U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Santa Clarita, California (CA) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Santa Clarita, CA, California, California forum, All US cities.





Parts: 1, 2


National Bridge Inventory (NBI) Statistics
Number of bridges: 94
Total length: 549 meters (1,801ft)
Total costs: $58,538,000
Total average daily traffic: 3,522,100
Total average daily truck traffic: 282,857
National Bridge Inventory (NBI) Registered Bridges for Santa Clarita
No street view available for this location

New bridges - Historical Statistics

  • 1930-1939: 2
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 19
  • 1970-1979: 28
  • 1980-1989: 18
  • 1990-1999: 11
  • 2000-2009: 16

Reconstructed bridges - Historical Statistics

  • 1980-1989: 2
  • 1990-1999: 10
  • 2000-2009: 1

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>   Show street view

Structure Number: 53 0014,  Location: 07-LA-126-9.93-SCTA (Lat: 34.391667,  Lng: -118.536667),  Route carried "on" structure: State highway 126,  Year Built: 1993,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 23,800 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,500 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: PLACERITA CREEK,  Facility Carried by Structure: RAILROAD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.930,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 24.1m (79.1ft),  Skew: 12 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 26.5m (86.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 0015,  Location: 07-LA-126-8.2-SCTA (Lat: 34.414319,  Lng: -118.543944),  Route carried "on" structure: State highway 126,  Year Built: 1995,  Status: Open,  Structure Length: 13.96m (45.80ft),  Average Daily Traffic: 23,800 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 32,500 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SOUTH FK SANTA CLARA RIV,  Facility Carried by Structure: MAGIC MOUNTAIN PKW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.200,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 54.9m (180.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 29.2m (95.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 0688,  Location: 07-LA-005-R53.94-SCTA (Lat: 34.428486,  Lng: -118.586078),  Route carried "on" structure: Interstate 5,  Year Built: 1964,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 129,000 (year 2009),  Truck Traffic: 16%,  Average Future Daily Traffic: 195,644 (year 2030),  Design Load: HS 20,  Features Intersected: ABANDONED RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.940,  Lanes on structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.2m (151.6ft),  Skew: 32 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 45.7m (149.9ft),  Out-to-Out Width: 47.1m (154.5ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1621,  Location: 07-LA-014-32.53-SCTA (Lat: 34.418831,  Lng: -118.437039),  Route carried "on" structure: State highway 14,  Year Built: 1963,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 113,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 199,229 (year 2030),  Design Load: HS 20,  Features Intersected: LOST CANYON ROAD UC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.530,  Lanes on structure: 8,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 42.0m (137.8ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 41.6m (136.5ft),  Out-to-Out Width: 43.1m (141.4ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.83m (9.28ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Bridge Improvement Cost: $1,220,000,  Roadway Improvement Cost: $244,000,  Total Project Cost: $2,049,000 ( Estimate for 2010),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1688,  Location: 07-LA-005-R54.17-SCTA (Lat: 34.431128,  Lng: -118.588136),  Route carried "on" structure: Interstate 5,  Year Built: 1964,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 129,000 (year 2009),  Truck Traffic: 16%,  Average Future Daily Traffic: 195,644 (year 2030),  Design Load: HS 20,  Features Intersected: RYE CANYON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.170,  Lanes on structure: 8,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.3m (151.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 46.3m (151.9ft),  Out-to-Out Width: 47.1m (154.5ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1792L,  Location: 07-LA-005-R49.03-SCTA (Lat: 34.362214,  Lng: -118.555306),  Route carried "on" structure: Interstate 5,  Year Built: 1967,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 193,000 (year 2009),  Truck Traffic: 13%,  Average Future Daily Traffic: 195,551 (year 2029),  Design Load: HS 20,  Features Intersected: CALGROVE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.030,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 1792R,  Location: 07-LA-005-R49.03-SCTA (Lat: 34.362453,  Lng: -118.555044),  Route carried "on" structure: Interstate 5,  Year Built: 1967,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 193,000 (year 2009),  Truck Traffic: 20%,  Average Future Daily Traffic: 195,551 (year 2029),  Design Load: HS 20,  Features Intersected: CALGROVE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.030,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2029,  Location: 07-LA-014-R31.62-SCTA (Lat: 34.410061,  Lng: -118.446061),  Route carried "on" structure: State highway 14,  Year Built: 1972,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 113,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 199,229 (year 2030),  Design Load: HS 20,  Features Intersected: METROLINK & UP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.620,  Lanes on structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.6m (175.9ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 52.8m (173.2ft),  Out-to-Out Width: 54.2m (177.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2096,  Location: 07-LA-014-R25.97-SCTA (Lat: 34.350375,  Lng: -118.504236),  Route carried "on" structure: State highway 14,  Year Built: 1971,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 4.21m (13.81ft),  Average Daily Traffic: 159,000 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 234,016 (year 2030),  Design Load: HS 20,  Features Intersected: LOS PINETOS ROAD
Minimum Vertical Clearance: 99.90m (327.76ft),  Kilometerpoint: 25.970,  Lanes on structure: 11,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.7m (176.2ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 10,  Length of Maximum Span: 41.5m (136.2ft),  Curb-To-Curb Width: 53.7m (176.2ft),  Out-to-Out Width: 54.3m (178.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2146,  Location: 07-LA-014-R27.55-SCTA (Lat: 34.371764,  Lng: -118.499764),  Route carried "on" structure: State highway 14,  Year Built: 1972,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 10.94m (35.89ft),  Average Daily Traffic: 148,000 (year 2009),  Truck Traffic: 4%,  Average Future Daily Traffic: 227,839 (year 2030),  Design Load: HS 20,  Features Intersected: LA AQUEDUCT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 27.550,  Lanes on structure: 8,  Lanes under structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.3m (151.9ft),  Skew: 39 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 45.5m (149.3ft),  Out-to-Out Width: 46.9m (153.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 58.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2167,  Location: 07-LA-014-R31.4-SCTA (Lat: 34.406869,  Lng: -118.447661),  Route carried "on" structure: State highway 14,  Year Built: 1972,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 113,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 199,229 (year 2030),  Design Load: HS 20,  Features Intersected: CANYON PARK BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.400,  Lanes on structure: 9,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 51.9m (170.3ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.9m (144.0ft),  Curb-To-Curb Width: 51.9m (170.3ft),  Out-to-Out Width: 52.5m (172.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2361,  Location: 07-LA-126-T12.51-SCTA (Lat: 34.365694,  Lng: -118.505861),  Route carried "on" structure: State highway 126,  Year Built: 1969,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 23,800 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 32,500 (year 2029),  Design Load: HS 20,  Features Intersected: ELSMERE CREEK,  Facility Carried by Structure: NEWHALL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.510,  Lanes on structure: 7,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 31.1m (102.0ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 11
Find on map >>   Show street view

Structure Number: 53 2788,  Location: 07-LA-126-10.57-SCTA (Lat: 34.383694,  Lng: -118.530528),  Route carried "on" structure: State highway 126,  Year Built: 1996,  Status: Open,  Structure Length: 3.73m (12.24ft),  Average Daily Traffic: 23,800 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 32,500 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: NEWHALL CREEK,  Facility Carried by Structure: RAILROAD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.570,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 23.7m (77.8ft),  Skew: 13 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.3m (122.4ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 23.7m (77.8ft),  Out-to-Out Width: 26.7m (87.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2816,  Location: 07-LA-014-33.42-SCTA (Lat: 34.425186,  Lng: -118.423653),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 6.70m (21.98ft),  Average Daily Traffic: 5,000 (year 1997),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,873 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 14,  Facility Carried by Structure: SAND CANYON ROAD
Minimum Vertical Clearance: 99.90m (327.76ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 12 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.7m (123.7ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 25.6m (84.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 289,  Location: 07-LA-126-9.75-SCTA (Lat: 34.395000,  Lng: -118.539764),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 25.60m (83.99ft),  Average Daily Traffic: 5,000 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,500 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: RAILROAD AV, SANTA CLARA,  Facility Carried by Structure: VIA PRINCESSA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Maintenance Responsibility: Local Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 19 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 45.1m (148.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 23.1m (75.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2925,  Location: 07-LA-005-R53.7-SCTA (Lat: 34.425467,  Lng: -118.584311),  Route carried "on" structure: Interstate 5,  Year Built: 2005,  Status: Open,  Structure Length: 22.90m (75.13ft),  Average Daily Traffic: 129,000 (year 2009),  Truck Traffic: 16%,  Average Future Daily Traffic: 195,644 (year 2030),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.700,  Lanes on structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 57.0m (187.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 51.0m (167.3ft),  Curb-To-Curb Width: 57.0m (187.0ft),  Out-to-Out Width: 58.0m (190.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2927,  Location: 07-LA-005-R52.47-SCTA (Lat: 34.408264,  Lng: -118.576281),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 10.40m (34.12ft),  Average Daily Traffic: 21,000 (year 1991),  Truck Traffic: 2%,  Average Future Daily Traffic: 31,431 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 5,  Facility Carried by Structure: VALENCIA BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 52.470,  Lanes on structure: 7,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 30.6m (100.4ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 56.0m (183.7ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 30.6m (100.4ft),  Out-to-Out Width: 35.8m (117.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2928,  Location: 07-LA-005-R53.33-SCTA (Lat: 34.423281,  Lng: -118.583333),  Route carried "on" structure: Interstate 5,  Year Built: 2005,  Status: Open,  Structure Length: 9.40m (30.84ft),  Average Daily Traffic: 144,000 (year 2009),  Truck Traffic: 12%,  Average Future Daily Traffic: 185,965 (year 2029),  Design Load: HS 20,  Features Intersected: MAGIC MOUNTAIN PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.330,  Lanes on structure: 8,  Lanes under structure: 7,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.3m (151.9ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 45.7m (149.9ft),  Out-to-Out Width: 47.2m (154.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53 2944,  Location: 07-LA-126-R5.84-SCTA (Lat: 34.443222,  Lng: -118.605500),  Route carried "on" structure: State highway 126,  Year Built: 2005,  Status: Open,  Structure Length: 10.18m (33.40ft),  Average Daily Traffic: 23,800 (year 2006),  Truck Traffic: 16%,  Average Future Daily Traffic: 32,500 (year 2029),  Design Load: HS 20,  Features Intersected: INTERSTATE 5
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.840,  Lanes on structure: 8,  Lanes under structure: 10,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 46.8m (153.5ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 56.8m (186.4ft),  Curb-To-Curb Width: 42.8m (140.4ft),  Out-to-Out Width: 43.8m (143.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 11,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0296,  Location: 1.3 MI N SOLDAD CYN RD (Lat: 34.430550,  Lng: -118.443197),  Route carried "on" structure: City street L369,  Year Built: 1986,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 14,700 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 18,135 (year 2032),  Design Load: HS 20,  Features Intersected: MINT CANYON WASH,  Facility Carried by Structure: SIERRA HIGHWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 29.5m (96.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0378,  Location: 0.1 MI N SOLDAD CYN RD (Lat: 34.424231,  Lng: -118.539606),  Route carried "on" structure: City street Q064,  Year Built: 1972,  Status: Open,  Structure Length: 15.88m (52.10ft),  Average Daily Traffic: 43,100 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 53,806 (year 2032),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER,  Facility Carried by Structure: BOUQUET CYN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 3.8m (12.5ft),  Curb-To-Curb Width: 36.5m (119.8ft),  Out-to-Out Width: 41.7m (136.8ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0379,  Location: 0.8 MI N SOLEDAD CYN RD (Lat: 34.430756,  Lng: -118.534211),  Route carried "on" structure: City street Q064,  Year Built: 1972,  Status: Open,  Structure Length: 4.19m (13.75ft),  Average Daily Traffic: 36,000 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 45,260 (year 2034),  Design Load: HS 20,  Features Intersected: BOUQUET CANYON CREEK,  Facility Carried by Structure: BOUQUET CYN RD SX
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 27.6m (90.6ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.8m (61.7ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 32.6m (107.0ft)

Condition: Deck: Serious,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.15m (16.90ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 12,  Bridge Improvement Cost: $2,821,000,  Roadway Improvement Cost: $282,000,  Total Project Cost: $4,231,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C038,  Location: 4MI N OF SOLEDAD CYN RD (Lat: 34.459489,  Lng: -118.494072),  Route carried "on" structure: City street Q064,  Year Built: 1969,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 49,900 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 62,340 (year 2032),  Design Load: HS 20,  Features Intersected: BOUQUET CANYON CREEK,  Facility Carried by Structure: BOUQUET CYN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 52.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.26m (7.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Bridge Improvement Cost: $712,000,  Roadway Improvement Cost: $71,000,  Total Project Cost: $1,069,000 ( Estimate for 2012),  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0469,  Location: 4 MI E BOUQUET CYN RD (Lat: 34.415708,  Lng: -118.477281),  Route carried "on" structure: City street Q065,  Year Built: 1973,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 17.68m (58.01ft),  Average Daily Traffic: 48,100 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 60,051 (year 2032),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER,  Facility Carried by Structure: SOLEDAD CANYON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 29 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 18.38m (60.30ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $5,787,000,  Roadway Improvement Cost: $578,000,  Total Project Cost: $8,681,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0478,  Location: 1.4 MI N SOLEDAD CYN RD (Lat: 34.434611,  Lng: -118.523811),  Route carried "on" structure: City street Q064,  Year Built: 1976,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 48,800 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 60,987 (year 2032),  Design Load: HS 20,  Features Intersected: BOUQUET CANYON CREEK,  Facility Carried by Structure: BOUQUET CYN RD NX
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.4m (73.5ft),  Skew: 25 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 22.4m (73.5ft),  Out-to-Out Width: 32.9m (107.9ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.58m (21.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Bridge Improvement Cost: $3,571,000,  Roadway Improvement Cost: $357,000,  Total Project Cost: $5,357,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0479,  Location: 3 MI N SOLEDAD CYN RD (Lat: 34.449386,  Lng: -118.498664),  Route carried "on" structure: City street Q064,  Year Built: 1967,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 19,100 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 23,833 (year 2032),  Design Load: HS 20,  Features Intersected: PLUM CANYON CHANNEL,  Facility Carried by Structure: BOUQUET CYN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 33.7m (110.6ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10
Find on map >>   Show street view

Structure Number: 53C0554,  Location: 0.1 MI E SIERRA HWY (Lat: 34.416486,  Lng: -118.454075),  Route carried "on" structure: City street Q065,  Year Built: 1982,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 46,000 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 57,449 (year 2032),  Design Load: HS 20,  Features Intersected: MINT CANYON WASH,  Facility Carried by Structure: SOLEDAD CANYON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 23 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 25.7m (84.3ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0805,  Location: 3/4MI E OF GLDN ST FWY (Lat: 34.378956,  Lng: -118.552508),  Route carried "on" structure: City street Q055,  Year Built: 1966,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 32,800 (year 2000),  Truck Traffic: 4%,  Average Future Daily Traffic: 41,142 (year 2033),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIV (SO FK),  Facility Carried by Structure: LYONS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 24.3m (79.7ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 36.7m (120.4ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.04m (6.69ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11,  Bridge Improvement Cost: $643,000,  Roadway Improvement Cost: $64,000,  Total Project Cost: $965,000 ( Estimate for 2012)
Find on map >>   Show street view

Structure Number: 53C0826,  Location: 1MI N OF LYONS AVE (Lat: 34.389000,  Lng: -118.548078),  Route carried "on" structure: City street Q056,  Year Built: 1971,  Status: Open,  Structure Length: 2.65m (8.69ft),  Average Daily Traffic: 24,000 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 29,874 (year 2031),  Design Load: HS 20,  Features Intersected: PICO CANYON CHANNEL,  Facility Carried by Structure: WILEY CYN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 31.2m (102.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2009,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C084,  Location: 1.0 MI N/O LYONS AVE (Lat: 34.388222,  Lng: -118.546042),  Route carried "on" structure: City street Q057,  Year Built: 1970,  Status: Open,  Structure Length: 9.08m (29.79ft),  Average Daily Traffic: 23,200 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 29,126 (year 2034),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIV (SO FK),  Facility Carried by Structure: ORCHARD VILLAGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 16.5m (54.1ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 12,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0855,  Location: 0.5 MI S/O LYONS AVE (Lat: 34.370489,  Lng: -118.557475),  Route carried "on" structure: City street Q056,  Year Built: 1971,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 12,100 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 15,141 (year 2033),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIV (SO FK),  Facility Carried by Structure: WILEY CYN RD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft)

Condition: Channel: Excellent,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11
Find on map >>   Show street view

Structure Number: 53C0988,  Location: 0.1 MI E SIERRA HWY (Lat: 34.424836,  Lng: -118.448094),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 14,700 (year 2003),  Truck Traffic: 1%,  Average Future Daily Traffic: 18,135 (year 2032),  Design Load: HS 20,  Features Intersected: MINT CANYON WASH,  Facility Carried by Structure: ADON AVE
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 52.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $577,000,  Roadway Improvement Cost: $57,000,  Total Project Cost: $866,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C0992,  Location: 0.2 MI S SOLEDAD CYN RD (Lat: 34.421628,  Lng: -118.423228),  Route carried "on" structure: City street L578,  Year Built: 1986,  Status: Open,  Structure Length: 15.39m (50.49ft),  Average Daily Traffic: 13,500 (year 2000),  Truck Traffic: 2%,  Average Future Daily Traffic: 16,860 (year 2032),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER,  Facility Carried by Structure: SAND CYN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 25.6m (84.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Poor,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 77.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C1024,  Location: 0.4 MI S SOLEDAD CYN RD (Lat: 34.419839,  Lng: -118.424392),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 6,800 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,534 (year 2032),  Design Load: HS 20,  Features Intersected: SAND CANYON WASH,  Facility Carried by Structure: LOST CANYON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.20m (7.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Bridge Improvement Cost: $692,000,  Roadway Improvement Cost: $69,000,  Total Project Cost: $1,039,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C1028,  Location: 2.5 MI S SOLEDAD CYN RD (Lat: 34.393917,  Lng: -118.414908),  Route carried "on" structure: City street L578,  Year Built: 1970,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 3,200 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 4,163 (year 2032),  Design Load: HS 20,  Features Intersected: IRON CANYON CREEK,  Facility Carried by Structure: SAND CANYON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 10,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C1488L,  Location: .25MI N/O MGC MNT PRKWY (Lat: 34.418708,  Lng: -118.548736),  Route carried "on" structure: City street Q065,  Year Built: 1967,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 58,500 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 72,334 (year 2032),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER SO FK,  Facility Carried by Structure: VALENCIA BLD SOUTH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 0.0m,  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.80m (22.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Bridge Improvement Cost: $2,140,000,  Roadway Improvement Cost: $214,000,  Total Project Cost: $3,211,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C1488R,  Location: .25MI N/O MGC MNT PRKWY (Lat: 34.418661,  Lng: -118.548586),  Route carried "on" structure: City street Q065,  Year Built: 1967,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 58,500 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 72,334 (year 2032),  Design Load: HS 20,  Features Intersected: SANTA CLARA RIVER SO FK,  Facility Carried by Structure: VALENCIA BLD NORTH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 58.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.80m (22.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Bridge Improvement Cost: $1,777,000,  Roadway Improvement Cost: $177,000,  Total Project Cost: $2,666,000 ( Estimate for 2012),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C149,  Location: .25MI N/O BOUQUET CYN RD (Lat: 34.448597,  Lng: -118.506717),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 2.96m (9.71ft),  Average Daily Traffic: 4,800 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 6,244 (year 2032),  Design Load: HS 20,  Features Intersected: BOUQUET CYN CHANNEL,  Facility Carried by Structure: URBANDALE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C1492,  Location: 0.5 MI E SAND CANYON RD (Lat: 34.407867,  Lng: -118.412522),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 1,000 (year 2008),  Average Future Daily Traffic: 1,200 (year 2028),  Design Load: HS 20,  Features Intersected: UNNAMED WASH,  Facility Carried by Structure: CLEARLAKE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 10
Find on map >>   Show street view

Structure Number: 53C1521,  Location: 0.1 MI W AVENIDA ROTELLA (Lat: 34.381544,  Lng: -118.546717),  Route carried "on" structure: City street QQ09,  Year Built: 1967,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 500 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 627 (year 2033),  Design Load: HS 20,  Features Intersected: PUC,  Facility Carried by Structure: AVENIDA RONDEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 4.8m (15.7ft),  Right: 4.9m (16.1ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 22.8m (74.8ft)

Condition: Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11
Find on map >>   Show street view

Structure Number: 53C1522,  Location: 0.1 MI N LYONS AVE (Lat: 34.380344,  Lng: -118.546125),  Route carried "on" structure: City street 7QQ1,  Year Built: 1967,  Status: Open,  Structure Length: 2.63m (8.63ft),  Average Daily Traffic: 500 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 627 (year 2033),  Design Load: HS 20,  Features Intersected: PUC,  Facility Carried by Structure: AVENIDA ROTELLA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 4.2m (13.8ft),  Right: 4.3m (14.1ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 11
Find on map >>   Show street view

Structure Number: 53C1528,  Location: 0.3 MI W SECO CANYON RD (Lat: 34.436778,  Lng: -118.534961),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 1.35m (4.43ft),  Average Daily Traffic: 700 (year 2008),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,020 (year 2034),  Design Load: HS 20,  Features Intersected: DRY CANYON CHANNEL,  Facility Carried by Structure: GARZOTA DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 50.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 12,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete

Parts: 1, 2

Jump to a detailed profile or search site with Google Custom Search
Business Search - 14 Million verified businesses
Search for: near: 

Discuss this city on our hugely popular California forum

Back to: Santa Clarita, CA, California, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2013 Advameg, Inc.