Bridge Statistics for Smyrna, Delaware (DE) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Smyrna, DE, Delaware, Delaware forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 16 Total length: 102 meters (335ft) Total costs: $1,000,000 Total average daily traffic: 271,073 Total average daily truck traffic: 28,923 National Bridge Inventory (NBI) Registered Bridges for Smyrna
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Bridge Condition - Culverts Find on map >>
Structure Number: 1464 03, Location: NORTH OF SMYRNA (Lat: 39.322208, Lng: -75.609653), Route carried "on" structure: County highway 30, Year Built: 1990, Status: Open, Structure Length: 6.51m (21.36ft), Average Daily Traffic: 2,987 (year 2005), Truck Traffic: 7%, Average Future Daily Traffic: 2,139 (year 2016), Design Load: HS 25, Features Intersected: SR 1, Facility Carried by Structure: PADDOCK RD. Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.820, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 6.9m (22.6ft), Skew: 1 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 32.0m (105.0ft), Curb-To-Curb Width: 13.4m (44.0ft), Out-to-Out Width: 14.2m (46.6ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 82.2 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 51.5 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 1914N08, Location: NORTH OF SMYRNA (Lat: 39.330178, Lng: -75.624603), Route carried "on" structure: State highway 1, Year Built: 1993, Status: Open, Structure Length: 10.52m (34.51ft), Average Daily Traffic: 20,545 (year 2005), Truck Traffic: 14%, Average Future Daily Traffic: 7,550 (year 2014), Design Load: HS 25, Features Intersected: US 13 (DUPONT BLVD), Facility Carried by Structure: KOREAN VET MEM HWY Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 3.364, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Toll: On toll road, Owner: State Highway Agency, Approaching Roadway Width: 12.3m (40.4ft), Skew: 6 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 50.3m (165.0ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 15.4m (50.5ft) Condition: Deck: Very good, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 97.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 57.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 1914S08, Location: NORTH OF SMYRNA (Lat: 39.330247, Lng: -75.625297), Route carried "on" structure: State highway 1, Year Built: 1993, Status: Open, Structure Length: 10.52m (34.51ft), Average Daily Traffic: 20,545 (year 2005), Truck Traffic: 14%, Average Future Daily Traffic: 7,550 (year 2014), Design Load: HS 25, Features Intersected: US 13 (DUPONT BLVD), Facility Carried by Structure: KOREAN VET MEM HWY Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 29.869, Lanes on structure: 2, Lanes under structure: 4, Base Highway Network: Yes, Toll: On toll road, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 6 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 50.3m (165.0ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 15.4m (50.5ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 97.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 57.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: May 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 2001A001, Location: SMYRNA (Lat: 39.296944, Lng: -75.600000), Route carried "on" structure: US 13, Year Built: 1940, Status: Open, Structure Length: 1.42m (4.66ft), Average Daily Traffic: 22,365 (year 2005), Truck Traffic: 9%, Average Future Daily Traffic: 24,712 (year 2016), Design Load: H 20, Features Intersected: MILL CREEK, Facility Carried by Structure: DUPONT HWY Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.708, Lanes on structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 22.9m (75.1ft), Skew: 20 degrees, Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 1, Length of Maximum Span: 12.2m (40.0ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 0.0m, Curb-To-Curb Width: 22.9m (75.1ft), Out-to-Out Width: 25.3m (83.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Channel: Very good, Operating Rating: 61.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 37.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2006, Bridge Improvement Cost: $800,000, Roadway Improvement Cost: $200,000, Total Project Cost: $1,000,000 ( Estimate for 2005), Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2001C001, Location: SMYRNA (Lat: 39.308889, Lng: -75.609167), Route carried "on" structure: US 13, Year Built: 1995, Status: Open, Structure Length: 3.29m (10.79ft), Average Daily Traffic: 24,090 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 13,490 (year 2014), Design Load: HS 25, Features Intersected: SMYRNA RIVER/DUCK CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.253, Lanes on structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 24.4m (80.1ft), Skew: 20 degrees, Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 2, Length of Maximum Span: 15.6m (51.2ft), Curb-To-Curb Width: 24.4m (80.1ft), Out-to-Out Width: 25.1m (82.3ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Channel: Very good, Operating Rating: 72.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 43.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 48 months, Inspection Date: July 2007, Bridge Improvement Cost: $1,000, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 2012C012, Location: SOUTH SMYRNA (Lat: 39.291525, Lng: -75.593397), Route carried "on" structure: County highway 12, Year Built: 1991, Status: Open, Structure Length: 6.62m (21.72ft), Average Daily Traffic: 781 (year 2005), Truck Traffic: 13%, Average Future Daily Traffic: 848 (year 2015), Design Load: HS 25, Features Intersected: SR 1, Facility Carried by Structure: SMYRNA-LEIPSIC RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 9.914, Lanes on structure: 2, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 12.3m (40.4ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 32.0m (105.0ft), Curb-To-Curb Width: 13.4m (44.0ft), Out-to-Out Width: 14.2m (46.6ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Very good, Operating Rating: 89.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 82.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: November 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 2064A076, Location: EAST OF SMYRNA (Lat: 39.308297, Lng: -75.593981), Route carried "on" structure: County highway 64, Year Built: 1998, Status: Open, Structure Length: 3.20m (10.50ft), Average Daily Traffic: 571 (year 2005), Truck Traffic: 6%, Design Load: HS 25, Features Intersected: DUCK CREEK, Facility Carried by Structure: SMYRNA LANDING RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.161, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 7.0m (23.0ft), Material/Design: Prestressed concrete, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 2, Length of Maximum Span: 15.2m (49.9ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.5m (4.9ft), Curb-To-Curb Width: 8.4m (27.6ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Very good, Channel: Satisfactory, Operating Rating: 54.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Better than present minimum criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 48 months, Inspection Date: November 2006, Bridge Improvement Cost: $1,000, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 2065A065, Location: NORTH SMYRNA (Lat: 39.308889, Lng: -75.621389), Route carried "on" structure: County highway 65, Year Built: 1960, Status: Open, Structure Length: 0.98m (3.22ft), Average Daily Traffic: 4,751 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 3,070 (year 2014), Design Load: HS 20, Features Intersected: DUCK CREEK Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 2.414, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 10.4m (34.1ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 3.0m (9.8ft), Curb-To-Curb Width: 10.4m (34.1ft), Out-to-Out Width: 11.0m (36.1ft) Condition: Channel: Fair, Culverts: Very good, Operating Rating: 57.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 34.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007 Find on map >>
Structure Number: 2065C065, Location: SMYRNA (Lat: 39.296767, Lng: -75.600367), Route carried "on" structure: County highway 65, Year Built: 1982, Status: Open, Structure Length: 0.64m (2.10ft), Average Daily Traffic: 5,453 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 5,353 (year 2017), Design Load: HS 20, Features Intersected: LAKE COMO SPILLWAY, Facility Carried by Structure: MAIN ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.100, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 11.0m (36.1ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 3.0m (9.8ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 11.0m (36.1ft), Out-to-Out Width: 14.6m (47.9ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 64.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 38.3 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007 Find on map >>
Structure Number: 2137B137, Location: SOUTH OF SMYRNA (Lat: 39.286667, Lng: -75.610556), Route carried "on" structure: County highway 137, Year Built: 1970, Status: Open, Structure Length: 0.94m (3.08ft), Average Daily Traffic: 4,983 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 2,755 (year 2016), Design Load: HS 20, Features Intersected: MILL CREEK, Facility Carried by Structure: CARTER RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.867, Lanes on structure: 2, Owner: State Highway Agency, Approaching Roadway Width: 6.5m (21.3ft), Skew: 2 degrees, Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 2, Length of Maximum Span: 4.3m (14.1ft), Curb-To-Curb Width: 11.6m (38.1ft), Out-to-Out Width: 12.2m (40.0ft) Condition: Channel: Very good, Culverts: Good, Operating Rating: 47.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 28.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 2916N15, Location: EAST OF SMYRNA (Lat: 39.297431, Lng: -75.593314), Route carried "on" structure: State highway 1, Year Built: 1993, Status: Open, Structure Length: 11.97m (39.27ft), Average Daily Traffic: 20,525 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 5,460 (year 2014), Design Load: HS 25, Features Intersected: MILL CREEK, Facility Carried by Structure: KOREAN WAR VET MEM Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 23.706, Lanes on structure: 2, Base Highway Network: Yes, Toll: On toll road, Owner: State Highway Agency, Approaching Roadway Width: 13.7m (44.9ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 19.6m (64.3ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 15.4m (50.5ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Channel: Very good, Operating Rating: 89.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 54.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: July 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 2916S15, Location: EAST OF SMYRNA (Lat: 39.297258, Lng: -75.593489), Route carried "on" structure: State highway 1, Year Built: 1993, Status: Open, Structure Length: 11.97m (39.27ft), Average Daily Traffic: 20,525 (year 2006), Truck Traffic: 7%, Average Future Daily Traffic: 5,460 (year 2014), Design Load: HS 25, Features Intersected: MILL CREEK, Facility Carried by Structure: KOREAN WAR VET HWY Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 22.901, Lanes on structure: 2, Base Highway Network: Yes, Toll: On toll road, Owner: State Highway Agency, Approaching Roadway Width: 14.6m (47.9ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 19.6m (64.3ft), Curb-To-Curb Width: 14.6m (47.9ft), Out-to-Out Width: 15.4m (50.5ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Channel: Very good, Operating Rating: 89.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 54.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Integral Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: 1464 03, Location: NORTH OF SMYRNA (Lat: 39.322208, Lng: -75.609653), Route carried "under" structure: State highway 1, Year Built: 1990, Structure Length: 6.51m (21.36ft), Average Daily Traffic: 41,089 (year 2005), Truck Traffic: 14%, Features Intersected: SR 1, Facility Carried by Structure: PADDOCK RD. Minimum Vertical Clearance: 5.07m (16.63ft), Kilometerpoint: 4.265, Lanes on structure: 2, Lanes under structure: 4, Toll: On toll road, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.0m (105.0ft) Find on map >>
Structure Number: 1914N08, Location: NORTH OF SMYRNA (Lat: 39.330178, Lng: -75.624603), Route carried "under" structure: US 13, Year Built: 1993, Structure Length: 10.52m (34.51ft), Average Daily Traffic: 22,058 (year 2005), Truck Traffic: 12%, Features Intersected: US 13 (DUPONT BLVD), Facility Carried by Structure: KOREAN VET MEM HWY Minimum Vertical Clearance: 5.53m (18.14ft), Kilometerpoint: 2.752, Lanes on structure: 2, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 50.3m (165.0ft) Find on map >>
Structure Number: 1914S08, Location: NORTH OF SMYRNA (Lat: 39.330247, Lng: -75.625297), Route carried "under" structure: US 13, Year Built: 1993, Structure Length: 10.52m (34.51ft), Average Daily Traffic: 22,058 (year 2005), Truck Traffic: 12%, Features Intersected: US 13 (DUPONT BLVD), Facility Carried by Structure: KOREAN VET MEM HWY Minimum Vertical Clearance: 5.65m (18.54ft), Kilometerpoint: 0.209, Lanes on structure: 2, Lanes under structure: 3, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 50.3m (165.0ft) Find on map >>
Structure Number: 2012C012, Location: SOUTH SMYRNA (Lat: 39.291525, Lng: -75.593397), Route carried "under" structure: State highway 1, Year Built: 1991, Structure Length: 6.62m (21.72ft), Average Daily Traffic: 37,747 (year 2003), Truck Traffic: 11%, Features Intersected: SR 1, Facility Carried by Structure: SMYRNA-LEIPSIC RD Minimum Vertical Clearance: 5.12m (16.80ft), Kilometerpoint: 2.218, Lanes on structure: 2, Lanes under structure: 4, Toll: On toll road, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.0m (105.0ft) Discuss this city on our hugely popular Delaware forum Back to: Smyrna, DE, Delaware, All US cities.
|
![]() |