Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Three Rivers, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 27Number of bridges
  • 305ft / 92.7mTotal length
  • $975,000Total costs
  • 84,741Total average daily traffic
  • 4,796Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Three Rivers
  • No street view available for this location

New bridges in Three Rivers, MI - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 11940-1949
  • 31950-1959
  • 71960-1969
  • 41970-1979
  • 71980-1989
  • 32000-2009
  • 12010-2019
Reconstructed bridges in Three Rivers, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Three Rivers, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 12.0%Very good
  • 16.0%Good
  • 52.0%Satisfactory
  • 20.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 11.5%Very good
  • 7.7%Good
  • 50.0%Satisfactory
  • 26.9%Fair
  • 3.8%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 15.4%Very good
  • 30.8%Good
  • 34.6%Satisfactory
  • 7.7%Fair
  • 7.7%Poor
  • 3.8%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.0%Very good
  • 28.0%Good
  • 36.0%Satisfactory
  • 32.0%Fair
Find on map >>   Show street view

Structure Number: 1027,  Location: 2 MI NE OF SODUS (Lat: 42.057903,  Lng: -86.354733),  Route carried "on" structure: County highway ,  Year Built: 2002,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 381 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 550 (year 2027),  Design Load: HS 20,  Features Intersected: PIPESTONE CREEK,  Facility Carried by Structure: WATSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.357,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1039,  Location: 0.5 MI S OF NEW TROY (Lat: 41.870783,  Lng: -86.543603),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Posted for load,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 212 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 300 (year 2027),  Design Load: H 20,  Features Intersected: EAST BRANCH GALIEN RIVER,  Facility Carried by Structure: LOG CABIN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.274,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 14.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 6.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10264,  Location: 0.3 MI W OF THREE RIVERS (Lat: 41.954997,  Lng: -85.645997),  Route carried "on" structure: US 131,  Year Built: 1951,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 9,588 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 10,588 (year 2037),  Design Load: HS 20,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.639,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 23,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 71.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10265,  Location: 0.3 MI W OF THREE RIVERS (Lat: 41.955053,  Lng: -85.646147),  Route carried "on" structure: US 131,  Year Built: 1956,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 9,588 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 10,588 (year 2037),  Design Load: HS 20,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.819,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 191,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 14.1m (46.3ft),  Out-to-Out Width: 15.1m (49.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1027,  Location: IN THREE RIVERS (Lat: 41.943094,  Lng: -85.634656),  Route carried "on" structure: State highway 60,  Year Built: 1966,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 9,299 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 14,893 (year 2018),  Design Load: HS 20,  Features Intersected: ROCKY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.481,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10271,  Location: IN THREE RIVERS(195 W MI) (Lat: 41.943328,  Lng: -85.634011),  Route carried "on" structure: State highway 60,  Year Built: 1942,  Status: Open,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 9,299 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 14,893 (year 2018),  Design Load: H 20,  Features Intersected: ROCKY RIVER RACE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.421,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.9m (35.8ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 22.9m (75.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10272,  Location: IN THREE RIVERS (E MICH) (Lat: 41.944422,  Lng: -85.631331),  Route carried "on" structure: State highway 60,  Year Built: 1925,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 4,978 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,572 (year 2018),  Design Load: H 15,  Features Intersected: PORTAGE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.741,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete continuous,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10281,  Location: IN THREE RIVERS (Lat: 41.943011,  Lng: -85.631883),  Route carried "on" structure: State highway 86,  Year Built: 2000,  Status: Open,  Structure Length: 5.53m (18.14ft),  Average Daily Traffic: 6,441 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,116 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: ST JOSEPH RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.084,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.4m (60.4ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 89.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: July 2021,  Underwater Inspection Date: August 2017,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10287,  Location: 1.0 MI W OF US-131 (Lat: 42.027561,  Lng: -85.652114),  Route carried "on" structure: State highway 216,  Year Built: 1989,  Status: Open,  Structure Length: 1.30m (4.27ft),  Average Daily Traffic: 3,379 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,479 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: FLOWERFIELD CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.225,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.0m (42.7ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.5m (47.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10293,  Location: 1.5 MI NE OF THREE RIVERS (Lat: 41.976711,  Lng: -85.601408),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Posted for load,  Structure Length: 2.92m (9.58ft),  Average Daily Traffic: 1,311 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,786 (year 2023),  Design Load: HS 20,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: S FISHER LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.141,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Serious,  Channel: Fair,  Operating Rating: 22.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 16.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10297,  Location: SW OF MOOREPARK (Lat: 42.005700,  Lng: -85.646139),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 419 (year 2014),  Truck Traffic: 6%,  Average Future Daily Traffic: 511 (year 2034),  Design Load: Greater than HL93,  Features Intersected: ROCKY RIVER,  Facility Carried by Structure: FLOATING BRIDGE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.923,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.0m (88.6ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 90.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1031,  Location: 3 MI EAST OF THREE RIVERS (Lat: 41.965017,  Lng: -85.569192),  Route carried "on" structure: County highway 7835,  Year Built: 1977,  Status: Posted for load,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 1,060 (year 2016),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,171 (year 2036),  Design Load: HS 20,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: SCHWEITZER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.066,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.7m (28.5ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2021,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10326,  Location: 4 MI N OF THREE RIVERS (Lat: 41.998503,  Lng: -85.584939),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 2.19m (7.19ft),  Average Daily Traffic: 1,211 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,700 (year 2023),  Design Load: HS 20,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: HEIMBACH ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.184,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 47.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1034,  Location: 0.75 MI E OF US-131 (Lat: 41.889286,  Lng: -85.648214),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 7.37m (24.18ft),  Average Daily Traffic: 540 (year 2002),  Truck Traffic: 7%,  Average Future Daily Traffic: 798 (year 2023),  Design Load: HS 20,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: WITHERS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.270,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 61.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2021,  Underwater Inspection Date: May 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10355,  Location: 2 MI N OF THREE RIVERS (Lat: 41.983783,  Lng: -85.647914),  Route carried "on" structure: County highway ,  Year Built: 1966,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 506 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 740 (year 2023),  Design Load: H 20,  Features Intersected: ROCKY RIVER,  Facility Carried by Structure: NULL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.323,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 44.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10358,  Location: 2 MI S OF THREE RIVERS (Lat: 41.909417,  Lng: -85.639261),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 7.31m (23.98ft),  Average Daily Traffic: 1,493 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,008 (year 2023),  Design Load: H 20,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: CONSTANTINE STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.071,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 12,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: November 2021,  Underwater Inspection Date: May 2018,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10359,  Location: 2 MI SE OF THREE RIVERS (Lat: 41.903031,  Lng: -85.590536),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 165 (year 1997),  Truck Traffic: 5%,  Average Future Daily Traffic: 245 (year 2017),  Design Load: HS 20,  Features Intersected: PRAIRIE RIVER,  Facility Carried by Structure: NEAMAN ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.761,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.0m (62.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1036,  Location: 2 MI NE OF THREE RIVERS (Lat: 41.980800,  Lng: -85.596236),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 80 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 119 (year 2023),  Design Load: H 20,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: CARPENTER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.478,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 52.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10376,  Location: 5 MI NE OF THREE RIVERS (Lat: 42.008053,  Lng: -85.567217),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 6.09m (19.98ft),  Average Daily Traffic: 341 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 460 (year 2023),  Design Load: HS 20,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: N FISHER LAKE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.221,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1039,  Location: 0.2 MI EAST OF US-131 (Lat: 41.933089,  Lng: -85.635725),  Route carried "on" structure: Business City street 2043,  Year Built: 1968,  Year Reconstructed: 1990,  Status: Posted for load,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 4,900 (year 1991),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,000 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: BROADWAY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.212,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10391,  Location: 0.3 MI EAST OF US-131 BR (Lat: 41.947089,  Lng: -85.628375),  Route carried "on" structure: City street 2043,  Year Built: 1985,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 2,800 (year 1988),  Average Future Daily Traffic: 2,800 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: FIFTH AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.354,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 21.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10392,  Location: JCTN/ E HOFFMAN & WOOD ST (Lat: 41.954703,  Lng: -85.624200),  Route carried "on" structure: City street 2043,  Year Built: 1976,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 4,000 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,000 (year 2038),  Design Load: Greater than HL93,  Features Intersected: PORTAGE RIVER,  Facility Carried by Structure: HOFFMAN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.169,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.4m (30.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.81m (9.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $375,000,  Roadway Improvement Cost: $65,000,  Total Project Cost: $440,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10393,  Location: 0.1 MI E OF US-131 (Lat: 41.954397,  Lng: -85.643725),  Route carried "on" structure: City street 2043,  Year Built: 1960,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 4,600 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,000 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ROCKEY RIVER,  Facility Carried by Structure: HOFFMAN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.547,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 34.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 3.84m (12.60ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Bridge Improvement Cost: $475,000,  Roadway Improvement Cost: $60,000,  Total Project Cost: $535,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 10394,  Location: 0.3 MI EAST OF US-131 (Lat: 41.940228,  Lng: -85.627122),  Route carried "on" structure: City street 2043,  Year Built: 1965,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 2,400 (year 1990),  Average Future Daily Traffic: 2,500 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: SIXTH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.372,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10395,  Location: TWO BLOCKS W OF MAIN ST (Lat: 41.945911,  Lng: -85.637131),  Route carried "on" structure: City street 2043,  Year Built: 1981,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 2,700 (year 1989),  Average Future Daily Traffic: 2,700 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ROCKY RIVER,  Facility Carried by Structure: PEALER STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.816,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10396,  Location: ONE BLOCK W OF MAIN ST (Lat: 41.946025,  Lng: -85.635961),  Route carried "on" structure: City street 2043,  Year Built: 1981,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 2,700 (year 1989),  Average Future Daily Traffic: 2,700 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RAILROAD DR & CONRAIL RR,  Facility Carried by Structure: PEALER STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.901,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.0m,  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.5m (37.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 37.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 15.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10396,  Location: ONE BLOCK W OF MAIN ST (Lat: 41.946025,  Lng: -85.635961),  Route carried "under" structure: ServiceCity street ,  Year Built: 1981,  Structure Length: 0. m,  Average Daily Traffic: 350 (year 1985),  Features Intersected: RAILROAD DR & CONRAIL RR,  Facility Carried by Structure: PEALER STREET
Minimum Vertical Clearance: 8.84m (29.00ft),  Kilometerpoint: 23.608,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 17.0m (55.8ft)

Discuss Three Rivers, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.