U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Rochelle, Illinois (IL) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Rochelle, IL, Illinois, Illinois forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 42
Total length: 260 meters (853ft)
Total average daily traffic: 252,529
Total average daily truck traffic: 59,569
National Bridge Inventory (NBI) Registered Bridges for Rochelle

New bridges - Historical Statistics

  • 1920-1929: 1
  • 1930-1939: 0
  • 1940-1949: 0
  • 1950-1959: 1
  • 1960-1969: 4
  • 1970-1979: 15
  • 1980-1989: 12
  • 1990-1999: 4
  • 2000-2009: 5

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 71000316084,  Location: 0.3 MI S JCT ILL 38 (Lat: 41.917778,  Lng: -89.068661),  Route carried "on" structure: State highway 251,  Year Built: 1928,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 9,900 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 11,000 (year 2025),  Design Load: HS 20,  Features Intersected: KYTE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 149.090,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 74.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 71005828626,  Location: 2 MI E OF ROCHELLE (Lat: 41.934511,  Lng: -89.023922),  Route carried "on" structure: State highway 38,  Year Built: 1980,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 4,050 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,200 (year 2021),  Design Load: HS 20,  Features Intersected: I-39 & US 51
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.985,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.2m (105.6ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71006128627,  Location: 1.5 MI E OF ROCHELLE (Lat: 41.920039,  Lng: -89.023761),  Route carried "on" structure: Other road 5447,  Year Built: 1980,  Status: Open,  Structure Length: 7.96m (26.12ft),  Average Daily Traffic: 700 (year 2007),  Truck Traffic: 22%,  Average Future Daily Traffic: 725 (year 2021),  Design Load: HS 20,  Features Intersected: I-39 & US 51,  Facility Carried by Structure: CRESTON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.409,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71006210437,  Location: 1 MI N OF LEE CO.LN. (Lat: 41.904939,  Lng: -89.021722),  Route carried "on" structure: Interstate 39,  Year Built: 1981,  Status: Open,  Structure Length: 8.48m (27.82ft),  Average Daily Traffic: 13,650 (year 2007),  Truck Traffic: 40%,  Average Future Daily Traffic: 11,500 (year 2021),  Design Load: HS 20,  Features Intersected: I-88(E-W TOLLWAY)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 157.746,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 16.1m (52.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 41.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71006310454,  Location: 1 MI N OF LEE CO.LN. (Lat: 41.904969,  Lng: -89.020822),  Route carried "on" structure: Interstate 39,  Year Built: 1981,  Status: Open,  Structure Length: 8.48m (27.82ft),  Average Daily Traffic: 8,700 (year 2007),  Truck Traffic: 45%,  Average Future Daily Traffic: 11,500 (year 2021),  Design Load: HS 20,  Features Intersected: I-88(E-W TOLLWAY)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 157.730,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 32.7m (107.3ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.7m (51.5ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 43.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71006604651,  Location: IN ROCHELLE (Lat: 41.921597,  Lng: -89.068753),  Route carried "on" structure: State highway 251,  Year Built: 1981,  Status: Open,  Structure Length: 30.18m (99.02ft),  Average Daily Traffic: 9,900 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 11,100 (year 2026),  Design Load: HS 20,  Features Intersected: IL38,CNW&BN RR&1 AVE
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 149.557,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 15,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2008,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 7100710175,  Location: .4 MI E OF ILL 251 (Lat: 41.934008,  Lng: -89.060639),  Route carried "on" structure: State highway 38,  Year Built: 1983,  Status: Open,  Structure Length: 3.20m (10.50ft),  Average Daily Traffic: 5,000 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,600 (year 2026),  Design Load: HS 20,  Features Intersected: KYTE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 43.041,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.2m (66.3ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 65.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 71008529631,  Location: 0.6 MI. N. OF IL 38 (Lat: 41.944117,  Lng: -89.067431),  Route carried "on" structure: State highway 251,  Year Built: 1996,  Status: Open,  Structure Length: 2.24m (7.35ft),  Average Daily Traffic: 9,100 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,200 (year 2020),  Design Load: HS 20,  Features Intersected: KYTE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 152.051,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 24.8m (81.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 71201510648,  Location: 1.20 MI S OF IL 38 (Lat: 41.909764,  Lng: -89.022725),  Route carried "on" structure: Interstate 39,  Year Built: 1981,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 27,300 (year 2007),  Truck Traffic: 40%,  Average Future Daily Traffic: 57,900 (year 2024),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 158.342,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 74.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2007
Find on map >>

Structure Number: 71202029634,  Location: 0.5 MI E OF ROCHELLE (Lat: 41.934228,  Lng: -89.046053),  Route carried "on" structure: State highway 38,  Year Built: 1996,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 4,800 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 6,700 (year 2020),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 44.231,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2006
Find on map >>

Structure Number: 71319316363,  Location: 3.5 S.W. ROCHELLE (Lat: 41.891331,  Lng: -89.112028),  Route carried "on" structure: City street 4300,  Year Built: 1962,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 25 (year 2003),  Average Future Daily Traffic: 25 (year 2026),  Design Load: HS 15,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: BRUSH GROVE RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.381,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 33.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 71331432651,  Location: N EDGE ROCHELLE (Lat: 41.941214,  Lng: -89.063397),  Route carried "on" structure: Other road 5438,  Year Built: 1997,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 2,550 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,850 (year 2025),  Design Load: HS 20,  Features Intersected: KYTE RIVER,  Facility Carried by Structure: FLAGG ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.462,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.7m (61.4ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 716000155,  Location: LAKEVIEW DRIVE (Lat: 41.915233,  Lng: -89.072511),  Route carried "on" structure: City street 3300,  Year Built: 1963,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 1,850 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,850 (year 2025),  Design Load: HS 15,  Features Intersected: KYTE CREEK,  Facility Carried by Structure: LAKEVIEW DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.402,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>

Structure Number: 71600115626,  Location: ROCHELLE (Lat: 41.913053,  Lng: -89.074017),  Route carried "on" structure: City street 3600,  Year Built: 1950,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 25 (year 1998),  Average Future Daily Traffic: 25 (year 2025),  Features Intersected: KYTE CREEK,  Facility Carried by Structure: TREATMENT PLANT RO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.9m (22.6ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Good,  Channel: Very good,  Operating Rating: 28.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 71600516137,  Location: ROCHELLE (Lat: 41.926147,  Lng: -89.058572),  Route carried "on" structure: Other road 5444,  Year Built: 1966,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 1,800 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,500 (year 2023),  Features Intersected: KYTE CREEK,  Facility Carried by Structure: SEVENTH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.821,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 33.3 metric tons,  Inventory Rating: 24.3 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 7160061644,  Location: ROCHELLE (Lat: 41.930353,  Lng: -89.059797),  Route carried "on" structure: City street 1900,  Year Built: 1965,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 1,400 (year 2003),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,400 (year 2025),  Design Load: HS 20,  Features Intersected: KYTE CREEK,  Facility Carried by Structure: SCHOOL AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 71600708301,  Location: ROCHELLE S 2ND ST (Lat: 41.918981,  Lng: -89.062525),  Route carried "on" structure: City street 7410,  Year Built: 1975,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 79 (year 1998),  Average Future Daily Traffic: 100 (year 2023),  Design Load: HS 20,  Features Intersected: KYTE CREEK,  Facility Carried by Structure: SO SECOND STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 71600808265,  Location: CARON RD ROCHELLE (Lat: 41.922633,  Lng: -89.054361),  Route carried "on" structure: Other road 5458,  Year Built: 1977,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 1,700 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 4,500 (year 2023),  Design Load: HS 20,  Features Intersected: BRANCH OF KYTE CREEK,  Facility Carried by Structure: CARON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.043,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2003
Find on map >>

Structure Number: 71600927808,  Location: ROCHELLE 1ST. AVE. (Lat: 41.919606,  Lng: -89.058136),  Route carried "on" structure: Other road 5447,  Year Built: 1978,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 2,800 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,500 (year 2023),  Design Load: HS 20,  Features Intersected: KYTE CREEK,  Facility Carried by Structure: FIRST AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.593,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 71601025357,  Location: IN ROCHELLE (Lat: 41.918444,  Lng: -89.064075),  Route carried "on" structure: Other road 5456,  Year Built: 1990,  Status: Open,  Structure Length: 2.75m (9.02ft),  Average Daily Traffic: 3,000 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,000 (year 2023),  Design Load: HS 20,  Features Intersected: KYTE CREEK,  Facility Carried by Structure: SOUTH MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.191,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2003,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Structure Number: 716011363,  Location: SW SEC 20 T40N R2E,  Route carried "on" structure: City street 8700,  Year Built: 2001,  Status: Open,  Structure Length: 6.72m (22.05ft),  Average Daily Traffic: 3,000 (year 2003),  Average Future Daily Traffic: 6,290 (year 2020),  Design Load: HS 20,  Features Intersected: UP RR & RILEY DITCH,  Facility Carried by Structure: DEMENT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.110,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.9m (42.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Structure Number: 71601236301,  Location: SW SEC 20 T40N R2E,  Route carried "on" structure: City street 8700,  Year Built: 2001,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 3,000 (year 2003),  Average Future Daily Traffic: 6,290 (year 2020),  Design Load: HS 20,  Features Intersected: RILEY DITCH,  Facility Carried by Structure: DEMENT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.142,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.9m (42.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Excellent,  Culverts: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2003
Find on map >>

Structure Number: 71601339012,  Location: EAST EDGE ROCHELLE (Lat: 41.919675,  Lng: -89.053011),  Route carried "on" structure: Other road 5447,  Year Built: 2004,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 2,850 (year 2007),  Truck Traffic: 34%,  Average Future Daily Traffic: 3,420 (year 2028),  Design Load: HS 20,  Features Intersected: RYLEY DITCH,  Facility Carried by Structure: FIRST AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.011,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.2m (23.6ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006
Structure Number: 7160143385,  Location: S SIDE OF ROCHELLE,  Route carried "on" structure: City street 4300,  Year Built: 2003,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 1,250 (year 2005),  Truck Traffic: 62%,  Average Future Daily Traffic: 2,800 (year 2023),  Design Load: HS 20,  Features Intersected: KYTE RIVER,  Facility Carried by Structure: INTERMODEL DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.368,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Structure Number: 71601534205,  Location: SW SIDE OF ROCHELLE,  Route carried "on" structure: City street 4300,  Year Built: 2003,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 1,250 (year 2005),  Truck Traffic: 62%,  Average Future Daily Traffic: 2,800 (year 2023),  Design Load: HS 20,  Features Intersected: FLAGG TRIB,  Facility Carried by Structure: INTERMODAL DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.821,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2004,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 71991323083,  Location: .5 MI S ROCHELLE (Lat: 41.900181,  Lng: -89.068203),  Route carried "on" structure: Interstate 88,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 6,500 (year 2006),  Truck Traffic: 22%,  Average Future Daily Traffic: 9,500 (year 2020),  Design Load: HS 20,  Features Intersected: ILL 251
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 122.284,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Precast Panels
Find on map >>

Structure Number: 71991423082,  Location: .5 MI S ROCHELLE (Lat: 41.900456,  Lng: -89.068200),  Route carried "on" structure: Interstate 88,  Year Built: 1974,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 7,450 (year 2006),  Truck Traffic: 22%,  Average Future Daily Traffic: 9,500 (year 2020),  Design Load: HS 20,  Features Intersected: ILL 251
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 122.300,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 35.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2006,  Deck Structure Type: Concrete Precast Panels
Find on map >>

Structure Number: 71991523081,  Location: .7 MI E OF ILL 251 (Lat: 41.900631,  Lng: -89.053781),  Route carried "on" structure: Other road 5456,  Year Built: 1974,  Status: Open,  Structure Length: 6.92m (22.70ft),  Average Daily Traffic: 1,200 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,400 (year 2020),  Design Load: HS 20,  Features Intersected: I-88 (E-W TOLLWAY),  Facility Carried by Structure: STEWARD RD (FAU545
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.379,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Precast Panels
Find on map >>

Structure Number: 7199162308,  Location: 1.2 MI E OF ILL 251 (Lat: 41.901928,  Lng: -89.044019),  Route carried "on" structure: Interstate 88,  Year Built: 1974,  Status: Open,  Structure Length: 9.45m (31.00ft),  Average Daily Traffic: 7,450 (year 2006),  Truck Traffic: 22%,  Average Future Daily Traffic: 9,500 (year 2020),  Design Load: HS 20,  Features Intersected: FAU5458,CARON&BN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 124.247,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71991723076,  Location: 1.2 MI E OF ILL 251 (Lat: 41.902083,  Lng: -89.044100),  Route carried "on" structure: Interstate 88,  Year Built: 1974,  Status: Open,  Structure Length: 9.45m (31.00ft),  Average Daily Traffic: 7,450 (year 2006),  Truck Traffic: 22%,  Average Future Daily Traffic: 25,600 (year 2024),  Design Load: HS 20,  Features Intersected: FAU5458,CARON&BN RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 124.263,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 71992228526,  Location: .2 MI W OF ILL 251 (Lat: 41.899644,  Lng: -89.073792),  Route carried "on" structure: Interstate 88,  Year Built: 1972,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 13,000 (year 2006),  Truck Traffic: 22%,  Average Future Daily Traffic: 23,200 (year 2025),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 122.043,  Lanes on structure: 4,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 39.6m (129.9ft),  Skew: 10 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.7m (5.6ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 71992328527,  Location: 0.2 MI W OF ILL 251 (Lat: 41.899367,  Lng: -89.073344),  Route carried "on" structure: Ramp Interstate 88,  Year Built: 1972,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 450 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 950 (year 2025),  Design Load: HS 20,  Features Intersected: STREAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 1,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 39.6m (129.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.7m (5.6ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 89.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 71005828626,  Location: 2 MI E OF ROCHELLE (Lat: 41.934511,  Lng: -89.023922),  Route carried "under" structure: Interstate 39,  Year Built: 1980,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 27,800 (year 2007),  Truck Traffic: 36%,  Features Intersected: I-39 & US 51,  Facility Carried by Structure: ILL 38
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 161.045,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.2m (105.6ft)

Find on map >>

Structure Number: 71006210437,  Location: 1 MI N OF LEE CO.LN. (Lat: 41.904939,  Lng: -89.021722),  Route carried "under" structure: Interstate 88,  Year Built: 1981,  Structure Length: 8.48m (27.82ft),  Average Daily Traffic: 14,900 (year 2006),  Truck Traffic: 22%,  Features Intersected: I-88(E-W TOLLWAY),  Facility Carried by Structure: I-39 & US 51 SB
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 126.226,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>

Structure Number: 71006310454,  Location: 1 MI N OF LEE CO.LN. (Lat: 41.904969,  Lng: -89.020822),  Route carried "under" structure: Interstate 88,  Year Built: 1981,  Structure Length: 8.48m (27.82ft),  Average Daily Traffic: 17,100 (year 2006),  Truck Traffic: 20%,  Features Intersected: I-88(E-W TOLLWAY),  Facility Carried by Structure: I-39 & US 51 NB
Minimum Vertical Clearance: 0.50m (1.64ft),  Kilometerpoint: 126.274,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.7m (107.3ft)

Find on map >>

Structure Number: 71006604651,  Location: IN ROCHELLE (Lat: 41.921597,  Lng: -89.068753),  Route carried "under" structure: State highway 38,  Year Built: 1981,  Structure Length: 30.18m (99.02ft),  Average Daily Traffic: 2,400 (year 2007),  Truck Traffic: 10%,  Features Intersected: IL38,CNW&BN RR&1 AVE,  Facility Carried by Structure: ILL 251
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 4.082,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>

Structure Number: 71006604651,  Location: IN ROCHELLE (Lat: 41.921597,  Lng: -89.068753),  Route carried "under" structure: Other road 5447,  Year Built: 1981,  Structure Length: 30.18m (99.02ft),  Average Daily Traffic: 2,550 (year 2007),  Truck Traffic: 10%,  Features Intersected: IL38,CNW&BN RR&1 AVE,  Facility Carried by Structure: ILL 251
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.788,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.1m (65.9ft)

Find on map >>

Structure Number: 71991323083,  Location: .5 MI S ROCHELLE (Lat: 41.900181,  Lng: -89.068203),  Route carried "under" structure: State highway 251,  Year Built: 1974,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 2,300 (year 2007),  Truck Traffic: 15%,  Features Intersected: ILL 251,  Facility Carried by Structure: I-88 EB E-W TOLLW
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 147.175,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>

Structure Number: 71991423082,  Location: .5 MI S ROCHELLE (Lat: 41.900456,  Lng: -89.068200),  Route carried "under" structure: State highway 251,  Year Built: 1974,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 6,000 (year 2007),  Truck Traffic: 22%,  Features Intersected: ILL 251,  Facility Carried by Structure: I-88 WB E-W TOLLWA
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 147.207,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>

Structure Number: 71991523081,  Location: .7 MI E OF ILL 251 (Lat: 41.900631,  Lng: -89.053781),  Route carried "under" structure: Interstate 88,  Year Built: 1974,  Structure Length: 6.92m (22.70ft),  Average Daily Traffic: 14,900 (year 2006),  Truck Traffic: 22%,  Features Intersected: I-88 (E-W TOLLWAY),  Facility Carried by Structure: STEWARD RD (FAU545
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 123.507,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.1m (79.1ft)

Find on map >>

Structure Number: 7199162308,  Location: 1.2 MI E OF ILL 251 (Lat: 41.901928,  Lng: -89.044019),  Route carried "under" structure: Other road 5458,  Year Built: 1974,  Structure Length: 9.45m (31.00ft),  Average Daily Traffic: 700 (year 2007),  Truck Traffic: 13%,  Features Intersected: FAU5458,CARON&BN RR,  Facility Carried by Structure: I-88 EB E-W TOLLWA
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 4.521,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>

Structure Number: 71991723076,  Location: 1.2 MI E OF ILL 251 (Lat: 41.902083,  Lng: -89.044100),  Route carried "under" structure: Other road 5458,  Year Built: 1974,  Structure Length: 9.45m (31.00ft),  Average Daily Traffic: 700 (year 2007),  Truck Traffic: 13%,  Features Intersected: FAU5458,CARON&BN RR,  Facility Carried by Structure: I-88 WB E-W TOLLWA
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 4.505,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Discuss this city on our hugely popular Illinois forum

Back to: Rochelle, IL, Illinois, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.