National Bridge Inventory (NBI) Statistics
Number of bridges: 20
Total length: 124 meters (407ft)
Total costs: $68,000
Total average daily traffic: 1,167,537
Total average daily truck traffic: 53,555
National Bridge Inventory (NBI) Registered Bridges for Vista

New bridges - Historical Statistics

  • 1960-1969: 6
  • 1970-1979: 2
  • 1980-1989: 0
  • 1990-1999: 12

Reconstructed bridges - Historical Statistics

  • 1980-1989: 1
  • 1990-1999: 1

Average Daily Traffic

Bridge Condition - Deck

Bridge Condition - Superstructure

Bridge Condition - Substructure

Bridge Condition - Channel

Find on map >>

Structure Number: 57 0398,  Location: 11-SD-078-5.94-VSTA (Lat: 33.195000,  Lng: -117.253333),  Route carried "on" structure: State highway 78,  Year Built: 1992,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 126,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 150,954 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: MELROSE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.940,  Lanes on structure: 6,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 34.7m (113.8ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 34.7m (113.8ft),  Out-to-Out Width: 35.7m (117.1ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57 04,  Location: 11-SD-078-6.94-VSTA (Lat: 33.188333,  Lng: -117.238333),  Route carried "on" structure: City street S372,  Year Built: 1962,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 28,100 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 41,217 (year 2029),  Design Load: HS 20,  Features Intersected: ROUTE 78,  Facility Carried by Structure: SUNSET DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 25.9m (85.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57 0401,  Location: 11-SD-078-7.71-VSTA (Lat: 33.181667,  Lng: -117.230000),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 2,190 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,152 (year 2029),  Design Load: HS 20,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: MAR VISTA DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.2m (99.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57 0402,  Location: 11-SD-078-9.08-VSTA (Lat: 33.166667,  Lng: -117.213333),  Route carried "on" structure: State highway 78,  Year Built: 1994,  Status: Open,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 160,949 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: SYCAMORE AVE
Minimum Vertical Clearance: 99.90m (327.76ft),  Kilometerpoint: 9.080,  Lanes on structure: 6,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 34.5m (113.2ft),  Out-to-Out Width: 35.8m (117.5ft)

Condition: Deck: Fair,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57 0515,  Location: 11-SD-078-6.15-VSTA (Lat: 33.195000,  Lng: -117.250000),  Route carried "on" structure: State highway 78,  Year Built: 1962,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 160,949 (year 2029),  Design Load: HS 20,  Features Intersected: BUENA VISTA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.150,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 32 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 33.9m (111.2ft),  Out-to-Out Width: 33.9m (111.2ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.86m (6.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $27,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $40,000
Find on map >>

Structure Number: 57 0515K,  Location: 11-SD-078-6.14-VSTA (Lat: 33.195000,  Lng: -117.250000),  Route carried "on" structure: Ramp State highway 78,  Year Built: 1999,  Status: Open,  Structure Length: 7.71m (25.30ft),  Average Daily Traffic: 8,900 (year 2005),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,807 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUENA VISTA CR ON-RAMP
Minimum Vertical Clearance: 99.00m (324.80ft),  Kilometerpoint: 6.140,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.8m (101.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 57 0515S,  Location: 11-SD-078-6.12-VSTA (Lat: 33.195000,  Lng: -117.250000),  Route carried "on" structure: Ramp State highway 78,  Year Built: 1999,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 7,900 (year 2005),  Truck Traffic: 1%,  Average Future Daily Traffic: 12,880 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUENA VISTA CREEK OFF-RA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.120,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.7m (74.5ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Other
Find on map >>

Structure Number: 57 0516,  Location: 11-SD-078-9.07-VSTA (Lat: 33.168333,  Lng: -117.215000),  Route carried "on" structure: State highway 78,  Year Built: 1962,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Average Future Daily Traffic: 160,949 (year 2029),  Design Load: HS 20,  Features Intersected: BUENA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.070,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 47.0m (154.2ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 47.0m (154.2ft),  Out-to-Out Width: 47.0m (154.2ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.04m (3.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Bridge Improvement Cost: $19,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $28,000
Find on map >>

Structure Number: 57 0768,  Location: 11-SD-078-4.38-VSTA (Lat: 33.188333,  Lng: -117.278333),  Route carried "on" structure: City street S367,  Year Built: 1971,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 13,000 (year 2000),  Truck Traffic: 1%,  Average Future Daily Traffic: 25,760 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: EMERALD DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 32.9m (107.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 83.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57 103,  Location: 11-SD-078-R6.19-VSTA (Lat: 33.195000,  Lng: -117.250000),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 32,100 (year 1999),  Truck Traffic: 1%,  Average Future Daily Traffic: 47,146 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: VISTA VILLAGE DR
Minimum Vertical Clearance: 99.00m (324.80ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 34.7m (113.8ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2007,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>

Structure Number: 57C0702,  Location: At Lado De Loma Drive (Lat: 33.196667,  Lng: -117.246667),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 3,000 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,695 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUENA VISTA CREEK CHAN,  Facility Carried by Structure: VISTA VILLAGE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 31.1m (102.0ft),  Out-to-Out Width: 54.6m (179.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 57C0703,  Location: 0.4 mi E/O Emerald Drive (Lat: 33.188333,  Lng: -117.271667),  Route carried "on" structure: City street ,  Year Built: 1993,  Status: Open,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 1,200 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,509 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: BUENA VISTA CREEK CHAN,  Facility Carried by Structure: HACIENDA DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 35 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 57C0704L,  Location: 0.5 MI S/O SHADOWRIDGE DR (Lat: 33.154083,  Lng: -117.240750),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,249 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: AGUA HEDIONDA CREEK,  Facility Carried by Structure: SOUTH MELROSE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.8m (110.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 57C0704R,  Location: 0.5 MI S/O SHADOWRIDGE DR (Lat: 33.155000,  Lng: -117.240000),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,249 (year 2029),  Design Load: HS 20+Mod,  Features Intersected: AGUA HEDIONDA CREEK,  Facility Carried by Structure: SOUTH MELROSE DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.8m (110.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2007,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>

Structure Number: 57 0398,  Location: 11-SD-078-5.94-VSTA (Lat: 33.195000,  Lng: -117.253333),  Route carried "under" structure: City street S368,  Year Built: 1992,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 24,047 (year 1999),  Truck Traffic: 6%,  Features Intersected: MELROSE DR,  Facility Carried by Structure: STATE ROUTE 78
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>

Structure Number: 57 04,  Location: 11-SD-078-6.94-VSTA (Lat: 33.188333,  Lng: -117.238333),  Route carried "under" structure: State highway 78,  Year Built: 1962,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Features Intersected: ROUTE 78,  Facility Carried by Structure: SUNSET DRIVE
Minimum Vertical Clearance: 0.47m (1.54ft),  Kilometerpoint: 0.694,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>

Structure Number: 57 0401,  Location: 11-SD-078-7.71-VSTA (Lat: 33.181667,  Lng: -117.230000),  Route carried "under" structure: State highway 78,  Year Built: 1962,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: MAR VISTA DRIVE
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.771,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 30.2m (99.1ft)

Find on map >>

Structure Number: 57 0402,  Location: 11-SD-078-9.08-VSTA (Lat: 33.166667,  Lng: -117.213333),  Route carried "under" structure: City street ,  Year Built: 1994,  Structure Length: 4.94m (16.21ft),  Average Daily Traffic: 31,100 (year 2000),  Truck Traffic: 1%,  Features Intersected: SYCAMORE AVE,  Facility Carried by Structure: STATE ROUTE 78
Minimum Vertical Clearance: 0.46m (1.51ft),  Kilometerpoint: 0.908,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.6m (84.0ft)

Find on map >>

Structure Number: 57 0768,  Location: 11-SD-078-4.38-VSTA (Lat: 33.188333,  Lng: -117.278333),  Route carried "under" structure: State highway 78,  Year Built: 1971,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 126,000 (year 1998),  Truck Traffic: 5%,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: EMERALD DR
Minimum Vertical Clearance: 0.49m (1.61ft),  Kilometerpoint: 0.438,  Lanes on structure: 7,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 31.4m (103.0ft)

Find on map >>

Structure Number: 57 103,  Location: 11-SD-078-R6.19-VSTA (Lat: 33.195000,  Lng: -117.250000),  Route carried "under" structure: State highway 78,  Year Built: 1999,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 127,000 (year 1998),  Truck Traffic: 5%,  Features Intersected: STATE ROUTE 78,  Facility Carried by Structure: VISTA VILLAGE DR
Minimum Vertical Clearance: 5.73m (18.80ft),  Kilometerpoint: 0.619,  Lanes on structure: 7,  Lanes under structure: 6,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 36.0m (118.1ft)