National Bridge Inventory (NBI) Statistics
Number of bridges: 55
Total length: 244 meters (801ft)
Total average daily traffic: 1,872,739
Total average daily truck traffic: 125,518
National Bridge Inventory (NBI) Registered Bridges for Troy

New bridges - Historical Statistics

  • 1950-1959: 1
  • 1960-1969: 33
  • 1970-1979: 9
  • 1980-1989: 7
  • 1990-1999: 4
  • 2000-2009: 1

Reconstructed bridges - Historical Statistics

  • 1990-1999: 1
  • 2000-2009: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Bridge Condition - Culverts

Find on map >>

Structure Number: 63163174000S081,  Location: IN TROY (Lat: 42.559164,  Lng: -83.147514),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 56,951 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 57,805 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: LIVERNOIS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.355,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Poor,  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 15 months,  Inspection Date: June 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S082,  Location: IN TROY (Lat: 42.558942,  Lng: -83.147506),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 56,951 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 57,805 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: LIVERNOIS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.313,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S091,  Location: IN TROY (Lat: 42.562097,  Lng: -83.158025),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 56,911 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 59,472 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: BIG BEAVER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.365,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.0m,  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S092,  Location: IN TROY (Lat: 42.562081,  Lng: -83.158350),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 5.27m (17.29ft),  Average Daily Traffic: 56,911 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 59,472 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: BIG BEAVER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.361,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S095,  Location: IN TROY (Lat: 42.562097,  Lng: -83.157806),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 1983,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 12,000 (year 1993),  Truck Traffic: 11%,  Design Load: HS 25,  Features Intersected: BIG BEAVER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.874,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 13.9m (45.6ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63163174000S096,  Location: IN TROY (Lat: 42.562078,  Lng: -83.158503),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 1983,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 6,200 (year 1993),  Truck Traffic: 11%,  Design Load: HS 25,  Features Intersected: BIG BEAVER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.835,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 13.8m (45.3ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63163174000S1,  Location: IN TROY (Lat: 42.576983,  Lng: -83.158961),  Route carried "on" structure: City street 2059,  Year Built: 1964,  Status: Open,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 1,990 (year ),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,990 ,  Design Load: H 20,  Features Intersected: I-75,  Facility Carried by Structure: WATTLES RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.395,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Poor,  Inventory Rating: 44.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 15 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S111,  Location: IN TROY (Lat: 42.591253,  Lng: -83.159269),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 56,911 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 59,472 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: EAST LONG LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.600,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 63.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S112,  Location: IN TROY (Lat: 42.591244,  Lng: -83.159581),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 56,911 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 59,472 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: EAST LONG LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.595,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 89.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 63.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S12,  Location: IN TROY (Lat: 42.599533,  Lng: -83.162544),  Route carried "on" structure: Business Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 3,900 (year 1977),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,900 ,  Design Load: HS 20+Mod,  Features Intersected: I-75,  Facility Carried by Structure: RAMP CONNTO CHRYSL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.708,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.3m (79.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 85.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>

Structure Number: 63163174000S13,  Location: IN TROY (Lat: 42.604522,  Lng: -83.168997),  Route carried "on" structure: County highway 2059,  Year Built: 1990,  Status: Open,  Structure Length: 8.59m (28.18ft),  Average Daily Traffic: 21,500 (year 1990),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,500 (year 2010),  Design Load: H 20,  Features Intersected: I-75,  Facility Carried by Structure: N.B. CROOKS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.340,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 65,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.9m (94.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 32.7 metric tons,  Inventory Rating: 32.7 metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63163174000S141,  Location: IN TROY (Lat: 42.604964,  Lng: -83.188828),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 52,297 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,219 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: COOLIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.017,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 81.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S142,  Location: IN TROY (Lat: 42.604731,  Lng: -83.188828),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 52,297 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,219 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: COOLIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.973,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 81.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S151,  Location: IN TROY (Lat: 42.606083,  Lng: -83.205431),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.81m (15.78ft),  Average Daily Traffic: 52,297 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,219 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: SQUARE LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.399,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.8m (74.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.82m (15.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S152,  Location: IN TROY (Lat: 42.605886,  Lng: -83.205703),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.81m (15.78ft),  Average Daily Traffic: 52,297 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,219 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: SQUARE LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.378,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.8m (74.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.82m (15.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S161,  Location: IN TROY (OVER ADAMS RD) (Lat: 42.606767,  Lng: -83.208553),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 52,740 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,696 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ADAMS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.666,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 89.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63163174000S162,  Location: IN TROY (OVER ADAMS RD) (Lat: 42.606511,  Lng: -83.208542),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Status: Open,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 52,740 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 56,696 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: ADAMS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.621,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 12 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 18.2m (59.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 86.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 70.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63163174000S211,  Location: IN TROY (OVER MAPLE RD) (Lat: 42.548986,  Lng: -83.116586),  Route carried "on" structure: Interstate 75,  Year Built: 1963,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 67,882 (year 2003),  Truck Traffic: 6%,  Average Future Daily Traffic: 68,900 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: MAPLE RD, 15 MILE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.972,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Poor,  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 15 months,  Inspection Date: Febuary 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S212,  Location: IN TROY (OVER MAPLE RD) (Lat: 42.548983,  Lng: -83.116900),  Route carried "on" structure: Interstate 75,  Year Built: 1963,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 67,882 (year 2003),  Truck Traffic: 6%,  Average Future Daily Traffic: 68,900 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: MAPLE RD, 15 MILE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.970,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 64,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 15.4m (50.5ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Inventory Rating: 72.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000S32,  Location: IN TROY (Lat: 42.604886,  Lng: -83.169350),  Route carried "on" structure: County highway 2059,  Year Built: 1990,  Status: Open,  Structure Length: 8.59m (28.18ft),  Average Daily Traffic: 21,500 (year 1990),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,500 (year 2010),  Design Load: H 20,  Features Intersected: I-75,  Facility Carried by Structure: S.B. CROOKS RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.305,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 440,  Subroute: 39),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.9m (94.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63200348000B01,  Location: BET FOURTEEN AND MAPLE (Lat: 42.545439,  Lng: -83.107531),  Route carried "on" structure: County highway 2059,  Year Built: 1976,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 33,632 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 38,630 (year 2014),  Design Load: HS 20+Mod,  Features Intersected: BARNARD DRAIN,  Facility Carried by Structure: JOHN R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.942,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 24.3m (79.7ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63200352000B01,  Location: BET LONG LK AND SQ LAKE (Lat: 42.594881,  Lng: -83.109600),  Route carried "on" structure: County highway 2059,  Year Built: 1988,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 14,314 (year 1994),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,000 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: GIBSON DRAIN,  Facility Carried by Structure: JOHN R ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.435,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 24.0m (78.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>

Structure Number: 63200361000B01,  Location: BET WATTLES AND LONG LK R (Lat: 42.586833,  Lng: -83.089672),  Route carried "on" structure: County highway 2059,  Year Built: 2003,  Status: Open,  Structure Length: 0.92m (3.02ft),  Average Daily Traffic: 22,495 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 33,400 (year 2018),  Design Load: HS 20,  Features Intersected: GIBSON DRAIN,  Facility Carried by Structure: DEQUINDRE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.537,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 79,  Subroute: 2),  Owner: County Highway Agency,  Approaching Roadway Width: 19.4m (63.6ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.6m (28.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 19.4m (63.6ft),  Out-to-Out Width: 36.0m (118.1ft)

Condition: Channel: Satisfactory,  Culverts: Excellent,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2006,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 63200686000B01,  Location: EAST OF ROCHESTER (Lat: 42.562922,  Lng: -83.127475),  Route carried "on" structure: County highway 2059,  Year Built: 1975,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 26,470 (year 1996),  Truck Traffic: 5%,  Average Future Daily Traffic: 31,000 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: STURGIS DRAIN,  Facility Carried by Structure: BIG BEAVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.647,  Lanes on structure: 8,  Base Highway Network: Yes (Inventory Route: 440,  Subroute: 43),  Owner: County Highway Agency,  Approaching Roadway Width: 51.2m (168.0ft),  Skew: 21 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 42.3m (138.8ft),  Out-to-Out Width: 43.9m (144.0ft)

Condition: Channel: Poor,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006
Find on map >>

Structure Number: 63200701000B01,  Location: BET ADAMS AND COOLIDGE RD (Lat: 42.590578,  Lng: -83.189442),  Route carried "on" structure: County highway 2059,  Year Built: 1984,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 19,700 (year 1996),  Truck Traffic: 5%,  Average Future Daily Traffic: 40,000 (year 2017),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: LONG LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.809,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 17.8m (58.4ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 67.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006
Find on map >>

Structure Number: 63200706000B01,  Location: BET JOHN R AND DEQUINDRE (Lat: 42.592564,  Lng: -83.108014),  Route carried "on" structure: County highway 2059,  Year Built: 1959,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 22,575 (year 0 ),  Truck Traffic: 5%,  Average Future Daily Traffic: 33,900 (year 2010),  Design Load: H 15,  Features Intersected: GIBSON DRAIN,  Facility Carried by Structure: LONG LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.494,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Channel: Very good,  Culverts: Excellent,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2006,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 634679200034B01,  Location: 0.1 MI N OF LONG LAKE RD (Lat: 42.591700,  Lng: -83.188286),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 1.20m (3.94ft),  Average Daily Traffic: 6,600 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 22,000 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: COOLIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.669,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 34.0m (111.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 64.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 634679200040B01,  Location: 0.2 MI S OF MAPLE ROAD (Lat: 42.545767,  Lng: -83.120275),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 11,600 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 41,400 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: BARNARD DRAIN,  Facility Carried by Structure: STEPHENSON HWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.326,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 51.0m (167.3ft),  Skew: 11 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 51.0m (167.3ft)

Condition: Channel: Very good,  Culverts: Fair,  Operating Rating: 40.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 634679200084B01,  Location: .15 MI N/BIG BEAVER RD (Lat: 42.564233,  Lng: -83.128494),  Route carried "on" structure: City street ,  Year Built: 1975,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 22.86m (75.00ft),  Average Daily Traffic: 28,750 (year 1997),  Truck Traffic: 7%,  Average Future Daily Traffic: 29,400 ,  Design Load: HS 20,  Features Intersected: STURGIS,  Facility Carried by Structure: ROCHESTER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.623,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 441,  Subroute: 38),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 5.0m (16.4ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 19.0m (62.3ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 41.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 634679200084C01,  Location: 2.7 MI N OF BIG BEAVER RD (Lat: 42.599875,  Lng: -83.129414),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 40,331 (year 1997),  Truck Traffic: 8%,  Average Future Daily Traffic: 49,000 (year 2010),  Design Load: HS 20,  Features Intersected: RENSHAW COUNTY DRAIN,  Facility Carried by Structure: ROCHESTER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.587,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 441,  Subroute: 38),  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 20.1m (65.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007
Find on map >>

Structure Number: 635679200069B01,  Location: 0.2 MI S OF MAPLE ROAD (Lat: 42.545897,  Lng: -83.129317),  Route carried "on" structure: Spur City street ,  Year Built: 1974,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 950 (year 1997),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,000 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: BARNARD DRAIN,  Facility Carried by Structure: SOUTER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.336,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.0m (29.5ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 635679200070B01,  Location: 0.2 MI S OF MAPLE ROAD (Lat: 42.545736,  Lng: -83.124856),  Route carried "on" structure: Spur City street ,  Year Built: 1969,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 2,300 (year 1997),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,700 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: BARNARD DRAIN,  Facility Carried by Structure: ALLEN DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.341,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 38.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 635679200071B01,  Location: 0.2 MI S OF MAPLE ROAD (Lat: 42.545750,  Lng: -83.113697),  Route carried "on" structure: Alternate City street ,  Year Built: 1971,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 12,700 (year 1997),  Truck Traffic: 8%,  Average Future Daily Traffic: 14,000 (year 1990),  Design Load: HS 20+Mod,  Features Intersected: BARNARD DRAIN,  Facility Carried by Structure: CHICAGO ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.367,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.0m (49.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 0.0m,  Curb-To-Curb Width: 15.0m (49.2ft),  Out-to-Out Width: 20.0m (65.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 26.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>

Structure Number: 635679200081B01,  Location: 0.5 MI E OF COOLIDGE (Lat: 42.603353,  Lng: -83.180017),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 2,800 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,000 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: ROUGE RIVER,  Facility Carried by Structure: NORTHFIELD PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.748,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.0m (75.5ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.0m (16.4ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 41.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 14.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 63163174000P07,  Location: @ WATTLES RD (Lat: 42.576892,  Lng: -83.158972),  Route carried "under" structure: Interstate 75,  Year Built: 1983,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 113,822 (year 2003),  Truck Traffic: 8%,  Features Intersected: I-75,  Facility Carried by Structure: WATTLES RD PED
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 18.004,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>

Structure Number: 63163174000S081,  Location: IN TROY (Lat: 42.559164,  Lng: -83.147514),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 3,630 (year ),  Features Intersected: LIVERNOIS RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 1.205,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S082,  Location: IN TROY (Lat: 42.558942,  Lng: -83.147506),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 3,630 (year 1974),  Features Intersected: LIVERNOIS RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 1.181,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S091,  Location: IN TROY (Lat: 42.562097,  Lng: -83.158025),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 33,540 (year 1974),  Features Intersected: BIG BEAVER RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 3.138,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: 63163174000S092,  Location: IN TROY (Lat: 42.562081,  Lng: -83.158350),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 5.27m (17.29ft),  Average Daily Traffic: 33,540 (year 1974),  Features Intersected: BIG BEAVER RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 3.111,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>

Structure Number: 63163174000S095,  Location: IN TROY (Lat: 42.562097,  Lng: -83.157806),  Route carried "under" structure: County highway ,  Year Built: 1983,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 28,800 (year 1983),  Features Intersected: BIG BEAVER ROAD,  Facility Carried by Structure: I-75 NB CD
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 3.154,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: 63163174000S096,  Location: IN TROY (Lat: 42.562078,  Lng: -83.158503),  Route carried "under" structure: County highway ,  Year Built: 1983,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 28,800 (year 1983),  Features Intersected: BIG BEAVER ROAD,  Facility Carried by Structure: I-75 SB CD
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 3.098,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.9m (48.9ft)

Find on map >>

Structure Number: 63163174000S1,  Location: IN TROY (Lat: 42.576983,  Lng: -83.158961),  Route carried "under" structure: Interstate 75,  Year Built: 1964,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 113,822 (year 2003),  Truck Traffic: 8%,  Features Intersected: I-75,  Facility Carried by Structure: WATTLES RD
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 18.013,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>

Structure Number: 63163174000S111,  Location: IN TROY (Lat: 42.591253,  Lng: -83.159269),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 12,000 (year 1974),  Features Intersected: EAST LONG LAKE RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 17.286,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S112,  Location: IN TROY (Lat: 42.591244,  Lng: -83.159581),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 12,000 (year 1974),  Features Intersected: EAST LONG LAKE RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 1.726,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S12,  Location: IN TROY (Lat: 42.599533,  Lng: -83.162544),  Route carried "under" structure: Interstate 75,  Year Built: 1964,  Structure Length: 6.89m (22.60ft),  Average Daily Traffic: 113,822 (year 2003),  Truck Traffic: 8%,  Features Intersected: I-75,  Facility Carried by Structure: RAMP CONNTO CHRYSL
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 20.579,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.3m (79.7ft)

Find on map >>

Structure Number: 63163174000S13,  Location: IN TROY (Lat: 42.604522,  Lng: -83.168997),  Route carried "under" structure: Interstate 75,  Year Built: 1990,  Structure Length: 8.59m (28.18ft),  Average Daily Traffic: 104,594 (year 2003),  Truck Traffic: 8%,  Features Intersected: I-75,  Facility Carried by Structure: N.B. CROOKS RD.
Minimum Vertical Clearance: 6.02m (19.75ft),  Kilometerpoint: 21.382,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Find on map >>

Structure Number: 63163174000S141,  Location: IN TROY (Lat: 42.604964,  Lng: -83.188828),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 1,340 (year 1974),  Features Intersected: COOLIDGE RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 8.274,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>

Structure Number: 63163174000S142,  Location: IN TROY (Lat: 42.604731,  Lng: -83.188828),  Route carried "under" structure: City street ,  Year Built: 1964,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 1,340 (year 1974),  Features Intersected: COOLIDGE RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 0.48m (1.57ft),  Kilometerpoint: 8.248,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.5m (41.0ft)

Find on map >>

Structure Number: 63163174000S151,  Location: IN TROY (Lat: 42.606083,  Lng: -83.205431),  Route carried "under" structure: City street 2059,  Year Built: 1964,  Structure Length: 4.81m (15.78ft),  Average Daily Traffic: 370 (year 1974),  Features Intersected: SQUARE LAKE RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 3.526,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.8m (74.8ft)

Find on map >>

Structure Number: 63163174000S152,  Location: IN TROY (Lat: 42.605886,  Lng: -83.205703),  Route carried "under" structure: City street 2059,  Year Built: 1964,  Structure Length: 4.81m (15.78ft),  Average Daily Traffic: 370 (year 1974),  Features Intersected: SQUARE LAKE RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 3.495,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.8m (74.8ft)

Find on map >>

Structure Number: 63163174000S161,  Location: IN TROY (OVER ADAMS RD) (Lat: 42.606767,  Lng: -83.208553),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 10,220 (year 1974),  Features Intersected: ADAMS RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.773,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>

Structure Number: 63163174000S162,  Location: IN TROY (OVER ADAMS RD) (Lat: 42.606511,  Lng: -83.208542),  Route carried "under" structure: County highway 2059,  Year Built: 1964,  Structure Length: 4.26m (13.98ft),  Average Daily Traffic: 10,220 (year 1974),  Features Intersected: ADAMS RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 7.702,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>

Structure Number: 63163174000S211,  Location: IN TROY (OVER MAPLE RD) (Lat: 42.548986,  Lng: -83.116586),  Route carried "under" structure: County highway 2059,  Year Built: 1963,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 19,000 (year ),  Truck Traffic: 6%,  Features Intersected: MAPLE RD, 15 MILE RD,  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 30.183,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S212,  Location: IN TROY (OVER MAPLE RD) (Lat: 42.548983,  Lng: -83.116900),  Route carried "under" structure: County highway 2059,  Year Built: 1963,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 19,000 (year 1974),  Truck Traffic: 10%,  Features Intersected: MAPLE RD, 15 MILE RD,  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 4.49m (14.73ft),  Kilometerpoint: 30.157,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 63163174000S32,  Location: IN TROY (Lat: 42.604886,  Lng: -83.169350),  Route carried "under" structure: Interstate 75,  Year Built: 1990,  Structure Length: 8.59m (28.18ft),  Average Daily Traffic: 104,594 (year 2003),  Truck Traffic: 8%,  Features Intersected: I-75,  Facility Carried by Structure: S.B. CROOKS RD.
Minimum Vertical Clearance: 5.89m (19.32ft),  Kilometerpoint: 21.412,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.9m (94.8ft)

Discuss this city on our hugely popular Michigan forum