Bridge Statistics for Sidney, Nebraska (NE) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Sidney, NE, Nebraska, Nebraska forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 16 Total length: 72 meters (236ft) Total average daily traffic: 52,461 Total average daily truck traffic: 10,235 National Bridge Inventory (NBI) Registered Bridges for Sidney
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: S080 05864L, Location: 1.3W E. SIDNEY INTERCHNG (Lat: 41.106667, Lng: -102.968333), Route carried "on" structure: Interstate 80, Year Built: 1974, Year Reconstructed: 2000, Status: Open, Structure Length: 6.22m (20.41ft), Average Daily Traffic: 3,963 (year 2007), Truck Traffic: 62%, Average Future Daily Traffic: 7,133 (year 2027), Design Load: HS 20, Features Intersected: FAU 6350 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 94.352, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.3m (37.1ft), Skew: 3 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 31.4m (103.0ft), Curb-To-Curb Width: 12.0m (39.4ft), Out-to-Out Width: 12.9m (42.3ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Satisfactory, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete Find on map >>
Structure Number: S080 05864R, Location: 1.3W E SIDNEY INTERCHNG (Lat: 41.106667, Lng: -102.968333), Route carried "on" structure: Interstate 80, Year Built: 1974, Year Reconstructed: 2000, Status: Open, Structure Length: 6.22m (20.41ft), Average Daily Traffic: 3,963 (year 2007), Truck Traffic: 62%, Average Future Daily Traffic: 7,133 (year 2027), Design Load: HS 20, Features Intersected: FAS 1122 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 94.352, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.3m (37.1ft), Skew: 3 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 31.4m (103.0ft), Curb-To-Curb Width: 12.0m (39.4ft), Out-to-Out Width: 12.9m (42.3ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Satisfactory, Operating Rating: 54.9 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 34.2 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete Find on map >>
Structure Number: S080 05992L, Location: EAST SIDNEY INTRCHG (Lat: 41.106667, Lng: -102.940000), Route carried "on" structure: Interstate 80, Year Built: 1974, Year Reconstructed: 2000, Status: Open, Structure Length: 5.61m (18.41ft), Average Daily Traffic: 3,975 (year 2007), Truck Traffic: 62%, Average Future Daily Traffic: 7,155 (year 2027), Design Load: HS 20, Features Intersected: L17J EAST SIDNEY CNLK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 96.411, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.3m (37.1ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 27.7m (90.9ft), Curb-To-Curb Width: 12.0m (39.4ft), Out-to-Out Width: 12.9m (42.3ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Good, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete Find on map >>
Structure Number: S080 05992R, Location: EAST SIDNEY INTRCHG (Lat: 41.106667, Lng: -102.940000), Route carried "on" structure: Interstate 80, Year Built: 1974, Year Reconstructed: 2000, Status: Open, Structure Length: 5.61m (18.41ft), Average Daily Traffic: 3,975 (year 2007), Truck Traffic: 62%, Average Future Daily Traffic: 7,155 (year 2027), Design Load: HS 20, Features Intersected: L17J EAST SIDNEY CNLK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 96.411, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.3m (37.1ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 27.7m (90.9ft), Curb-To-Curb Width: 12.0m (39.4ft), Out-to-Out Width: 12.9m (42.3ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Good, Operating Rating: 32.4 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete Find on map >>
Structure Number: U223004103P, Location: SIDNEY 11TH/LODGEPOLE CR (Lat: 41.125000, Lng: -102.971667), Route carried "on" structure: City street 6363, Year Built: 1996, Status: Open, Structure Length: 3.51m (11.52ft), Average Daily Traffic: 5,500 (year 2006), Average Future Daily Traffic: 5,500 (year 2026), Design Load: HS 20, Features Intersected: LODGEPOLE CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 162.943, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 14.3m (46.9ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 13.4m (44.0ft), Curb or Sidewalk Widths: Left: 1.2m (3.9ft), Right: 1.2m (3.9ft), Curb-To-Curb Width: 13.9m (45.6ft), Out-to-Out Width: 17.1m (56.1ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Very good, Operating Rating: 85.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 51.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: U22301431, Location: FORT SIDNEY Rd @TOLEDO (Lat: 41.133333, Lng: -102.958333), Route carried "on" structure: City street 19, Year Built: 1936, Status: Open, Structure Length: 2.99m (9.81ft), Average Daily Traffic: 300 (year 2003), Truck Traffic: 10%, Average Future Daily Traffic: 390 (year 2027), Design Load: H 15, Features Intersected: LODGEPOLE CREEK, Facility Carried by Structure: FORT SIDNEY RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 2, Length of Maximum Span: 12.5m (41.0ft), Curb or Sidewalk Widths: Left: 0.3m (1.0ft), Right: 0.3m (1.0ft), Curb-To-Curb Width: 7.3m (24.0ft), Out-to-Out Width: 8.8m (28.9ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Channel: Very good, Operating Rating: 44.1 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 27.0 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: U22301441, Location: SIDNEY DRAW RD AND 19TH (Lat: 41.133333, Lng: -102.985000), Route carried "on" structure: City street 6354, Year Built: 1996, Status: Open, Structure Length: 3.63m (11.91ft), Average Daily Traffic: 635 (year 2006), Average Future Daily Traffic: 635 (year 2026), Design Load: HS 20, Features Intersected: LODGEPOLE CREEK, Facility Carried by Structure: SIDNEY DRAW RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 161.302, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 7.3m (24.0ft), Skew: 1 degrees, Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 13.7m (44.9ft), Curb-To-Curb Width: 9.9m (32.5ft), Out-to-Out Width: 10.4m (34.1ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Very good, Operating Rating: 82.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 49.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: U223024505, Location: Greenwood/Lodgepole Creek (Lat: 41.135000, Lng: -102.951667), Route carried "on" structure: City street 245, Year Built: 1935, Status: Posted for load, Structure Length: 1.01m (3.31ft), Average Daily Traffic: 50 (year 2003), Truck Traffic: 1%, Average Future Daily Traffic: 65 (year 2027), Features Intersected: LODGEPOLE CREEK, Facility Carried by Structure: GREENWOOD ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 1, Length of Maximum Span: 9.8m (32.2ft), Curb-To-Curb Width: 7.5m (24.6ft), Out-to-Out Width: 7.8m (25.6ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Fair, Operating Rating: 36.0 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 25.2 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Meets minimum limits, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Wood or Timber, Wearing Surface/Protective System: Wearing Surface: Wood or Timber Find on map >>
Structure Number: U2230K4105, Location: SIDNEY 13TH/LODGEPOLE CR (Lat: 41.125000, Lng: -102.973333), Route carried "on" structure: City street 6361, Year Built: 1996, Status: Open, Structure Length: 3.47m (11.38ft), Average Daily Traffic: 2,300 (year 2006), Average Future Daily Traffic: 2,300 (year 2026), Design Load: HS 20, Features Intersected: LODGEPOLE CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 161.399, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 14.3m (46.9ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 13.1m (43.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m, Curb-To-Curb Width: 9.8m (32.2ft), Out-to-Out Width: 12.3m (40.4ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Channel: Very good, Operating Rating: 81.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 48.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Superior to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: S030 05983, Location: IN SIDNEY (Lat: 41.140000, Lng: -102.956667), Route carried "under" structure: US 30, Year Built: 1987, Structure Length: 6.46m (21.19ft), Average Daily Traffic: 6,050 (year 2006), Truck Traffic: 6%, Features Intersected: BNSF RR 089-035-A, Facility Carried by Structure: BNSF RR Minimum Vertical Clearance: 5.63m (18.47ft), Kilometerpoint: 96.266, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.0m (105.0ft) Find on map >>
Structure Number: S080 05864L, Location: 1.3W E. SIDNEY INTERCHNG (Lat: 41.106667, Lng: -102.968333), Route carried "under" structure: City street 6350, Year Built: 1974, Structure Length: 6.22m (20.41ft), Average Daily Traffic: 5,835 (year 2007), Features Intersected: WB-I80, Facility Carried by Structure: I80 Minimum Vertical Clearance: 5.53m (18.14ft), Kilometerpoint: 160.932, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 31.4m (103.0ft) Find on map >>
Structure Number: S080 05864R, Location: 1.3W E SIDNEY INTERCHNG (Lat: 41.106667, Lng: -102.968333), Route carried "under" structure: County highway 1122, Year Built: 1974, Structure Length: 6.22m (20.41ft), Average Daily Traffic: 1,320 (year 2007), Features Intersected: EB-I80, Facility Carried by Structure: I80 Minimum Vertical Clearance: 4.97m (16.31ft), Kilometerpoint: 5.422, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 31.4m (103.0ft) Find on map >>
Structure Number: S080 05992L, Location: EAST SIDNEY INTRCHG (Lat: 41.106667, Lng: -102.940000), Route carried "under" structure: Spur State highway L17J, Year Built: 1974, Structure Length: 5.61m (18.41ft), Average Daily Traffic: 5,315 (year 2007), Features Intersected: WB-I80, Facility Carried by Structure: I80 Minimum Vertical Clearance: 5.53m (18.14ft), Kilometerpoint: 0.037, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.7m (90.9ft) Find on map >>
Structure Number: S080 05992R, Location: EAST SIDNEY INTRCHG (Lat: 41.106667, Lng: -102.940000), Route carried "under" structure: Spur State highway L17J, Year Built: 1974, Structure Length: 5.61m (18.41ft), Average Daily Traffic: 5,315 (year 2007), Features Intersected: EB-I80, Facility Carried by Structure: I80 Minimum Vertical Clearance: 0.52m (1.71ft), Kilometerpoint: 0.338, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 27.7m (90.9ft) Find on map >>
Structure Number: U22302421, Location: East Elm St. @ BNRR (Lat: 41.150000, Lng: -102.955000), Route carried "under" structure: City street 242, Year Built: 1921, Structure Length: 1.95m (6.40ft), Average Daily Traffic: 90 (year 2003), Features Intersected: BNSF RR 089-037-N, Facility Carried by Structure: BNSF RR Minimum Vertical Clearance: 4.87m (15.98ft), Kilometerpoint: 0.000, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 7.3m (24.0ft) Find on map >>
Structure Number: U2230K411, Location: SIDNEY 13TH @ HICKORY (Lat: 41.140000, Lng: -102.973333), Route carried "under" structure: City street 6361, Year Built: 1956, Structure Length: 2.10m (6.89ft), Average Daily Traffic: 3,875 (year 2006), Features Intersected: UPRR 817-833-J, Facility Carried by Structure: UPRR Minimum Vertical Clearance: 4.49m (14.73ft), Kilometerpoint: 163.024, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 20.7m (67.9ft) Discuss this city on our hugely popular Nebraska forum Back to: Sidney, NE, Nebraska, All US cities.
|
![]() |