U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Sandy, Pennsylvania (PA) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Sandy, PA, Pennsylvania, Pennsylvania forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 36
Total length: 178 meters (584ft)
Total costs: $12,328,000
Total average daily traffic: 272,408
Total average daily truck traffic: 66,604
National Bridge Inventory (NBI) Registered Bridges for Sandy

New bridges - Historical Statistics

  • 1910-1919: 2
  • 1920-1929: 1
  • 1930-1939: 3
  • 1940-1949: 0
  • 1950-1959: 1
  • 1960-1969: 25
  • 1970-1979: 2
  • 1980-1989: 1
  • 1990-1999: 0
  • 2000-2009: 1

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 17008009640313,  Location: EXIT 97 DUBOIS INTER (Lat: 41.146861,  Lng: -78.790389),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 10.49m (34.42ft),  Average Daily Traffic: 14,121 (year 2008),  Truck Traffic: 40%,  Average Future Daily Traffic: 13,824 (year 2027),  Design Load: H 15,  Features Intersected: SR 219-US 219
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.389,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 15 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17008009650125,  Location: EXIT 97 DUBOIS INTER (Lat: 41.147472,  Lng: -78.790953),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 11.06m (36.29ft),  Average Daily Traffic: 13,341 (year 2008),  Truck Traffic: 44%,  Average Future Daily Traffic: 18,894 (year 2027),  Design Load: H 15,  Features Intersected: SR 219-US 219
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.388,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 15 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 85.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17008009842208,  Location: 2 MI E EXIT 97 (Lat: 41.141889,  Lng: -78.746819),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 3.87m (12.70ft),  Average Daily Traffic: 14,121 (year 2008),  Truck Traffic: 40%,  Average Future Daily Traffic: 21,190 (year 2027),  Design Load: H 15,  Features Intersected: T-399
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.590,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.87m (12.70ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Bridge Improvement Cost: $90,000,  Roadway Improvement Cost: $266,000,  Total Project Cost: $1,220,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17008009852321,  Location: 2 MI E EXIT 97 (Lat: 41.142333,  Lng: -78.746567),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 14,030 (year 2008),  Truck Traffic: 41%,  Average Future Daily Traffic: 21,769 (year 2027),  Design Load: H 15,  Features Intersected: TOWNSHIP ROAD 399
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.581,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.51m (14.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Bridge Improvement Cost: $105,000,  Roadway Improvement Cost: $310,000,  Total Project Cost: $1,422,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Preformed Fabric
Find on map >>

Structure Number: 17008010100307,  Location: EXIT 101 PENFIELD INTER (Lat: 41.129528,  Lng: -78.708992),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 13,912 (year 2008),  Truck Traffic: 40%,  Average Future Daily Traffic: 17,912 (year 2027),  Design Load: H 15,  Features Intersected: SR 255/BUFFALO & PITT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.630,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.32m (24.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Bridge Improvement Cost: $120,000,  Roadway Improvement Cost: $352,000,  Total Project Cost: $1,615,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 1700801010188,  Location: ONE-HALF MI E EXIT 101 (Lat: 41.128000,  Lng: -78.703661),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 13,912 (year 2008),  Truck Traffic: 40%,  Average Future Daily Traffic: 19,912 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CR/BUFF& PITT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.630,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: May 2005,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17008010110414,  Location: EXIT 101 PENFIELD INTER (Lat: 41.129861,  Lng: -78.708456),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 13,767 (year 2008),  Truck Traffic: 41%,  Average Future Daily Traffic: 26,814 (year 2027),  Design Load: H 15,  Features Intersected: SR 255/BUFFALO & PITT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.651,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.32m (24.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Bridge Improvement Cost: $151,000,  Roadway Improvement Cost: $444,000,  Total Project Cost: $2,036,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17008010112001,  Location: ONE-HALF MI E EXIT 101 (Lat: 41.128306,  Lng: -78.703058),  Route carried "on" structure: Interstate 80,  Year Built: 1967,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 13,767 (year 2008),  Truck Traffic: 41%,  Average Future Daily Traffic: 26,814 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CR/BUFF& PITT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.651,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.1m (36.4ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.02m (26.31ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: May 2005,  Bridge Improvement Cost: $76,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $1,023,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 170219083,  Location: 1 MI S DUBOIS (Lat: 41.092500,  Lng: -78.771422),  Route carried "on" structure: US 219,  Year Built: 1957,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 3,465 (year 2008),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,398 (year 2027),  Design Load: H 15,  Features Intersected: PENTZ RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 63.304,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Inventory Rating: 69.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2007,  Underwater Inspection Date: August 2003
Find on map >>

Structure Number: 17021908500325,  Location: DUBOIS (Lat: 41.108583,  Lng: -78.771283),  Route carried "on" structure: US 219,  Year Built: 2002,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 11,311 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 12,457 (year 2027),  Design Load: H 15,  Features Intersected: PENTZ RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 65.027,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 10.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 61.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.40m (4.59ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2007,  Underwater Inspection Date: September 2003
Find on map >>

Structure Number: 17021909200709,  Location: FALLS CREEK (Lat: 41.141056,  Lng: -78.784047),  Route carried "on" structure: US 219,  Year Built: 1969,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 7,974 (year 2008),  Truck Traffic: 9%,  Average Future Daily Traffic: 9,982 (year 2027),  Design Load: H 15,  Features Intersected: SLAB RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 70.480,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 61.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: September 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 17021909210697,  Location: FALLS CREEK (Lat: 41.140917,  Lng: -78.784233),  Route carried "on" structure: US 219,  Year Built: 1969,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 7,945 (year 2008),  Truck Traffic: 9%,  Average Future Daily Traffic: 9,982 (year 2027),  Design Load: H 15,  Features Intersected: SLAB RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 70.476,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 11 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 18.7m (61.4ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: September 2003,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 17021909500486,  Location: 3 MI N FALLS CREEK (Lat: 41.180056,  Lng: -78.778108),  Route carried "on" structure: US 219,  Year Built: 1962,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 8,923 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 15,235 (year 2027),  Design Load: H 15,  Features Intersected: TRIB OF WOLF RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.144,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 49.0 metric tons,  Inventory Rating: 32.7 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: September 2003,  Bridge Improvement Cost: $26,000,  Roadway Improvement Cost: $237,000,  Total Project Cost: $346,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 170255008,  Location: 2 MI SW SABULA (Lat: 41.136583,  Lng: -78.696597),  Route carried "on" structure: State highway 255,  Year Built: 1939,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 6,070 (year 2008),  Truck Traffic: 15%,  Average Future Daily Traffic: 10,464 (year 2027),  Design Load: H 15,  Features Intersected: NARROWS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.478,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 88.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: September 2003,  Bridge Improvement Cost: $39,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $531,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 170255014,  Location: SABULA (Lat: 41.166778,  Lng: -78.662619),  Route carried "on" structure: State highway 255,  Year Built: 1929,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 5,952 (year 2008),  Truck Traffic: 11%,  Average Future Daily Traffic: 5,814 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.189,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Satisfactory,  Inventory Rating: 57.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.82m (2.69ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: July 2003,  Bridge Improvement Cost: $39,000,  Roadway Improvement Cost: $237,000,  Total Project Cost: $529,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17083000200628,  Location: FALLS CREEK (Lat: 41.142333,  Lng: -78.793800),  Route carried "on" structure: State highway 830,  Year Built: 1969,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 8,478 (year 2008),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,945 (year 2027),  Design Load: H 15,  Features Intersected: WOLF RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.220,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.50m (8.20ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: June 2005,  Bridge Improvement Cost: $40,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $541,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17083000203224,  Location: FALLS CREEK (Lat: 41.140361,  Lng: -78.785053),  Route carried "on" structure: State highway 830,  Year Built: 1969,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 8,478 (year 2008),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,945 (year 2027),  Design Load: H 15,  Features Intersected: SLAB RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.220,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 0.91m (2.99ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: September 2003,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $447,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 174015003,  Location: 1 MI E EXIT 101 (Lat: 41.123583,  Lng: -78.689119),  Route carried "on" structure: State highway ,  Year Built: 1969,  Status: Open,  Structure Length: 10.39m (34.09ft),  Average Daily Traffic: 370 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 503 (year 2027),  Design Load: H 15,  Features Intersected: SR 80-I 80,  Facility Carried by Structure: SR 4015
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.791,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Serious,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2007,  Bridge Improvement Cost: $46,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $622,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 17401500601483,  Location: 1 MI W SABULA (Lat: 41.140611,  Lng: -78.683333),  Route carried "on" structure: State highway ,  Year Built: 1985,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 370 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 800 (year 2027),  Design Load: H 15,  Features Intersected: SANDY CREEK,  Facility Carried by Structure: SR 4015
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.650,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 92.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: June 2007,  Underwater Inspection Date: October 2004
Find on map >>

Structure Number: 17401600100228,  Location: OKLAHOMA (Lat: 41.105194,  Lng: -78.714267),  Route carried "on" structure: State highway ,  Year Built: 1938,  Status: Posted for load,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 1,321 (year 2008),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,408 (year 2028),  Design Load: H 15,  Features Intersected: LABORDE BR SANDY CREEK,  Facility Carried by Structure: SR 4016
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.1m (49.5ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Poor,  Channel: Fair,  Operating Rating: 23.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.55m (5.09ft),  Designated Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Underwater Inspection Date: March 2007,  Other Special Inspection Date: March 2008,  Bridge Improvement Cost: $51,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $690,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17401700200519,  Location: OKLAHOMA (Lat: 41.118194,  Lng: -78.731583),  Route carried "on" structure: State highway ,  Year Built: 1967,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 12,682 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 15,933 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CREEK,  Facility Carried by Structure: SR 4017
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.364,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.07m (6.79ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: May 2007,  Underwater Inspection Date: May 2005,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $250,000,  Total Project Cost: $444,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17722803500005,  Location: 1900 FT SE OF PA 830 (Lat: 41.137417,  Lng: -78.790444),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 675 (year 1985),  Average Future Daily Traffic: 945 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CREEK,  Facility Carried by Structure: T-350
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: August 2007,  Underwater Inspection Date: August 2007,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17722803720005,  Location: 190FT SE OF SR 255 INTER (Lat: 41.123389,  Lng: -78.718972),  Route carried "on" structure: City street ,  Year Built: 1930,  Status: Posted for load,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 190 (year 1985),  Average Future Daily Traffic: 238 (year 2027),  Design Load: H 15,  Features Intersected: SANDY LICK CREEK,  Facility Carried by Structure: T-372
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Superstructure: Critical,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 5.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 4.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.95m (6.40ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: July 2005,  Underwater Inspection Date: July 2005,  Bridge Improvement Cost: $-1,000,  Roadway Improvement Cost: $-1,000,  Total Project Cost: $-1,000
Find on map >>

Structure Number: 17722803990005,  Location: .25 MI NE OF END SR 4019 (Lat: 41.133333,  Lng: -78.758333),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,000 (year 1985),  Average Future Daily Traffic: 1,470 (year 2027),  Design Load: HS 20,  Features Intersected: CLEAR RUN,  Facility Carried by Structure: T-399
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Inventory Rating: 32.7 metric tons,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: August 2007,  Underwater Inspection Date: August 2007
Find on map >>

Structure Number: 17722808540005,  Location: 1.0 MI SW OF SR 255 INTER (Lat: 41.138333,  Lng: -78.720000),  Route carried "on" structure: City street ,  Year Built: 1915,  Status: Closed,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1 (year 2000),  Average Future Daily Traffic: 44 (year 2024),  Features Intersected: NARROWS CREEK,  Facility Carried by Structure: T-854
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Poor,  Superstructure: Failed,  Substructure: Failed,  Channel: Fair,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: August 2007,  Underwater Inspection Date: August 2007,  Bridge Improvement Cost: $18,000,  Roadway Improvement Cost: $72,000,  Total Project Cost: $243,000,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17722809150005,  Location: 400 FT EAST OF SR 4014 (Lat: 41.093667,  Lng: -78.707278),  Route carried "on" structure: City street ,  Year Built: 1915,  Status: Posted for load,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 60 (year 1985),  Average Future Daily Traffic: 75 (year 2027),  Design Load: H 15,  Features Intersected: LUTHERSBURGBRSANDYLICKCR,  Facility Carried by Structure: T-915
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.3m (14.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 5.3m (17.4ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 17.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 10.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.10m (3.61ft),  Designated Inspection Frequency: Every 12 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2007,  Other Special Inspection Date: May 2007,  Bridge Improvement Cost: $46,000,  Roadway Improvement Cost: $264,000,  Total Project Cost: $619,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 17008009640313,  Location: EXIT 97 DUBOIS INTER (Lat: 41.146861,  Lng: -78.790389),  Route carried "under" structure: US 219,  Year Built: 1967,  Structure Length: 10.49m (34.42ft),  Average Daily Traffic: 4,462 (year 2007),  Truck Traffic: 8%,  Features Intersected: SR 219-US 219,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 71.164,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>

Structure Number: 17008009640313,  Location: EXIT 97 DUBOIS INTER (Lat: 41.146861,  Lng: -78.790389),  Route carried "under" structure: US 219,  Year Built: 1967,  Structure Length: 10.49m (34.42ft),  Average Daily Traffic: 4,462 (year 2007),  Truck Traffic: 8%,  Features Intersected: SR 219-US 219,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 7.123,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>

Structure Number: 17008009650125,  Location: EXIT 97 DUBOIS INTER (Lat: 41.147472,  Lng: -78.790953),  Route carried "under" structure: US 219,  Year Built: 1967,  Structure Length: 11.06m (36.29ft),  Average Daily Traffic: 4,462 (year 2007),  Truck Traffic: 8%,  Features Intersected: SR 219-US 219,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 4.73m (15.52ft),  Kilometerpoint: 71.164,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>

Structure Number: 17008009650125,  Location: EXIT 97 DUBOIS INTER (Lat: 41.147472,  Lng: -78.790953),  Route carried "under" structure: US 219,  Year Built: 1967,  Structure Length: 11.06m (36.29ft),  Average Daily Traffic: 4,462 (year 2007),  Truck Traffic: 8%,  Features Intersected: SR 219-US 219,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 4.73m (15.52ft),  Kilometerpoint: 7.123,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>

Structure Number: 17008009842208,  Location: 2 MI E EXIT 97 (Lat: 41.141889,  Lng: -78.746819),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 3.87m (12.70ft),  Average Daily Traffic: 3,850 (year 1984),  Truck Traffic: 10%,  Features Intersected: T-399,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 6.37m (20.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>

Structure Number: 17008009852321,  Location: 2 MI E EXIT 97 (Lat: 41.142333,  Lng: -78.746567),  Route carried "under" structure: City street ,  Year Built: 1967,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 3,850 (year 1992),  Truck Traffic: 1%,  Features Intersected: TOWNSHIP ROAD 399,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 8.28m (27.17ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>

Structure Number: 17008010100307,  Location: EXIT 101 PENFIELD INTER (Lat: 41.129528,  Lng: -78.708992),  Route carried "under" structure: State highway 255,  Year Built: 1967,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 16,875 (year 2008),  Truck Traffic: 5%,  Features Intersected: SR 255/BUFFALO & PITT,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 7.49m (24.57ft),  Kilometerpoint: 3.933,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>

Structure Number: 17008010110414,  Location: EXIT 101 PENFIELD INTER (Lat: 41.129861,  Lng: -78.708456),  Route carried "under" structure: State highway 255,  Year Built: 1967,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 6,070 (year 2008),  Truck Traffic: 15%,  Features Intersected: SR 255/BUFFALO & PITT,  Facility Carried by Structure: SR 80-I 80
Minimum Vertical Clearance: 7.59m (24.90ft),  Kilometerpoint: 3.933,  Lanes on structure: 3,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>

Structure Number: 174015003,  Location: 1 MI E EXIT 101 (Lat: 41.123583,  Lng: -78.689119),  Route carried "under" structure: Interstate 80,  Year Built: 1969,  Structure Length: 10.39m (34.09ft),  Average Daily Traffic: 13,912 (year 2008),  Truck Traffic: 40%,  Features Intersected: SR 80-I 80,  Facility Carried by Structure: SR 4015
Minimum Vertical Clearance: 5.07m (16.63ft),  Kilometerpoint: 9.241,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>

Structure Number: 174015003,  Location: 1 MI E EXIT 101 (Lat: 41.123583,  Lng: -78.689119),  Route carried "under" structure: Interstate 80,  Year Built: 1969,  Structure Length: 10.39m (34.09ft),  Average Daily Traffic: 13,767 (year 2008),  Truck Traffic: 41%,  Features Intersected: SR 80-I 80,  Facility Carried by Structure: SR 4015
Minimum Vertical Clearance: 5.07m (16.63ft),  Kilometerpoint: 9.255,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Discuss this city on our hugely popular Pennsylvania forum

Back to: Sandy, PA, Pennsylvania, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.