National Bridge Inventory (NBI) Statistics
Number of bridges: 336
Total length: 30,110 meters (98,786ft)
Total costs: $1,366,700,000
Total average daily traffic: 16,686,094
Total average daily truck traffic: 632,727
National Bridge Inventory (NBI) Registered Bridges for San Francisco

New bridges - Historical Statistics

  • 1900-1909: 4
  • 1910-1919: 2
  • 1920-1929: 2
  • 1930-1939: 42
  • 1940-1949: 2
  • 1950-1959: 83
  • 1960-1969: 159
  • 1970-1979: 24
  • 1980-1989: 0
  • 1990-1999: 1
  • 2000-2010: 17

Reconstructed bridges - Historical Statistics

  • 1930-1939: 1
  • 1940-1949: 0
  • 1950-1959: 4
  • 1960-1969: 12
  • 1970-1979: 3

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 34 0001,  Location: 04-SF-035-2.12-SF (Lat: 37.733611,  Lng: -122.493917),  Route carried "on" structure: State highway 35,  Year Built: 1931,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 29,000 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 39,155 (year 2029),  Design Load: H 20,  Features Intersected: SUNSET BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.120,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 3.6m (11.8ft),  Right: 3.6m (11.8ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 41.9m (137.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0003,  Location: 04-SF-080-6.35-SF (Lat: 37.798194,  Lng: -122.377833),  Route carried "on" structure: Interstate 80,  Year Built: 1936,  Year Reconstructed: 1962,  Status: Open,  Structure Length: 628.13m (2060.79ft),  Average Daily Traffic: 204,900 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 335,134 (year 2029),  Design Load: HS 20,  Features Intersected: SAN FRANCISCO BAY, 3 STS
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 6.350,  Lanes on structure: 5,  Lanes under structure: 24,  Base Highway Network: Yes,  Toll: Toll bridge,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Navigation Control: Yes ( Vertical Clearance: 56.4m (185.0ft), Horizontal Clearance: 673.6m (2,210.0ft)),  Material/Design: Steel,  Design/Construction: Suspension,  Number Of Spans In Main Unit: 6,  Number Of Approach Spans: 3,  Length of Maximum Span: 704.1m (2,310.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 628.13m (2060.79ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 10,  Critical Feature Inspection Date: January 10,  Underwater Inspection Date: May 2008,  Bridge Improvement Cost: $120,612,000,  Roadway Improvement Cost: $24,122,000,  Total Project Cost: $202,628,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>

Structure Number: 34 0007L,  Location: 04-SF-080-8.7-SF (Lat: 37.817694,  Lng: -122.354603),  Route carried "on" structure: Interstate 80,  Year Built: 2008,  Status: Open,  Structure Length: 242.97m (797.15ft),  Average Daily Traffic: 138,850 (year 1997),  Truck Traffic: 10%,  Average Future Daily Traffic: 167,264 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SAN FRANCISCO BAY
Minimum Vertical Clearance: 6.00m (19.69ft),  Kilometerpoint: 8.700,  Lanes on structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Toll: Toll bridge,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Navigation Control: Yes ( Vertical Clearance: 43.0m (141.1ft), Horizontal Clearance: 353.0m (1,158.1ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Segmental Box Girder,  Number Of Spans In Main Unit: 21,  Length of Maximum Span: 160.0m (524.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2008,  Underwater Inspection Date: Febuary 2009,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>

Structure Number: 34 0007R,  Location: 04-SF-080-8.7-SF (Lat: 37.817364,  Lng: -122.354339),  Route carried "on" structure: Interstate 80,  Year Built: 2008,  Status: Open,  Structure Length: 240.90m (790.35ft),  Average Daily Traffic: 138,850 (year 1997),  Truck Traffic: 10%,  Average Future Daily Traffic: 167,264 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SAN FRANCISCO BAY
Minimum Vertical Clearance: 6.00m (19.69ft),  Kilometerpoint: 8.700,  Lanes on structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Toll: Toll bridge,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Navigation Control: Yes ( Vertical Clearance: 43.0m (141.1ft), Horizontal Clearance: 353.0m (1,158.1ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Segmental Box Girder,  Number Of Spans In Main Unit: 21,  Length of Maximum Span: 160.0m (524.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2008,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>

Structure Number: 34 0012,  Location: 04-SF-280-R3.11-SF (Lat: 37.738333,  Lng: -122.418333),  Route carried "on" structure: City street D010,  Year Built: 1963,  Status: Open,  Structure Length: 7.16m (23.49ft),  Average Daily Traffic: 23,600 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 60,564 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ROUTE I 280,  Facility Carried by Structure: MISSION STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 17.8m (58.4ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Serious,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2008,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0012Y,  Location: 04-SF-000-0-SF (Lat: 37.738333,  Lng: -122.418333),  Route carried "on" structure: Business City street ,  Year Built: 1951,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 23,000 (year 1997),  Truck Traffic: 1%,  Average Future Daily Traffic: 59,718 (year 2029),  Features Intersected: ALEMANY BLVD,  Facility Carried by Structure: MISSION STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 12,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.8m (58.4ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 17.8m (58.4ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.64m (18.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2008,  Bridge Improvement Cost: $1,699,000,  Roadway Improvement Cost: $170,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0014,  Location: 04-SF-101-8.33-SF (Lat: 37.805000,  Lng: -122.433333),  Route carried "on" structure: US 101,  Year Built: 1936,  Status: Open,  Structure Length: 139.45m (457.51ft),  Average Daily Traffic: 54,700 (year 1997),  Truck Traffic: 4%,  Average Future Daily Traffic: 72,129 (year 2029),  Design Load: H 20,  Features Intersected: MARSHALL, HALLECK.....
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.330,  Lanes on structure: 6,  Lanes under structure: 12,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 103,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of replacement,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 139.45m (457.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2009,  Bridge Improvement Cost: $57,120,000,  Roadway Improvement Cost: $11,424,000,  Total Project Cost: $95,962,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0015,  Location: 04-SF-001-6.18-SF (Lat: 37.790583,  Lng: -122.470194),  Route carried "on" structure: State highway 1,  Year Built: 1939,  Status: Open,  Structure Length: 4.21m (13.81ft),  Average Daily Traffic: 69,000 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 77,898 (year 2029),  Design Load: H 15,  Features Intersected: WEST PACIFIC AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.180,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 10 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Serious,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 4.21m (13.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $1,504,000,  Roadway Improvement Cost: $300,000,  Total Project Cost: $2,527,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0017,  Location: 04-SF-001-6.67-SF (Lat: 37.797694,  Lng: -122.469500),  Route carried "on" structure: State highway 1,  Year Built: 1939,  Status: Open,  Structure Length: 21.58m (70.80ft),  Average Daily Traffic: 69,000 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 77,898 (year 2029),  Design Load: H 15,  Features Intersected: KOBBE AVE, HITCHCOCK ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.670,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 13.8m (45.3ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Serious,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 21.58m (70.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $3,354,000,  Roadway Improvement Cost: $670,000,  Total Project Cost: $5,634,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0018,  Location: 04-SF-001-6.86-SF (Lat: 37.800694,  Lng: -122.469444),  Route carried "on" structure: State highway 1,  Year Built: 1939,  Status: Open,  Structure Length: 13.56m (44.49ft),  Average Daily Traffic: 69,000 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 77,898 (year 2029),  Design Load: H 15,  Features Intersected: STOREY AVE, SCHOFIELD RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.860,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 12.9m (42.3ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 13.56m (44.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $4,848,000,  Roadway Improvement Cost: $969,000,  Total Project Cost: $8,145,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0019,  Location: 04-SF-101-9.14-SF (Lat: 37.802750,  Lng: -122.467111),  Route carried "on" structure: US 101,  Year Built: 1936,  Year Reconstructed: 1939,  Status: Open,  Structure Length: 46.36m (152.10ft),  Average Daily Traffic: 65,000 (year 1999),  Truck Traffic: 4%,  Average Future Daily Traffic: 72,129 (year 2029),  Design Load: H 20,  Features Intersected: N1-N101, LINCOLN, CRISSY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.140,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Steel,  Design/Construction: Truss - Deck,  Number Of Spans In Main Unit: 8,  Number Of Approach Spans: 10,  Length of Maximum Span: 41.1m (134.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Critical,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 41.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 46.36m (152.10ft),  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2009,  Critical Feature Inspection Date: July 2008,  Bridge Improvement Cost: $19,964,000,  Roadway Improvement Cost: $3,992,000,  Total Project Cost: $33,539,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 002,  Location: 04-SF-101-9.47-SF (Lat: 37.803333,  Lng: -122.468333),  Route carried "on" structure: US 101,  Year Built: 1939,  Year Reconstructed: 1955,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 65,000 (year 1999),  Truck Traffic: 4%,  Average Future Daily Traffic: 72,129 (year 2029),  Design Load: H 15,  Features Intersected: N101-S1 CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.470,  Lanes on structure: 5,  Lanes under structure: 1,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 9 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 31.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 0.94m (3.08ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $219,000,  Roadway Improvement Cost: $43,000,  Total Project Cost: $367,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0021,  Location: 04-SF-001-R.11-SF (Lat: 37.709750,  Lng: -122.471139),  Route carried "on" structure: City street D014,  Year Built: 1950,  Year Reconstructed: 1966,  Status: Open,  Structure Length: 30.14m (98.88ft),  Average Daily Traffic: 12,666 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 18,547 (year 2029),  Design Load: H 15,  Features Intersected: STATE RTE 1 (SPANS 4&5),  Facility Carried by Structure: ALEMANY BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 35.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 30.14m (98.88ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $2,764,000,  Roadway Improvement Cost: $552,000,  Total Project Cost: $4,643,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0022,  Location: 04-SF-001-4.45-SF (Lat: 37.770722,  Lng: -122.479194),  Route carried "on" structure: State highway 1,  Year Built: 1936,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 72,500 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 88,717 (year 2029),  Design Load: H 20,  Features Intersected: JFK DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.450,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 25.2m (82.7ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 3.81m (12.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $2,323,000,  Roadway Improvement Cost: $464,000,  Total Project Cost: $3,902,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0026,  Location: 04-SF-280-R.46-SF (Lat: 37.711667,  Lng: -122.460000),  Route carried "on" structure: Interstate 280,  Year Built: 1966,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 11.31m (37.11ft),  Average Daily Traffic: 128,700 (year 1997),  Truck Traffic: 2%,  Average Future Daily Traffic: 326,212 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ALEMANY BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.460,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 26 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.2m (108.9ft),  Curb-To-Curb Width: 40.2m (131.9ft),  Out-to-Out Width: 41.6m (136.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 11.31m (37.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2008,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 003,  Location: 04-SF-101-.77-SF (Lat: 37.720000,  Lng: -122.385278),  Route carried "on" structure: US 101,  Year Built: 1954,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 199,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 258,116 (year 2029),  Design Load: HS 20,  Features Intersected: 3RD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.770,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.9m (153.9ft),  Skew: 29 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 40.2m (131.9ft),  Curb-To-Curb Width: 41.4m (135.8ft),  Out-to-Out Width: 47.6m (156.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 73.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.23m (27.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $3,141,000,  Roadway Improvement Cost: $314,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0030S,  Location: 04-SF-101-.77-SF (Lat: 37.719722,  Lng: -122.399167),  Route carried "on" structure: Bypass US 101,  Year Built: 1955,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 32,500 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 41,217 (year 2029),  Design Load: HS 20,  Features Intersected: 3RD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.770,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.93m (12.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $453,000,  Roadway Improvement Cost: $90,000,  Total Project Cost: $761,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0032,  Location: 04-SF-101-1.77-SF (Lat: 37.732222,  Lng: -122.404722),  Route carried "on" structure: City street D038,  Year Built: 1954,  Status: Open,  Structure Length: 4.82m (15.81ft),  Average Daily Traffic: 9,281 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 27,821 (year 2029),  Design Load: HS 20,  Features Intersected: ROUTE 101,  Facility Carried by Structure: SILVER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Satisfactory,  Operating Rating: 90.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.82m (15.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $2,362,000,  Roadway Improvement Cost: $472,000,  Total Project Cost: $3,968,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0033,  Location: 04-SF-101-2.03-SF (Lat: 37.736667,  Lng: -122.406667),  Route carried "on" structure: US 101,  Year Built: 1950,  Status: Open,  Structure Length: 23.10m (75.79ft),  Average Daily Traffic: 251,000 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 328,802 (year 2029),  Design Load: HS 20,  Features Intersected: 280/101 IC - ALEMANY CIR
Minimum Vertical Clearance: 6.35m (20.83ft),  Kilometerpoint: 2.030,  Lanes on structure: 6,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 23 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Deck: Imminent failure,  Superstructure: Good,  Substructure: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0034,  Location: 04-SF-101-2.92-SF (Lat: 37.750000,  Lng: -122.401667),  Route carried "on" structure: US 101,  Year Built: 1951,  Year Reconstructed: 1968,  Status: Open,  Structure Length: 19.05m (62.50ft),  Average Daily Traffic: 251,000 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 328,802 (year 2029),  Design Load: HS 20,  Features Intersected: CESAR CHAVEZ BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.920,  Lanes on structure: 8,  Lanes under structure: 10,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 36.0m (118.1ft),  Skew: 29 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 36.0m (118.1ft),  Out-to-Out Width: 36.7m (120.4ft)

Condition: Deck: Critical,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 19.05m (62.50ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Critical Feature Inspection Date: July 2009,  Bridge Improvement Cost: $3,486,000,  Roadway Improvement Cost: $349,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0034S,  Location: 04-SF-101-2.95-SF (Lat: 37.750000,  Lng: -122.401667),  Route carried "on" structure: Bypass US 101,  Year Built: 1974,  Status: Open,  Structure Length: 22.80m (74.80ft),  Average Daily Traffic: 12,600 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 24,730 (year 2029),  Design Load: HS 20,  Features Intersected: CESAR CHAVEZ BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.950,  Lanes on structure: 1,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 42.7m (140.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 64.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 22.80m (74.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $1,807,000,  Roadway Improvement Cost: $361,000,  Total Project Cost: $3,035,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0035,  Location: 04-SF-101-3.37-SF (Lat: 37.755000,  Lng: -122.403611),  Route carried "on" structure: City street D187,  Year Built: 1953,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 4,513 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,439 (year 2029),  Design Load: HS 20,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: 23RD STREET
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.2m (122.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0040G,  Location: 04-SF-001-6.97-SF (Lat: 37.802778,  Lng: -122.468889),  Route carried "on" structure: Ramp State highway 1,  Year Built: 1939,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 8,900 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 24,730 (year 2029),  Design Load: H 15,  Features Intersected: LINCOLN BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.970,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 23.8m (78.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0044,  Location: 04-SF-001-R.31-SF (Lat: 37.712750,  Lng: -122.471250),  Route carried "on" structure: State highway 1,  Year Built: 1952,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 107,000 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 128,182 (year 2029),  Design Load: H 20,  Features Intersected: BROTHERHOOD WAY
Minimum Vertical Clearance: 3.99m (13.09ft),  Kilometerpoint: 0.310,  Lanes on structure: 8,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.5m (54.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 29.3m (96.1ft),  Out-to-Out Width: 38.9m (127.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 3.90m (12.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $1,517,000,  Roadway Improvement Cost: $303,000,  Total Project Cost: $2,548,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0045,  Location: 04-SF-101-2.28-SF (Lat: 37.742500,  Lng: -122.407500),  Route carried "on" structure: US 101,  Year Built: 1950,  Year Reconstructed: 1968,  Status: Open,  Structure Length: 4.04m (13.25ft),  Average Daily Traffic: 251,000 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 328,802 (year 2029),  Design Load: HS 20,  Features Intersected: CORTLAND AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.280,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 36.4m (119.4ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 4.04m (13.25ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $1,503,000,  Roadway Improvement Cost: $300,000,  Total Project Cost: $2,525,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 34 0046,  Location: 04-SF-280-R4.4-SF (Lat: 37.748333,  Lng: -122.391667),  Route carried "on" structure: Interstate 280,  Year Built: 1964,  Status: Open,  Structure Length: 658.00m (2158.79ft),  Average Daily Traffic: 107,000 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 171,459 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: CALTRAIN,UP RR,CITY STS
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 4.400,  Lanes on structure: 6,  Lanes under structure: 40,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 234,  Length of Maximum Span: 40.2m (131.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 32.1m (105.3ft),  Out-to-Out Width: 33.3m (109.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 658.00m (2158.79ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2008,  Bridge Improvement Cost: $219,114,000,  Roadway Improvement Cost: $43,822,000,  Total Project Cost: $368,111,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0047S,  Location: 04-SF-101-2.84-SF (Lat: 37.748333,  Lng: -122.403333),  Route carried "on" structure: Ramp US 101,  Year Built: 1950,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 12,200 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 32,973 (year 2029),  Design Load: HS 20,  Features Intersected: SB101 BAYSHORE OFF-RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.840,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 61.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 4.79m (15.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $442,000,  Roadway Improvement Cost: $88,000,  Total Project Cost: $742,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0056,  Location: 04-SF-101-1.11-SF (Lat: 37.723333,  Lng: -122.400000),  Route carried "on" structure: US 101,  Year Built: 1954,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 222,000 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 374,243 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: PAUL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.110,  Lanes on structure: 10,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 44.5m (146.0ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 43.8m (143.7ft),  Out-to-Out Width: 45.0m (147.6ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.91m (16.11ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Bridge Improvement Cost: $1,772,000,  Roadway Improvement Cost: $177,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0057L,  Location: 04-SF-101-1.41-SF (Lat: 37.727500,  Lng: -122.403611),  Route carried "on" structure: US 101,  Year Built: 1954,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 222,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 271,202 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BACON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.410,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 28.7m (94.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 28.6m (93.8ft),  Out-to-Out Width: 30.4m (99.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0057R,  Location: 04-SF-101-1.41-SF (Lat: 37.728333,  Lng: -122.401667),  Route carried "on" structure: US 101,  Year Built: 1960,  Status: Open,  Structure Length: 1.92m (6.30ft),  Average Daily Traffic: 222,000 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 374,243 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BACON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.410,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 30.7m (100.7ft),  Out-to-Out Width: 31.3m (102.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 34 006,  Location: 04-SF-101-.01-SF (Lat: 37.708333,  Lng: -122.394444),  Route carried "on" structure: US 101,  Year Built: 1954,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 199,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 258,116 (year 2029),  Design Load: HS 20,  Features Intersected: ALANA WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.010,  Lanes on structure: 9,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 59.7m (195.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 59.2m (194.2ft),  Out-to-Out Width: 60.4m (198.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0061,  Location: 04-SF-101-.18-SF (Lat: 37.711667,  Lng: -122.395000),  Route carried "on" structure: US 101,  Year Built: 1954,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 199,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 258,116 (year 2029),  Design Load: HS 20,  Features Intersected: BLANKEN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.180,  Lanes on structure: 8,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 34.0m (111.5ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 34.0m (111.5ft),  Out-to-Out Width: 34.8m (114.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Inventory Rating: 32.4 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0062,  Location: 04-SF-101-9.71-SF (Lat: 37.806261,  Lng: -122.474922),  Route carried "on" structure: US 101,  Year Built: 1938,  Year Reconstructed: 1955,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 115,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 117,710 (year 2031),  Design Load: H 20,  Features Intersected: LINCOLN BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.710,  Lanes on structure: 9,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: Local Toll Authority,  Approaching Roadway Width: 38.1m (125.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.2m (43.3ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 38.1m (125.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.34m (4.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2009,  Bridge Improvement Cost: $614,000,  Roadway Improvement Cost: $61,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 34 0063S,  Location: 04-SF-101-2.2-SF (Lat: 37.738333,  Lng: -122.406667),  Route carried "on" structure: Bypass US 101,  Year Built: 1950,  Status: Open,  Structure Length: 10.09m (33.10ft),  Average Daily Traffic: 6,000 (year 2000),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,892 (year 2029),  Design Load: HS 20,  Features Intersected: ALEMANY CIR UC (NBD O-R)
Minimum Vertical Clearance: 6.91m (22.67ft),  Kilometerpoint: 2.200,  Lanes on structure: 1,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 3.8m (12.5ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0064K,  Location: 04-SF-101-2-SF (Lat: 37.736389,  Lng: -122.407778),  Route carried "on" structure: Bypass US 101,  Year Built: 1954,  Status: Open,  Structure Length: 11.89m (39.01ft),  Average Daily Traffic: 3,200 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,274 (year 2029),  Design Load: HS 20,  Features Intersected: ALEMANY CIR
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 2.000,  Lanes on structure: 1,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0069,  Location: 04-SF-101-9.85-SF (Lat: 37.807064,  Lng: -122.475989),  Route carried "on" structure: US 101,  Year Built: 1936,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 115,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 117,710 (year 2031),  Design Load: H 20,  Features Intersected: TOLL PLAZA UNDERCROSSING
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.850,  Lanes on structure: 13,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 88.7m (291.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.4m (27.6ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 4.0m (13.1ft),  Curb-To-Curb Width: 57.8m (189.6ft),  Out-to-Out Width: 88.7m (291.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 28.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.88m (2.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2009,  Bridge Improvement Cost: $893,000,  Roadway Improvement Cost: $178,000,  Total Project Cost: $1,500,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 007,  Location: 04-SF-101-1.63-SF (Lat: 37.735000,  Lng: -122.406667),  Route carried "on" structure: Ramp US 101,  Year Built: 1960,  Status: Open,  Structure Length: 49.80m (163.39ft),  Average Daily Traffic: 153,800 (year 1997),  Truck Traffic: 2%,  Average Future Daily Traffic: 370,358 (year 2029),  Design Load: HS 20,  Features Intersected: 280/101 INTERCHANGE
Minimum Vertical Clearance: 99.90m (327.76ft),  Kilometerpoint: 1.630,  Lanes on structure: 4,  Lanes under structure: 20,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 18,  Length of Maximum Span: 28.4m (93.2ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 49.80m (163.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2008,  Bridge Improvement Cost: $5,727,000,  Roadway Improvement Cost: $1,145,000,  Total Project Cost: $9,621,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0070E,  Location: 04-SF-280-R4.07-SF (Lat: 37.768333,  Lng: -122.406667),  Route carried "on" structure: Ramp Interstate 280,  Year Built: 1966,  Status: Open,  Structure Length: 35.17m (115.39ft),  Average Daily Traffic: 40,000 (year 1999),  Truck Traffic: 3%,  Average Future Daily Traffic: 104,769 (year 2029),  Design Load: HS 20,  Features Intersected: N101-N280 CONNECTOR RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.070,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 39 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 35.17m (115.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2008,  Bridge Improvement Cost: $3,800,000,  Roadway Improvement Cost: $760,000,  Total Project Cost: $6,384,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0070H,  Location: 04-SF-101-1.48-SF (Lat: 37.768333,  Lng: -122.406667),  Route carried "on" structure: Ramp US 101,  Year Built: 1960,  Status: Open,  Structure Length: 27.49m (90.19ft),  Average Daily Traffic: 80,000 (year 1999),  Truck Traffic: 3%,  Average Future Daily Traffic: 104,769 (year 2029),  Design Load: HS 20,  Features Intersected: 280/101 INTERCHANGE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.480,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 10,  Length of Maximum Span: 29.5m (96.8ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 27.49m (90.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2008,  Bridge Improvement Cost: $3,050,000,  Roadway Improvement Cost: $610,000,  Total Project Cost: $5,124,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0071F,  Location: 04-SF-101-1.94-SF (Lat: 37.732222,  Lng: -122.405000),  Route carried "on" structure: Ramp US 101,  Year Built: 1960,  Status: Open,  Structure Length: 38.28m (125.59ft),  Average Daily Traffic: 56,000 (year 1998),  Truck Traffic: 4%,  Average Future Daily Traffic: 110,253 (year 2029),  Design Load: HS 20,  Features Intersected: 280/101 IC -ALEMANY BLVD
Minimum Vertical Clearance: 99.00m (324.80ft),  Kilometerpoint: 1.940,  Lanes on structure: 2,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 60.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 38.28m (125.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2009,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0073,  Location: 04-SF-280-R3.87-SF (Lat: 37.738333,  Lng: -122.408333),  Route carried "on" structure: City street D014,  Year Built: 1963,  Status: Open,  Structure Length: 11.43m (37.50ft),  Average Daily Traffic: 10,055 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 15,664 (year 2028),  Design Load: HS 20,  Features Intersected: ROUTE 280,  Facility Carried by Structure: ALEMANY BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.7m (127.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Length Of Structure Improvement: 11.43m (37.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2008,  Bridge Improvement Cost: $1,672,000,  Roadway Improvement Cost: $334,000,  Total Project Cost: $2,808,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0074,  Location: 04-SF-280-R3.28-SF (Lat: 37.738333,  Lng: -122.416667),  Route carried "on" structure: City street D014,  Year Built: 1963,  Status: Open,  Structure Length: 8.32m (27.30ft),  Average Daily Traffic: 16,000 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 20,884 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ROUTE I 280,  Facility Carried by Structure: ALEMANY BLVD SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 44.2m (145.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2008,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 34 0075,  Location: 04-SF-280-R3.23-SF (Lat: 37.738333,  Lng: -122.416667),  Route carried "on" structure: City street D084,  Year Built: 1963,  Status: Open,  Structure Length: 5.58m (18.31ft),  Average Daily Traffic: 5,512 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 20,884 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: ROUTE I 280,  Facility Carried by Structure: JUSTIN DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.7m (90.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.58m (18.31ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2008,  Bridge Improvement Cost: $816,000,  Roadway Improvement Cost: $163,000,  Total Project Cost: $1,370,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place

Parts: 1, 2, 3, 4, 5

Jump to a detailed profile or search site with Google Custom Search
Business Search - 14 Million verified businesses
Search for: near: 

Discuss this city on our hugely popular California forum

Back to: San Francisco, CA, California, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.