Bridge Statistics for Sheffield, Ohio (OH) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Sheffield, OH, Ohio, Ohio forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 12 Total length: 119 meters (390ft) Total average daily traffic: 294,642 Total average daily truck traffic: 33,060 National Bridge Inventory (NBI) Registered Bridges for Sheffield
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 4704835, Location: .53 MILES EAST OF SR 301 (Lat: 41.450000, Lng: -82.070000), Route carried "on" structure: City street 22, Year Built: 1970, Status: Open, Structure Length: 9.63m (31.59ft), Average Daily Traffic: 8,100 (year 1973), Truck Traffic: 10%, Average Future Daily Traffic: 70,052 (year 2027), Design Load: H 15, Features Intersected: OVER LOR-090 -1753, Facility Carried by Structure: IR 90 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.620, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 3 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 28.7m (94.2ft), Curb-To-Curb Width: 9.1m (29.9ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 4704894, Location: .85 MILES EAST OF SR 301 (Lat: 41.453333, Lng: -82.068333), Route carried "on" structure: Interstate 90, Year Built: 1970, Status: Open, Structure Length: 4.69m (15.39ft), Average Daily Traffic: 26,670 (year 2005), Truck Traffic: 14%, Average Future Daily Traffic: 35,026 (year 2027), Design Load: HS 20, Features Intersected: OVER CSXT RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 28.730, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 15.2m (49.9ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 17.7m (58.1ft), Curb or Sidewalk Widths: Left: 0.3m (1.0ft), Right: 0.3m (1.0ft), Curb-To-Curb Width: 11.7m (38.4ft), Out-to-Out Width: 12.8m (42.0ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Fair, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 31.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 4704924, Location: .85 MILES EAST OF SR 301 (Lat: 41.453333, Lng: -82.068333), Route carried "on" structure: Interstate 90, Year Built: 1970, Status: Open, Structure Length: 4.97m (16.31ft), Average Daily Traffic: 26,670 (year 2005), Truck Traffic: 14%, Average Future Daily Traffic: 35,026 (year 2027), Design Load: HS 20, Features Intersected: OVER CSXT RR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 28.730, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 15.2m (49.9ft), Skew: 3 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 18.3m (60.0ft), Curb-To-Curb Width: 11.6m (38.1ft), Out-to-Out Width: 12.8m (42.0ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Fair, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 470625, Location: 0.9 MI. E. OF JCT SR 57 (Lat: 41.420833, Lng: -82.101111), Route carried "on" structure: State highway 254, Year Built: 2001, Status: Open, Structure Length: 43.31m (142.09ft), Average Daily Traffic: 13,900 (year 2005), Truck Traffic: 2%, Average Future Daily Traffic: 17,086 (year 2025), Design Load: HS 20+Mod, Features Intersected: BLACK RIVER AND METROPRK, Facility Carried by Structure: NORTH RIDGE ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.450, Lanes on structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 16.8m (55.1ft), Skew: 9 degrees, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 12, Length of Maximum Span: 36.3m (119.1ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 15.6m (51.2ft), Out-to-Out Width: 19.2m (63.0ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Very good, Channel: Very good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4706277, Location: 1.91 MILES EAST OF SR 57 (Lat: 41.428333, Lng: -82.083333), Route carried "on" structure: State highway 254, Year Built: 1970, Year Reconstructed: 2003, Status: Open, Structure Length: 9.27m (30.41ft), Average Daily Traffic: 24,212 (year 2005), Truck Traffic: 3%, Average Future Daily Traffic: 33,606 (year 2028), Design Load: HS 20+Mod, Features Intersected: OVER LOR-090-1565 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.080, Lanes on structure: 5, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 26.8m (87.9ft), Skew: 2 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 26.8m (87.9ft), Curb-To-Curb Width: 26.8m (87.9ft), Out-to-Out Width: 27.7m (90.9ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Meets minimum limits, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: September 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4706722, Location: 1.14 MILES N OF SR 254 (Lat: 41.443333, Lng: -82.075000), Route carried "on" structure: State highway 301, Year Built: 1970, Status: Open, Structure Length: 9.11m (29.89ft), Average Daily Traffic: 8,820 (year 2005), Truck Traffic: 5%, Average Future Daily Traffic: 14,199 (year 2027), Design Load: H 20, Features Intersected: OVER LOR-090-1700 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 37.820, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 1 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 26.5m (86.9ft), Curb-To-Curb Width: 9.3m (30.5ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 33.3 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 24.3 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: High priority of corrective action, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 4706811, Location: 1.50 MILES NORTH OF IR 90 (Lat: 41.465000, Lng: -82.076667), Route carried "on" structure: State highway 301, Year Built: 1947, Status: Open, Structure Length: 2.07m (6.79ft), Average Daily Traffic: 8,820 (year 2005), Truck Traffic: 5%, Average Future Daily Traffic: 14,199 (year 2027), Design Load: H 15, Features Intersected: FRENCH CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 40.230, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 20.1m (65.9ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 7.9m (25.9ft) Condition: Deck: Poor, Superstructure: Fair, Substructure: Satisfactory, Channel: Satisfactory, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: High priority of replacement, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Latex Concrete Find on map >>
Structure Number: 4706838, Location: .88 MILES NORTH OF SR 611 (Lat: 41.470556, Lng: -82.113611), Route carried "on" structure: State highway 301, Year Built: 1995, Status: Open, Structure Length: 7.25m (23.79ft), Average Daily Traffic: 12,430 (year 2005), Truck Traffic: 4%, Average Future Daily Traffic: 17,253 (year 2029), Design Load: HS 20+Mod, Features Intersected: OVER N&W RR AND ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 41.840, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 20.7m (67.9ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 30.2m (99.1ft), Curb-To-Curb Width: 20.7m (67.9ft), Out-to-Out Width: 21.6m (70.9ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 40.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 4739833, Location: .33MI.WEST OF ABBE (Lat: 41.450000, Lng: -82.081667), Route carried "on" structure: City street M0022, Year Built: 1929, Year Reconstructed: 1988, Status: Open, Structure Length: 0.73m (2.40ft), Average Daily Traffic: 5,000 (year 1996), Average Future Daily Traffic: 6,940 (year 2026), Design Load: HS 20+Mod, Features Intersected: JUNGBLUTH DT FRENCH, Facility Carried by Structure: FRENCH CREEK RD. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: County Highway Agency, Approaching Roadway Width: 9.1m (29.9ft), Skew: 4 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 1, Length of Maximum Span: 6.4m (21.0ft), Curb-To-Curb Width: 9.6m (31.5ft), Out-to-Out Width: 9.8m (32.2ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Channel: Good, Operating Rating: 40.5 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 12 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 4704835, Location: .53 MILES EAST OF SR 301 (Lat: 41.450000, Lng: -82.070000), Route carried "under" structure: Interstate 90, Year Built: 1970, Structure Length: 9.63m (31.59ft), Average Daily Traffic: 53,340 (year 2005), Truck Traffic: 14%, Features Intersected: UNDER FRENCH CREEK TH-22 Minimum Vertical Clearance: 4.72m (15.49ft), Kilometerpoint: 2.822, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 28.7m (94.2ft) Find on map >>
Structure Number: 4706277, Location: 1.91 MILES EAST OF SR 57 (Lat: 41.428333, Lng: -82.083333), Route carried "under" structure: Interstate 90, Year Built: 1970, Structure Length: 9.27m (30.41ft), Average Daily Traffic: 53,340 (year 2005), Truck Traffic: 14%, Features Intersected: UNDER LOR 254-0191, Facility Carried by Structure: SR 254 Minimum Vertical Clearance: 4.65m (15.26ft), Kilometerpoint: 0.252, Lanes on structure: 5, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 26.8m (87.9ft) Find on map >>
Structure Number: 4706722, Location: 1.14 MILES N OF SR 254 (Lat: 41.443333, Lng: -82.075000), Route carried "under" structure: Interstate 90, Year Built: 1970, Structure Length: 9.11m (29.89ft), Average Daily Traffic: 53,340 (year 2005), Truck Traffic: 14%, Features Intersected: UNDER LOR-301-23.49, Facility Carried by Structure: SR 301 Minimum Vertical Clearance: 4.67m (15.32ft), Kilometerpoint: 2.737, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 26.5m (86.9ft) Discuss this city on our hugely popular Ohio forum Back to: Sheffield, OH, Ohio, All US cities.
|
![]() |