Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Watertown, South Dakota (SD)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 45Number of bridges
  • 509ft / 155mTotal length
  • $17,620,000Total costs
  • 148,116Total average daily traffic
  • 17,118Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Watertown
  • No street view available for this location

New bridges in Watertown, SD - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 31930-1939
  • 21940-1949
  • 11950-1959
  • 31960-1969
  • 211970-1979
  • 41980-1989
  • 31990-1999
  • 22000-2009
  • 52010-2019
Reconstructed bridges in Watertown, SD - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 01980-1989
  • 11990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Watertown, SD
Average Bridge Truck Traffic in Watertown, SD
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.2%Very good
  • 16.1%Good
  • 58.1%Satisfactory
  • 16.1%Fair
  • 6.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 6.5%Very good
  • 16.1%Good
  • 48.4%Satisfactory
  • 22.6%Fair
  • 6.5%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 3.2%Very good
  • 12.9%Good
  • 58.1%Satisfactory
  • 16.1%Fair
  • 6.5%Poor
  • 3.2%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 21.9%Very good
  • 50.0%Good
  • 15.6%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 25.0%Good
  • 25.0%Satisfactory
  • 25.0%Poor
Find on map >>   Show street view

Structure Number: 15140138,  Location: NORTH LAKE KAMPESKA (Lat: 44.951417,  Lng: -97.208075),  Route carried "on" structure: Spur State highway 20,  Year Built: 1931,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 64 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 90 (year 2041),  Features Intersected: CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 634.098,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Channel: Good,  Culverts: Poor,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 25.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 1.01m (3.31ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $12,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $14,000
Find on map >>   Show street view

Structure Number: 15141139,  Location: 0.3SW of Jct with SD 20 (Lat: 44.949403,  Lng: -97.206439),  Route carried "on" structure: City street ,  Year Built: 1931,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 640 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 868 (year 2032),  Features Intersected: Creek,  Facility Carried by Structure: N. Lake Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Poor,  Operating Rating: 29.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.05m (6.73ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $344,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $550,000 ( Estimate for 2021)
Find on map >>   Show street view

Structure Number: 15156143,  Location: 1.3 SE JCT SD 139 (Lat: 44.944239,  Lng: -97.175256),  Route carried "on" structure: State highway 20,  Year Built: 1958,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 3,572 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,026 (year 2041),  Design Load: H 20,  Features Intersected: LAKE KAMPESKA OUTLET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 636.721,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 49.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2020,  Underwater Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 151591,  Location: 8N 3.2 W WATERTOWN (Lat: 45.006086,  Lng: -97.164842),  Route carried "on" structure: County highway ,  Year Built: 1966,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 73 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 73 (year 2032),  Design Load: H 20,  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 164 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.55m (18.21ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $80,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $90,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1516511,  Location: 7.0N & 2.5W WATERTOWN (Lat: 44.991458,  Lng: -97.155717),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 73 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 73 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 165 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.2m (17.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.23m (10.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 15170144,  Location: 3.6N 2.0W WATERTOWN (Lat: 44.942700,  Lng: -97.146336),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 1,499 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,600 (year 2035),  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: SIOUX CONIFER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 2.44m (8.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,000,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $1,200,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1517816,  Location: 2 N 1.2W WATERTOWN (Lat: 44.919203,  Lng: -97.129331),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 4,970 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,700 (year 2040),  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 14TH AVE. N, WTN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.0m (49.2ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 24.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,800,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $2,000,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15179165,  Location: 10TH AVE - WATERTOWN (Lat: 44.911897,  Lng: -97.128614),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 3,089 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 3,089 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: CITY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15179183,  Location: 0.2E & 0.3S OF JCT 20/212 (Lat: 44.885606,  Lng: -97.127939),  Route carried "on" structure: Bypass City street ,  Year Built: 2012,  Status: Open,  Structure Length: 1.62m (5.31ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,300 (year 2032),  Design Load: HL 93,  Features Intersected: PELICAN LAKE CHANNEL,  Facility Carried by Structure: SOUTH CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018
Find on map >>   Show street view

Structure Number: 1518117,  Location: 0.3E of 10th Street NW (Lat: 44.904661,  Lng: -97.125231),  Route carried "on" structure: City street ,  Year Built: 1941,  Status: Posted for load,  Structure Length: 3.22m (10.56ft),  Average Daily Traffic: 4,837 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,837 (year 2032),  Features Intersected: Big Sioux River,  Facility Carried by Structure: 3rd Avenue NW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 5.4m (17.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Serious,  Channel: Satisfactory,  Operating Rating: 18.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 14.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 4.09m (13.42ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $1,038,000,  Roadway Improvement Cost: $104,000,  Total Project Cost: $1,707,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15181171,  Location: 0.3E of 10th Street NW (Lat: 44.902697,  Lng: -97.125722),  Route carried "on" structure: City street ,  Year Built: 1935,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 5,053 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,053 (year 2032),  Features Intersected: Big Sioux River,  Facility Carried by Structure: W Kemp Avenue
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 5.9m (19.4ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 4.17m (13.68ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $1,147,000,  Roadway Improvement Cost: $115,000,  Total Project Cost: $1,866,000 ( Estimate for 2021),  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15181175,  Location: 0.3E of 10th Street SW (Lat: 44.897397,  Lng: -97.125819),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 1,831 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,831 (year 2032),  Design Load: HS 20,  Features Intersected: Big Sioux River,  Facility Carried by Structure: 4th Avenue SW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 34.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.37m (17.62ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $1,387,000,  Roadway Improvement Cost: $139,000,  Total Project Cost: $2,204,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 1518118,  Location: 0.7 W JCT US 81 (Lat: 44.890131,  Lng: -97.124356),  Route carried "on" structure: US 212,  Year Built: 2019,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 15,049 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,550 (year 2041),  Design Load: HL 93,  Features Intersected: BIG SIOUX RV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 606.063,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.0m (42.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 22.4m (73.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 15184181,  Location: S. BROADWAY - WATERTOWN (Lat: 44.889256,  Lng: -97.118986),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2016,  Status: Posted for load,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 169 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 169 (year 2032),  Design Load: HL 93,  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: S BROADWAY WTN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.0m (88.6ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 27.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 21.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 15184186,  Location: 0.7E & 0.6S JCT 20/212 (Lat: 44.882081,  Lng: -97.120306),  Route carried "on" structure: Bypass City street ,  Year Built: 2012,  Status: Open,  Structure Length: 2.22m (7.28ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 8,300 (year 2032),  Design Load: HL 93,  Features Intersected: PELICAN LAKE CUTOFF CHAN,  Facility Carried by Structure: SOUTH CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018
Find on map >>   Show street view

Structure Number: 15190111,  Location: 7 N JCT US 212 (Lat: 44.991272,  Lng: -97.106061),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 1,425 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,425 (year 2032),  Design Load: HS 20,  Features Intersected: CK,  Facility Carried by Structure: 455 AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.5m (24.6ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15190137,  Location: 4.4 N JCT US 212 (Lat: 44.953047,  Lng: -97.106769),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,758 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,758 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: CK,  Facility Carried by Structure: 455 AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 15190186,  Location: 0.7 S JCT US 212 (Lat: 44.880581,  Lng: -97.108919),  Route carried "on" structure: US 81,  Year Built: 1966,  Status: Open,  Structure Length: 3.64m (11.94ft),  Average Daily Traffic: 6,471 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,266 (year 2041),  Design Load: HS 20,  Features Intersected: BIG SIOUX RV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 250.092,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 20.9m (68.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1519619,  Location: 1.0S & 0.5E of Watertown (Lat: 44.876542,  Lng: -97.098089),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 11.29m (37.04ft),  Average Daily Traffic: 3,464 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,147 (year 2037),  Design Load: HL 93,  Features Intersected: Big Sioux River,  Facility Carried by Structure: 20th Avenue SE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.7m (90.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 12.17m (39.93ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $2,633,000,  Roadway Improvement Cost: $263,000,  Total Project Cost: $3,979,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1520219,  Location: 1.0S&1.2E WATERTOWN (Lat: 44.876517,  Lng: -97.083692),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 60 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 60 (year 2032),  Design Load: HL 93,  Features Intersected: WILLOW CK,  Facility Carried by Structure: 20TH AVE. S, WTN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1520318,  Location: 1.4 E JCT US 81 (Lat: 44.890069,  Lng: -97.079639),  Route carried "on" structure: US 212,  Year Built: 1970,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 11,382 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 16,299 (year 2041),  Design Load: HS 20,  Features Intersected: WILLOW CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 609.314,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.9m (45.6ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 15205177,  Location: 1ST AVE NE (Lat: 44.893900,  Lng: -97.075361),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 200 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 200 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK,  Facility Carried by Structure: 1ST AVE NE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.6m (64.3ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.8m (104.3ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 0.0m,  Curb-To-Curb Width: 19.6m (64.3ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1520918,  Location: 1.9 E JCT US 81 (Lat: 44.889942,  Lng: -97.065914),  Route carried "on" structure: US 212,  Year Built: 1970,  Status: Open,  Structure Length: 0.69m (2.26ft),  Average Daily Traffic: 12,968 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 17,546 (year 2040),  Design Load: HS 20,  Features Intersected: CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 610.392,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 31.1m (102.0ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Inventory Rating: 99.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018
Find on map >>   Show street view

Structure Number: 15214163,  Location: 1.7 N US 212 INTERCH (Lat: 44.914675,  Lng: -97.056531),  Route carried "on" structure: Interstate 29,  Year Built: 1973,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 4,015 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 6,111 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 289.103,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1521418,  Location: US 212 & I 29 INTERCHANGE (Lat: 44.890475,  Lng: -97.057044),  Route carried "on" structure: Interstate 29,  Year Built: 1970,  Status: Open,  Structure Length: 9.39m (30.81ft),  Average Daily Traffic: 4,015 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 6,111 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: US212
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 286.399,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 152151,  Location: 8 N US 212 INTERCHANGE (Lat: 45.006131,  Lng: -97.054564),  Route carried "on" structure: Interstate 29,  Year Built: 1973,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 4,040 (year 2021),  Truck Traffic: 29%,  Average Future Daily Traffic: 6,016 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: 164 ST (FAS 6287)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 299.258,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1521512,  Location: 6 N US 212 INTERCH (Lat: 44.976925,  Lng: -97.054339),  Route carried "on" structure: County highway ,  Year Built: 1973,  Status: Open,  Structure Length: 8.99m (29.49ft),  Average Daily Traffic: 73 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 73 (year 2040),  Design Load: HS 20,  Features Intersected: I029,  Facility Carried by Structure: 166 ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 57.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1521515,  Location: 3 N US 212 INTERCHANGE (Lat: 44.933728,  Lng: -97.055294),  Route carried "on" structure: US 81,  Year Built: 1973,  Status: Open,  Structure Length: 8.85m (29.04ft),  Average Daily Traffic: 1,606 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,260 (year 2041),  Design Load: HS 20,  Features Intersected: I029
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 260.134,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 56.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 15215163,  Location: 1.7 N US 212 INTERCH (Lat: 44.914678,  Lng: -97.056086),  Route carried "on" structure: Interstate 29,  Year Built: 1973,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 4,015 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 6,111 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 289.103,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete,  Membrane: Epoxy
Find on map >>   Show street view

Structure Number: 1521518,  Location: US 212 & I 29 INTERCHANGE (Lat: 44.890461,  Lng: -97.056628),  Route carried "on" structure: Interstate 29,  Year Built: 1971,  Status: Open,  Structure Length: 9.39m (30.81ft),  Average Daily Traffic: 4,015 (year 2021),  Truck Traffic: 27%,  Average Future Daily Traffic: 6,111 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: US212
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 286.399,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 1521523,  Location: 5.0S 2.5E WATERTOWN (Lat: 44.818489,  Lng: -97.056503),  Route carried "on" structure: County highway ,  Year Built: 1920,  Status: Posted for load,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 73 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 73 (year 2032),  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 177 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 6.6m (21.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Good,  Operating Rating: 18.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 3.05m (10.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,000,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $1,200,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 1521622,  Location: 4.0S 2.6E WATERTOWN (Lat: 44.833011,  Lng: -97.055950),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Posted for load,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 468 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 2035),  Design Load: H 20,  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 176 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 33.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 3.41m (11.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $1,800,000,  Roadway Improvement Cost: $200,000,  Total Project Cost: $2,000,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1521821,  Location: 3.0S & 2.8E WATERTOWN (Lat: 44.847567,  Lng: -97.049433),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Posted for load,  Structure Length: 3.09m (10.14ft),  Average Daily Traffic: 41 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 41 (year 2032),  Features Intersected: BIG SIOUX RV,  Facility Carried by Structure: 175 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.6m (80.7ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 23.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 15.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 3.11m (10.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $500,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $550,000,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 15220161,  Location: 3.0E 1.9N WATERTOWN (Lat: 44.918897,  Lng: -97.045586),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 73 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 73 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK,  Facility Carried by Structure: 43RD ST., WTN.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 10.8m (35.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Length Of Structure Improvement: 0.61m (2.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $10,000,  Total Project Cost: $10,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 15220199,  Location: 2.3 SE US 212 INTERCH (Lat: 44.863278,  Lng: -97.047561),  Route carried "on" structure: Interstate 29,  Year Built: 1972,  Status: Open,  Structure Length: 5.32m (17.45ft),  Average Daily Traffic: 3,975 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 5,970 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: 458 AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 283.132,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 152202,  Location: 2.3 SE US 212 INTERCH (Lat: 44.862822,  Lng: -97.047544),  Route carried "on" structure: Interstate 29,  Year Built: 1972,  Status: Open,  Structure Length: 5.32m (17.45ft),  Average Daily Traffic: 3,975 (year 2021),  Truck Traffic: 18%,  Average Future Daily Traffic: 5,970 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: 458 AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 283.132,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 15230166,  Location: 4.0E 1.4N WATERTOWN (Lat: 44.910250,  Lng: -97.025011),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 100 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 110 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK,  Facility Carried by Structure: 459 AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1523916,  Location: 4.9E 2N WATERTOWN (Lat: 44.918817,  Lng: -97.004872),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 49 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 49 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: WILLOW CK,  Facility Carried by Structure: 170 STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 15240155,  Location: 5.0E 2.5N WATERTOWN (Lat: 44.926081,  Lng: -97.004350),  Route carried "on" structure: County highway ,  Year Built: 1973,  Year Reconstructed: 2001,  Status: Posted for load,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 336 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 336 (year 2017),  Features Intersected: WILLOW CK,  Facility Carried by Structure: 460 AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 21.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $250,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $250,000 ( Estimate for 2020),  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1521418,  Location: US 212 & I 29 INTERCHANGE (Lat: 44.890475,  Lng: -97.057044),  Route carried "under" structure: US 212,  Year Built: 1970,  Structure Length: 0. m,  Average Daily Traffic: 12,968 (year 2020),  Truck Traffic: 11%,  Features Intersected: US212,  Facility Carried by Structure: I029 S
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 611.116,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 1521512,  Location: 6 N US 212 INTERCH (Lat: 44.976925,  Lng: -97.054339),  Route carried "under" structure: Interstate 29,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 7,370 (year 2020),  Truck Traffic: 19%,  Features Intersected: I029,  Facility Carried by Structure: 166 ST
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 296.023,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Discuss Watertown, South Dakota (SD) on our hugely popular South Dakota forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.