Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rocky Point, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 13Number of bridges
  • 200ft / 61.3mTotal length
  • 109,490Total average daily traffic
  • 16,907Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rocky Point
  • No street view available for this location

New bridges in Rocky Point, NC - historical statistics
  • New bridges - historical statistics
  • 21950-1959
  • 81980-1989
  • 21990-1999
  • 12000-2009
Average Bridge Daily Traffic in Rocky Point, NC
Average Bridge Truck Traffic in Rocky Point, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 33.3%Satisfactory
  • 16.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.3%Very good
  • 33.3%Good
  • 33.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 33.3%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 50.0%Good
  • 16.7%Satisfactory
  • 33.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Satisfactory
  • 66.7%Fair
Find on map >>   Show street view

Structure Number: 1270159,  Location: 1.19MI. N. OF JCT. NC43 (Lat: 35.981378,  Lng: -77.801394),  Route carried "on" structure: State highway 1541,  Year Built: 1990,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 5,800 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HORNBEAM BRANCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 1270207,  Location: 0.4 MI.E. OF JCT.US301BY (Lat: 35.952394,  Lng: -77.819917),  Route carried "on" structure: Business US 64,  Year Built: 1950,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 6.79m (22.28ft),  Average Daily Traffic: 16,000 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 32,000 (year 2040),  Design Load: H 15,  Features Intersected: TAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 64),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 20.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1410012,  Location: 1.6 MI S. OF JCT NC210 (Lat: 34.416964,  Lng: -77.886261),  Route carried "on" structure: US 117,  Year Built: 1952,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 7,600 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 15,200 (year 2040),  Design Load: HS 15,  Features Intersected: NCDOT/RR(ABANDONED)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1410021,  Location: 2.8 MI. E. OF JCT. US 117 (Lat: 34.443236,  Lng: -77.833711),  Route carried "on" structure: State highway 210,  Year Built: 2009,  Status: Open,  Structure Length: 28.10m (92.19ft),  Average Daily Traffic: 5,700 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 11,400 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: NE CAPE FEAR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: December 2020,  Underwater Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 141009,  Location: 1.2MI.N.JCT.SR1412 (Lat: 34.513425,  Lng: -77.845283),  Route carried "on" structure: State highway 1411,  Year Built: 1990,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 790 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,580 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BRANCH NE.CAPE FEAR RVR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 58.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2020,  Underwater Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 141017,  Location: 0.1 MI W JCT SR1414 (Lat: 34.479892,  Lng: -77.875408),  Route carried "on" structure: State highway 1628,  Year Built: 1984,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 2,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,000 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: PIKE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 141022,  Location: 0.8 MI.E. OF JCT.US117 (Lat: 34.479308,  Lng: -77.878900),  Route carried "on" structure: State highway 1411,  Year Built: 1982,  Status: Open,  Structure Length: 6.82m (22.38ft),  Average Daily Traffic: 2,300 (year 2013),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 77.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1410221,  Location: 0.95 MI. E. OF JCT. US117 (Lat: 34.480131,  Lng: -77.875553),  Route carried "on" structure: State highway 1411,  Year Built: 1982,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 2,800 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: PIKE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 74.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 58.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 1410222,  Location: 0.4 MI.E.JCT.US117 (Lat: 34.441050,  Lng: -77.874422),  Route carried "on" structure: State highway 210,  Year Built: 1982,  Status: Open,  Structure Length: 6.37m (20.90ft),  Average Daily Traffic: 15,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 30,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.0m (101.7ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 75.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 141022,  Location: 0.8 MI.E. OF JCT.US117 (Lat: 34.479308,  Lng: -77.878900),  Route carried "under" structure: Interstate 40,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 23%,  Features Intersected: SR1411
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 141022,  Location: 0.8 MI.E. OF JCT.US117 (Lat: 34.479308,  Lng: -77.878900),  Route carried "under" structure: Interstate 40,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2013),  Truck Traffic: 23%,  Features Intersected: SR1411
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1410222,  Location: 0.4 MI.E.JCT.US117 (Lat: 34.441050,  Lng: -77.874422),  Route carried "under" structure: Interstate 40,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 15,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: NC210
Minimum Vertical Clearance: 5.48m (17.98ft),  Kilometerpoint: 124.359,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Find on map >>   Show street view

Structure Number: 1410222,  Location: 0.4 MI.E.JCT.US117 (Lat: 34.441050,  Lng: -77.874422),  Route carried "under" structure: Interstate 40,  Year Built: 1982,  Structure Length: 0. m,  Average Daily Traffic: 15,750 (year 2019),  Truck Traffic: 23%,  Features Intersected: NC210
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 124.359,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.0m (101.7ft)

Discuss Rocky Point, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.