Bridge Statistics for Victorville, California (CA) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Victorville, CA, California, California forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 18 Total length: 160 meters (525ft) Total average daily traffic: 794,610 Total average daily truck traffic: 137,202 National Bridge Inventory (NBI) Registered Bridges for Victorville
Bridge Condition - Deck Bridge Condition - Superstructure Bridge Condition - Substructure Bridge Condition - Channel Find on map >>
Structure Number: 54 047, Location: 08-SBD-018-R96.6-VCTV (Lat: 34.506667, Lng: -117.321667), Route carried "on" structure: State highway 18, Year Built: 1975, Status: Open, Structure Length: 7.07m (23.20ft), Average Daily Traffic: 38,000 (year 2000), Truck Traffic: 9%, Average Future Daily Traffic: 46,214 (year 2028), Design Load: HS 20, Features Intersected: INTERSTATE 15 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 96.600, Lanes on structure: 5, Lanes under structure: 8, Base Highway Network: Yes (, Subroute: 1), Owner: State Highway Agency, Approaching Roadway Width: 23.2m (76.1ft), Skew: 3 degrees, Material/Design: Prestressed concrete continuous, Design/Construction: Box Beam or Girders - Single/Spread, Number Of Spans In Main Unit: 2, Length of Maximum Span: 36.3m (119.1ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 23.2m (76.1ft), Out-to-Out Width: 26.8m (87.9ft) Condition: Deck: Fair, Superstructure: Very good, Substructure: Good, Operating Rating: 85.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: December 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 54 0483, Location: 08-SBD-015-43.86-VCTV (Lat: 34.548333, Lng: -117.293333), Route carried "on" structure: Interstate 15, Year Built: 1958, Year Reconstructed: 1971, Status: Open, Structure Length: 17.53m (57.51ft), Average Daily Traffic: 60,000 (year 2006), Truck Traffic: 24%, Average Future Daily Traffic: 84,000 (year 2030), Design Load: HS 20, Features Intersected: MOJAVE RIVER Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 43.860, Lanes on structure: 4, Base Highway Network: Yes (, Subroute: 1), Owner: State Highway Agency, Approaching Roadway Width: 26.8m (87.9ft), Skew: 32 degrees, Material/Design: Concrete continuous, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 8, Length of Maximum Span: 22.9m (75.1ft), Curb-To-Curb Width: 26.8m (87.9ft), Out-to-Out Width: 28.0m (91.9ft) Condition: Deck: Fair, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Very good, Operating Rating: 70.6 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 42.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present minimum criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Deck Protection: Bituminous Find on map >>
Structure Number: 54 0484, Location: 08-SBD-015-43.47-VCTV (Lat: 34.545000, Lng: -117.300000), Route carried "on" structure: Interstate 15, Year Built: 1958, Year Reconstructed: 1971, Status: Open, Structure Length: 11.64m (38.19ft), Average Daily Traffic: 67,000 (year 2000), Truck Traffic: 22%, Average Future Daily Traffic: 184,857 (year 2028), Design Load: HS 20, Features Intersected: BNSF RY,UP RR,AMTRAK,ETC Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 43.470, Lanes on structure: 6, Lanes under structure: 6, Base Highway Network: Yes (, Subroute: 1), Owner: State Highway Agency, Approaching Roadway Width: 26.8m (87.9ft), Skew: 31 degrees, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 6, Length of Maximum Span: 32.6m (107.0ft), Curb-To-Curb Width: 26.8m (87.9ft), Out-to-Out Width: 28.0m (91.9ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Satisfactory, Operating Rating: 54.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 54 0517, Location: 08-SBD-015-46.4-VCTV (Lat: 34.578333, Lng: -117.270000), Route carried "on" structure: Interstate 15, Year Built: 1958, Year Reconstructed: 2004, Status: Open, Structure Length: 0.82m (2.69ft), Average Daily Traffic: 57,000 (year 2006), Truck Traffic: 24%, Average Future Daily Traffic: 80,000 (year 2026), Design Load: HS 20, Features Intersected: CEMENT COMPANY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 46.400, Lanes on structure: 6, Base Highway Network: Yes (, Subroute: 1), Owner: State Highway Agency, Approaching Roadway Width: 16.8m (55.1ft), Material/Design: Concrete, Design/Construction: Slab, Number Of Spans In Main Unit: 1, Length of Maximum Span: 7.3m (24.0ft), Curb-To-Curb Width: 48.2m (158.1ft), Out-to-Out Width: 49.7m (163.1ft) Condition: Deck: Satisfactory, Superstructure: Good, Substructure: Satisfactory, Operating Rating: 45.3 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 27.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 54 0535, Location: 08-SBD-015-44.4-VCTV (Lat: 34.555000, Lng: -117.288333), Route carried "on" structure: County highway , Year Built: 1958, Status: Open, Structure Length: 5.97m (19.59ft), Average Daily Traffic: 3,500 (year 1998), Truck Traffic: 20%, Average Future Daily Traffic: 4,714 (year 2029), Design Load: HS 20, Features Intersected: INTERSTATE 15, Facility Carried by Structure: STODDARD WELLS RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 2, Lanes under structure: 6, Owner: State Highway Agency, Approaching Roadway Width: 8.5m (27.9ft), Skew: 2 degrees, Material/Design: Concrete continuous, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 20.1m (65.9ft), Curb or Sidewalk Widths: Left: 0.5m (1.6ft), Right: 0.5m (1.6ft), Curb-To-Curb Width: 8.5m (27.9ft), Out-to-Out Width: 10.1m (33.1ft) Condition: Deck: Fair, Superstructure: Good, Substructure: Good, Operating Rating: 63.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 38.2 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 54 0625, Location: 08-SBD-015-37.59-VCTV (Lat: 34.470000, Lng: -117.343333), Route carried "on" structure: County highway W603, Year Built: 1965, Year Reconstructed: 1991, Status: Open, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 60,000 (year 2004), Truck Traffic: 4%, Average Future Daily Traffic: 63,760 (year 2030), Design Load: HS 20, Features Intersected: INTERSTATE 15, Facility Carried by Structure: BEAR VALLEY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 7, Lanes under structure: 7, Owner: State Highway Agency, Approaching Roadway Width: 26.8m (87.9ft), Skew: 3 degrees, Material/Design: Concrete continuous, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 4, Length of Maximum Span: 33.5m (109.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 26.8m (87.9ft), Out-to-Out Width: 30.5m (100.1ft) Condition: Deck: Good, Superstructure: Good, Substructure: Good, Operating Rating: 54.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 54 0626, Location: 08-SBD-015-42.03-VCTV (Lat: 34.528333, Lng: -117.315000), Route carried "on" structure: City street Y535, Year Built: 1962, Status: Open, Structure Length: 6.98m (22.90ft), Average Daily Traffic: 12,000 (year 2006), Truck Traffic: 4%, Average Future Daily Traffic: 17,000 (year 2026), Design Load: HS 20, Features Intersected: INTERSTATE 15, Facility Carried by Structure: MOJAVE DRIVE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 3, Lanes under structure: 6, Owner: State Highway Agency, Approaching Roadway Width: 12.2m (40.0ft), Skew: 2 degrees, Material/Design: Concrete continuous, Design/Construction: Tee Beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 23.8m (78.1ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.5m (4.9ft), Curb-To-Curb Width: 12.2m (40.0ft), Out-to-Out Width: 16.3m (53.5ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Good, Operating Rating: 63.5 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 35.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 48 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 54 1118, Location: 08-SBD-015-41.43-VCTV (Lat: 34.520000, Lng: -117.318333), Route carried "on" structure: City street , Year Built: 1993, Status: Open, Structure Length: 8.96m (29.40ft), Average Daily Traffic: 12,000 (year 1998), Truck Traffic: 5%, Average Future Daily Traffic: 25,144 (year 2029), Design Load: HS 20+Mod, Features Intersected: INTERSTATE 15, Facility Carried by Structure: ROY ROGERS DRIVE Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 4, Lanes under structure: 8, Owner: State Highway Agency, Approaching Roadway Width: 23.2m (76.1ft), Skew: 1 degrees, Material/Design: Concrete continuous, Design/Construction: Box Beam or Girders - Multiple, Number Of Spans In Main Unit: 2, Length of Maximum Span: 39.6m (129.9ft), Curb or Sidewalk Widths: Left: 1.5m (4.9ft), Right: 1.5m (4.9ft), Curb-To-Curb Width: 23.2m (76.1ft), Out-to-Out Width: 26.8m (87.9ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Operating Rating: 54.0 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Superior to present desirable criteria, Underclear: Better than present minimum criteria, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: April 2008, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 54C0068, Location: 2.5 MI NORTH ROUTE I-15 (Lat: 34.574058, Lng: -117.321458), Route carried "on" structure: County highway Y479, Year Built: 1930, Status: Open, Structure Length: 17.53m (57.51ft), Average Daily Traffic: 7,040 (year 2004), Truck Traffic: 7%, Average Future Daily Traffic: 8,067 (year 2029), Design Load: H 15, Features Intersected: MOJAVE RIVER, Facility Carried by Structure: NAT TRAILS HWY Minimum Vertical Clearance: 4.75m (15.58ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 10.7m (35.1ft), Skew: 5 degrees, Material/Design: Steel, Design/Construction: Truss - Thru, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 6, Length of Maximum Span: 82.3m (270.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 10.4m (34.1ft), Out-to-Out Width: 11.1m (36.4ft) Condition: Deck: Good, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Good, Operating Rating: 73.4 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 49.0 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Meets minimum limits, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Meets minimum limits, Designated Inspection Frequency: Every 24 months, Critical Feature Inspection Frequency: Every 24 months, Inspection Date: January 2008, Critical Feature Inspection Date: March 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Bituminous Find on map >>
Structure Number: 54C0099, Location: 0.1 MI NE "D" ST (Lat: 34.533889, Lng: -117.287333), Route carried "on" structure: City street , Year Built: 1928, Status: Open, Structure Length: 9.57m (31.40ft), Average Daily Traffic: 20 (year 2008), Truck Traffic: 40%, Average Future Daily Traffic: 20 (year 2028), Design Load: H 15, Features Intersected: MOJAVE RIVER, Facility Carried by Structure: MINERAL ROAD Minimum Vertical Clearance: 4.39m (14.40ft), Kilometerpoint: 0.000, Lanes on structure: 2, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 6.1m (20.0ft), Material/Design: Steel, Design/Construction: Arch - Thru, Number Of Spans In Main Unit: 1, Number Of Approach Spans: 3, Length of Maximum Span: 70.1m (230.0ft), Curb or Sidewalk Widths: Left: 0.2m (0.7ft), Right: 0.2m (0.7ft), Curb-To-Curb Width: 6.1m (20.0ft), Out-to-Out Width: 6.5m (21.3ft) Condition: Deck: Satisfactory, Superstructure: Satisfactory, Substructure: Satisfactory, Channel: Fair, Operating Rating: 36.6 metric tons, Inventory Rating: 26.8 metric tons, Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Somewhat better than minimum adequacy, Underclear: Meets minimum limits, Waterway Adequacy: Equal to present desirable criteria, Approach Roadway Alignment: Somewhat better than minimum adequacy, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2008, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 54C0547, Location: 3.8 MI E OF ROUTE I-15 (Lat: 34.470950, Lng: -117.279250), Route carried "on" structure: County highway W603, Year Built: 1979, Status: Open, Structure Length: 4.11m (13.48ft), Average Daily Traffic: 64,000 (year 2006), Truck Traffic: 2%, Average Future Daily Traffic: 80,000 (year 2026), Design Load: HS 20, Features Intersected: BNSF RY, AMTRAK, & UP RR, Facility Carried by Structure: BEAR VALLEY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.000, Lanes on structure: 6, Owner: City or Municipal Highway Agency, Approaching Roadway Width: 23.5m (77.1ft), Material/Design: Prestressed concrete, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 3, Length of Maximum Span: 17.1m (56.1ft), Curb or Sidewalk Widths: Left: 0.0m, Right: 1.5m (4.9ft), Curb-To-Curb Width: 21.9m (71.9ft), Out-to-Out Width: 24.3m (79.7ft) Condition: Deck: Fair, Superstructure: Very good, Substructure: Satisfactory, Operating Rating: 86.1 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 32.6 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: High priority of corrective action, Underclear: Meets minimum limits, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: January 2008, Deck Structure Type: Concrete Cast-file-Place Find on map >>
Structure Number: 54 047, Location: 08-SBD-018-R96.6-VCTV (Lat: 34.506667, Lng: -117.321667), Route carried "under" structure: Interstate 15, Year Built: 1975, Structure Length: 7.07m (23.20ft), Average Daily Traffic: 67,000 (year 2000), Truck Traffic: 22%, Features Intersected: INTERSTATE 15, Facility Carried by Structure: STATE HIGHWAY 18 Minimum Vertical Clearance: 5.05m (16.57ft), Kilometerpoint: 4.051, Lanes on structure: 5, Lanes under structure: 8, Material/Design: Prestressed concrete continuous, Design/Construction: Box Beam or Girders - Single/Spread, Length of Maximum Span: 36.3m (119.1ft) Find on map >>
Structure Number: 54 0484, Location: 08-SBD-015-43.47-VCTV (Lat: 34.545000, Lng: -117.300000), Route carried "under" structure: State highway 18, Year Built: 1958, Structure Length: 11.64m (38.19ft), Average Daily Traffic: 36,000 (year 2000), Truck Traffic: 10%, Features Intersected: BNSF RY,UP RR,AMTRAK,ETC, Facility Carried by Structure: INTERSTATE 15 Minimum Vertical Clearance: 7.62m (25.00ft), Kilometerpoint: 9.657, Lanes on structure: 6, Lanes under structure: 4, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.6m (107.0ft) Find on map >>
Structure Number: 54 0484, Location: 08-SBD-015-43.47-VCTV (Lat: 34.545000, Lng: -117.300000), Route carried "under" structure: City street , Year Built: 1958, Structure Length: 11.64m (38.19ft), Average Daily Traffic: 50 (year 2002), Truck Traffic: 5%, Features Intersected: BNSF RY,UP RR,AMTRAK,ETC, Facility Carried by Structure: INTERSTATE 15 Minimum Vertical Clearance: 7.62m (25.00ft), Kilometerpoint: 0.000, Lanes on structure: 6, Lanes under structure: 2, Material/Design: Steel, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 32.6m (107.0ft) Find on map >>
Structure Number: 54 0535, Location: 08-SBD-015-44.4-VCTV (Lat: 34.555000, Lng: -117.288333), Route carried "under" structure: Interstate 15, Year Built: 1958, Structure Length: 5.97m (19.59ft), Average Daily Traffic: 60,000 (year 2006), Truck Traffic: 24%, Features Intersected: INTERSTATE 15, Facility Carried by Structure: STODDARD WELLS RD Minimum Vertical Clearance: 5.03m (16.50ft), Kilometerpoint: 0.444, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Concrete continuous, Design/Construction: Tee Beam, Length of Maximum Span: 20.1m (65.9ft) Find on map >>
Structure Number: 54 0625, Location: 08-SBD-015-37.59-VCTV (Lat: 34.470000, Lng: -117.343333), Route carried "under" structure: Interstate 15, Year Built: 1965, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 104,000 (year 2006), Truck Traffic: 18%, Features Intersected: INTERSTATE 15, Facility Carried by Structure: BEAR VALLEY ROAD Minimum Vertical Clearance: 4.95m (16.24ft), Kilometerpoint: 3.759, Lanes on structure: 7, Lanes under structure: 7, Material/Design: Concrete continuous, Design/Construction: Box Beam or Girders - Multiple, Length of Maximum Span: 33.5m (109.9ft) Find on map >>
Structure Number: 54 0626, Location: 08-SBD-015-42.03-VCTV (Lat: 34.528333, Lng: -117.315000), Route carried "under" structure: Interstate 15, Year Built: 1962, Structure Length: 6.98m (22.90ft), Average Daily Traffic: 60,000 (year 2006), Truck Traffic: 24%, Features Intersected: INTERSTATE 15, Facility Carried by Structure: MOJAVE DRIVE Minimum Vertical Clearance: 4.83m (15.85ft), Kilometerpoint: 4.203, Lanes on structure: 3, Lanes under structure: 6, Material/Design: Concrete continuous, Design/Construction: Tee Beam, Length of Maximum Span: 23.8m (78.1ft) Find on map >>
Structure Number: 54 1118, Location: 08-SBD-015-41.43-VCTV (Lat: 34.520000, Lng: -117.318333), Route carried "under" structure: Interstate 15, Year Built: 1993, Structure Length: 8.96m (29.40ft), Average Daily Traffic: 87,000 (year 2006), Truck Traffic: 22%, Features Intersected: INTERSTATE 15, Facility Carried by Structure: ROY ROGERS DRIVE Minimum Vertical Clearance: 5.51m (18.08ft), Kilometerpoint: 4.143, Lanes on structure: 4, Lanes under structure: 8, Material/Design: Concrete continuous, Design/Construction: Box Beam or Girders - Multiple, Length of Maximum Span: 39.6m (129.9ft) Discuss this city on our hugely popular California forum Back to: Victorville, CA, California, All US cities.
|
![]() |