National Bridge Inventory (NBI) Statistics
Number of bridges: 15
Total length: 651 meters (2,136ft)
Total average daily traffic: 88,262
Total average daily truck traffic: 6,889
National Bridge Inventory (NBI) Registered Bridges for Sault Ste. Marie

New bridges - Historical Statistics

  • 1930-1939: 2
  • 1940-1949: 0
  • 1950-1959: 0
  • 1960-1969: 6
  • 1970-1979: 4
  • 1980-1989: 1
  • 1990-1999: 1
  • 2000-2009: 1

Reconstructed bridges - Historical Statistics

  • 1980-1989: 2
  • 1990-1999: 1

Average Daily Traffic

Average Truck Traffic (%)

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 17117032000B02,  Location: IN SAULT STE MARIE (Lat: 46.495439,  Lng: -84.349300),  Route carried "on" structure: Business Interstate 75,  Year Built: 1934,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.83m (25.69ft),  Average Daily Traffic: 12,797 (year 2003),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,788 (year 2018),  Design Load: H 20,  Features Intersected: POWER CANAL
Minimum Vertical Clearance: 5.66m (18.57ft),  Kilometerpoint: 27.771,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 317,  Subroute: 36),  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 78.3m (256.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 82.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 45.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 15 months,  Inspection Date: May 2006,  Critical Feature Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 17117032000B03,  Location: SAULT STE MARIE (Lat: 46.498489,  Lng: -84.363944),  Route carried "on" structure: Business Interstate 75,  Year Built: 1970,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 8.07m (26.48ft),  Average Daily Traffic: 4,500 (year 1995),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,880 (year 2013),  Design Load: HS 20,  Features Intersected: POWER CANAL
Minimum Vertical Clearance: 5.26m (17.26ft),  Kilometerpoint: 0.354,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 147,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 80.7m (264.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 73.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 15 months,  Inspection Date: May 2006,  Critical Feature Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 17117034000B01,  Location: SAULT STE MARIE (Lat: 46.508422,  Lng: -84.360650),  Route carried "on" structure: Interstate 75,  Year Built: 1963,  Status: Open,  Structure Length: 282.86m (928.02ft),  Average Daily Traffic: 5,090 (year 2003),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,701 (year 2018),  Design Load: HS 20,  Features Intersected: ST MARY RIV/PORTAGE AV W
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 43.169,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 146,  Subroute: 10),  Toll: Toll bridge,  Owner: State Toll Authority,  Approaching Roadway Width: 25.6m (84.0ft),  Navigation Control: Yes ( Vertical Clearance: 37.8m (124.0ft), Horizontal Clearance: 10.5m (34.4ft)),  Material/Design: Steel continuous,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 8,  Number Of Approach Spans: 55,  Length of Maximum Span: 131.1m (430.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 5 months,  Inspection Date: September 2007,  Underwater Inspection Date: August 1999,  Bridge Improvement Cost: $3,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>

Structure Number: 17117034000S03,  Location: S LTS OF SAULT STE MARIE (Lat: 46.462883,  Lng: -84.383131),  Route carried "on" structure: Business Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 4,900 (year 1995),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,000 ,  Design Load: H 15,  Features Intersected: I-75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.145,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 146,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.1m (75.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 71.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 17117034000S04,  Location: IN SAULT STE MARIE (Lat: 46.491706,  Lng: -84.370833),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 7,230 (year ),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,230 ,  Design Load: HS 20+Mod,  Features Intersected: I-75,  Facility Carried by Structure: EASTERDAY AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.173,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 174602800001B01,  Location: IN SAULT STE MARIE (Lat: 46.497028,  Lng: -84.358092),  Route carried "on" structure: City street ,  Year Built: 2004,  Status: Open,  Structure Length: 7.29m (23.92ft),  Average Daily Traffic: 4,250 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,700 (year 2024),  Design Load: HS 20,  Features Intersected: POWER CANAL,  Facility Carried by Structure: FORT STREET
Minimum Vertical Clearance: 7.62m (25.00ft),  Kilometerpoint: 0.266,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 71.3m (233.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 174602800007B04,  Location: SAULT STE MARIE (Lat: 46.491681,  Lng: -84.373672),  Route carried "on" structure: City street ,  Year Built: 1994,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 8,347 (year 1997),  Average Future Daily Traffic: 11,690 (year 2017),  Design Load: HS 20,  Features Intersected: ASHMUN CREEK,  Facility Carried by Structure: EASTERDAY AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.956,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.7m (64.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 174602800017B03,  Location: IN SAULT STE MARIE (Lat: 46.493939,  Lng: -84.336347),  Route carried "on" structure: City street 2019,  Year Built: 1983,  Status: Open,  Structure Length: 8.68m (28.48ft),  Average Daily Traffic: 3,300 (year 1980),  Average Future Daily Traffic: 6,160 (year 2017),  Design Load: HS 20,  Features Intersected: POWER CANAL,  Facility Carried by Structure: SPRUCE ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.184,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 84.7m (277.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Inventory Rating: 69.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 174602800025B01,  Location: SAULT STE MARIE (Lat: 46.477814,  Lng: -84.304089),  Route carried "on" structure: City street 234,  Year Built: 1935,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 3,160 (year 1997),  Truck Traffic: 45%,  Average Future Daily Traffic: 4,800 (year 2019),  Design Load: H 15,  Features Intersected: MISSION CREEK,  Facility Carried by Structure: RIVERSIDE DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 29.829,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Poor,  Channel: Very good,  Operating Rating: 55.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 174602800042B06,  Location: IN SAULT STE MARIE (Lat: 46.494572,  Lng: -84.347131),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 6.82m (22.38ft),  Average Daily Traffic: 6,966 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,090 (year 2019),  Design Load: HS 20,  Features Intersected: POWER CANAL,  Facility Carried by Structure: BINGHAM AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.378,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 67.0m (219.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 55.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 25.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 174602800048B02,  Location: IN SAULT STE MARIE (Lat: 46.493328,  Lng: -84.340911),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 8.65m (28.38ft),  Average Daily Traffic: 3,720 (year 1997),  Truck Traffic: 53%,  Average Future Daily Traffic: 5,210 (year 2019),  Design Load: HS 20,  Features Intersected: POWER CANAL,  Facility Carried by Structure: JOHNSTONE ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.715,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 84.4m (276.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Inventory Rating: 21.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 174602800065B01,  Location: SAULT STE MARIE (Lat: 46.496083,  Lng: -84.333231),  Route carried "on" structure: City street 2019,  Year Built: 1970,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 8.07m (26.48ft),  Average Daily Traffic: 10,866 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 10,866 (year 2018),  Design Load: HS 20,  Features Intersected: POWER CANAL,  Facility Carried by Structure: WEST PORTAGE AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.644,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 190,  Subroute: 4),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 80.7m (264.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Very good,  Superstructure: Serious,  Substructure: Very good,  Channel: Good,  Operating Rating: 74.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Critical Feature Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 17117034000B01,  Location: SAULT STE MARIE (Lat: 46.508422,  Lng: -84.360650),  Route carried "under" structure: City street ,  Year Built: 1963,  Structure Length: 282.86m (928.02ft),  Average Daily Traffic: 1,500 (year 1999),  Features Intersected: ST MARY RIV/PORTAGE AV W,  Facility Carried by Structure: I-75, INT'L BRIDGE
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.241,  Lanes on structure: 2,  Lanes under structure: 5,  Toll: Toll bridge,  Material/Design: Steel continuous,  Design/Construction: Truss - Thru,  Length of Maximum Span: 131.1m (430.1ft)

Find on map >>

Structure Number: 17117034000S03,  Location: S LTS OF SAULT STE MARIE (Lat: 46.462883,  Lng: -84.383131),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 6,546 (year 2003),  Truck Traffic: 10%,  Features Intersected: I-75
Minimum Vertical Clearance: 5.12m (16.80ft),  Kilometerpoint: 38.449,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>

Structure Number: 17117034000S04,  Location: IN SAULT STE MARIE (Lat: 46.491706,  Lng: -84.370833),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 5,090 (year 2003),  Truck Traffic: 9%,  Features Intersected: I-75,  Facility Carried by Structure: EASTERDAY AVE
Minimum Vertical Clearance: 5.64m (18.50ft),  Kilometerpoint: 41.935,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)