National Bridge Inventory (NBI) Statistics
Number of bridges: 46
Total length: 473 meters (1,552ft)
Total costs: $12,678,000
Total average daily traffic: 1,465,672
Total average daily truck traffic: 71,795
National Bridge Inventory (NBI) Registered Bridges for Ridgefield Park

New bridges - Historical Statistics

  • 1920-1929: 1
  • 1930-1939: 2
  • 1940-1949: 0
  • 1950-1959: 3
  • 1960-1969: 2
  • 1970-1979: 37
  • 1980-1989: 1

Reconstructed bridges - Historical Statistics

  • 1970-1979: 1
  • 1980-1989: 0
  • 1990-1999: 0
  • 2000-2009: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Find on map >>

Structure Number: 20049A,  Location: 0.2 MI EAST OF I-95 (Lat: 40.838617,  Lng: -74.017067),  Route carried "on" structure: County highway 124,  Year Built: 1971,  Status: Open,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 27,744 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 33,558 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: OVERPECK CREEK,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.127,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Good,  Operating Rating: 78.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 10.80m (35.43ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2006,  Underwater Inspection Date: May 2004,  Bridge Improvement Cost: $1,300,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $1,500,000 ( Estimate for 2004),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 20050A,  Location: 0.2 MILE EAST OF I95 NJTP (Lat: 40.853333,  Lng: -74.011667),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 525 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 656 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: TEANECK CREEK,  Facility Carried by Structure: CHALLENGER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.0m (23.0ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 65.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2006,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 221156,  Location: 0.3 MILES WEST OF RT I-95 (Lat: 40.848453,  Lng: -74.021892),  Route carried "on" structure: US 46,  Year Built: 1934,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 44,540 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 53,448 (year 2026),  Features Intersected: CR 39 (TEANECK ROAD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 113.748,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $1,000,  Roadway Improvement Cost: $30,000,  Total Project Cost: $42,000 ( Estimate for 2004),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 22215,  Location: .2 MI E OF NJ TURNPIKE (Lat: 40.844964,  Lng: -74.028247),  Route carried "on" structure: US 46,  Year Built: 1928,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 15.54m (50.98ft),  Average Daily Traffic: 82,610 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 99,132 (year 2027),  Features Intersected: OVERPECK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 114.762,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.5m (86.9ft),  Skew: 30 degrees,  Navigation Control: Yes ( Vertical Clearance: 2.7m (8.9ft), Horizontal Clearance: 21.3m (69.9ft)),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 26.5m (86.9ft),  Out-to-Out Width: 33.2m (108.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 15.54m (50.98ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Critical Feature Inspection Date: June 2007,  Underwater Inspection Date: November 2006,  Bridge Improvement Cost: $5,000,  Total Project Cost: $6,000 ( Estimate for 2005),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 226165,  Location: 0.8MI W.OF I-80/I-95 JCT. (Lat: 40.867153,  Lng: -74.029711),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 8,770 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 10,530 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: ROUTE I-80,  Facility Carried by Structure: SECOND ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.4m (93.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 22916,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.847117,  Lng: -74.019253),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1973,  Status: Open,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 7,845 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 9,415 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: US 46
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.372,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: E11642,  Location: 3.0 MI NORTH OF INTER 17E (Lat: 40.830000,  Lng: -74.025000),  Route carried "on" structure: Interstate 95,  Year Built: 1950,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 32.95m (108.10ft),  Average Daily Traffic: 78,622 (year 2006),  Truck Traffic: 15%,  Average Future Daily Traffic: 102,806 (year 2026),  Design Load: HS 20,  Features Intersected: SUSQUEHANNA RR,NJTPK SA,  Facility Carried by Structure: NJ TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 187.360,  Lanes on structure: 6,  Lanes under structure: 3,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 40.5m (132.9ft),  Skew: 22 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 40.7m (133.5ft),  Out-to-Out Width: 42.6m (139.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11727,  Location: 1.6 NI N HACKENSACK RIVER (Lat: 40.841667,  Lng: -74.018333),  Route carried "on" structure: County highway 124,  Year Built: 1970,  Status: Open,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 7,880 (year 2005),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,638 (year 2025),  Design Load: HS 20,  Features Intersected: NJTPK SN80&95, NS80&95,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.448,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Toll Authority,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.7m (90.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: M11763C,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 8,714 (year 2005),  Truck Traffic: 15%,  Average Future Daily Traffic: 11,764 (year 2025),  Design Load: HS 20,  Features Intersected: NJ TPK RAMP L,  Facility Carried by Structure: NJ TPK RAMP WT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.194,  Lanes on structure: 1,  Lanes under structure: 1,  Owner: State Toll Authority,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11767I,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 74,994 (year 2005),  Truck Traffic: 15%,  Average Future Daily Traffic: 101,242 (year 2025),  Design Load: HS 20,  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJ TPK SN-80
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.371,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.00m (36.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $3,700,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $4,750,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11767N,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 74,994 (year 2005),  Truck Traffic: 15%,  Average Future Daily Traffic: 101,242 (year 2025),  Design Load: HS 20,  Features Intersected: US 46&RAMPS L,N,ET,& E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 16.2m (53.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 34.8m (114.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11767O,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "on" structure: Interstate 80,  Year Built: 1970,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 74,994 (year 2005),  Truck Traffic: 10%,  Average Future Daily Traffic: 101,242 (year 2025),  Design Load: H 20,  Features Intersected: US ROUTE 46
Minimum Vertical Clearance: 0.31m (1.02ft),  Kilometerpoint: 116.372,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.5m (132.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11767S,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "on" structure: Interstate 95,  Year Built: 1970,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 74,994 (year 2005),  Truck Traffic: 10%,  Average Future Daily Traffic: 101,242 (year 2025),  Design Load: H 20,  Features Intersected: US ROUTE 46
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Toll Authority,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 20.4m (66.9ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.00m (36.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $5,000,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $6,380,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "on" structure: Ramp Interstate 95,  Year Built: 1972,  Status: Open,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 5,080 (year 2007),  Truck Traffic: 15%,  Average Future Daily Traffic: 6,198 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 14,  Owner: State Toll Authority,  Maintenance Responsibility: Private,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 43.0m (141.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 221156,  Location: 0.3 MILES WEST OF RT I-95 (Lat: 40.848453,  Lng: -74.021892),  Route carried "under" structure: County highway 39,  Year Built: 1934,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 2,102 (year 2006),  Truck Traffic: 4%,  Features Intersected: CR 39 (TEANECK ROAD),  Facility Carried by Structure: ROUTE U.S.46
Minimum Vertical Clearance: 4.32m (14.17ft),  Kilometerpoint: 0.644,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>

Structure Number: 226165,  Location: 0.8MI W.OF I-80/I-95 JCT. (Lat: 40.867153,  Lng: -74.029711),  Route carried "under" structure: Interstate 80,  Year Built: 1963,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 166,280 (year 2006),  Features Intersected: ROUTE I-80,  Facility Carried by Structure: SECOND ST
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 10.818,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.4m (93.2ft)

Find on map >>

Structure Number: 22916,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.847117,  Lng: -74.019253),  Route carried "under" structure: US 46,  Year Built: 1973,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 51,340 (year 2007),  Truck Traffic: 4%,  Features Intersected: US 46,  Facility Carried by Structure: RAMP N (I95)
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 113.973,  Lanes on structure: 1,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>

Structure Number: E11642,  Location: 3.0 MI NORTH OF INTER 17E (Lat: 40.830000,  Lng: -74.025000),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1950,  Structure Length: 32.95m (108.10ft),  Average Daily Traffic: 1,571 (year 2006),  Features Intersected: SUSQUEHANNA RR,NJTPK SA,  Facility Carried by Structure: NJ TURNPIKE
Minimum Vertical Clearance: 5.39m (17.68ft),  Kilometerpoint: 18.736,  Lanes on structure: 6,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.8m (124.0ft)

Find on map >>

Structure Number: E11642,  Location: 3.0 MI NORTH OF INTER 17E (Lat: 40.830000,  Lng: -74.025000),  Route carried "under" structure: Other road ,  Year Built: 1950,  Structure Length: 32.95m (108.10ft),  Average Daily Traffic: 1,434 (year 2006),  Features Intersected: SUSQUEHANNA RR,NJTPK SA,  Facility Carried by Structure: NJ TURNPIKE
Minimum Vertical Clearance: 6.93m (22.74ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.8m (124.0ft)

Find on map >>

Structure Number: M11727,  Location: 1.6 NI N HACKENSACK RIVER (Lat: 40.841667,  Lng: -74.018333),  Route carried "under" structure: County highway 124,  Year Built: 1970,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 74,994 (year 2005),  Features Intersected: NJTPK SN80&95, NS80&95,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 1.448,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>

Structure Number: M11727,  Location: 1.6 NI N HACKENSACK RIVER (Lat: 40.841667,  Lng: -74.018333),  Route carried "under" structure: Interstate 95,  Year Built: 1970,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 74,994 (year 2005),  Features Intersected: NJTPK SN80&95, NS80&95,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 11.576,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>

Structure Number: M11727,  Location: 1.6 NI N HACKENSACK RIVER (Lat: 40.841667,  Lng: -74.018333),  Route carried "under" structure: Interstate 95,  Year Built: 1970,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 74,994 (year 2005),  Features Intersected: NJTPK SN80&95, NS80&95,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 0.54m (1.77ft),  Kilometerpoint: 11.576,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>

Structure Number: M11727,  Location: 1.6 NI N HACKENSACK RIVER (Lat: 40.841667,  Lng: -74.018333),  Route carried "under" structure: Interstate 95,  Year Built: 1970,  Structure Length: 10.06m (33.01ft),  Average Daily Traffic: 74,994 (year 2005),  Features Intersected: NJTPK SN80&95, NS80&95,  Facility Carried by Structure: BERGEN TURNPIKE
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 11.576,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.7m (90.9ft)

Find on map >>

Structure Number: M11763C,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 3.54m (11.61ft),  Average Daily Traffic: 7,036 (year 2005),  Features Intersected: NJ TPK RAMP L,  Facility Carried by Structure: NJ TPK RAMP WT
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 116.194,  Lanes on structure: 1,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>

Structure Number: M11767I,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: US 46,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 44,550 (year 2005),  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJ TPK SN-80
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 114.215,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767I,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJ TPK SN-80
Minimum Vertical Clearance: 0.49m (1.61ft),  Kilometerpoint: 116.371,  Lanes on structure: 2,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767I,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJ TPK SN-80
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 116.371,  Lanes on structure: 2,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767I,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJ TPK SN-80
Minimum Vertical Clearance: 5.52m (18.11ft),  Kilometerpoint: 116.371,  Lanes on structure: 2,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767N,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: US 46,  Year Built: 1970,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 44,550 (year 2005),  Features Intersected: US 46&RAMPS L,N,ET,& E,  Facility Carried by Structure: NJ TPK SN-95
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 114.215,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: M11767N,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US 46&RAMPS L,N,ET,& E
Minimum Vertical Clearance: 5.19m (17.03ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: M11767N,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US 46&RAMPS L,N,ET,& E
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: M11767N,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 9.30m (30.51ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US 46&RAMPS L,N,ET,& E
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.8m (114.2ft)

Find on map >>

Structure Number: M11767O,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: US 46,  Year Built: 1970,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 44,550 (year 2005),  Truck Traffic: 5%,  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJTPK NS80
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 114.215,  Lanes on structure: 3,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>

Structure Number: M11767O,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 1,937 (year 2005),  Truck Traffic: 9%,  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJTPK NS80
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>

Structure Number: M11767O,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 1,937 (year 2005),  Truck Traffic: 9%,  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJTPK NS80
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>

Structure Number: M11767O,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 1,937 (year 2005),  Truck Traffic: 9%,  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJTPK NS80
Minimum Vertical Clearance: 5.74m (18.83ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>

Structure Number: M11767S,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: US 46,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 44,550 (year 2005),  Features Intersected: US ROUTE 46,  Facility Carried by Structure: NJTPK NS 95
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 189.372,  Lanes on structure: 3,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767S,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767S,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11767S,  Location: 1.9 MI N HACKENSACK RIVER (Lat: 40.846667,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1970,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 1,937 (year 2005),  Features Intersected: US ROUTE 46
Minimum Vertical Clearance: 5.74m (18.83ft),  Kilometerpoint: 116.371,  Lanes on structure: 3,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Interstate 95,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 73,774 (year 2007),  Truck Traffic: 10%,  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 116.645,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 6,981 (year ),  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Ramp Interstate 95,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 7,879 (year ),  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Interstate 95,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 35,233 (year ),  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 189.629,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Ramp US 46,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 37,191 (year ),  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 189.629,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>

Structure Number: M11783,  Location: 1 MI SOUTH OF I-80 JCT (Lat: 40.848333,  Lng: -74.018333),  Route carried "under" structure: Ramp City street ,  Year Built: 1972,  Structure Length: 13.81m (45.31ft),  Average Daily Traffic: 1,125 (year ),  Features Intersected: NJTP & I-80,  Facility Carried by Structure: EMERSON STREET
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 189.629,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 43.0m (141.1ft)