Bridge Statistics for Villa Rica, Georgia (GA) - Condition, Traffic, Stress, Structural Evaluation, Project CostsBack to: Villa Rica, GA, Georgia, Georgia forum, All US cities. National Bridge Inventory (NBI) Statistics Number of bridges: 11 Total length: 104 meters (341ft) Total average daily traffic: 371,390 Total average daily truck traffic: 2,883 National Bridge Inventory (NBI) Registered Bridges for Villa Rica
Bridge Condition - Deck Bridge Condition - Substructure Find on map >>
Structure Number: 450032, Location: IN SW VILLA RICA (Lat: 33.721967, Lng: -84.930917), Route carried "on" structure: County highway 849, Year Built: 1974, Status: Open, Structure Length: 12.55m (41.17ft), Average Daily Traffic: 2,190 (year 2005), Average Future Daily Traffic: 3,285 (year 2025), Design Load: HS 20+Mod, Features Intersected: I-20, Facility Carried by Structure: S CARROLLTON RD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.104, Lanes on structure: 2, Lanes under structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 12.3m (40.4ft), Skew: 3 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 40.8m (133.9ft), Curb-To-Curb Width: 13.0m (42.7ft), Out-to-Out Width: 14.1m (46.3ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Operating Rating: 37.8 metric tons, Method Used To Determine Operating Rating: Load Factor (LF), Inventory Rating: 22.5 metric tons, Method Used To Determine Inventory Rating: Load Factor (LF), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Equal to present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 450033, Location: IN W VILLA RICA (Lat: 33.721800, Lng: -84.939050), Route carried "on" structure: State highway 61, Year Built: 1976, Status: Open, Structure Length: 9.96m (32.68ft), Average Daily Traffic: 26,520 (year 2005), Average Future Daily Traffic: 39,780 (year 2025), Design Load: HS 20+Mod, Features Intersected: I-20 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.383, Lanes on structure: 2, Lanes under structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.7m (38.4ft), Skew: 10 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 30.7m (100.7ft), Curb or Sidewalk Widths: Left: 0.1m (0.3ft), Right: 0.1m (0.3ft), Curb-To-Curb Width: 12.4m (40.7ft), Out-to-Out Width: 13.5m (44.3ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Good, Operating Rating: 45.9 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Better than present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 450034, Location: IN WEST VILLA RICA (Lat: 33.721733, Lng: -84.939300), Route carried "on" structure: State highway 61, Year Built: 1976, Status: Open, Structure Length: 10.72m (35.17ft), Average Daily Traffic: 26,520 (year 2005), Average Future Daily Traffic: 39,780 (year 2025), Design Load: HS 20+Mod, Features Intersected: I-20 Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.385, Lanes on structure: 2, Lanes under structure: 5, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 11.7m (38.4ft), Skew: 10 degrees, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 30.7m (100.7ft), Curb or Sidewalk Widths: Left: 0.1m (0.3ft), Right: 0.1m (0.3ft), Curb-To-Curb Width: 12.4m (40.7ft), Out-to-Out Width: 13.5m (44.3ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Satisfactory, Operating Rating: 45.9 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 450055, Location: IN SOUTH VILLA RICA (Lat: 33.721883, Lng: -84.922417), Route carried "on" structure: County highway 399, Year Built: 1974, Status: Open, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 630 (year 2005), Average Future Daily Traffic: 945 (year 2025), Design Load: HS 15, Features Intersected: I-20, Facility Carried by Structure: DANIEL STREET Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.218, Lanes on structure: 2, Lanes under structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 7.4m (24.3ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 30.7m (100.7ft), Curb-To-Curb Width: 11.5m (37.7ft), Out-to-Out Width: 12.3m (40.4ft) Condition: Deck: Very good, Superstructure: Very good, Substructure: Good, Operating Rating: 35.1 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 24.3 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Equal to present minimum criteria, Deck Geometry: Better than present minimum criteria, Underclear: Equal to present minimum criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 455128, Location: IN WEST VILLA RICA (Lat: 33.736900, Lng: -84.939100), Route carried "on" structure: State highway 101, Year Built: 1981, Status: Open, Structure Length: 0.79m (2.59ft), Average Daily Traffic: 14,120 (year 2005), Average Future Daily Traffic: 21,180 (year 2025), Design Load: HS 20+Mod, Features Intersected: SPRING BRANCH Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 0.180, Lanes on structure: 2, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 9.2m (30.2ft), Material/Design: Concrete, Design/Construction: Culvert, Number Of Spans In Main Unit: 3, Length of Maximum Span: 2.4m (7.9ft) Condition: Channel: Good, Culverts: Good, Operating Rating: 54.9 metric tons, Inventory Rating: 32.4 metric tons, Structural Evaluation: Better than present minimum criteria, Waterway Adequacy: Superior to present desirable criteria, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: August 2006 Find on map >>
Structure Number: 970041, Location: IN EAST VILLA RICA (Lat: 33.724417, Lng: -84.892000), Route carried "on" structure: County highway 2876, Year Built: 1974, Status: Open, Structure Length: 9.50m (31.17ft), Average Daily Traffic: 13,080 (year 2007), Average Future Daily Traffic: 19,620 (year 2027), Design Load: HS 20+Mod, Features Intersected: I-20, Facility Carried by Structure: LIBERTY ROAD Minimum Vertical Clearance: 30+ m (98+ ft), Kilometerpoint: 1.438, Lanes on structure: 2, Lanes under structure: 6, Base Highway Network: Yes, Owner: State Highway Agency, Approaching Roadway Width: 13.5m (44.3ft), Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Number Of Spans In Main Unit: 4, Length of Maximum Span: 30.4m (99.7ft), Curb-To-Curb Width: 14.3m (46.9ft), Out-to-Out Width: 15.4m (50.5ft) Condition: Deck: Good, Superstructure: Very good, Substructure: Fair, Operating Rating: 45.9 metric tons, Method Used To Determine Operating Rating: Allowable Stress (AS), Inventory Rating: 32.4 metric tons, Method Used To Determine Inventory Rating: Allowable Stress (AS), Structural Evaluation: Somewhat better than minimum adequacy, Deck Geometry: Superior to present desirable criteria, Underclear: Somewhat better than minimum adequacy, Approach Roadway Alignment: Equal to present desirable criteria, Designated Inspection Frequency: Every 24 months, Inspection Date: October 2007, Deck Structure Type: Concrete Cast-file-Place, Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete Find on map >>
Structure Number: 450032, Location: IN SW VILLA RICA (Lat: 33.721967, Lng: -84.930917), Route carried "under" structure: Interstate 20, Year Built: 1974, Structure Length: 12.55m (41.17ft), Average Daily Traffic: 56,900 (year 1999), Truck Traffic: 1%, Features Intersected: CR 849 S.CARROLLTON ROAD Minimum Vertical Clearance: 6.47m (21.23ft), Kilometerpoint: 3.953, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 40.8m (133.9ft) Find on map >>
Structure Number: 450033, Location: IN WEST VILLA RICA (Lat: 33.721800, Lng: -84.939050), Route carried "under" structure: Interstate 20, Year Built: 1976, Structure Length: 9.96m (32.68ft), Average Daily Traffic: 56,900 (year 1999), Truck Traffic: 1%, Features Intersected: SR 61 NBL Minimum Vertical Clearance: 6.68m (21.92ft), Kilometerpoint: 3.832, Lanes on structure: 2, Lanes under structure: 5, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.7m (100.7ft) Find on map >>
Structure Number: 450034, Location: IN WEST VILLA RICA (Lat: 33.721733, Lng: -84.939300), Route carried "under" structure: Interstate 20, Year Built: 1976, Structure Length: 10.72m (35.17ft), Average Daily Traffic: 56,900 (year 1999), Truck Traffic: 1%, Features Intersected: SR 61 SBL Minimum Vertical Clearance: 7.06m (23.16ft), Kilometerpoint: 3.829, Lanes on structure: 2, Lanes under structure: 5, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.7m (100.7ft) Find on map >>
Structure Number: 450055, Location: IN SOUTH VILLA RICA (Lat: 33.721883, Lng: -84.922417), Route carried "under" structure: Interstate 20, Year Built: 1974, Structure Length: 9.14m (29.99ft), Average Daily Traffic: 56,900 (year 1999), Truck Traffic: 1%, Features Intersected: CR 399 DANIEL STREET Minimum Vertical Clearance: 5.66m (18.57ft), Kilometerpoint: 3.998, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.7m (100.7ft) Find on map >>
Structure Number: 970041, Location: IN EAST VILLA RICA (Lat: 33.724417, Lng: -84.892000), Route carried "under" structure: Interstate 20, Year Built: 1974, Structure Length: 9.50m (31.17ft), Average Daily Traffic: 60,730 (year 1998), Truck Traffic: 1%, Features Intersected: FAS 2876 LIBERTY ROAD Minimum Vertical Clearance: 5.89m (19.32ft), Kilometerpoint: 4.233, Lanes on structure: 2, Lanes under structure: 6, Material/Design: Steel continuous, Design/Construction: Stringer/Multi-beam, Length of Maximum Span: 30.4m (99.7ft) Discuss this city on our hugely popular Georgia forum Back to: Villa Rica, GA, Georgia, All US cities.
|
![]() |