15,  Features Intersected: CEDAR RIVER,  Facility Carried by Structure: WILLIAMS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.090,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 29.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.72m (15.49ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2008,  Critical Feature Inspection Date: August 2008,  Bridge Improvement Cost: $30,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $45,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 85281,  Location: .42 E JCT SR 167 (Lat: 47.485072,  Lng: -122.208700),  Route carried "on" structure: City street 21020,  Year Built: 1973,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 28,112 (year 2003),  Truck Traffic: 3%,  Average Future Daily Traffic: 39,357 ,  Design Load: HS 20,  Features Intersected: Cedar River,  Facility Carried by Structure: Logan Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.450,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 17.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 85423,  Location: 0.7M EAST SR 181 (Lat: 47.467772,  Lng: -122.233528),  Route carried "on" structure: City street 42020,  Year Built: 1987,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 35,590 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 50,124 ,  Design Load: HS 20,  Features Intersected: SPRINGBROOK CREEK,  Facility Carried by Structure: SW GRADY WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.090,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 59.7m (195.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $28,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $42,000 ( Estimate for 2006)
Find on map >>

Structure Number: 85443,  Location: 0.2 MI WEST LIND AVE SW (Lat: 47.455611,  Lng: -122.227500),  Route carried "on" structure: City street 1070,  Year Built: 2000,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,568 (year 2007),  Truck Traffic: 18%,  Average Future Daily Traffic: 3,617 ,  Design Load: HS 20,  Features Intersected: SPRINGBROOK CREEK,  Facility Carried by Structure: SW 27TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1608.970,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 27.9m (91.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.82m (2.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $14,000 ( Estimate for 2006),  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 85521,  Location: 0.6 MI SOUTH OF I-405 (Lat: 47.458953,  Lng: -122.223583),  Route carried "on" structure: City street 1070,  Year Built: 1981,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 9,390 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 13,225 ,  Features Intersected: P9 CHANNEL/PANTHER CREEK,  Facility Carried by Structure: LIND AVE SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.270,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $13,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $20,000 ( Estimate for 2006)
Find on map >>

Structure Number: 85573,  Location: 1.MILE S.OF I-405 (Lat: 47.525000,  Lng: -122.195000),  Route carried "on" structure: City street 1070,  Year Built: 1950,  Year Reconstructed: 1978,  Status: Posted for load,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 105 (year 2008),  Truck Traffic: 3%,  Average Future Daily Traffic: 250 (year 2028),  Design Load: H 20,  Features Intersected: MAY CREEK,  Facility Carried by Structure: JONES AVE NE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.450,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Very good,  Operating Rating: 25.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 14.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.98m (3.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2008,  Bridge Improvement Cost: $123,000,  Roadway Improvement Cost: $12,000,  Total Project Cost: $185,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 85617,  Location: 1.0 MI WEST SR 167 (Lat: 47.441197,  Lng: -122.239044),  Route carried "on" structure: City street 41020,  Year Built: 1983,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 34,279 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 48,270 ,  Features Intersected: SPRINGBROOK CREEK,  Facility Carried by Structure: SW 43RD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.090,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.85m (2.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007
Find on map >>

Structure Number: 85618,  Location: 0.25 MI NORTH SW 43 ST (Lat: 47.443847,  Lng: -122.232975),  Route carried "on" structure: City street 1070,  Year Built: 1979,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 10,143 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 14,285 ,  Features Intersected: SPRINGBROOK CREEK,  Facility Carried by Structure: OAKESDALE AVE SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.180,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007
Find on map >>

Structure Number: 85706,  Location: 1.1 MILE NORTH I405 (Lat: 47.473458,  Lng: -122.238119),  Route carried "on" structure: City street 1070,  Year Built: 1987,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 9,211 (year 1998),  Truck Traffic: 11%,  Average Future Daily Traffic: 12,895 ,  Design Load: HS 20,  Features Intersected: BLACK RIVER DRAIN,  Facility Carried by Structure: OAKESDALE AVE SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 96.540,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 65.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.88m (19.29ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $74,000,  Roadway Improvement Cost: $7,000,  Total Project Cost: $111,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 85843,  Location: 0.1M E OF I 405 (Lat: 47.481111,  Lng: -122.200000),  Route carried "on" structure: City street 1169,  Year Built: 1960,  Status: Open,  Structure Length: 4.30m (14.11ft),  Average Daily Traffic: 16,138 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 22,730 (year 2030),  Design Load: H 15,  Features Intersected: CEDAR RIVER,  Facility Carried by Structure: HOUSER WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.001,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.30m (14.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2008,  Bridge Improvement Cost: $32,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $48,000 ( Estimate for 2008),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 85844,  Location: 0.5 M WEST LIND (Lat: 47.465911,  Lng: -122.232836),  Route carried "on" structure: City street 49020,  Year Built: 1991,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 2,473 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,462 ,  Design Load: HS 20,  Features Intersected: SPRINGBROOK CREEK,  Facility Carried by Structure: SW 16TH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.090,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 33.3 metric tons,  Inventory Rating: 23.4 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 86035,  Location: 0.2 E JCT SR 167 (Lat: 47.441394,  Lng: -122.215169),  Route carried "on" structure: City street 1070,  Year Built: 1992,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 43,752 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 61,253 ,  Design Load: H 20,  Features Intersected: HOSPITAL ACCESS ROAD,  Facility Carried by Structure: SOUTH 43RD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 112.630,  Lanes on structure: 6,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 32.0m (105.0ft)

Condition: Culverts: Good,  Operating Rating: 59.4 metric tons,  Inventory Rating: 36.0 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007
Find on map >>

Structure Number: 86322,  Location: 0.2 SW FAI 405 (Lat: 47.529789,  Lng: -122.201083),  Route carried "on" structure: City street 25010,  Year Built: 1996,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 5,725 (year 2003),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,015 ,  Design Load: HS 25,  Features Intersected: MAY CREEK,  Facility Carried by Structure: LAKE WASHINGTON BL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.090,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 81.9 metric tons,  Inventory Rating: 48.6 metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2008,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 87059,  Location: 0.5 M. WEST OF LIND AVE. (Lat: 47.465911,  Lng: -122.232836),  Route carried "on" structure: City street 1070,  Year Built: 1998,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 6,917 (year 2003),  Truck Traffic: 9%,  Average Future Daily Traffic: 9,684 ,  Design Load: HS 25,  Features Intersected: Springbrook Creek,  Facility Carried by Structure: Oakesdale Avenue S
Minimum Vertical Clearance: 32.69m (107.25ft),  Kilometerpoint: 14.480,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.8m (137.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Bridge Improvement Cost: $174,000,  Roadway Improvement Cost: $17,000,  Total Project Cost: $261,000 ( Estimate for 2003),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 6424A,  Location: 0.6 N JCT I-405 (Lat: 47.473333,  Lng: -122.213333),  Route carried "under" structure: State highway 167,  Year Built: 1925,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 71,255 (year 2002),  Truck Traffic: 10%,  Features Intersected: STATE ROUTE 167,  Facility Carried by Structure: CMSTPP RR
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 4.328,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)


Parts: 1, 2

Discuss this city on our hugely popular Washington forum

Back to: Renton, WA, Washington, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.