U.S. Cities - City-Data Homepage  
City-Data Forum
City-Data.com Homepage

Bridge Statistics for Summit, Wisconsin (WI) - Condition, Traffic, Stress, Structural Evaluation, Project Costs

Back to: Summit, WI, Wisconsin, Wisconsin forum, All US cities.





National Bridge Inventory (NBI) Statistics
Number of bridges: 33
Total length: 133 meters (436ft)
Total costs: $238,000
Total average daily traffic: 475,080
Total average daily truck traffic: 49,943
National Bridge Inventory (NBI) Registered Bridges for Summit

New bridges - Historical Statistics

  • 1910-1919: 1
  • 1920-1929: 1
  • 1930-1939: 1
  • 1940-1949: 1
  • 1950-1959: 2
  • 1960-1969: 20
  • 1970-1979: 2
  • 1980-1989: 0
  • 1990-1999: 1
  • 2000-2009: 4

Reconstructed bridges - Historical Statistics

  • 1950-1959: 2
  • 1960-1969: 0
  • 1970-1979: 1
  • 1980-1989: 0
  • 1990-1999: 5

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Culverts

Structure Number: B670003,  Location: 0.3M E JCT CTH P,  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 3,180 (year 2005),  Average Future Daily Traffic: 3,180 (year 2025),  Design Load: HS 20,  Features Intersected: BARK RIVER,  Facility Carried by Structure: CTH DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.0m (39.4ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.5m (44.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B670006,  Location: 0.8M N JCT CTH B,  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.38m (4.53ft),  Average Daily Traffic: 2,435 (year 2005),  Average Future Daily Traffic: 4,410 (year 2025),  Design Load: HS 20,  Features Intersected: OCONOMOWOC RIVER,  Facility Carried by Structure: CTH BB (GOLDEN LAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B67001,  Location: 0.2M N JCT USH 18,  Route carried "on" structure: State highway 67,  Year Built: 1953,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 8,370 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,310 (year 2023),  Design Load: H 15,  Features Intersected: BARK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: B670011,  Location: 0.5M E JCT STH 67,  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 105 (year 2005),  Truck Traffic: 2%,  Average Future Daily Traffic: 175 (year 2025),  Design Load: HS 20,  Features Intersected: BARK RIVER,  Facility Carried by Structure: LRD GENESSE LAKE R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 59.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: B670025,  Location: 1.9M E JCT CTH BB (Lat: 43.021667,  Lng: -88.496667),  Route carried "on" structure: US 18,  Year Built: 1955,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 2,350 (year 2005),  Truck Traffic: 8%,  Average Future Daily Traffic: 2,890 (year 2023),  Design Load: HS 20,  Features Intersected: BARK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: B670026,  Location: 2.6M E JCT CTH BB (Lat: 43.023333,  Lng: -88.485000),  Route carried "on" structure: US 18,  Year Built: 1919,  Year Reconstructed: 1955,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 3,800 (year 2005),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,360 (year 2023),  Design Load: H 20,  Features Intersected: BARK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: B670027,  Location: 3.6M E JCT CTH BB (Lat: 43.023333,  Lng: -88.465000),  Route carried "on" structure: US 18,  Year Built: 1924,  Year Reconstructed: 1955,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 6,300 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,230 (year 2023),  Design Load: H 20,  Features Intersected: BARK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 43.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: B670067,  Location: 2.7M E JCT STH 67 TO N (Lat: 43.056667,  Lng: -88.425000),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 23,925 (year 2005),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,770 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: LRD WATERVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B670068,  Location: 2.9M W JCT STH 83 TO N (Lat: 43.056667,  Lng: -88.425000),  Route carried "on" structure: Interstate 94,  Year Built: 1963,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 3.88m (12.73ft),  Average Daily Traffic: 28,700 (year 2005),  Truck Traffic: 12%,  Average Future Daily Traffic: 53,290 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: LRD WATERVILLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B670069,  Location: 2.3M E JCT STH 67 TO N (Lat: 43.058333,  Lng: -88.433333),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 38.74m (127.10ft),  Average Daily Traffic: 23,925 (year 2005),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,770 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: NEMAHBIN LAKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 26,  Length of Maximum Span: 14.3m (46.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B670076,  Location: 3.9M W JCT STH 83 TO N (Lat: 43.061667,  Lng: -88.441667),  Route carried "on" structure: Interstate 94,  Year Built: 1963,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 26,450 (year 2005),  Truck Traffic: 12%,  Average Future Daily Traffic: 49,395 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: CTH P SAWYER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.8m (48.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B670077,  Location: 1.8M E JCT STH 67 TO N (Lat: 43.061667,  Lng: -88.441667),  Route carried "on" structure: Interstate 94,  Year Built: 1963,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 26,450 (year 2005),  Truck Traffic: 12%,  Average Future Daily Traffic: 49,395 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: CTH P SAWYER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.8m (48.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: B670078,  Location: 3.3M N JCT USH 18 (Lat: 43.068333,  Lng: -88.471667),  Route carried "on" structure: State highway 67,  Year Built: 1963,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 10,310 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,810 (year 2023),  Design Load: HS 20,  Features Intersected: IH 94
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>

Structure Number: B670079,  Location: 5.9M E JCT STH 135 TO N (Lat: 43.068333,  Lng: -88.481667),  Route carried "on" structure: Interstate 94,  Year Built: 1964,  Status: Open,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 25,250 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 39,100 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: LRD DOUSMAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.5m (47.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B67008,  Location: 0.7M W JCT STH 67 TO N (Lat: 43.068333,  Lng: -88.481667),  Route carried "on" structure: Interstate 94,  Year Built: 1964,  Status: Open,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 25,250 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 39,100 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: LRD DOUSMAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.5m (47.6ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B670081,  Location: 3.9M E JCT STH 135 TO N (Lat: 43.070000,  Lng: -88.520000),  Route carried "on" structure: Interstate 94,  Year Built: 1964,  Status: Open,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 25,250 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 39,100 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: CTH BB GOLDEN LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.6m (41.3ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B670082,  Location: 2.7M W JCT STH 67 TO N (Lat: 43.070000,  Lng: -88.520000),  Route carried "on" structure: Interstate 94,  Year Built: 1964,  Status: Open,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 25,250 (year 2006),  Truck Traffic: 9%,  Average Future Daily Traffic: 39,100 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: CTH BB GOLDEN LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.6m (41.3ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>

Structure Number: B670083,  Location: 2.9M E JCT STH 135 TO N (Lat: 43.070000,  Lng: -88.540000),  Route carried "on" structure: Interstate 94,  Year Built: 1964,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 50,500 (year 2006),  Truck Traffic: 13%,  Average Future Daily Traffic: 41,400 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: BATTLE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Culverts: Satisfactory,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: B670188,  Location: 0.5M S JCT CTH B (Lat: 43.068333,  Lng: -88.471667),  Route carried "on" structure: State highway 67,  Year Built: 1976,  Status: Open,  Structure Length: 6.61m (21.69ft),  Average Daily Traffic: 6,950 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,409 (year 2023),  Design Load: HS 20,  Features Intersected: IH 94
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2007,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: B670222,  Location: 3.2M W JCT STH 83 TO N (Lat: 44.556667,  Lng: -88.053333),  Route carried "on" structure: Interstate 94,  Year Built: 1990,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 32,450 (year 2005),  Truck Traffic: 12%,  Average Future Daily Traffic: 47,310 (year 2023),  Design Load: HS 20,  Features Intersected: NEMAHBIN LAKE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Structure Number: B670291,  Location: 0.1M N JCT CTH CCC,  Route carried "on" structure: City street ,  Year Built: 2005,  Status: Open,  Structure Length: 2.03m (6.66ft),  Average Daily Traffic: 2,320 (year 2004),  Average Future Daily Traffic: 3,450 (year 2024),  Design Load: HS 25,  Features Intersected: BARK RIVER,  Facility Carried by Structure: LRD MILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 76.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B67067,  Location: 0.7M W JCT CTH BB,  Route carried "on" structure: City street ,  Year Built: 1941,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 300 (year 2005),  Average Future Daily Traffic: 300 (year 2025),  Design Load: HS 20,  Features Intersected: BATTLE CREEK,  Facility Carried by Structure: LRD DELAFIELD RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Structure Number: B670959,  Location: 0.2M S JCT CTH DR,  Route carried "on" structure: County highway ,  Year Built: 1932,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 4,040 (year 2005),  Average Future Daily Traffic: 4,040 (year 2025),  Design Load: H 15,  Features Intersected: BARK RIVER,  Facility Carried by Structure: CTH P (SAWYER RD)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 8.2m (26.9ft)

Condition: Culverts: Poor,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.28m (4.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2006,  Bridge Improvement Cost: $158,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $238,000 ( Estimate for 2007),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: B670067,  Location: 0.1M S JCT CTH DR (Lat: 43.056667,  Lng: -88.425000),  Route carried "under" structure: City street ,  Year Built: 1962,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 160 (year 2005),  Features Intersected: LRD WATERVILLE RD,  Facility Carried by Structure: IH 94 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: B670068,  Location: 0.1M S JCT CTH DR (Lat: 43.056667,  Lng: -88.425000),  Route carried "under" structure: City street ,  Year Built: 1963,  Structure Length: 3.88m (12.73ft),  Average Daily Traffic: 160 (year 2005),  Features Intersected: LRD WATERVILLE RD,  Facility Carried by Structure: IH 94 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: B670076,  Location: 3.8M N JCT USH 18 (Lat: 43.061667,  Lng: -88.441667),  Route carried "under" structure: County highway ,  Year Built: 1963,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 5,300 (year 2005),  Features Intersected: CTH P SAWYER RD,  Facility Carried by Structure: IH 94 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.8m (48.6ft)

Find on map >>

Structure Number: B670077,  Location: 2.8M N JCT USH 18 (Lat: 43.061667,  Lng: -88.441667),  Route carried "under" structure: County highway ,  Year Built: 1963,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 5,300 (year 2005),  Features Intersected: CTH P SAWYER RD,  Facility Carried by Structure: IH 94 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.8m (48.6ft)

Find on map >>

Structure Number: B670078,  Location: 6.4M E JCT STH 135 TO N (Lat: 43.068333,  Lng: -88.471667),  Route carried "under" structure: Interstate 94,  Year Built: 1963,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 47,850 (year 2005),  Truck Traffic: 13%,  Features Intersected: IH 94,  Facility Carried by Structure: STH 67 NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>

Structure Number: B670079,  Location: 0.4M N JCT CTH DR (Lat: 43.068333,  Lng: -88.481667),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 1,200 (year 2005),  Features Intersected: LRD DOUSMAN RD,  Facility Carried by Structure: IH 94 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.5m (47.6ft)

Find on map >>

Structure Number: B67008,  Location: 0.4M N JCT CTH DR (Lat: 43.068333,  Lng: -88.481667),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 1,200 (year 2005),  Features Intersected: LRD DOUSMAN RD,  Facility Carried by Structure: IH 94 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.5m (47.6ft)

Find on map >>

Structure Number: B670081,  Location: 0.9M S JCT CTH B (Lat: 43.070000,  Lng: -88.520000),  Route carried "under" structure: County highway ,  Year Built: 1964,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 1,100 (year 2005),  Features Intersected: CTH BB GOLDEN LAKE RD,  Facility Carried by Structure: IH 94 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 12.6m (41.3ft)

Find on map >>

Structure Number: B670082,  Location: 0.9M S JCT CTH B (Lat: 43.070000,  Lng: -88.520000),  Route carried "under" structure: County highway ,  Year Built: 1964,  Structure Length: 3.16m (10.37ft),  Average Daily Traffic: 1,100 (year 2005),  Features Intersected: CTH BB GOLDEN LAKE RD,  Facility Carried by Structure: IH 94 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 12.6m (41.3ft)

Find on map >>

Structure Number: B670188,  Location: 6.3M E JCT STH 135 TO N (Lat: 43.068333,  Lng: -88.471667),  Route carried "under" structure: Interstate 94,  Year Built: 1976,  Structure Length: 6.61m (21.69ft),  Average Daily Traffic: 47,850 (year 2005),  Truck Traffic: 13%,  Features Intersected: IH 94,  Facility Carried by Structure: STH 67 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Discuss this city on our hugely popular Wisconsin forum

Back to: Summit, WI, Wisconsin, All US cities.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2009 Advameg, Inc.