![]() |
Bridge Statistics for Stevens Point, Wisconsin (WI) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Stevens Point, WI, Wisconsin, Wisconsin forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 14 Total length: 90 meters (295ft) Total average daily traffic: 98,035 Total average daily truck traffic: 6,765 National Bridge Inventory (NBI) Registered Bridges for Stevens Point
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Find on map >>
Structure Number: B490031, Location: 4.5M S JCT CTH X TO E (Lat: 44.548119, Lng: -89.570017), Route carried "on" structure: Interstate 39, Year Built: 1969, Status: Open, Structure Length: 4.14m (13.58ft), Average Daily Traffic: 9,400 (year 2005), Truck Traffic: 15%, Average Future Daily Traffic: 18,400 (year 2025), Design Load: HS 20, Features Intersected: LRD RESERVE ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.0m (36.1ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 18.4m (60.4ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 13.1m (43.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 48.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 28.8 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B490032, Location: 1.7M N JCT USH 10 TO W (Lat: 44.548114, Lng: -89.576331), Route carried "on" structure: Business US 51, Year Built: 1969, Status: Open, Structure Length: 6.46m (21.19ft), Average Daily Traffic: 13,565 (year 2005), Truck Traffic: 7%, Average Future Daily Traffic: 16,300 (year 2025), Design Load: HS 20, Features Intersected: IH USH 51-IH 39 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 4, Owner: State Highway Agency, Approaching Roadway Width: 9.8m (32.2ft), Skew: 21 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 2, Length of Maximum Span: 33.8m (110.9ft), Curb or Sidewalk Widths: Left: 0.6m (2.0ft), Right: 0.6m (2.0ft), Curb-To-Curb Width: 19.5m (64.0ft), Out-to-Out Width: 21.5m (70.5ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Satisfactory, Operating Rating: 38.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 22.7 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: B490039, Location: 1.7M N JCT STH 66 TO E (Lat: 44.548472, Lng: -89.569494), Route carried "on" structure: Interstate 39, Year Built: 1969, Status: Open, Structure Length: 4.14m (13.58ft), Average Daily Traffic: 9,200 (year 2005), Truck Traffic: 15%, Average Future Daily Traffic: 18,400 (year 2025), Design Load: HS 20, Features Intersected: LRD RESERVE ST Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 18.4m (60.4ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 13.1m (43.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 42.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B490061, Location: 0.5M W JCT USH 10 (Lat: 44.518808, Lng: -89.607314), Route carried "on" structure: City street , Year Built: 1971, Status: Open, Structure Length: 4.17m (13.68ft), Average Daily Traffic: 1,100 (year 2005), Average Future Daily Traffic: 1,100 (year 2025), Design Load: H 20, Features Intersected: ROCKY RUN CREEK, Facility Carried by Structure: LRD W ZINDA DR Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 11.6m (38.1ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 3, Length of Maximum Span: 16.9m (55.4ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 11.6m (38.1ft), Out-to-Out Width: 12.5m (41.0ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Fair, Operating Rating: 56.7 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 60 months, Inspection Date: October 2006, Underwater Inspection Date: November 2002, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B49009, Location: 1.0M E JCT CTH P (Lat: 44.500669, Lng: -89.596167), Route carried "on" structure: County highway , Year Built: 1999, Status: Open, Structure Length: 23.72m (77.82ft), Average Daily Traffic: 3,700 (year 2005), Average Future Daily Traffic: 13,500 (year 2025), Design Load: HS 20, Features Intersected: WISCONSIN RIVER, Facility Carried by Structure: CTH HH Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: County Highway Agency, Approaching Roadway Width: 25.3m (83.0ft), Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 7, Length of Maximum Span: 34.0m (111.5ft), Curb or Sidewalk Widths: Left: 1.0m (3.3ft), Right: 1.0m (3.3ft), Curb-To-Curb Width: 23.1m (75.8ft), Out-to-Out Width: 23.7m (77.8ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Satisfactory, Operating Rating: 71.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 36.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Underwater Inspection Frequency: Every 60 months, Inspection Date: May 2006, Underwater Inspection Date: June 2005, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B490091, Location: 1.2M W JCT CTH P (Lat: 44.500769, Lng: -89.591244), Route carried "on" structure: County highway , Year Built: 1999, Status: Open, Structure Length: 4.64m (15.22ft), Average Daily Traffic: 99 (year 2005), Average Future Daily Traffic: 99 (year 2024), Design Load: HS 20, Features Intersected: WISCONSIN RIVER, Facility Carried by Structure: CTH HH Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: County Highway Agency, Approaching Roadway Width: 24.4m (80.1ft), Skew: 1 degrees, Material/Design: Prestressed concrete continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 15.3m (50.2ft), Curb or Sidewalk Widths: Left: 1.8m (5.9ft), Right: 1.8m (5.9ft), Curb-To-Curb Width: 23.1m (75.8ft), Out-to-Out Width: 23.7m (77.8ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Very good, Operating Rating: 68.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 39.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present desirable criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B490093, Location: 0.4M E JCT CTH P (Lat: 44.521631, Lng: -89.589833), Route carried "on" structure: US 10, Year Built: 2000, Status: Open, Structure Length: 16.52m (54.20ft), Average Daily Traffic: 7,001 (year 2005), Truck Traffic: 3%, Average Future Daily Traffic: 13,800 (year 2023), Design Load: HS 20, Features Intersected: WISCONSIN RIVER 23 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Base Highway Network: Yes, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 15.5m (50.9ft), Skew: 10 degrees, Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 41.0m (134.5ft), Curb or Sidewalk Widths: Left: 2.4m (7.9ft), Right: 2.4m (7.9ft), Curb-To-Curb Width: 18.0m (59.1ft), Out-to-Out Width: 25.8m (84.6ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 84.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 36.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete, Deck Protection: Epoxy Coated Reinforcing Find on map >>
Structure Number: B490138, Location: 1.4M E JCT CTH E TO S (Lat: 44.523372, Lng: -89.606236), Route carried "on" structure: US 10, Year Built: 2006, Status: Open, Structure Length: 3.12m (10.24ft), Average Daily Traffic: 8,200 (year 2006), Average Future Daily Traffic: 13,600 (year 2026), Design Load: HS 20, Features Intersected: WISCONSIN RIVER OVRFLW Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 13.4m (44.0ft), Material/Design: Concrete continuous, Design/Construction: Slab, Number Of Spans In Main Unit: 2, Length of Maximum Span: 15.2m (49.9ft), Curb-To-Curb Width: 13.4m (44.0ft), Out-to-Out Width: 14.2m (46.6ft) Condition: Deck: Excellent, Superstructure: Excellent, Substructure: Excellent, Operating Rating: 59.9 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 35.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Superior to present desirable criteria, Deck Geometry: Equal to present minimum criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: September 2006, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: P490708, Location: 2.6M E JCT USH 51B (Lat: 44.511881, Lng: -89.541928), Route carried "on" structure: City street , Year Built: 1981, Status: Open, Structure Length: 4.61m (15.12ft), Average Daily Traffic: 1,010 (year 2005), Average Future Daily Traffic: 1,010 (year 2025), Design Load: HS 20, Features Intersected: PLOVER RIVER, Facility Carried by Structure: LRD PATCH STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 15.8m (51.8ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 15.4m (50.5ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 15.8m (51.8ft), Out-to-Out Width: 18.3m (60.0ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Fair, Operating Rating: 66.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 38.9 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: B490031, Location: 1.5M N JCT STH 66 (Lat: 44.548119, Lng: -89.570017), Route carried "under" structure: City street , Year Built: 1969, Structure Length: 4.14m (13.58ft), Average Daily Traffic: 3,050 (year 2005), Features Intersected: LRD RESERVE ST, Facility Carried by Structure: IH USH51-IH39SB Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Concrete continuous, Design/Construction: Slab, Length of Maximum Span: 18.4m (60.4ft) Find on map >>
Structure Number: B490032, Location: 2.0M N JCT STH 66 TO E (Lat: 44.548114, Lng: -89.576331), Route carried "under" structure: Interstate 39, Year Built: 1969, Structure Length: 6.46m (21.19ft), Average Daily Traffic: 17,600 (year 2005), Truck Traffic: 16%, Features Intersected: IH USH 51-IH 39, Facility Carried by Structure: USH B51 NB Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 4, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 33.8m (110.9ft) Find on map >>
Structure Number: B490039, Location: 1.5M N JCT STH 66 (Lat: 44.548472, Lng: -89.569494), Route carried "under" structure: City street , Year Built: 1969, Structure Length: 4.14m (13.58ft), Average Daily Traffic: 3,050 (year 2005), Features Intersected: LRD RESERVE ST, Facility Carried by Structure: IH USH51-IH39NB Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 2, Material/Design: Concrete continuous, Design/Construction: Slab, Length of Maximum Span: 18.4m (60.4ft) Structure Number: B490066, Location: 0.6M S JCT USH 10 TO E, Route carried "under" structure: City street , Year Built: 1981, Structure Length: 2.24m (7.35ft), Average Daily Traffic: 7,850 (year 2005), Features Intersected: LRD MICHIGAN AVE, Facility Carried by Structure: SOO LINE
Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 20.8m (68.2ft) Find on map >>
Structure Number: B490435, Location: 4.5M N JCT STH 54 TO W (Lat: 44.512919, Lng: -89.573236), Route carried "under" structure: Business US 51, Year Built: 1939, Structure Length: 2.11m (6.92ft), Average Daily Traffic: 13,210 (year 2005), Features Intersected: USH B51-CHURCH ST, Facility Carried by Structure: CENTRAL WISC. LIMI Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Girder and Floorbeam System, Length of Maximum Span: 20.2m (66.3ft) Discuss this city on our hugely popular Wisconsin forum Back to: Stevens Point, WI, Wisconsin, All US cities.
|
![]() |